• Title/Summary/Keyword: maximum sensitivity

Search Result 944, Processing Time 0.024 seconds

Evaluation of TlBr semiconductor detector in gamma camera imaging: Monte Carlo simulation study

  • Youngjin Lee;Chanrok Park
    • Nuclear Engineering and Technology
    • /
    • v.54 no.12
    • /
    • pp.4652-4659
    • /
    • 2022
  • Among the detector materials available at room temperature, thallium bromide (TlBr), which has a relatively high atomic number and density, is widely used for gamma camera imaging. This study aimed to verify the usefulness of TlBr through quantitative evaluation by modeling detectors of various compound types using Monte Carlo simulations. The Geant4 application for tomographic emission was used for simulation, and detectors based on cadmium zinc telluride and cadmium telluride materials were selected as a comparison group. A pixel-matched parallel-hole collimator with proven excellent performance was modeled, and phantoms used for quality control in nuclear medicine were used. The signal-to-noise ratio (SNR), contrast to noise ratio (CNR), sensitivity, and full width at half maximum (FWHM) were used for quantitative analysis to evaluate the image quality. The SNR, CNR, sensitivity, and FWHM for the TlBr detector material were approximately 1.05, 1.04, 1.41, and 1.02 times, respectively, higher than those of the other detector materials. The SNR, CNR and sensitivity increased with increasing detector thickness, but the spatial resolution in terms of FWHM decreased. Thus, we demonstrated the feasibility and possibility of using the TlBr detector material in comparison with commercial detector materials.

Covered Microlens Structure for Quad Color Filter Array of CMOS Image Sensor

  • Jae-Hyeok Hwang;Yunkyung Kim
    • Current Optics and Photonics
    • /
    • v.7 no.5
    • /
    • pp.485-495
    • /
    • 2023
  • The pixel size in high-resolution complementary metal-oxide-semiconductor (CMOS) image sensors continues to shrink due to chip size limitations. However, the pixel pitch's miniaturization causes deterioration of optical performance. As one solution, a quad color filter (CF) array with pixel binning has been developed to enhance sensitivity. For high sensitivity, the microlens structure also needs to be optimized as the CF arrays change. In this paper, the covered microlens, which consist of four microlenses covered by one large microlens, are proposed for the quad CF array in the backside illumination pixel structure. To evaluate the optical performance, the suggested microlens structure was simulated from 0.5 ㎛ to 1.0 ㎛ pixels at the center and edge of the sensors. Moreover, all pixel structures were compared with and without in-pixel deep trench isolation (DTI), which works to distribute incident light uniformly into each photodiode. The suggested structure was evaluated with an optical simulation using the finite-difference time-domain method for numerical analysis of the optical characteristics. Compared to the conventional microlens, the suggested microlens show 29.1% and 33.9% maximum enhancement of sensitivity at the center and edge of the sensor, respectively. Therefore, the covered microlens demonstrated the highly sensitive image sensor with a quad CF array.

Colorimetric Determination of Trace Mercury(II) in Water by Back Extraction and PAR (역추출과 PAR법에 의한 수질중 미량 수은의 비색정량에 관한 연구)

  • 정창웅
    • Journal of Environmental Health Sciences
    • /
    • v.21 no.3
    • /
    • pp.96-101
    • /
    • 1995
  • A selective and highly sensitive spectrophotometric measurements have been developed for the determination of trace mercury(II) with thiosulfate and PAR. Hg(II)-thiosulfate complex was extracted into high molecular alkylamine such as quaternary ammonium salt and back extracted into 1 M-HCl solution. The Hg(II)-PAR complex has maximum absorbance at 499 nm and obeys Beer's law in the range of 0.04~1.0 $\mu g/mL$ of mercury(II). The molar absorptivity and Sandell's sensitivity are $6.27\times 10^4 L.mole^{-1} cm^{-1}$ and $3.2\times 10^{-3}g/cm^2$ respectively.

  • PDF

Estimation Model of the Change in Dairy Leaf Surface Temperature Using Scaling Technique

  • Eom, Ki-Cheol;Eom, Ho-Yong
    • Korean Journal of Soil Science and Fertilizer
    • /
    • v.46 no.5
    • /
    • pp.359-364
    • /
    • 2013
  • This study was conducted to develop a model to estimate crop leaf surface temperature. The results were as following; A definition for the daily time based on elapsed time from the midnight (00:00) as "E&E time" with the unit of Kmin. was suggested. The model to estimate the scaled temperature ($T^*e$) of crop leaf surface temperature by scale factor ($T^*$) according to the "E&E time : Kmin."(X) was developed as eq. (1) $T^*e=0.5{\cdot}sin(X+780)+0.5$ (2) $T^*=(Tx-Tn)/(Tm-Tn)$, Tx : Daily leaf temperature, Tm : Daily maximum leaf temperature, Tn : Daily minimum leaf temperature. Relative sensitivity of the measured temperature compared to the estimated temperature of red pepper, soybean and persimmon was 1.078, 1.033 and 0.973, respectively.

Improvement of the Ammonia Analysis by the Phenate Method in Water and Wastewater

  • Park, Ga-Eun;Oh, Ha-Na;Ahn, Sam-Young
    • Bulletin of the Korean Chemical Society
    • /
    • v.30 no.9
    • /
    • pp.2032-2038
    • /
    • 2009
  • The amount of phenol and NaOH for the colorimetric determination of ammonia in Korean standard methods (KSM) is found to be highly excessive compared to the standard methods of several other countries. The absorbance of indophenol formed by the Berthelot reaction for ammonia analysis was measured under the various reaction conditions classified in experiment groups 1, 2, 3, 4 and KSM and American standards methods (ASM), and the relationships between the absorbance of indophenol and concentration of ammonia were compared. The amount of phenol can be reduced to 10 g (current 25 g in KSM) and NaOH can be reduced to 1.76 g (current 11 g in KSM) for the preparation of 200 mL phenate solution, and the absorbance sensitivity increased. The concentration of the phenol and NaOH correlatively affect the pH of the solution, which is a critical variable in achieving the maximum sensitivity and rapid and stable color development.

Shape Design of Electrode by Sensitivity Analysis (민감도 해석에 의한 전극의 형상설계)

  • Lee, Beom-Taek;Park, Il-Han;Hahn, Song-Yop
    • Proceedings of the KIEE Conference
    • /
    • 1990.11a
    • /
    • pp.15-18
    • /
    • 1990
  • In this paper, in order to optimize the shape of electrode to achieve prescribed electric field intensity distribution along the surface of electrode, sensitivity analysis based on finite element method is proposed. The objective function of this problem is the difference of calculated electric field intensity at given design and prescribed electric field intensity. So, the problem is to find the shape of electrode to minimize the objective function defined above. The result of numerical example shows that maximum electric field error is about 0.1% and the usefulness of this shape optimal design procedure.

  • PDF

Sensitivity analysis of software reliability metric estimator for Software Reliability Growth Models (신뢰성 성장모형에 대한 소프트웨어 신뢰성 메트릭 추정량의 민감도 분석)

  • Kim, Dae-Kyung
    • Journal of Korean Society for Quality Management
    • /
    • v.37 no.3
    • /
    • pp.33-38
    • /
    • 2009
  • When we estimate the parameters of software reliability models, we usually use maximum liklihood estimator(MLE). But this method is required a large data set. In particular, when we want to estimate it with small observed data such as early stages of testing, we give rise to the non-existence of MLE. Therefore, it is interesting to look into the influence of parameter estimators obtained using MLE. In this paper, we use two non-homogenous poisson process software reliability growth model: delayed S-shaped model and log power model. In this paper, we calculate the sensitivity of estimators about failure intensity function for two SRGMs respectively.

The CO sensing Property of ZnO composite ceramics by $SnO_2$ content ($SnO_2$ 첨가량에 따른 ZnO복합체의 일산화탄소 감응특성)

  • Kim, Tae-Won;Jung, Seung-Woo;Choi, U-Sung
    • Proceedings of the KIEE Conference
    • /
    • 1997.07d
    • /
    • pp.1455-1458
    • /
    • 1997
  • In order to promote CO gas sensitivity, $SnO_2$ added ZnO prepared. The electrical conductivities and dielectric constants decreased by increasing $SnO_2$ content in air. The electrical conductivities in 1000ppm CO atmosphere were larger than in dry air. The measured CO sensitivities were $1{\sim}15.2$ at $100^{\circ}C{\sim}480^{\circ}C$. The maximum CO sensitivity of 15mol% $SnO_2$ added ZnO was 15.2 at $305^{\circ}C$.

  • PDF

Optimization and sensitivity analysis of the humanoid robot's foot using the design of experiments (실험계획법에 의한 휴머노이드 발의 민감도 해석 및 최적화)

  • Yoon, Ji-Won;Park, Tae-Won;Jung, Sung-Pil;Park, Joong-Kyung
    • Proceedings of the KSME Conference
    • /
    • 2007.05a
    • /
    • pp.933-938
    • /
    • 2007
  • These days, up-to-date humanoid robots are continuously developed. Among them, Qrio, Asimo[1,2] are famous for its unique walking technology and natural movement. These robots could show manufacturers' technological improvement and leave a good impression to the customer. In accordance with global trends, Samsung is also producing humanoid robot. The humanoid robot, however, could walk like a human compared to the industrial robot fixed in the factory. This feature could cause another dynamic effect while walking. In this paper, the robot's feet were examined to find out parameters that affect stability of the humanoid robot's feet. With the sensitivity analysis, the optimization procedure in design of experiments finds the most suitable performance of robot. Maximum deflection of the frame upon various cases was minimized, and rubber coefficients for shock absorption were optimized.

  • PDF

Planar Vibratory Gyroscope using Electrostatic Actuation and Electromagnetic Detection (정전력 구동 및 전자력 검출형 평면 진송 각속도계)

  • 이상훈;임형택;이승기
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 1995.10a
    • /
    • pp.1089-1092
    • /
    • 1995
  • A planar vibratory gyroscope using electrostatic actuation and electromagnetic detection is proposed. The gyroscope has large sensitivity and can be fabricated by using surface micrimachining, bulk micromachining and conventional machining technology. In this paper, the gyroscope and the electromagnetic detecting system equations are derived to determine the output characteristics for the planar vibratory gyroscope using electrostatic acturation and electromagnetic detection. The maximum output is obtained when the driving frequencyequals to the detecting frequency. The resonant frequencies of the resonator are determined by the beam stiffness, i.e. the material constants and spring dimensions. The dimensions of the beams are determined using the analytic vibration modelling. The expected resonant frequencies are 200Hz both and the sensitivity is 62mV/deg/sec with 4000 electronic circuit amplifying coefficient for an AC drive voltage of 3V bias voltage of 15V and DC field current of 50 mA.

  • PDF