• Title/Summary/Keyword: maximum rate phenomenon

Search Result 86, Processing Time 0.026 seconds

An Experimental Study on the Heat Dissipation Characteristics of the Natural Convection Type Radiator by using the PCMs (PCM물질을 적용한 자연대류형 방열기의 방열특성에 관한 실험적 연구)

  • Sung, Dae-Hoon;Kim, Min-Jun;Kim, Joung-Ha;Yun, Jae-Ho;Kim, Woo-Seung;Peck, Jong-Hyeon
    • Proceedings of the SAREK Conference
    • /
    • 2008.06a
    • /
    • pp.1155-1160
    • /
    • 2008
  • In the present study investigated the heat dissipation characteristics of the natural convection type radiator by using the latent heat from a solid-liquid PCM(Phase Change Material). Total radiator volume size is $423{\times}295{\times}83\;mm$ and PCM tank size is $398{\times}270{\times}26\;mm$. The objective was elapsed time lower than maximum operating temperature. Experimental condition, in order to study the effects of the phase-change phenomenon, carried out the various mass flow rate, input electric power, and heat of fusion temperature of two type PCMs. For the above experimental conditions, the cooling performance by using the latent heat showed that heat absorption rate performs for about 3 hours from using PCM $38^{\circ}C$. However, cooling performance by using PCM $50^{\circ}C$ showed higher than surface temperature of heater block because of heat of fusion.

  • PDF

Renal Effects of Chronic Treatment Of Adenosine Analogues (Adenosine 수용체 작동제 장기 투여의 신장효과)

  • Kim Tack-Hee;Kim Suhn-Hee;Huh Jong;Cho Kyung-Woo
    • The Korean Journal of Physiology and Pharmacology
    • /
    • v.1 no.3
    • /
    • pp.325-335
    • /
    • 1997
  • Evidence for the existance of at least two subclasses of renal adenosine receptors has been presented. N-6-cyclohexyladenosine (CHA) is a relatively selective $A_1$ adenosine agonists, whereas 5'-N-ethylcarboxamidoadenosine (NECA) acts as a preferential agonist of $A_2$ adenoisne receptor. N6-(L-2-phenylisoproryl)-adenosine (PIA) almost unselectively activates both $A_1\;and\;A_2$ adenosine receptors at micromolar concentrations. During the characterization of adenosine receptor in the kidney, we have discovered a novel phenomenon, that is, an intramuscular administration of CHA for 3 days caused a diuresis and a suppression of urinary concentrating ability. To further characterize this novel phenomenon, an intramuscular administration of adenosine and other adenosine angonists, PIA and NECA, and prior treatment of adenosine antagonists, caffeine, theophylline and 1,3-diethyl-8-phenyl-xanthine (DPX) were performed. Systemic administration of CHA, PIA, and NECA for 3 days caused a suppression in heart rate, blood pressure and general motor activity without change in rectal temperature. Systemic administration of CHA, 0.5, 1 and 2 mg/kg/day, for 3 days caused a dose-dependent increase in urine volume and decrease in urinary osmolarity and free water reabsorption. This phenomenon was reversible and repeatable. Administration of adenosine (40 mg/kg/day) produced no apparent effect on the renal function, whereas PIA (2 mg/kg/day) produced an similar effect to CHA on the renal function. Systemic adminstration of NECA, 0.025, 0.05 and 0.25 mg/kg/day, for 3 days caused a dose-dependent increase in urine volume and dose-dependent increases in excreted amount of creatinine, urinary osmolarity and free water reabsorption. These renal effects of adenosine agonist were maximum at second day during the drug administration. In terms of increase in urine volume and the suppression of urinary concentrating ability, NECA was potent than CHA. Prior treatment of caffeine (50 mg/kg/day) or theophylline (50 mg/kg/day) abolished the diuretic effect of CHA, whereas DPX (50 mg/kg/day) did not affect the CHA effect. CHA, 0.5 mg/kg/day, produced no change in plasma renin activity and plasma levels of aldosterone, epinephrine, and norepinephrine. These results suggest that this novel phenomenon produced by an activation of renal adenosine receptors plays an important role in urinary concentrating mechanism.

  • PDF

Performance Comparison of SCTP and TCP over Linux Platform (리눅스 환경에서 SCTP와 TCP 프로토콜의 성능 비교)

  • Park, Jae-Sung;Koh, Seok-Joo
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.33 no.8B
    • /
    • pp.699-706
    • /
    • 2008
  • This paper compares throughput performance of TCP and SCTP in a variety of network environments. For experiments, we construct a Linux-based testbed and consider a set of performance metrics such as MSS(Maximum Segment Size), transmission delay, and packet loss rate. In addition, we analyze the effect of SCTP multi-streaming on throughput. From the experimental results, we can see that SCTP provides throughput gain of approximately $20%{\sim}50%$ over TCP. This performance gain comes from the distinctive features of SCTP such as chunk bundling, initial congestion window of 2 MTU and SACK(Selective ACK) based error control. In the lossy networks, we can see that SCTP multi-streaming transmissions can effectively overcome the so-called HoLB(Head-of-Line Blocking) phenomenon of TCP.

Characteristics on Variation of Temperature and Ozone Concentration during the Partial Solar Eclipse Event of 22 July 2009 at Busan (2009년 7월 22일 부분일식 발생 시 부산지역 기온과 오존농도의 변화 특성)

  • Jeon, Byung-Il;Oh, In-Bo
    • Journal of Environmental Science International
    • /
    • v.20 no.8
    • /
    • pp.1049-1059
    • /
    • 2011
  • This paper examines the effects of the partial solar eclipse of 22 July 2009 across the Korean peninsular on surface temperature and ozone concentrations in over the Busan metropolitan region (BMR). The observed data in the BMR demonstrated that the solar eclipse phenomenon clearly affects the surface ozone concentration as well as the air temperature. The decrease in temperature ranging from 1.2 to $5.4^{\circ}C$ was observed at 11 meteorological sites during the eclipse as a consequence of the solar radiation decrease. A large temperature drop exceeding $4^{\circ}C$ was observed at most area (8 sites) of the BMR. Significant ozone drop (18~29 ppb) was also observed during the eclipse mainly due to the decreased efficiency of the photochemical ozone formation. The ozone concentration started to decrease at approximately 1 to 2 hours after the event and reached its minimum value for a half hour to 2 hours after maximum eclipse. The rate of ozone fall ranged between 0.18 and 0.49 ppb/min. The comparison between ozone measurements and the expected values derived from the fitted curve analysis showed that the maximum drop in ozone concentrations occurred at noon or 1 PM and was pronounced at industrial areas.

Study on application of recycled insulation-panel with fire-safety performance (화재성능이 확보된 재생 폐자원 단열재의 활용 연구)

  • Park, Kye-Won;Jeong, Jae-Gun;Kim, Hak-Yong
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 2010.10a
    • /
    • pp.167-170
    • /
    • 2010
  • This study is aiming at analyzing correlation between flashover's time and maximum smoke production rate's time on sandwich panel specimens. For this analysis, KS F ISO 137481-1 has been performed for 23 kinds of sandwich panels which mainly consist of EPS, PIR, PUR, Glass wool and so on. KS F ISO 13784-1 represents real scale reaction-to-fire test and focuses on measuring flashover phenomenon rather than other tests as like ISO 5660-1 and SBI.

  • PDF

The Rate Maxima and Hammett Correlation for the Nucleophilic Substitution (친핵성 치환반응에서 최대속도현상과 Hammett상관관계)

  • 성대동;임귀택
    • The Korean Journal of Food And Nutrition
    • /
    • v.8 no.3
    • /
    • pp.172-183
    • /
    • 1995
  • The nucleophilic substitution reactions of p-substituted benzyl bromide with l-substituted N,N-dimethylanilines in methanol and acetonitrile binary solvent mixture which is known to an isodielectric solvent system kinetically and the results are as follows. The positive charge is developed on the reaction center of the substrate and it means that the bond cleavage is preceded more than bond formation in the transition state on the analogy of Hammett px values. The bond form3tlon is not progressed in the case of electron donating substituent of substrate. However, the bond formation is much developed in the case of electron withdrawing substituent of substrate on the analogy of Hammett py values. The nucleophilic attacking ability is shown a highest at 80% (V/V) methanol content and the bond formation is well progressed at the same methanol composition on the result of a cross interaction coefficient, pxy. The result of transition state structure that is applicated to the potential energy surface model is in accord with the result that Is applicated to the reaction susceptibilities. The reaction Is subject to the polarity-polarizability term more than the hydrogen bond donor acidity term by application to the solvatochromic parameter eouation.

  • PDF

Cavitation-Erosion Characteristics between Polymer Based Composites and Metals under the Various Condition of Fluid Systems (유체 환경하에서의 고분자 기지 복합재료와 금속재의 캐비테이션 침식 특성)

  • Kim, Yun-Hae;Son, Young-Jun;Eum, Soo-Hyun;Lee, Jung-Ju
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.27 no.3
    • /
    • pp.363-371
    • /
    • 2003
  • This study is mainly concerned with phenomenon of cavitation-erosion on the several materials and corrosive liquids which were applied with vibrator(suggested by ASTM G 32, 20KHz, 50$mu extrm{m}$). The maximum erosion rate by cavitation erosion in both of distilled water and sea water appeared to be proportioned to their hardness and tensile strength. Cavitation weight loss and rate of cast iron in sea water condition were greater(approximately 3 times) than that in distilled water condition, however in case of stainless steel and brass the cavitation weight loss of composite materials were not so different in both of their conditions. Cavitation weight loss of composite materials were shown as below on this test, Duratough DL : Weight loss in sea-water condition were greater (approximately 2.3 times) than it's distilled water condition. The main tendency of cavitation erosion for metals appeared that small damaged holes causing by cavitation erosion was observed with radial pattern. On the other hand, the tendency for composites appeared that small damaged holes were observed randomly.

Minimizing of Cavitation-Erosion Damage for Various Structures using Composites under the various Condition of Fluid Flow Systems (복합재료를 이용한 유동유체 환경하의 각종 구조물의 캐비테이션 침식손상의 최소화 방안)

  • 이정주;김찬공;김용직;김윤해
    • Proceedings of the Korean Society For Composite Materials Conference
    • /
    • 1999.11a
    • /
    • pp.227-233
    • /
    • 1999
  • This study is mainly concerned with phenomenon of cavitation-erosion on the several materials and corrosive liquids which were applied with vibrator (suggested by ASTM G-32, 20KHZ, 24{$mu}m$).The main results obtained are summarized as follows ; (1) The maximum erosion rate by cavitation erosion in both of fresh-water and sea-water appeared to be proportioned to their hardness and tensile strength. (2) Cavitation weight loss and rate of cast iron in sea-water condition were greater (approximately 3 times) than that in distilled-water condition, however in case of stainless and brass the cavitation weight loss and their rates were not so different in both of their conditions. (3) Cavitation weight loss of composite materials were shown as below on this test, DuraTough DL : Weight loss in sea-water condition were greater (approximately 2.3 times) than it's fresh-water condition. (4) As the result of observation with digital camea of specimens, the main tendency of cavitation erosion for metals, was that small damaged holes causing by cavitation e개sion was appeared with radial pattern, and composites materials was that small damaged holes were appeared randomly.

  • PDF

Study on the Performance Optimization of Commercial Metal Hydride Refrigerator Powered by Exhaust Gas from Micro Gas Turbine (마이크로가스터빈의 부하에 따른 상용 수소흡장냉동기의 성능 최적화에 관한 연구)

  • Kim Hyoungsik;Sohn Wha-seung;Choi Kyoung-shik
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.17 no.9
    • /
    • pp.824-829
    • /
    • 2005
  • MHR(Metal Hydride Refrigerator) powered by MGT exhaust gas is investigated to find out the optimum conditions corresponding to MGT operating powers. There are many factors to affect cooling capacity of MHR. In this study, the effect of switching time, flow rate of brine on cooling temperature and capacity is investigated. The present results show (1) hydrogen reaction is saturated with 25 min switching time at 25 kW MGT power, (2) cooling power shows maximum phenomenon with increasing switching time, (3) optimum switching times are 20 minutes for 15kW MGT power and 15 minutes for 20, 25kW MGT power, (4) according to increasing brine flow rate, cooling capacity shows decrease at 15 kW MGT power and changes little at above 20 kW MGT power.

A Study on Change in Window Transmitted Solar and the Resultant Wall Surface Convective Heat Gain with Regard to Slat Reflectance of External and Internal Blinds (실내·외 블라인드의 Slat 반사율에 따라 창호 일사투과량 및 그에 따른 벽체 대류열획득량 분석)

  • Hyun, In-Tak;Lee, Jae-Ho;Yoon, Yeo-Beom;Lee, Kwang Ho
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.26 no.12
    • /
    • pp.565-571
    • /
    • 2014
  • Nowadays, to make buildings light weight and aesthetically pleasing, curtain wall structure are commonly used. Therefore, window to wall ratio is increasing, which has caused cooling and heating load in crease in buildings as well. This phenomenon has negative impact from energy point of view. This paper analyzes window and wall convective heat gain when the slat reflectance of external and internal blinds are changed for the better understanding of the fundamentals behind the phenomena. It was observed that, if slat reflectance is increased, window transmitted solar increases and convection heat rate is clearly affected. Among six surfaces including four walls, ceiling and floor, maximum convection heat rate occurs on the south wall in summer. On the other hand, ceiling and floor showed the lowest convection heat gain, since they are shared by adjacent floors.