• 제목/요약/키워드: maximum power point

검색결과 914건 처리시간 0.028초

몰드변압기의 공기덕트의 구조 변화에 따른 온도특성 해석 (Analysis of Temperature Characteristic According to Variation of Air Duct of the Cast Resin Transformer)

  • 김지호;이향범;손진근
    • 전기학회논문지P
    • /
    • 제64권4호
    • /
    • pp.256-260
    • /
    • 2015
  • In this paper, achieved rise temperature distribution about degradation phenomenon of 24 MVA distribution cast resin transformer using CFD(Computational Fluid Dynamics). Usually, life of transformer is depended on temperature distribution of specification region than thermal special quality of transformer interior. Specially, life of transformer by decline of dielectric strength decreases rapidly in case rise by strangeness transformer interior hot spot temperature value permits. Because calculating high-voltage(HV) winding and low-voltage(LV) winding of cast resin transformer and Joule's loss of core for improvement these life, forecasted heat source, and HV winding and LV winding of cast transformer rise temperature distribution of core for supply of electric power and temperature distribution of highest point on the basis of the results. Also, calculated temperature rise limit of cast resin transformer and permission maximum temperature using analysis by electromagnetic heat source. Calculated and forecasted rise temperature distribution by heat source of thermal analysis with calculated result.

Piezo Film Sensor를 이용한 생체 정보 검출 (Detection the Biomedical Information using the Piezo Film Sensor)

  • 이한욱;서환;정원근;장두봉;이건기
    • 한국정보전자통신기술학회논문지
    • /
    • 제3권3호
    • /
    • pp.14-21
    • /
    • 2010
  • 유비쿼터스 헬스케어 환경을 위해서는 생체 정보를 실시간으로 정확하게 측정하는 것이 중요할 뿐만 아니라, 이러한 생체 정보 측정 장치는 저전력으로 설계되어져야 한다. 본 논문에서는 지금까지 사용되어 오던 손가락 프로브의 불편함을 없애기 위해 피에죠 필름 센서를 이용하여 손목의 요골 동맥으로부터 심장의 동기 신호인 맥파를 측정하였다. 본 논문에서는 두장의 피에죠 필름 센서를 이용하여 맥파신호와 동잡음 참조 신호를 추출하여 적응 잡음 제거기에 적용함으로써, 동잡음 제거된 맥파 신호를 얻을 수 있었다. 동잡음 제거된 맥파 신호를 이용하여 생체 정보를 얻을 수 있었다.

  • PDF

DC chopper용 전류회로 개선에 관한 연구 (A study on the improvement of communiation circuit for DC chopper)

  • 노창주;오진석
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제13권1호
    • /
    • pp.57-68
    • /
    • 1989
  • This paper treats the analytical and experimental studies on the improvement of commutating circuit for the speed control of DC motor. A simple circuit composed of R, L and C elements is proposed here for switching off power SCR carrying the load current. The real important in this chopper circuit is to determine the reasonable values of commutating circuit constants. In this paper, the reasonable values of the commutating circuit constants are basically determined on a view point of commutating performances in the given circuit model and must satisfy the following conditions. The first, the peak commutating current should be larger than the anticipated maximum load current. The second, the circuit turn-off time (tc) must be longer than the SCR turn-off time (tq). The third, the resistor should be enough large to permit the current to be neglected in the analysis of the commutation circuit, as well as be enough small to permit to charge the capacity voltage (Ec) to the half the value of source voltage (E) before the next communication cycle is initiated. The last, the period of chopping signal must be the least possible multiple of the damping vibration period of commutating circuit. The improved chopper circuit used in the experiment under unloaded condition was composed to meet the reasonable conditions mentioned above, and a successful commuting performance was achieved without failure. Several types of microprocessor having a different value of CPU speed individually have been applied to the experiment under the loaded conditions. Also it shows that the faster the speed of CPU is, the more stable the commutation turns out.

  • PDF

수소연료전지자동차용 절연저항 측정시스템 개발에 관한 연구 (Study on Development of the Isolation Resistance Measurement System for Hydrogen Fuel Cell Vehicle)

  • 이기연;김동욱;문현욱;김향곤
    • 전기학회논문지
    • /
    • 제60권5호
    • /
    • pp.1068-1072
    • /
    • 2011
  • Hydrogen Fuel Cell Vehicle(HFCV) is system that uses electrical energy of fuel cell stack to main power source, which is different system with other vehicles that use high-voltage, large-current. Isolation performance of this system which is connected with electrical fire and electrical shock is important point. Isolation resistance of electric installation is divided according to working voltage, it follows criterion more than $100{\Omega}$/VDC (or $500{\Omega}$/VAC) about system operation voltage in a hydrogen fuel cell vehicle. Although measurement of isolation resistance in a hydrogen fuel cell vehicle is two methods, it uses mainly measurement by megger. However, the present isolation resistance measurement system that is optimized to use in electrical facilities is unsuitable for isolation performance estimation of a hydrogen fuel cell vehicle because of limit of maximum short current and difference of measurement resolution. Therefore, this research developed the isolation resistance measurement system so that may be suitable in isolation performance estimation of a hydrogen fuel cell vehicle, verified isolation performance about known resistance by performance verification of laboratory level about developed system, and executed performance verification through comparing results of developed system by performance verification of vehicle level with ones of existing megger. Developed system is judged to aid estimation and upgrade of isolation performance in a hydrogen fuel cell vehicle hereafter.

The capacity loss of a RCC building under mainshock-aftershock seismic sequences

  • Zhai, Chang-Hai;Zheng, Zhi;Li, Shuang;Pan, Xiaolan
    • Earthquakes and Structures
    • /
    • 제15권3호
    • /
    • pp.295-306
    • /
    • 2018
  • Reinforced concrete containment (RCC) building has long been considered as the last barrier for keeping the radiation from leaking into the environment. It is important to quantify the performance of these structures and facilities considering extreme conditions. However, the preceding research on evaluating nuclear power plant (NPP) structures, particularly considering mainshock-aftershock seismic sequences, is deficient. Therefore, this manuscript serves to investigate the seismic fragility of a typical RCC building subjected to mainshock-aftershock seismic sequences. The implementation of the fragility assessment has been performed based on the incremental dynamic analysis (IDA) method. A lumped mass RCC model considering the tri-linear skeleton curve and the maximum point-oriented hysteretic rule is employed for IDA analyses. The results indicate that the seismic capacity of the RCC building would be overestimated without taking into account the mainshock-aftershock effects. It is also found that the seismic capacity of the RCC building decreases with the increase of the relative intensity of aftershock ground motions to mainshock ground motions. In addition, the effects of artificial mainshock-aftershock ground motions generated from the repeated and randomized approaches and the polarity of the aftershock with respect to the mainshock on the evaluation of the RCC are also researched, respectively.

A Study of the 3D Unmanned Remote Surveying for the Curved Semi-Shield Tunneling

  • Lee, Jin-Yi;Jun, Jong-Woo
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 2005년도 ICCAS
    • /
    • pp.1791-1796
    • /
    • 2005
  • Semi-shield tunneling is one of the propulsion construction methods used to lay pipes underground between two pits named 'entrance' and 'destination', respectively. Usually a simple composition, such as 'a fiducial target at the entrance+a total station (TS)+a target on the machine', is used to confirm the planned course. However, unavoidable curved sections are present in small-sized pipe lines, which are laid after implementation of a road system, for public works such as waterworks, sewer, electrical power, and gas and communication networks. Therefore, if the planned course has a curved section, it is difficult to survey the course with the abovementioned simple composition. This difficulty could be solved by using the multiple total stations (MTS), which attaches the cross type linear LED target to oneself. The MTS are disposed to where each TS can detect the LED target at the other TS or the base point or the machine. And the accurate relative positions between each MTS and target are calculated from measured data. This research proposes the relative and absolute coordinate calculation algorithm by using three MTS to measure a curved course with 20m curvature at 30m maximum distance, and verifies the algorithm experimentally.

  • PDF

개인휴대통신을 위한 이동국 RF 수신시스템의 설계 및 성능개선에 관한 연구 (A study on the RF receiving system design and on the performance improvement for PCS mobile station)

  • 오정일;천종훈
    • 전자공학회논문지C
    • /
    • 제34C권11호
    • /
    • pp.66-75
    • /
    • 1997
  • We derive the system design parameters to implement the receiving system for the PCS mobile station to satisfy the J-sTD-018 which is the PCS mobile station(MS) minimum performance. Also we analyze the system performance and intermodulation spurious due to the values of a device cause the system performance degradation, is proposed. The simulation shows the receiver's maximum system noise figure to satisfy the receiver selectivity is approximately 11 dB. While the MS noise figure is 10dB with system margin 1 dB, the minimum selectivity is -71 dB at 1.25MHz frequency offset from the carrier frequency. And the input 3rd order intercept point of the MS class I and the MS class II~V is -9.5 dBm and -14dBm respectively. When the interference power level at the receiver is small, the receiver has better performance as we increase the gain of the LNA. However, when the interference level at the receiver is large, the receiver performance is heavily affected by the spurious as we increase the gain of the LNA. Thus, we proved the effectiveness of the LNA On/Off switching technique as to reduce the effect of the spurious.

  • PDF

태양광용 부스트 컨버터의 2중 루프 제어 및 단일 루프 제어의 특성 비교 (Comparative Study between Two and Single-loop Control of Boost Converter for PVPCS)

  • 김동환;임지훈;송승호;최주엽;안진웅;이상철;이동하
    • 한국태양에너지학회:학술대회논문집
    • /
    • 한국태양에너지학회 2012년도 춘계학술발표대회 논문집
    • /
    • pp.153-159
    • /
    • 2012
  • In photovoltaic system, the characteristic of photovoltaic module such as open circuit voltage and short circuit current will be changed because of cell temperature and solar radiation. Therefore, a boost converter of the PV system connects between the output of photovoltaic system and DC link capacitor of grid connected inverter as controlling duty ratio for maximum power point tracking(MPPT). This paper shows the dynamic characteristic of the boost converter by comparing single-loop control algorithm and two-loop control algorithm using both analog and digital control. The proposed both compensation method has been verified with computer simulation and simulation results obtained demonstrate the validity of the proposed control schemes.

  • PDF

A Transimpedance Amplifier Employing a New DC Offset Cancellation Method for WCDMA/LTE Applications

  • Lee, Cheongmin;Kwon, Kuduck
    • JSTS:Journal of Semiconductor Technology and Science
    • /
    • 제16권6호
    • /
    • pp.825-831
    • /
    • 2016
  • In this paper, a transimpedance amplifier based on a new DC offset cancellation (DCOC) method is proposed for WCDMA/LTE applications. The proposed method applies a sample and hold mechanism to the conventional DCOC method with a DC feedback loop. It prevents the removal of information around the DC, so it avoids signal-to-noise ratio degradation. It also reduces area and power consumption. It was designed in a $0.13{\mu}m$ deep n-well CMOS technology and drew a maximum current of 1.58 mA from a 1.2 V supply voltage. It showed a transimpedance gain of $80dB{\Omega}$, an input-referred noise current lower than 0.9 pA/${\surd}$Hz, an out-of-band input-referred 3rd-order intercept point more than 9.5 dBm, and an output DC offset lower than 10 mV. Its area is $0.46mm{\times}0.48mm$.

부하를 고려한 DC-DC 컨버터의 듀티비에 따른 태양광 발전 시스템의 최대전력점 추적 (MPPT of photovoltaic system with duty ratio of DC-DC converter considered load)

  • 전영선;고재섭;최정식;정철호;김도연;정병진;정동화
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 2008년도 춘계학술대회 논문집
    • /
    • pp.407-410
    • /
    • 2008
  • This paper presents a maximum power point tracking(MPPT) of photovoltaic system with duty ratio of DC-DC converter considered load. A variation of solar irradiation is most important factor in the MPPT of PV system That is nonlinear, aperiodic and complicated. NN was widely used due to easily solving a complex math problem. The paper consists of solar radiation source, DC-DC converter, DC motor and load(cf, pump). NN algorithm apply to DC-DC converter through an adaptive control of neural network, calculates converter-duty ratio using an adaptive control of NN. The results of an adaptive control of NN compared with the results of converter-duty ratio which are calculated mathematical modeling and evaluate the proposed algorithm. The experimental data show that an adequacy of the algorithm was established through the compared data.

  • PDF