• 제목/요약/키워드: maximum power angle

검색결과 298건 처리시간 0.027초

태양 입사각에 따른 전력 변화 (Power Change According to the Angle of Solar Incidence)

  • 황미용;응우옌반흥;이순형;최용성
    • 한국전기전자재료학회논문지
    • /
    • 제36권3호
    • /
    • pp.261-265
    • /
    • 2023
  • In this paper, we analyzed the transformation of the power following by the angle of incidence of the solar, the angle of photovoltaic module and artificial solar changed from 30° to 90° and synchronously changed the distance from 0.1 m to 0.5 m. Setting the distance between the artificial solar and the luminometer from 0.1 m to 0.5 m and set the angles to 90°, 60°, 45°, and 30°, the angle was 90° and when the distance was 0.1 m, the maximum Illuminance was 19,580 lux, the light could be obtained more. If the angle of incidence between the Artificial solar and the photovoltaic module was 90° and the variable resistance was 1,000 Ω at a distance of 0.4 m, the maximum power reached 0.82 W. Provided that the angle of incidence between the artificial solar and the photovoltaic module was 90° and the distance was 0.2 m since the variable resistance had the maximum power of 500 Ω, the maximum power was 0.78 W. At 1,000 Ω, the maximum power is 0.80 W so the maximum power at the variable resistance 1,000 Ω could obtain higher power than the variable resistance 500 Ω. The variable resistance was 1,000 Ω and the angle of incidence between the Artificial solar and the photovoltaic module was 90° at a distance of 0.4 m, and the maximum power reached 0.82 W. The angle was 60° at 0.3 m and 0.4 m the maximum power reached 0.10 W. The angle was 45° at 0.2 m maximum power reached 0.020 W, the angle was 30° at 0.4 m, and the maximum power reached 0.004 W. In four results about maximum power depending on the angle of incidence between the artificial solar and the photovoltaic module, the luminous efficiency and maximum power can be got the best at an angle of 90°.

Simulation for Pitch Angle Control Strategies of a Grid-Connected Wind Turbine System on MATLAB/Simulink

  • 노경수;최준호
    • 조명전기설비학회논문지
    • /
    • 제21권1호
    • /
    • pp.91-97
    • /
    • 2007
  • This paper presents a pitch angle controller of a grid-connected wind turbine system for extracting maximum power from wind and implements a modeling and simulation of the wind turbine system on MATLAB/Simulink. It discusses the maximum power control algorithm for the wind turbine and presents, in a graphical form, the relationship of wind turbine output, rotor speed, and power coefficient with wind speed when the wind turbine is operated under the maximum power control algorithm. The objective of pitch angle control is to extract maximum power from wind and is achieved by regulating the blade pitch angle during above-rated wind speeds in order to bypass excessive energy in the wind. Case studies demonstrate that the pitch angle control is carried out to achieve maximum power extraction during above-rated wind speeds and effectiveness of the proposed controller would be satisfactory.

계통연계 풍력발전 시스템의 최대출력 제어를 위한 PI 제어기의 성능 분석 (Performance of PI Controller for Maximum Power Extraction of a Grid-Connected Wind Energy Conversion System)

  • 노경수;류행수
    • 대한전기학회논문지:전력기술부문A
    • /
    • 제51권8호
    • /
    • pp.391-397
    • /
    • 2002
  • This paper presents a modeling and simulation of a PI controller for maximum power extraction of a grid-connected wind energy conversion system with a link of a rectifier and an inverter. It discusses the maximum power control algorithm fnr a wind turbine and proposes, in a graphical form, the relationships of wind turbine output, rotor speed, power coefficient, tip-speed ratio with wind speed when the wind turbine is operated under the maximum power control. The control objective is to always extract maximum power from wind and transfer the power to the utility by controlling both the Pitch angle of the wind turbine blades and the inverter firing angle. Pitch control method is mechanically complicated, but the control performance is better than that of the stall regulation method. The simulation results performed on MATLAB will show the variation of generator's rotor angle and rotor speed, pitch angle, and generator output.

가변 풍력발전 시스템의 최대출력 제어를 위한 Fuzzy 제어기 설계 (A Fuzzy Logic Controller Design for Maximum Power Extraction of Variable Speed Wind Energy Conversion System)

  • 김재곤;허욱열;김병륜
    • 대한전기학회논문지:시스템및제어부문D
    • /
    • 제53권11호
    • /
    • pp.753-759
    • /
    • 2004
  • This paper presents a modeling and simulation of a fuzzy controller for maximum power extraction of a grid-connected wind energy conversion system with a link of a rectifier and an inverter. It discusses the maximum power control algorithm for a wind turbine and proposes, in a graphical form, the relationships of wind turbine output, rotor speed, power coefficient, tip-speed ratio with wind speed when the wind turbine is operated under the maximum power control. The control objective is to always extract maximum power from wind and transfer the power to the utility by controlling both the pitch angle of the wind turbine blades and the inverter firing angle. Pitch control method is mechanically complicated, but the control performance is better than that of the stall regulation method. The simulation results performed on MATLAB will show the variation of generator's rotor angle and rotor speed, pitch angle, and generator output.

가변 풍력발전 시스템의 최대출력 제어를 위한 Fuzzy 제어기 설계 (A fuzzy logic Controller design for Maximum Power Extraction of variable speed Wind Energy Conversion System)

  • 김재곤;김병륜;허욱열
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2004년도 하계학술대회 논문집 D
    • /
    • pp.2307-2309
    • /
    • 2004
  • This paper presents a modeling and simulation of a fuzzy controller for maximum power extraction of a grid-connected wind energy conversion system with a link of a rectifier and an inverter. It discusses the maximum power control algorithm for a wind turbine and proposes, in a graphical form, the relationships of wind turbine output, rotor speed, power coefficient, tip-speed ratio with wind speed when the wind turbine is operated under the maximum power control. The control objective is to always extract maximum power from wind and transfer the power to the utility by controlling both the pitch angle of the wind turbine blades and the inverter firing angle. Pitch control method is mechanically complicated, but the control performance is better than that of the stall regulation method. The simulation results performed on MATLAB will show the variation of generator's rotor angle and rotor speed, pitch angle, and generator output.

  • PDF

SRM의 최대 토크, 효율 및 최소 토크리플 운전을 위한 스위칭 각 (Switching Angle for Maximizing Torque, Efficiency and Minimizing Torque Ripple in SRM Drive)

  • 김현덕;차현록;김광헌;나석환;임영철
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 1999년도 전력전자학술대회 논문집
    • /
    • pp.151-154
    • /
    • 1999
  • This paper presents a driving method of 3-phase 4-poles SRM(switched reluctance motor) drived by switching angle control. In this study, the switching angle is determined from approximated analysis and computer simulation by using MATLAB for high efficiency according to the speed and torque required by load, and then microcontroller controls the switching angle of asymmetrical inverter in SRM driver. Also, we experiment the maximum forque driving and maximum power driving by controlling switching angle available to electric vehicle.

  • PDF

저온도차 모형 스털링 엔진의 최대출력 설계조건 (DESIGN OF A LOW TEMPERATURE DIFFERENCE STIRLING ENGINE)

  • 정평석;원민영;김수연
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2003년도 추계학술대회
    • /
    • pp.420-423
    • /
    • 2003
  • A low temperature difference model Stirling engine is a small Stirling engine running with several degree of temperature difference without power output. In this study, the design parameters to give maximum power are discussed. As results, the phase angle is about 100 degree, and compression ratio is 1.5% of the ratio of heat source temperatures at maximum power condition.

  • PDF

A Study on Voltage and Switching Angle for Maximum Torque/Efficiency and Minimum Torque Ripple of SRM by using SIMULINK$^\textregistered$

  • Cha, Hyun-Rok;Seo, Jong-Yun;Yang, Hyong-yeol;Kim, Kwang-Heon;Lim, Young-Cheol;Jang, Do-Hyun
    • Journal of Power Electronics
    • /
    • 제1권1호
    • /
    • pp.56-64
    • /
    • 2001
  • This paper presents the switching angle and voltage for maximizing the torque or efficiency and minimizing torque ripple of an 8/6, SRM. The approximate analysis and computer simulation determine the switching angle and voltage by using SIMULINK$^\textregistered$. This is performed as a function of the speed and torque required by the load. From the results, new three facts can be known: First, the maximum torque depends on voltage and speed depends on switching angle. The others, the maximum efficiency and minimum torque ripple relay on switching angle. We control the switching angle and voltage of and asymmetrical inverter for the SRM with one-chip micro controller.

  • PDF

고속 고출력 영구자석 전동기 최대 출력 운전에 관한 연구 (Study of high speed and high torque performance of brushless DC motor drive for maximum power)

  • 빈재구;김철우
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2006년도 전력전자학술대회 논문집
    • /
    • pp.122-124
    • /
    • 2006
  • ADD is under development for the high speed motor. This paper describes simulation and test results for obtaining the maximum output by leading angle of encoder. So we carried out the test for obtaining the optimum leading angle of encoder. Test results on the motor of 7 phases 6 poles were showed the validity of proposed methods and phase-leading angle.

  • PDF

A Numerical Study on the Effect of Inlet Guide Vane Angle on the Performance of Francis Hydraulic Turbine

  • Kim Chul-Ho
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제29권7호
    • /
    • pp.750-757
    • /
    • 2005
  • The objective of this study is an understanding of the effect of inlet flow angle on the output power performance of a Francis hydraulic turbine, An optimum induced angle at the inlet of the turbine is one of the most important design parameters to have the best performance of the turbine at a given operating condition, In general. rotating speed of the turbine is varied with the change of water mass flowrate in a volute, The induced angle of the inlet water should be properly adjusted to the operating condition to have maximum energy conversion efficiency of the turbine, In this study. a numerical simulation was conducted to have detail understanding of the flow phenomenon in the flow path and output power of the model Francis turbine. The indicated power produced by the model turbine at a given operating condition was found numerically and compared to the brake power of the turbine measured by experiment at KIER. From comparison of two results, turbine efficiency or energy conversion efficiency of the model turbine was estimated. From the study, it was found that the rotating power of the turbine linearly increased with the rotating speed. It means that the higher volume flow rate supplied. the bigger torque on the turbine shaft generated. The maximum brake efficiency of the turbine is around 46$\%$ at 35 degree of induced angle. The difference between numerical and experimental output of the model turbine is defined as mechanical efficiency. The maximum mechanical efficiency of the turbine is around 93$\%$ at 25$\∼$30 degree of induced angle.