• Title/Summary/Keyword: maximum flow rate

Search Result 1,164, Processing Time 0.032 seconds

Clinical Analysis on Relation Between Blood Flow and Patency af Arteriovenous Fistula for Hemodialysis (혈액투석을 위한 동정맥류 조성술후 혈류량과 동정맥루 개존에 관한 임상적 고찰)

  • 김창회
    • Journal of Chest Surgery
    • /
    • v.24 no.12
    • /
    • pp.1167-1172
    • /
    • 1991
  • Since March 1988 we have performed 133 arteriovenous fistulae for hemodialysis in 121 patients with chronic renal failure. Of the 133 cases of arteriovenous fistulae, follow-up evaluation was possible for 80 cases which performed in 69 patients. The relation between blood flow and patency rate and duration of arteriovenous fistula was examined. The overall 6 - 12 - 18 -, and 24 - month patency rates of arteriovenous fistulae were 82%, 64%a, 62%, and 57%, respectively. The maximum blood flow was 150 ~ 350ml /min[mean 217.1$\pm$44.27]. The patency duration was evaluated in patients divided into three groups owing to maximum blood flow through the fistulae. The range of maximum blood flow was 150 ~ 200ml /min for group A, 200 ~ 250ml /min for group B, and above 250ml /min for group C. The mean duration of the patency was 10.7$\pm$7.60 months in group A, 14.9$\pm$9.82 months in group B, and 21.6$\pm$11.16 months in group C[p<0 05]. With increased maximum blood flow, the duration of the patency was longer in group A than group B and C [r=0.39, p<0. 05]. The maintenance blood flow was 100 ~ 250ml /min[mean 179.2$\pm$37.26 ml/min]. When the maintenance blood flow was above 200ml /min, long-term patency rate was higher than the group below 200ml /min[r=0.48, p<0.01]. In the same range of blood flow, patency duration of the patients with using their own blood vessels were longer than the patients with using vascular graft for A-V fistula. We concluded that the patency of the arteriovenous fistulae was closely correlated with the blood flow through the fistulae.

  • PDF

Prediction on Flow Stress Curves and Microstructure of 304 Stainless Steel (304 스테인리스강이 고온 유동응력곡선과 미세 조직의 예측)

  • 한형기;유연철;김성일
    • Transactions of Materials Processing
    • /
    • v.9 no.1
    • /
    • pp.72-79
    • /
    • 2000
  • Dynamic recrystallization (DRX), which may occur during hot deformation, is important for the microsturctural evolution of 304 stainless steel. Especially, the current interest in modelling hot rolling demands quantitative relationships among the thermomechanical process variables, such as strain, temperature, strain rate, and etc. Thus, this paper individually presents the relationships for flow stress and volume fraction of DRX as a function of processing variables using torsion tests. The hot torsion tests of 304 stainless steel were performed at the temperature range of 900~110$0^{\circ}C$ and the strain rate range of 5x10-2~5s-1 to study the high temperature softening behavior. For the exact prediction of flow stress, the equation was divided into two regions, the work hardening (WH) and dynamic recovery (DRV) region and the DRX region. Especially, The flow stress of DRX region could be expressed by using the volume fraction of DRX (XDRX). Since XDRX was consisted of the critical strain($\varepsilon$c) for initiation of dynamic recrystallization (DRX) and the strain for maximum softening rate ($\varepsilon$*), that were related with the evolution of microstructure. The calculated results predicted the flow stress and the microstructure of the alloy at any deformation conditions well.

  • PDF

A Study on the Deposition Condition for Stoichimetric $\textrm{Ta}_2\textrm{O}_5$ Thin Films by DC Magnetron Reactive Sputtering Technique (DC Magnetron 반응성 스퍼터링 방법을 이용한 stoichiometric $\textrm{Ta}_2\textrm{O}_5$막의 증착조건에 관한 연구)

  • Jo, Seong-Dong;Baek, Gyeong-Uk
    • Korean Journal of Materials Research
    • /
    • v.9 no.6
    • /
    • pp.551-555
    • /
    • 1999
  • The deposition condition to obtain stoichiometric $Ta_2$O\ulcorner films, which is still controversial, using magnetron reactive sputtering was studied. The films were deposited by varying $O_2$gas flow rate with sputtering power and Ar gas flow rate of 200W and 60 sccm fixed. At the conditions of $O_2$ gas flow rate over 20 sccm, amorphous Tantalum oxide films with the refractive index of 2.1 and dielectric constant of 25 were deposited. Among those films, the capacitors dielectric properties of the film deposited at the condition of $O_2$ gas flow rate 50 sccm was best, the leakage current was 1$\times$10\ulcornerA/$\textrm{cm}^2$ at the electric field strength of 0.5 MC/cm and the breakdown field strength was over 2.0 MV/cm. This result could be explained from the analysis comparing with a standard sample using RBS because the composition of the film deposited at this condition was closest to the stoichiometric $Ta_2$O\ulcorner. The result of XPS analysis convinced that this film was stoichiometric $Ta_2$O\ulcorner film. A maximum cathode voltage was observed when $O_2$gas flow rate was 30 sccm. This shows that the Schiller's proposition that one can obtain stoichiometric films at the condition of maximum cathode voltage is not correct and more oxygen than that of the maximum voltage condition is necessary to deposit the stoichiometric Ta$_2$O\ulcorner films.

  • PDF

Effect of the yield criterion on the strain rate and plastic work rate intensity factors in axisymmetric flow

  • Lyamina, Elena A.;Nguyen, Thanh
    • Structural Engineering and Mechanics
    • /
    • v.58 no.4
    • /
    • pp.719-729
    • /
    • 2016
  • The main objective of the present paper is to study the effect of the yield criterion on the magnitude of the strain rate and plastic work rate intensity factors in axisymmetric flow of isotropic incompressible rigid perfectly plastic material by means of a problem permitting a closed-form solution. The boundary value problem consisting of the axisymmetric deformation of a plastic tube is solved. The outer surface of the tube contracts. The radius of the inner surface does not change. The material of the tube obeys quite a general yield criterion and its associated flow rule. The maximum friction law is assumed at the inner surface of the tube. Therefore, the velocity field is singular near this surface. In particular, the strain rate and plastic work rate intensity factors are derived from the solution. It is shown that the strain rate intensity factor does not depend on the yield criterion but the plastic work rate intensity factor does.

Observation of Reservoir Current Using Drifter (The Case Study of Yongdam Reservoir) (Drifter를 이용한 저수지 수리거동 조사 (용담댐을 중심으로))

  • Lee, Yo-Sang;Koh, Deok-Koo;Chae, Hyo-Sok;Han, Kyung-Min
    • Korean Journal of Ecology and Environment
    • /
    • v.45 no.2
    • /
    • pp.200-209
    • /
    • 2012
  • The current of the water body is very important information for the water quality management on reservoirs. It is applied to hydraulics and water quality model for simulation. In this regard, the current characteristic of water body is the basic information that can be used to predict various conditions. However, it is very slow flowing and is affected by the reservoir operations and external factors. As such, an accurate measurement of the current is a difficult problem. In order to measure the water current, we constructed a drifter. According to the result of flow survey at Yongdam reservoir, 5m and 10 m depth layer flow was investigated from the upstream to the downstream, during a flood period. Maximum flow rate of 5 m depth is 13.8 cm $sec^{-1}$ and 10 m depth shows 4 cm $sec^{-1}$, respectively. But 2m depth shows a backward flow and maximum flow rate is 4 cm $sec^{-1}$. Density currents flow plays the role of back flow in reservoirs. Flow velocity in the reservoir was measured in the range of 1~2 cm $sec^{-1}$, at normal flow season, and the flow direction were different for each survey. This phenomenon occurs because the reservoir volume is very large, compared to the inflow and outflow volume.

A Method for Improving Air Distribution Performance at the Residence Ventilation System (주거 환기 시스템의 공기 분배 성능 개선 방안)

  • Park, Eun-Jun;Kim, Yong-Bong;Na, Hee-Hyoung;Lee, Sang-Ki
    • Proceedings of the SAREK Conference
    • /
    • 2007.11a
    • /
    • pp.589-593
    • /
    • 2007
  • In the mechanical ventilation system, it is a fundamental condition to distribute the air equally to the each room. In this study, distribution performance of the air distributor which generally connected to a circular duct was investigated by simulation and experiment. In the first CFD analysis, maximum air flow rate deviation was an 63% in the air distributor model. After numbers of model modification and simulation, maximum flow rate deviation was reduced to 19% in the final simulation model. An air distributor which used in the experiment was produced by using data obtained from the final analysis. When experimental result was compared with analysis result, there was a deviation difference as much as 9%.

  • PDF

A Design Procedure for a Multi-Stage Axial Compressor Using the Stage-Stacking Method (단축적방법을 이용한 다단 축류압축기의 설계)

  • 강동진
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.18 no.6
    • /
    • pp.1598-1603
    • /
    • 1994
  • A preliminary design procedure for a multi-stage axial compressor is developed, which is based on the stage-stacking method. It determines the flow coefficient which gives rise to the design conditions required such as pressure ratio, mass flow rate and rotational speed for a given specific mass flow rate at inlet to a compressor. With this flow coefficient, blade radii, every stage and compressor performance characterics such as stage pressure ratio, adiabatic efficiency etc. are calculated by stacking each stage performance characteristics. It is shown that there is an optimum number of stage which results in the maximum of compressor overall efficiency for a given specific mass flow rate at inlet to a compressor. A test design was tried for three different geometric design constraints, and comparison with a previous study shows that present procedure could be used reliably in determining the number of compressor stage in preliminary design stage.

Characteristics of Electroosmotic Pump with Cylindrical Porous Glass Frits (원통형 다공성 유리막을 이용한 전기삼투 펌프의 연구)

  • Kwon, Kil-Sung;Kim, Dae-Joong
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.36 no.6
    • /
    • pp.619-624
    • /
    • 2012
  • In this study, we demonstrated the operation of an electroosmotic pump with cylindrical porous glass frits and evaluated its long-term operation. The performance of this electroosmotic pump was characterized in terms of maximum flow rate, current, and pressure using deionized water and 1 mM borate buffer. The maximum flow rate, current, and pressure linearly increase with voltage. The maximum flow rate is normalized by the pumping area and voltage for comparison of the performance between the electroosmotic pumps with cylindrical and planar frits. The normalized maximum flow rate of the cylindrical-type pump is higher than that of the planar-type pump because of their different geometries. The cylindrical-type electroosmotic pump has five times better performance than the planartype electroosmotic pump for a given pump package volume. It can operate stably for over 3 hours.

Watershed Selection for Diffuse Pollution Management Based on Flow Regime Alteration and Water Quality Variation Analysis (유황분석과 수질변화 평가를 통한 비점오염원 관리대상지역 선정방법 연구)

  • Jung, Woohyeuk;Yi, Sangjin;Kim, Geonha;Jeong, Sangman
    • Journal of Korean Society on Water Environment
    • /
    • v.27 no.2
    • /
    • pp.228-234
    • /
    • 2011
  • The goal of water quality management on stream and watershed is to focus not on discharged loads management but on a water quality management. Discharged loads management is not goal of water quality management but way for perform with total maximum daily loads management. It is necessary to estimate the relation between non-point source with stromwater runoff (NPSSR) and water quality to select a watershed where it is required to manage NPSSR for water quality improvement. To evaluate the effects of NPSSR on stream's water quality, we compare the aspects of water quality in dry and wet seasons using flow duration curve analysis based on flow rate variation data by actual surveying. In this study we attempt to quantify the variation characteristic of water quality and estimate the Inflow characteristic of pollution source with water quality and flow rate monitoring on 10 watersheds. We try to estimate water quality and flow rate by regression analysis and try again regression analysis with each high and low water quality data more than estimations. An analysis of relation between water quality and flow rate of 10 watersheds shows that the water quality of the Nonsan and the Ganggyeong streams had been polluted by NPSSR pollutants. Other eight streams were important point source more than NPSSR. It is wide variation range of $BOD_5$ also high average concentration of $BOD_5$. We have to quantify water quality variation by cv1 in wet season and cv365 in dry season with comparing the estimate of high water quality and low water quality. This method can be used to indicator for water quality variation according to flow rate.

The Effects of Operational Conditions of Cooling Water System on Energy Consumption for Central Cooling System (냉각수 계통의 운전변수가 중앙냉방시스템의 에너지소비량에 미치는 영향)

  • Ahn, Byung-Cheon
    • Journal of the Korean Society for Geothermal and Hydrothermal Energy
    • /
    • v.13 no.4
    • /
    • pp.8-13
    • /
    • 2017
  • The effects of operational conditions of cooling water system on energy consumption for central cooling system are researched by using TRNSYS program. Cooling tower water pump flow rate, cooling tower fan flow rate, and condenser water temperature with various dry-bulb and wet-bulb temperatures are varied and their effects on total and component power consumption are studied. If the fan maximum flow rates of cooling tower is decreased, cooling tower fan and total power consumptions are increased. If the cooling tower water pump maximum flow rates is decreased, chiller and total power consumptions are increased. If condenser water set-point temperature is increased, chiller power consumption is increased and cooling tower fan power consumption is decreased, respectively.