• Title/Summary/Keyword: maxillary

Search Result 3,284, Processing Time 0.035 seconds

A STUDY ON THE EFFECTIVE PENETRATION OF ETCHING AGENT IN OCCLUSAL PIT & FISSURE (교합면 소와 열구에서 산부식 제재의 효과적인 침투 방법에 대한 연구)

  • Lee, Seong-Ryong;Lee, Sang-Ho;Lee, Chang-Seop;Lee, Nan-Young
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.32 no.3
    • /
    • pp.472-480
    • /
    • 2005
  • The purpose of this study was to investigate the effective penetration methods of acid etching agents in the pit and fissures on the occlusal surface. Extracted maxillary first and second premolars were divided into 4 groups : to Group I only acid etching agent was applied, to Group II ultrasonic scaler as well as acid etching agent were applied, to Group III after fissurotomy acid etching agent was applied, and to Group IV after fissurotomy the same process performed with Group II. The comparison between the 4 groups by the use of scanning electron microscope showed the results as follows : 1. Comparing each groups with regard to the penetration rate(%) of acid etching agents, Group III and Group IV showed improved penetration rate(%) compared with Group I. Group II made no significant different results from Group I, but had somewhat better penetration rate(%). 2. Comparing each groups with regard to the penetration rate(%) of acid etching agents according to regions within fissures, Group III and Group IV showed more improved penetration rate than Group I in the mesial pit and distal pit. However, no significant difference between each groups was showed in the middle fissure.

  • PDF

EVALUATION OF FLUORIDE-RELEASING CAPACITY FROM POLYVINYL ALCOHOL POLYMER TAPE SUPPLEMENTED WITH NAF IN ORAL CAVITY (폴리비닐알코올 기반 고분자 불소 함유 테이프의 구강 내 불소 유리 성능 평가)

  • Lee, Ka-Young;Lee, Sang-Ho;Lee, Nan-Young
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.40 no.2
    • /
    • pp.89-97
    • /
    • 2013
  • The purpose of this study is to investigate fluoride release in the oral cavity from polymer adhesive tape which is NaF coated PVA. 45 healthy adults were divided into 3 groups by the type of topical fluoride applied: 60seconds taste$^{(R)}$ APF gel (group 1), FluoroDose$^{(R)}$ varnish (group 2) and NaF-PVA (group 3). Topical fluoride was applied to the facial surface of maxillary 12 teeth and unstimulated whole saliva was collected to measure fluoride release after 1, 3, 6, 12, 24, and 48 hours. Fluoride-sensitive electrode was used for measuring the fluoride concentration in the saliva samples. All three groups showed significantly higher value for fluoride concentration than the baseline after 1 and 3 hours (p < 0.05). After 6 hours, group 3 showed significantly higher fluoride concentration than the baseline (p < 0.05) and also showed significantly higher value for fluoride concentration than group 1 and group 2. Between group 1 and group 2, however, there was no significant difference statistically with respect to fluoride concentration value (p > 0.05).

The Effect of Human Appendage Muscle Strength on Increase in Vertical Dimension from Intercuspal Position of Mandible (교두감합위로부터 출발한 수직교합고경의 단계적 증가가 사지 근력에 미치는 영향에 관한 연구)

  • Hong, Dong-Hee;Lee, Sung-Bok;Choi, Dae-Kyun
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.19 no.3
    • /
    • pp.169-183
    • /
    • 2003
  • According to our recent investigation that the increase in the occlusal vertical dimension made the appendage muscle strength got higher, the occlusal appliances were made by increasing the occlusal vertical dimension "from the centric relation" position of the mandible. In this experiment, the authors tried to study the change in the appendage muscle strength due to increase in occlusal vertical dimension from intercuspal position(ICP) of mandible with the same subjects and manner as the former experiment. For this study, ten male athletes in a mean age of 23 year who were joined the former study were selected. All the subjects had a complete or almost complete set of natural teeth and reported no subjective symptoms of temporomandibular disorders. Upper and lower casts were mounted on the semi-adjustable articulator at the intercuspal position and a point was marked on the attached gingival area between the right canine and the right 1st. premolar in each upper and lower cast. From the points, the occlusal vertical dimension was increased by 2mm, 3.5mm and 5mm, and then each 10 maxillary type occlusal splint at each 3-increased position were fabricated with heat curing clear acrylic resin. Including the intercuspal position, the 3 kinds of occlusal splints were placed on the subjects individually, and then isokinetic muscle strength on 7 parts of the human appendage which are shoulder, knee, ankle, wrist, forearm, elbow and hip was measured with the CYBEX 6000 SYSTEM (Lumex, NewYork, USA). The results were as follows: The highest mean value in muscular strength was shown at the position of 2mm-increased vertical dimension. The muscle strength during internal/external rotation of shoulder and knee, plantarflexion of ankle, flexion of elbow, and flexion and extension of hip at the increased occlusal vertical dimension position were significantly higher than them at the intercuspal position (p<0.05). Only in view of the increase in the appendage muscle strength, regardless of the way of making the occlusal splints by elevating the occlusal vertical dimension from the centric relation position or intercuspal position, the occlusal splints had an effect on the increase of isokinetic muscle strength at the occlusal vertical dimension which increased within the proper range on the habitual arc of closure.

Evaluation of Tightness of Proximal tooth Contact on Implant Prostheses (임프란트 보철수복물에서의 인접치간 접촉강도의 평가)

  • Kim, Sang-Pil;Jung, J-Hyun;Kang, Dong-Wan;Oh, Sang-Ho
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.24 no.4
    • /
    • pp.371-379
    • /
    • 2008
  • The aim of this study was to evaluate the tightness of proximal tooth contact(TPTC) using a novel device at rest state on implant prostheses. Ten healthy young adults with class I normal occlusion consented to participate in the study and twenty patients were restored with a total 20 single-implant crowns in the left maxillary and mandibular second molars for 10 single-implant crowns, respectively. Test area were divided by 4 groups. UM describes the contact between the upper natural left first molar and natural second molar; LM the contact between the lower natural left first molar and natural second molar; IUM the contact between the upper natural left first molar and implant second molar and ILM the contact between the lower natural left first molar and implant second molar. The TPTC was measured at rest state in each area. The mean TPTC of the UM, LM, IUM and ILM was 1.48(${\pm}0.44$) N, 1.78(${\pm}0.40$) N, 1.14(${\pm}0.37$) N and 1.30(${\pm}0.32$) N respectively. These results indicate that the TPTC was less between natural tooth and implant prosthesis than between natural teeth.

Morphological Analysis of the Sinus Lateral Wall Using Cone-Beam Computed Tomography (콘빔형 전산화단층영상을 이용한 상악동 측벽의 형태학적 분석)

  • An, Seo-Young;Kim, Yong-Gun
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.28 no.4
    • /
    • pp.349-357
    • /
    • 2012
  • The purpose of this study was to measure the thickness of the sinus lateral wall using cone-beam computed tomography (CBCT), and to find the most suitable vertical position for lateral window opening prior to sinus elevation. Fifty three patients requiring sinus elevation had CBCT scans acquired by CB MercuRay (Hitachi, Medico, Tokyo, Japan) from July, 2010 to June, 2012. The thickness of the sinus lateral wall was measured according to its vertical position against the sinus inferior border (SIB), and its mean was calculated through two repeated measurements. The thickness of the sinus lateral wall was more than 2 mm at 2 mm above the sinus inferior border (SIB+2), however, it was less than 2 mm at 3 mm above the sinus inferior border (SIB+3). In conclusion, it is recommended that the inferior border of lateral wall window be made 3 mm above the sinus inferior border during sinus elevation using the lateral approach considering the thickness of the sinus lateral wall.

Synergic Effects of Mixed Formula Consisted of Polycan and Calcium-gluconate on the Experimental Periodontitis and Alveolar Bone Loss in Rats

  • Lee, Won-Ho;Kim, Kyung Hu;Kang, Su Jin;Lee, Young Joon;Ku, Sae Kwang
    • Journal of Society of Preventive Korean Medicine
    • /
    • v.18 no.1
    • /
    • pp.125-138
    • /
    • 2014
  • Objective : Polycan, exopolymers purified from Aureobasidium pullulans SM-2001 and calcium gluconate have been showed favorable inhibitory effects on the periodontitis and related alveolar bone losses through antioxidant and anti-inflammatory activities, respectively. In the present study, we intended to observe the possible synergic effects of mixed formula consisted of Polycan and calcium gluconate on ligation-induced experimental periodontitis and related alveolar bone losses in rats, and to select the fittest compositions for further developing as effective agents to ameliorate periodontal diseases. Method : Experiments were conducted as two separated two tests - first is synergic effects of Polycan and calcium gluconate 1:1, 1:9 and 9:1 mixtures, and second is 1:99, 2:98, 4:96, 8:92 and 1:9 mixtures. Experimental periodontal diseases were induced by ligature placed around the cervix of upper left incisior teeth of rats. One day after ligation placements, 200mg/kg of each single or mixed formulas of Polycan or/and calcium gluconate were orally administered for 10 days. The changes on the alveolar bone loss index and maxillary bone mineral density (BMD) were observed for detecting alveolar bone losses, and for anti-inflammatory effects, myeloperoxidase (MPO) activities and proinflammatory cytokine (tumor necrosis factor; TNF-${\alpha}$) contents were also evaluated in gingival tissues around ligature placed incisior teeth. The results of mixtures were compared with those of singe Polycan and calcium gluconate treated rat. Results : Each single or mixed formulas of Polycan or/and calcium gluconate favorably and significantly inhibited the inflammatory changes. The inhibitory effects of mixed formula consisted of Polycan and calcium gluconate 1:9 showed against periodontitis and related alveolar bone losses as compared with those of each Polycan and calcium gluconate single formula (p<0.05). In second experiment, Polycan and calcium gluconate 2:98, 4:96, 8:92 and 1:9 mixed formulas also showed significant increased anti-inflammatory and inhibitory effects against alveolar bone losses as compared with those of each single formula. Among them, Polycan and calcium gluconate 2:98 showed the highest efficacy against to ligation-induced experimental periodontitis and related alveolar bone losses. Conclusion : The results obtained in this study suggest that appropriated mixtures of Polycan and calcium gluconate showed synergic inhibitory effects against ligation-induced experimental periodontitis and related alveolar bone losses in rats. Moreover, Polycan and calcium gluconate 2:98 showed the highest efficacies in this experiment, suggesting the fittest composition for further developing as effective agents to ameliorate periodontal diseases.

A STUDY ON THE MANDIBULAR MOMENTS ACCORDING TO ANTERO-POSTERIOR PLACEMENT OF PIVOT ON LOWER NATURAL DENTITION (자연치열에 설치한 pivot의 전후방 일치변화에 따른 하악의 moment에 관한 연구)

  • Lee Hyun-Shick;Park Nam-Soo;Choi Dae-Gyun
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.31 no.3
    • /
    • pp.394-410
    • /
    • 1993
  • This study was accomplished for appreciation of the mandibular moments according to antero- posterior movement of pivot placed on the lower natural dentition. For this study, 20 subjects(male, $21\sim30$ yrs., average age 24) in the category of normal occlusion were selected, and the intraoral Vitallium clutches were cast and fabricated for each subjects. A 2-dimension PSD(Position Sensitive Detector, Hamamatsu Photonics Co., Japan) was attached to maxillary clutch in a mode of three dimensional control and LED (Light Emit Diode, Hamamatsu Photonics Co., Japan) was set up on mandibular clutch. Both clutches were set into oral cavity of each subjects and adjusted. Then the subjects were allowed to intercuspated with maximal bite force while the pivoting ball in the mid-line moving from anterior toward posterior position. The displacement scales were recorded by CCD camera(Sony, CCD-TR-705) and VCR, The conclusions were as follows : 1. When the subject was allowed to bite the metal pivoting ball in the midline of lower dentition with maximal bite force voluntarily while moving from lower central incisor to canine, 1st premolar, End premolar, 1st molar and 2nd molar. The lever actions on the pivot were revealed in all subjects. The equilibrium of moment were revealed on the pivots of 1st premolar(14 subjects), End premolar(4 subjects), and canine(2 subjects) areas. 2. The changes of loading on the TMJ according to antero-posterior positional changes of metal pivoting ball were able to recognize as follow. Compression on the TMJ was increased when the pivot moves anteriorly from the equilibrium point, and tension on the TMJ was increased when posteriorly. 3. 13 subjects were recognized their habitual chewing sides(Rights, Left8), and 7 subjects were not. During maximal biting, mandible was displaced toward their habitual chewing sides on the metal pivoting ball in the frontal plane. 4. In cephalometric analysis, the average genial angle of 20 subjects was $116.75^{\circ}$ and the average mandibular body length was 79.77mm. The equilibrium points of mandibular moment were positioned more posteriorly in the subjects having larger Genial angle than in the smaller(p<0.05). Relationships among the angle between FH plane and occlusal plane, the angle between occlusal plane and mandibular plane , and mandibular body length were not significant(p>0.05).

  • PDF

THREE DIMENSIONAL PHOTOELASTIC ANALYSIS OF STRESS OF EDENTULOUS MANDIBULE ACCORDING TO VARIOUS RIDGE SHAPES AND ARTIFICIAL TEETH SIZES (잔존치조제 형태 및 총의치 인공치 크기가 무치하악 응력발생에 미치는 영향에 관한 3차원적 광탄성응력분석)

  • Choi Chang-Deog;Yoo Kwong-Hee
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.30 no.3
    • /
    • pp.457-478
    • /
    • 1992
  • Electrical resistance strain gauges, brittle-coatings, Moir'e fringe analysis, photoelasticity methods, etc, have been employed in the study of stress analysis and three-dimensional photoelasticity method used in this experiment. The author fabricated a total of 24 samples of maxillary and mandibular edentulous ridges with normal and sharp shapes using epoxy resin, one of the photoelastic materials. In addition, complete denture made from artificial resin teeth in other twoo sizes, large and medium size, were affixed to the specimens and attached to an articulator. The following results were attained by cutting 9 slice specimens into 6mm thick portions, in accordance with the three dimensional photoelastic stress freezing method, to analyze stress distribution status under specific static loading in the central, lateral and protrusive occlusions of the shape of edentulous ridge. 1. In the case of central occlusion, when complete resin artificial teeth in large and medium sizes were used on normal and sharp alveolar ridges, high stress distribution was broadly shown in the labio-buccal sides, and low and concentrated in the lingual sides, in all cases. Generally, the highest stresses were shown at the top of the alveolus, or at 2mm below the top of the alveolus, particularly in the specimen 2, 3, and stresses were more or less the same in the symmetrical right and left sides. 2. In the case of lateral occlusion, when the same load was applied, high stresses were shown broadly at the working sides in both the labio-buccal and lingual sides, and low and concentrated at the balanced sides. The highest stresses were shown in the top of the alveolus on the working sides in specimen 2 portion, and the lowest stresses at the balanced sides in specimen 6, slightly higher stresses were shown at retromolar parts in the balanced sides. 3. In the case of protrusive occlusion, high stresses were broadly shown at the labio-buccal sides, and slightly higher stresses at the top 2, 4, and 6mm parts of the alveolus with concentration. The highest stresses were shown in specimen No. 5 and the lowes stresses in specimen 1, 9 and stresses were more of less the same at the symmetrical right and left sides.

  • PDF

A STUDY OF THE INFLUENCE ON PHONATION WHEN MAXILLARY ANTERIOR TEETH ARE MISSING (상악 전치부 결손이 발음에 미치는 영향에 관한 연구)

  • Roh Chang-Sup;Choi Dae-Gyun;Woo Yi-Hyung;Choi Boo-Byung
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.30 no.3
    • /
    • pp.338-360
    • /
    • 1992
  • This study was performed to investigate the phonetic alterations with upper anterior teeth were missing. To compare the changes of the phonations, before and after insertion of the temporary prosthesis, six subjects who lost their upper anterior teeth were selected (2-male, 4-female). Tested sounds (/ga(가), na(나), da(다), ra(라), sa(사), ja(자), cha(차), ta(타), pa(파), ha(하), gi(기), ni(니), di(디), ri(리), si(시), jl(지), chi(치), ti(티), pi(피), hi(히), seu(스), se(세), so(소), su(수)/were programmed into an IBM AT with and without temporary prosthesis. These experiments were analyzed by formants, consonants durations, and energy level changes with an LSI speech work station program. During the pronunciation of the tested sounds (with and without temporary prosthesis), mandibular movements were recorded to a Mandibular Kinesiogram and analyzed . The findings led to the following conclusions: 1. Objective differences could not be found. However, in every informant, subjective improvement could be noticed. 2. There were no persistant correlations of the formant's changes. And in every informant, phonetic changes were variable. 3. There were various changes of the consonant durations in every informant. By and large, those of /si(시), jl(지), chi(치), Pi(피), hi(히)/ were longer than other tested sounds. After insertion of the prosthesis, durations were shorter. Consonants with /i(ㅣ)/ were longer than with /a(ㅏ)/, with or without prosthesis. 4. With and without temporary prosthesis, mandibular movements were various in the frontal view. Mandibular movements showed lateral deviations, and mandibular positions with /si(시), ji(지), ti(티), seu(스), hi(히)/ were nearer to the mandibular rest position. 5. The kinds of temporary prosthesis and conditions of the missing teeth influenced every informant variously, so there were no correlation between informants. 6. Energy levels increased in all tested sounds with a fixed temporary prosthesis. And, there were no differences between before and after insertion of a removable temporary prosthesis. However, sibilant sounds, and consonants with /i(ㅣ)/ showed a little increased energy level.

  • PDF

The effect of MTAD as a final root canal irrigants on the coronal bacterial leakage of obturated root canals (최종 근관세척제로서의 MTAD 근관세척제가 치관부 세균미세누출에 미치는 영향)

  • Kim, Tae-Woo;Chang, Seok-Woo;Park, Dong-Sung
    • Restorative Dentistry and Endodontics
    • /
    • v.33 no.4
    • /
    • pp.397-404
    • /
    • 2008
  • The purpose of this study was to evaluate the effects of MTAD, EDTA and sodium hypochlorite(NaOCl) as final irrigants on coronal leakage resistance to Enterococcus faecalis. Forty extracted human maxillary molars were used in this experiment. The teeth were randomly divided into positive control group (Group 1; n = 5), negative control group (Group 2; n = 5) and three experimental groups (n = 30). In Group 3 (n = 10), the root canals were irrigated with sodium hypochlorite. In Group 4 (n = 10) and 5 (n = 10), the root canals were irrigated with sodium hypochlorite and rinsed with EDTA and MTAD, respectively. The teeth in each group were cleaned and shaped to #40 profile with .04 taper, and obturated with gutta-percha and AH-26 root canal sealer. The coronal portion of each tooth was placed in contact with inoculum of Enterococcus faecalis in Brain Heart Infusion (BHI) culture media. Each root tip was placed in a vial containing sterile culture media. The vials were placed in anaerobic chamber and observed everyday for turbidity for 180 days. Statistical analysis was performed using Fisher's Exact Test. After 180 days, Group 3, 4, and 5 showed 7, 4 and 5 leaking samples respectively. The differences in leakage resistance were not statistically significant among Group 3, 4 and 5.