• Title/Summary/Keyword: matrix correction

Search Result 179, Processing Time 0.027 seconds

Single Phase Utility Frequency AC-High Frequency AC Matrix Converter Using One-Chip Reverse Blocking IGBTs based Bidirectional Switches

  • Hisayuki, Sugimura;Kwon, Soon-Kurl;Lee, Hyun-Woo;Mutsuo, Nakaoka
    • Proceedings of the KIEE Conference
    • /
    • 2006.10d
    • /
    • pp.125-128
    • /
    • 2006
  • This paper presents a novel type soft switching PWM power frequency AC-AC converter using bidirectional active switches or single phase utility frequency AC-high frequency AC matrix converter. This converter can directly convert utility frequency AC (UFAC, 50Hz/60Hz) power to high frequency AC (HFAC) power ranging more than 20kHz up to 100kHz. A novel soft switching PWM prototype of high frequency multi-resonant PWM controlled UFAC-HFAC matrix converter using antiparallel one-chip reverse blocking IGBTs manufactured by IXYS corp. is based on the soft switching resonance with asymmetrical duty cycle PWM strategy. This single phase UFAC-HFAC matrix converter has some remarkable features as electrolytic capacitor DC busline linkless topology, unity power factor correction and sine-wave line current shaping, simple configuration with minimum circuit components, high efficiency and downsizing. This series load resonant UFAC-HFAC matrix converter, incorporating bidirectional active power switches is developed and implemented for high efficiency consumer induction heated food cooking appliances in home uses and business-uses. Its operating performances as soft switching operating ranges and high frequency effective power regulation characteristics are illustrated and discussed on the basis of simulation and experimental results.

  • PDF

Compensation for Liquid Crystal

  • Jea-Claude, Lehureau;Laure, Lee Mane Si
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2003.07a
    • /
    • pp.1104-1107
    • /
    • 2003
  • Normally white TN-LCD is the preferred solution in active matrix display thanks to easy production, fast response and good white balance. However, it is has poor viewing angle properties and correction films are difficult to design. We present the mathematics of designing a compensating film and discuss various technological solutions for making

  • PDF

Color Correction Method of Non-standard Display Using Standard Color Space (표준 색공간을 이용한 비표준 디스플레이의 색 보정 방법)

  • Kim, Eun-Su
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.16 no.3
    • /
    • pp.2151-2157
    • /
    • 2015
  • A standard default color space, sRGB, provides compatibility for the transmission of color within the Internet color operating systems and device drivers. However, a display monitor we use generally have non-standard primaries and gamma characteristic different from those specified by sRGB. In this paper, correction methods of chromatic error for a non-standard display monitor are proposed. Experimental results show that the proposed method using the correction matrix reduced chromatic errors at in compared with the non-corrected image's on a non-standard display.

The Effective Error Correction Method of a Camera in Monitor-based Augmented Reality Systems (모니터 기반 Augmented Reality 시스템에서 카메라 오차의 효율적인 보정 방법)

  • Kim, Juwan;Kim, Haedong;Jang, Byungtae;Kim, Donghyun
    • Journal of the Korea Computer Graphics Society
    • /
    • v.3 no.2
    • /
    • pp.35-43
    • /
    • 1997
  • In monitor-based AR(Augmented Reality) systems, it is required to know the position and direction of a camera in order to combine real images from a camera with virtual images exactly_ Because a tracker is parted from a camera, however, there is a registration error caused by the inconsistency of a tracker with a camera. In this paper, we describe the error correction method using genetic algorithm. This method looks for the position and direction of a camera using genetic algorithm and solves the error correction matrix of it. And then it is registered of the real images and the revised virtual image. It has an effect on the error correction caused by the misalignment of a tracker with a camera in complex AR systems.

  • PDF

The Study of Fast X-ray Fluorescence Analysis Using a SSQ Program (SSQ 프로그램을 이용한 빠른 X-선형광분석법 고찰)

  • Park, Yong Joon
    • Analytical Science and Technology
    • /
    • v.11 no.2
    • /
    • pp.112-119
    • /
    • 1998
  • A Siemens SemiQuant (SSQ) 3000 program, a precalibrated 'standardless' analytical program handling up to 90 elements, was evaluated for the fast analysis of various types of reference materials using a wavelength dispersive X-ray spectrometer. Various types of standard reference materials such as metal discs, metal chips, and geological materials in powder form were analysed and it took 23 minutes of measuring time for 75 elements. Measurements of geological reference materials using different sampling methods were carried out and their data were interactively evaluated. The analysis of materials of a known matrix concentration such as stainless steels provided higher precision value compared to totally unknown samples. The analyses of materials prepared as pressed pellets or fused glass beads provided higher precision values compared to the measurement of loose powders with a foil on the sample surface and helium operation, though their sampling procedures were more complicate and took more time. Since very light elements such as boron, carbon, and oxygen have a strong influence on the matrix effects and also on the calculation of effective matrix corrections, the rhodium Compton check was applied to verify the reliability of the defined light element concentrations of light matrix materials and the defined major sample compounds. Failure of defining correct matrix resulted in an unoptimized matrix correction and therefore in the wrong calculation of the element concentration.

  • PDF

Efficient Use of Unused Spare Columns for Reducing Memory Miscorrections

  • Jung, Ji-Hun;Ishaq, Umair;Song, Jae-Hoon;Park, Sung-Ju
    • JSTS:Journal of Semiconductor Technology and Science
    • /
    • v.12 no.3
    • /
    • pp.331-340
    • /
    • 2012
  • In the deep sub-micron ICs, growing amounts of on-die memory and scaling effects make embedded memories increasingly vulnerable to reliability and yield problems. Spare columns are often included in memories to repair defective cells or bit lines during production test. In many cases, the repair process will not use all spare columns. Schemes have been proposed to exploit these unused spare columns to store additional check bits which can be used to reduce the miscorrection probability for triple errors in single error correction-double error detection (SEC-DED). These additional check bits increase the dimensions of the parity check matrix (H-matrix) requiring extra area overhead. A method is proposed in this paper to efficiently fill the extra rows of the H-matrix on the basis of similarity of logic between the other rows. Optimization of the whole H-matrix is accomplished through logic sharing within a feasible operating time resulting in reduced area overhead. A detailed implementation using fuse technology is also proposed in this paper.

Correction of Recurrent Ingrowing Toenail Using Partial Matricectomy and Paronychial Advancement Flap (부분기질절제술과 발톱주위전진피판을 이용한 재발성 내증식발톱의 교정)

  • Kim, Eui Sik;Kim, Sung Nam;Noh, Bok Kyun;Hwang, Jae Ha;Kim, Kwang Seog;Lee, Sam Yong
    • Archives of Plastic Surgery
    • /
    • v.33 no.3
    • /
    • pp.347-352
    • /
    • 2006
  • Ingrowing toenail has been treated conventionally by various surgical treatment modlities. However, none of these procedures are perfect to achieve esthetic results with low cost, recurrence, and complication rates. Although mild cases can be treated conservatively, in severe recurrent cases, surgical treatment is preferred. The purpose of this study is to evaluate the effectiveness and safety of using partial matricectomy and paronychial advancement flap for correction of recurrent ingrowing toenail. Eight patients suffering from recurrent ingrowing toenail were operated using partial matricectomy and paronychial advancement flap in our department from August 2004 to August 2005. The number of recurrent episodes ranged from 2 to 5. With digital nerve block, the excision area was marked on nailplate and inflammed lateral nail fold. The horizontally designed paronychial flap considering defect size was effective for wide exposure of the neighboring germinal matrix, which is later to be completely excised or cauterized because remnant germinal matrix made postoperative spicule formation. The nailplate on the affected side was removed about 3-5 mm width longitudinally, being cautious not to damage the proximal dorsal nail fold. The same width of the sterile matrix including germinal matrix was excised longitudinally with inflammed granulation tissue and partial lateral nail fold on the affected side. The subcutaneously elevated paronychial flap was advanced to cover the defect and was anatomically sutured with 5-0 nylon sutures. We evaluated our procedure's effectiveness by examining some factors such as cosmetic results, recurrence, spicule formation, postoperative pain and duration of return to normal activities. In eight patients, no complication was observed such as recurrence, severe pain and spicule formation except for 1 case of infection. Postoperative discomfort was minimal. Average duration of return to normal activities was 12 days. Cosmetically the results were acceptable in all patients. The partial matricectomy and paronychial advancement flap for correction of recurrent ingrowing toenail were found to be technically simple, efficient procedure with a relative low recurrence rate and better cosmetic results.

Numerical Dispersion and Its Control for 1-D Finite Element Simulation of Stress Wave Propagation (응력파 전파 수치모의를 위한 일차원 유한요소모형의 분산 특성 및 제어)

  • 이종세;유한규;윤성범
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.17 no.1
    • /
    • pp.75-82
    • /
    • 2004
  • With an aim at eliminating the numerical dispersion error arising from the numerical simulation of stress wave propagation, numerical dispersion characteristics of the wave equation based one-dimensional finite element model are analyzed and some dispersion control scheme are proposed in this paper The dispersion analyses are carried out for two types of mass matrix, namely the consistent and the lumped mass matrices. Based on the finding of the analyses, dispersion correction techniques are developed for both the implicit and explicit schemes. For the implicit scheme, either the weighting factor for the spatial derivatives of each time level or the lumping coefficient for mass matrix is adjusted to minimize the numerical dispersion. In the case of the explicit scheme an artificial dispersion term is introduced in the governing equation. The validity of the dispersion correction techniques proposed in this study is demonstrated by comparing the numerical solutions obtained using the Present techniques with the analytical ones.

Cryptotia recurrence lowering technique with additional acellular dermal matrix graft

  • Lee, Dongeun;Kim, Young Seok;Roh, Tai Suk;Yun, In Sik
    • Archives of Craniofacial Surgery
    • /
    • v.20 no.3
    • /
    • pp.170-175
    • /
    • 2019
  • Background: Cryptotia is a congenital anomaly in which the upper part of the retroauricular sulcus is absent and buried underneath the temporal skin. Various surgical techniques have been reported for the correction of cryptotia following Kubo's V-Y plasty in 1933. Conventional methods using a local skin flap, skin grafting, tissue expansion, Z-plasty, and any of these combined approaches can result in skin deficiency of the upper auricle. The aim of this study was to develop a new method that improves cosmetic results and has fewer complications. Methods: This study involved four patients in whom five cryptotia deformities were corrected using V-Y plasty and Z-plasty. After elevation of the flap, acellular dermal matrix (ADM; MegaDerm) that was over 5 mm in thickness was applied to the cephalo-auricular angle and positioned to enhance the projection of the ear. Lastly, the flap was transposed to complete the repair. Results: Between January 2014 and February 2018, cryptotia correction with ADM graft was performed in four patients. None of the patients developed a recurrence of cryptotia, and there were no postoperative complications such as wound infection, seroma formation, and dehiscence. In addition, the procedures resulted in a favorable cosmetic appearance. Conclusion: Based on these findings, i.e., no recurrence and a favorable cosmetic result, when using an ADM graft, it is suggested that this technique could be an alternative method of cryptotia correction. It could also lessen donor-site morbidity when compared to autologous cartilage grafting and be more cost-effective than using cartilage from a cadaver.

The Simultaneous Determination of Chemical Ingredients in Silica Minerals by X-ray Fluorescence Spectrometry using Matrix Correction Method (매트릭스 보정법을 이용한 규산질 광물 중 화학성분의 X-선 형광분광법 분석)

  • Kim, Yeong Man;Choe, Beom Seok;Lee, Gyeong Mi;Kim, Seon Tae;Lee, Jong Uk
    • Journal of the Korean Chemical Society
    • /
    • v.34 no.1
    • /
    • pp.63-68
    • /
    • 1990
  • The chemical ingredients such as $SiO_2,\;Al_2O_3,\;MgO,\;Fe_2O_3,\;CaO$ and $TiO_2$in silica minerals were determined by X-ray fluorescence spectrometry using a matrix correction method. The synthesized standards mixed with reagent grade oxides and the sample were diluted by fusing with 16 times $Li_2B_4O_7$. The matrix effects correlated among the ingredients were corrected by the empirical coefficient method based on the Lucas-Tooth and Pyne model. The analytical results showed relatively good agreement between the different sets of coefficients but were improved with increasing the number of standard. The accuracy of this method was also examined with the standard reference material of NIST.

  • PDF