• Title/Summary/Keyword: matrix correction

Search Result 179, Processing Time 0.031 seconds

Importance Performance Analysis (IPA) on the Management Improving of Integrative Medical Hospital and Unmet Medical Care Services (통합의료병원의 환자 미충족 의료서비스 및 경영개선을 위한 IPA)

  • Cheong, Moon-Joo;Jeon, Byeong-Hyeon;Noh, Se-Eung
    • Journal of The Korean Society of Integrative Medicine
    • /
    • v.9 no.1
    • /
    • pp.69-90
    • /
    • 2021
  • Purpose : This study explores unmet medical services within a region for patients admitted to a single medical institution in one region and was to analyze the importance and satisfaction of hospital selection attributes. Through this, we tried to solve the unmet medical needs of patients and provide useful basic data in terms of hospital management in the region. Methods : It were collected to a total of 250 questionnaires for patients admitted to the regional integrative medical hospital. However, 232 samples were used for the final analysis, excluding 18 copies not reported in good faith. For the analysis, first, demographic frequency analysis of inpatients and inpatients was performed, and second, characteristics of patients, including frequent disease receiving treatment, were analyzed. Next, descriptive statistics analysis was conducted on unmet medical service intentions. In terms of hospital selection attribute, the items of continuity maintenance (I quadrant), priority visibility (II quadrant), low priority (III quadrant), and excessive effort (IV quadrant) were derived using the IPA (importance-performance analysis) matrix technique. Results : The derived results were classified by item and area. In the priority administration area, it was the reputation and recognition of medical institutions and the service area of medical institutions. In the case of items, there were 6 items including the importance of surgery and medical expenses, and diet at hospitalization. 1) Conclusion : Thus a result of this study, resources are efficiently allocated to priority correction areas with high importance but low satisfaction and circulatory medical treatment is performed in the departments required by patients who use medical care and, various methods, such as preparing a policy to support medical expenses, should be sought.

Improvement and Validation of Convective Rainfall Rate Retrieved from Visible and Infrared Image Bands of the COMS Satellite (COMS 위성의 가시 및 적외 영상 채널로부터 복원된 대류운의 강우강도 향상과 검증)

  • Moon, Yun Seob;Lee, Kangyeol
    • Journal of the Korean earth science society
    • /
    • v.37 no.7
    • /
    • pp.420-433
    • /
    • 2016
  • The purpose of this study is to improve the calibration matrixes of 2-D and 3-D convective rainfall rates (CRR) using the brightness temperature of the infrared $10.8{\mu}m$ channel (IR), the difference of brightness temperatures between infrared $10.8{\mu}m$ and vapor $6.7{\mu}m$ channels (IR-WV), and the normalized reflectance of the visible channel (VIS) from the COMS satellite and rainfall rate from the weather radar for the period of 75 rainy days from April 22, 2011 to October 22, 2011 in Korea. Especially, the rainfall rate data of the weather radar are used to validate the new 2-D and 3-DCRR calibration matrixes suitable for the Korean peninsula for the period of 24 rainy days in 2011. The 2D and 3D calibration matrixes provide the basic and maximum CRR values ($mm\;h^{-1}$) by multiplying the rain probability matrix, which is calculated by using the number of rainy and no-rainy pixels with associated 2-D (IR, IR-WV) and 3-D (IR, IR-WV, VIS) matrixes, by the mean and maximum rainfall rate matrixes, respectively, which is calculated by dividing the accumulated rainfall rate by the number of rainy pixels and by the product of the maximum rain rate for the calibration period by the number of rain occurrences. Finally, new 2-D and 3-D CRR calibration matrixes are obtained experimentally from the regression analysis of both basic and maximum rainfall rate matrixes. As a result, an area of rainfall rate more than 10 mm/h is magnified in the new ones as well as CRR is shown in lower class ranges in matrixes between IR brightness temperature and IR-WV brightness temperature difference than the existing ones. Accuracy and categorical statistics are computed for the data of CRR events occurred during the given period. The mean error (ME), mean absolute error (MAE), and root mean squire error (RMSE) in new 2-D and 3-D CRR calibrations led to smaller than in the existing ones, where false alarm ratio had decreased, probability of detection had increased a bit, and critical success index scores had improved. To take into account the strong rainfall rate in the weather events such as thunderstorms and typhoon, a moisture correction factor is corrected. This factor is defined as the product of the total precipitable waterby the relative humidity (PW RH), a mean value between surface and 500 hPa level, obtained from a numerical model or the COMS retrieval data. In this study, when the IR cloud top brightness temperature is lower than 210 K and the relative humidity is greater than 40%, the moisture correction factor is empirically scaled from 1.0 to 2.0 basing on PW RH values. Consequently, in applying to this factor in new 2D and 2D CRR calibrations, the ME, MAE, and RMSE are smaller than the new ones.

A Study of Quality Control of Nuclear Medicine Counting System and Gamma Camera (핵의학 계측기기 및 감마카메라의 정도관리 연구)

  • 손혜경;김희중;정해조;정하규;이종두;유형식
    • Progress in Medical Physics
    • /
    • v.12 no.2
    • /
    • pp.103-112
    • /
    • 2001
  • Purpose: The purpose of this study was to investigate the current status of performing nuclear medicine quality control in korea and to test selected protocols of quality control of nuclear medicine counting system and gamma camera. Materials and Methods: Fifty three hospitals were included to investigate the current status of nuclear medicine quality control in korea. The precision of dose calibrator and thyroid uptake system was measured with Tc-99m 35.52 MBq for 2 minuets and Tc-99m 5.14 MBq for 10 sec every one minute, respectively. The sensitivity of CeraSPECT$^{TM}$ with low energy high resolution parallel hole collimator was measured using two cylindrical phantoms with 15 cm in diameter and 12 cm and 30 cm in heights containing Tc-99m. The correction factor for sensitivity of CeraSPECT$^{TM}$ was calculated using phantom data. The system planar sensitivity, uniformity, count rate and spatial resolution were measured for Varicam gamma camera with low energy high resolution parallel hole collimator using 140 keV centered 20% energy window, 256$\times$256 or 512$\times$512 matrix sizes. Results: The quality control of dose calibrator and well counter were showed poor performance status. On the other hand, The quality control of gamma camera and other systems were showed relatively good performance status. The results of precision of dose calibrator and thyroid uptake system was $\pm$1.4%(<$\pm$5%) and chi^2=29.7(>16.92), respectively. It showed that the sensitivity of CeraSPECT$^{TM}$ was higher in center slices compared with the edge slices. After correction of nonuniform sensitivities for patient data, it showed better results compare with prior to correction. System planar sensitivity of Varicam gamma camera was 4.39 CPM/MBq. The observed count rate at 20% loss was 102,407 counts/sec (head 1), 113,427 counts/sec (head 2), when input count rate was 81,926 counts/sec (head 1), 90,741 counts/sec (head 2). The spatial resolution without scatter medium were 8.16 mm of FWHM and 14.85 mm of FWTM. The spatial resolution with scatter medium were 8.87 mm of FWHM and 18.87 mm of FWTM. Conclusion: It is necessary to understand the importance of quality control and to perform quality control of nuclear medicine devices.vices.

  • PDF

The Usefulness of F-18-FDG PET and The Effect of Scan Protocol in Diagnosis of Intraocular Tumors (안구 내 종양의 진단에 있어서 F-18-FDG PET의 유용성과 검사 방법의 영향)

  • Lee, Jae-Soung;Yang, Won-Il;Kim, Byoung-Il;Choi, Chang-Woon;Lim, Sang-Moo;Lee, Tae-Won;Sin, Min-Kyeung;Hong, Soung-Woon
    • The Korean Journal of Nuclear Medicine
    • /
    • v.33 no.5
    • /
    • pp.439-451
    • /
    • 1999
  • Purpose : It is important to differentiate malignant from benign lesions of intraocular masses in choosing therapeutic plan. Biopsy of intraocular tumor is not recommended due to the risk of visual damage. We evaluated the usefulness of F-18-FDG PET imaging in diagnosing intraocular neoplasms. Materials and Methods: F-18-FDG PET scan was performed in 13 patients (15 lesions) suspected to have malignant intraocular tumors. There were 3 benign lesions (retinal detachment, choroidal effusion and hemorrhage) and 10 patients with 12 malignant lesions (3 melanomas, 7 retinoblastomas and 2 metastatic cancers). Regional eye images ($256{\times}256$ and $128{\times}128$ matrices) were obtained with or without attenuation correction. Whole body scan was also performed in eight patients (3 benign and 6 malignant lesions). Results: All malignant lesions were visualized while all benign lesions were not visualized. The mean peak standardized uptake value (SUV) of malignant lesions was $2.64{\pm}0.57g/ml$. There was no correlations between peak SUV and tumor volume. Two large malignant lesions ($> 1000 mm^3$) showed hot uptake on whole body scan. But two medium-sized lesions ($100-1000mm^3$) looked faint and two small ($<100mm^3$) lesions were not visualized. The images reconstructed with $256{\times}256$ matrix showed lesions more clearly than those with $128{\times}128$ matrix Conclusion: F-18-FDG PET scan is highly sensitivity in detecting malignant intraocular tumor For the evaluation of small-sized intraocular lesions, whole body scan is not appropriate because of low sensitivity. A regional scan with sufficient acquisition time is recommended for that purpose. Image reconstruction in matrix size of $256{\times}256$ produced clearer images than the ones in $128{\times}128$, but it does not affect the diagnostic sensitivity.

  • PDF

A digital Audio Watermarking Algorithm using 2D Barcode (2차원 바코드를 이용한 오디오 워터마킹 알고리즘)

  • Bae, Kyoung-Yul
    • Journal of Intelligence and Information Systems
    • /
    • v.17 no.2
    • /
    • pp.97-107
    • /
    • 2011
  • Nowadays there are a lot of issues about copyright infringement in the Internet world because the digital content on the network can be copied and delivered easily. Indeed the copied version has same quality with the original one. So, copyright owners and content provider want a powerful solution to protect their content. The popular one of the solutions was DRM (digital rights management) that is based on encryption technology and rights control. However, DRM-free service was launched after Steve Jobs who is CEO of Apple proposed a new music service paradigm without DRM, and the DRM is disappeared at the online music market. Even though the online music service decided to not equip the DRM solution, copyright owners and content providers are still searching a solution to protect their content. A solution to replace the DRM technology is digital audio watermarking technology which can embed copyright information into the music. In this paper, the author proposed a new audio watermarking algorithm with two approaches. First, the watermark information is generated by two dimensional barcode which has error correction code. So, the information can be recovered by itself if the errors fall into the range of the error tolerance. The other one is to use chirp sequence of CDMA (code division multiple access). These make the algorithm robust to the several malicious attacks. There are many 2D barcodes. Especially, QR code which is one of the matrix barcodes can express the information and the expression is freer than that of the other matrix barcodes. QR code has the square patterns with double at the three corners and these indicate the boundary of the symbol. This feature of the QR code is proper to express the watermark information. That is, because the QR code is 2D barcodes, nonlinear code and matrix code, it can be modulated to the spread spectrum and can be used for the watermarking algorithm. The proposed algorithm assigns the different spread spectrum sequences to the individual users respectively. In the case that the assigned code sequences are orthogonal, we can identify the watermark information of the individual user from an audio content. The algorithm used the Walsh code as an orthogonal code. The watermark information is rearranged to the 1D sequence from 2D barcode and modulated by the Walsh code. The modulated watermark information is embedded into the DCT (discrete cosine transform) domain of the original audio content. For the performance evaluation, I used 3 audio samples, "Amazing Grace", "Oh! Carol" and "Take me home country roads", The attacks for the robustness test were MP3 compression, echo attack, and sub woofer boost. The MP3 compression was performed by a tool of Cool Edit Pro 2.0. The specification of MP3 was CBR(Constant Bit Rate) 128kbps, 44,100Hz, and stereo. The echo attack had the echo with initial volume 70%, decay 75%, and delay 100msec. The sub woofer boost attack was a modification attack of low frequency part in the Fourier coefficients. The test results showed the proposed algorithm is robust to the attacks. In the MP3 attack, the strength of the watermark information is not affected, and then the watermark can be detected from all of the sample audios. In the sub woofer boost attack, the watermark was detected when the strength is 0.3. Also, in the case of echo attack, the watermark can be identified if the strength is greater and equal than 0.5.

Impact of Emission Inventory Choices on PM10 Forecast Accuracy and Contributions in the Seoul Metropolitan Area (배출량 목록에 따른 수도권 PM10 예보 정합도 및 국내외 기여도 분석)

  • Bae, Changhan;Kim, Eunhye;Kim, Byeong-Uk;Kim, Hyun Cheol;Woo, Jung-Hun;Moon, Kwang-Joo;Shin, Hye-Jung;Song, In Ho;Kim, Soontae
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.33 no.5
    • /
    • pp.497-514
    • /
    • 2017
  • This study quantitatively analyzes the effects of emission inventory choices on the simulated particulate matter (PM) concentrations and the domestic/foreign contributions in the Seoul Metropolitan Area (SMA) with an air quality forecasting system. The forecasting system is composed of Weather Research and Forecasting (WRF)-Sparse Matrix Operator Kernel Emissions (SMOKE)-Community Multi-Scale Air Quality (CMAQ). Different domestic and foreign emission inventories were selectively adopted to set up four sets of emissions inputs for air quality simulations in this study. All modeling cases showed that model performance statistics satisfied the criteria levels (correlation coefficient >0.7, fractional error <50%) suggested by previous studies. Notwithstanding the apparently good model performance of total PM concentrations by all emission cases, annual average concentrations of simulated total PM concentrations varied up to $20{\mu}g/m^3$ (160%) depending on the combination of emission inventories. In detail, the difference in simulated annual average concentrations of the primary PM coarse (PMC) was up to $25.2{\mu}g/m^3$ (6.5 times) compared with other cases. Furthermore, model performance analyses on PM species showed that the difference in the simulated primary PMC led to gross model overestimation in general, which indicates that the primary PMC emissions need to be improved. The contribution analysis using model direct outputs indicated that the domestic contributions to the annual average PM concentrations in the SMA vary from 44% to 67%. To account for the uncertainty of the simulated concentration, the contribution correction factor method proposed by Bae et al. (2017) was applied, which resulted in converged contributions(from 48% to 57%). We believe this study shows that it is necessary to improve the simulated concentrations of PM components in order to enhance the accuracy of the forecasting model. It is deemed that these improvements will provide more accurate contribution results.

Magnetic Investigation of the Yangsan Fault (양산 단층에 대한 자력탐사 연구)

  • Kwon, Byung-Doo;Lee, Ki-Won
    • Economic and Environmental Geology
    • /
    • v.24 no.4
    • /
    • pp.421-434
    • /
    • 1991
  • Ground magnetic surveys were conducted at four areas where the Yangsan fault, the most prominent lineament in the Kyeongsang basin, appears to be passed through. For data processing, IGRF correction, upward continuation and reduction-to-the-pole were performed. The automatic inversion by using a matrix computation method, which takes the depth to bottom layer of the horizontal two layer structure as the model parameter, has been attempted to delineate the subsurface structure. Upward continuation of the surface magnetic map to the same level of the aeromagnetic survey (KIER, 1989) resulted in very similiar patterns to those of aeromagnetic data. Subsurface modeling of eight profile data show that the strike and dip of the Yangsan fault in study areas are $N6^{\circ}-15^{\circ}E$, and near vertical to somewhat eastward, repectively, despite of the local lithological contrast of each study area. It seems that the magnetic effect of faulting in the study area 1, which locates in the most northern part of the survey areas, is disturbed by that of igneous intrusion. At study area 2, the possibility of volcanic or igneous intrusion, which is 200-300 meters wide along the fault plane was presented. At study area 3, unlike other study areas, distinct fracture zone of 500-700 meters in width was revealed along the surface fault line. The andesitic rocks of the study area 4 have very high susceptibilities and the fault line on surface of this area was shifted about 500 meter eastward, as compared with the inferred fault line by the previous study.

  • PDF

A LDPC Decoder for DVB-S2 Standard Supporting Multiple Code Rates (DVB-S2 기반에서 다양한 부호화 율을 지원하는 LCPC 복호기)

  • Ryu, Hye-Jin;Lee, Jong-Yeol
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.45 no.2
    • /
    • pp.118-124
    • /
    • 2008
  • For forward error correction, DVB-S2, which is the digital video broadcasting forward error coding and modulation standard for satellite television, uses a system based the concatenation of BCH with LDPC inner coding. In DVB-S2 the LDPC codes are defined for 11 different code rates, which means that a DVB-S2 LDPC decoder should support multiple code rates. Seven of the 11 code rates, 3/5, 2/3, 3/4, 4/5, 5/6, 8/9, and 9/10, are regular and the rest four code rates, 1/4, 1/3, 2/5, and 1/2, are irregular. In this paper we propose a flexible decoder for the regular LDPC codes. We combined the partially parallel decoding architecture that has the advantages in the chip size, the memory efficiency, and the processing rate with Benes network to implement a DVB-S2 LDPC decoder that can support multiple code rates with a block size of 64,800 and can configure the interconnection between the variable nodes and the check nodes according to the parity-check matrix. The proposed decoder runs correctly at the frequency of 200MHz enabling 193.2Mbps decoding throughput. The area of the proposed decoder is $16.261m^2$ and the power dissipation is 198mW at a power supply voltage of 1.5V.

An analysis of optimal design conditions of LDPC decoder for IEEE 802.11n Wireless LAN Standard (IEEE 802.11n 무선랜 표준용 LDPC 복호기의 최적 설계조건 분석)

  • Jung, Sang-Hyeok;Na, Young-Heon;Shin, Kyung-Wook
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.14 no.4
    • /
    • pp.939-947
    • /
    • 2010
  • The LDPC(Low-Density Parity-Check) code, which is one of the channel encoding methods in IEEE 802.11n wireless LAN standard, has superior error-correcting capabilities. Since the hardware complexity of LDPC decoder is high, it is very important to take into account the trade-offs between hardware complexity and decoding performance. In this paper, the effects of LLR(Log-Likelihood Ratio) approximation on the performance of MSA(Min-Sum Algorithm)-based LDPC decoder are analyzed, and some optimal design conditions are derived. The parity check matrix with block length of 1,944 bits and code rate of 1/2 in IEEE 802.11n WLAN standard is used. In the case of $BER=10^{-3}$, the $E_b/N_o$ difference between LLR bit-widths (6,4) and (7,5) is 0.62 dB, and $E_b/N_o$ difference for iteration cycles 6 and 7 is 0.3 dB. The simulation results show that optimal BER performance can be achieved by LLR bit-width of (7,5) and iteration cycle of 7.

Software development for the visualization of brain fiber tract by using 24-bit color coding in diffusion tensor image

  • Oh, Jung-Su;Song, In-Chan;Ik hwan Cho;Kim, Jong-Hyo;Chang, Kee-Hyun;Park, Kwang-Suk
    • Proceedings of the KSMRM Conference
    • /
    • 2002.11a
    • /
    • pp.133-133
    • /
    • 2002
  • Purpose: The purpose of paper is to implement software to visualize brain fiber tract using a 24-bit color coding scheme and to test its feasibility. Materials and Methods: MR imaging was performed on GE 1.5 T Signa scanner. For diffusion tensor image, we used a single shot spin-echo EPI sequence with 7 non-colinear pulsed-field gradient directions: (x, y, z):(1,1,0),(-1,1,0),(1,0,1),(-1,0,1),(0,1,1),(0,1,-1) and without diffusion gradient. B-factor was 500 sec/$\textrm{mm}^2$. Acquisition parameters are as follows: TUTE=10000ms/99ms, FOV=240mm, matrix=128${\times}$128, slice thickness/gap=6mm/0mm, total slice number=30. Subjects consisted of 10 normal young volunteers (age:21∼26 yrs, 5 men, 5 women). All DTI images were smoothed with Gaussian kernel with the FWHM of 2 pixels. Color coding schemes for visualization of directional information was as follows. HSV(Hue, Saturation, Value) color system is appropriate for assigning RGB(Red, Green, and Blue) value for every different directions because of its volumetric directional expression. Each of HSV are assigned due to (r,$\theta$,${\Phi}$) in spherical coordinate. HSV calculated by this way can be transformed into RGB color system by general HSV to RGB conversion formula. Symmetry schemes: It is natural to code the antipodal direction to be same color(antipodal symmetry). So even with no symmetry scheme, the antipodal symmetry must be included. With no symmetry scheme, we can assign every different colors for every different orientation.(H =${\Phi}$, S=2$\theta$/$\pi$, V=λw, where λw is anisotropy). But that may assign very discontinuous color even between adjacent yokels. On the other hand, Full symmetry or absolute value scheme includes symmetry for 180$^{\circ}$ rotation about xy-plane of color coordinate (rotational symmetry) and for both hemisphere (mirror symmetry). In absolute value scheme, each of RGB value can be expressed as follows. R=λw|Vx|, G=λw|Vy|, B=λw|Vz|, where (Vx, Vy, Vz) is eigenvector corresponding to the largest eigenvalue of diffusion tensor. With applying full symmetry or absolute value scheme, we can get more continuous color coding at the expense of coding same color for symmetric direction. For better visualization of fiber tract directions, Gamma and brightness correction had done. All of these implementations were done on the IDL 5.4 platform.

  • PDF