• Title/Summary/Keyword: matrix correction

Search Result 179, Processing Time 0.159 seconds

Finite element based post-buckling analysis of refined graphene oxide reinforced concrete beams with geometrical imperfection

  • Mirjavadi, Seyed Sajad;Forsat, Masoud;Yahya, Yahya Zakariya;Barati, Mohammad Reza;Jayasimha, Anirudh Narasimamurthy;Khan, Imran
    • Computers and Concrete
    • /
    • v.25 no.4
    • /
    • pp.283-291
    • /
    • 2020
  • The present paper researches post-buckling behaviors of geometrically imperfect concrete beam resting on elastic foundation reinforced with graphene oxide powders (GOPs) based on finite element method (FEM). Distribution of GOPs are considered as uniform and linearly graded through the thickness. Geometric imperfection is considered as first buckling mode shape of the beam, the GOP reinforced beam is rested in initial position. The material properties of GOP reinforced composite have been calculated via employment of Halpin-Tsai micromechanical scheme. The provided refined beam element verifies the shear deformation impacts needless of any shear correction coefficient. The post-buckling load-deflections relations have been calculated via solving the governing equations having cubic non-linearity implementing FEM. Obtained findings indicate the importance of GOP distributions, GOP weight fraction, matrix material, geometric imperfection, shear deformation and foundation parameters on nonlinear buckling behavior of GOP reinforced beam.

Comparative Analysis of the Difference in the Midgut Microbiota between the Laboratory Reared and the Field-caught Populations of Spodoptera litura

  • Pandey, Neeti;Rajagopal, Raman
    • Microbiology and Biotechnology Letters
    • /
    • v.47 no.3
    • /
    • pp.423-433
    • /
    • 2019
  • Midgut microbiota is known to play a fundamental role in the biology and physiology of the agricultural pest, Spodoptera litura. This study reports the difference in the larval midgut microbiota of field-caught and laboratory-reared populations of S. litura by performing 16S rDNA amplicon pyrosequencing. Field populations for the study were collected from castor crops, whereas laboratory-reared larvae were fed on a regular chickpea based diet. In total, 23 bacterial phylotypes were observed from both laboratory-reared and field-caught caterpillars. Fisher's exact test with Storey's FDR multiple test correction demonstrated that bacterial genus, Clostridium was significantly abundant (p < 0.05) in field-caught larvae of S. litura as compared to that in the laboratory-reared larvae. Similarly, bacterial genera, such as Bradyrhizobium, Burkholderia, and Fibrisoma were identified (p < 0.05) predominantly in the laboratory-reared population. The Bray-Curtis dissimilarity matrix depicted a value of 0.986, which exhibited the maximum deviation between the midgut microbiota of the laboratory-reared and field-caught populations. No significant yeast diversity was seen in the laboratory-reared caterpillars. However, two yeast strains, namely Candida rugosa and Cyberlindnera fabianii were identified by PCR amplification and molecular cloning of the internal transcribed space region in the field-caught caterpillars. These results emphasize the differential colonization of gut residents based on environmental factors and diet.

Evaluation of peak-fitting software for magnesium quantification through k0-instrumental neutron activation analysis

  • Dasari, Kishore B.;Cho, Hana;Jacimovic, Radojko;Park, Byung-Gun;Sun, Gwang-Min
    • Nuclear Engineering and Technology
    • /
    • v.54 no.2
    • /
    • pp.462-468
    • /
    • 2022
  • The selection and effective utilization of peak-fitting software for conventional gamma-ray spectrum analysis is significant for accurate determination of the mass fraction of elements, particularly in complex peak regions. Majority of the peak-fitting programs can derive similar peak characteristics for singlet peaks, but very few programs can deconvolute multi-peaks in a complex region. The deconvolution of multi-peaks requires special peak-fitting functions, such as left and right-skew distributions. In the this study, 843.76 keV (27Mg) peak area from the complex region (840 keV-850 keV) determined and compared using four different peak-fitting programs, namely, GammaVision, Genie2000, HyperLab, and HyperGam. The 843.76 keV peak interfered with 841.63 keV (152mEu) and 846.81 keV (56Mn). The total Mg concentration was determined through k0-instrumental neutron activation analysis by applying the isotopic interference correction factor 27Al(n,p)27Mg through the simultaneous determination of Al concentration. HyperLab and HyperGam peak-fitting programs reported consistent peak areas, and resultant concentrations agreed with the certified values of matrix-certified reference materials.

The Role of FDI in Economic Development in Vietnam + 5 Nations: Empirical Evidence between 1986-2020

  • Long Ma, LE
    • The Journal of Asian Finance, Economics and Business
    • /
    • v.10 no.2
    • /
    • pp.203-212
    • /
    • 2023
  • This research work aims to investigate the role of FDI in Economic Development by assessing its relationship with GDP per capita in Vietnam +5 from 1986-2020. Through descriptive statistical, correlation matrix analysis, and econometric models, including Vector Error Correction Model (VECM) and Feasible Generalized Least Squares (FGLS) estimation methods using Stata 15.1. The VECM estimation method results show that FDI positively impacts Economic Development in the short run while not finding a long-run relationship. In addition, it is found that a clear relationship between Exports and Economic Development in both the short run and the long run. Meanwhile, CO2 emissions and Employment Opportunities have no clear relationship with Economic Development in the short run. However, the relationship is reversed in the long run, as the empirical study in Vietnam. The results of the FGLS estimation method show that FDI, CO2 emissions, and Exports have a significant and positive impact on Economic Development in five selected Southeast Asian countries without Employment Opportunities in the long run. From these findings, the author proposes some policy implications of attaching FDI to sustainable Economic Development in Vietnam next time.

Finite Element Vibration Analysis of Laminated Composite Folded Structures With a Channel Section using a High-order Shear deformation Plate Theory (고차전단변형 판이론을 이용한 채널단면을 갖는 복합적층 절판 구조물의 유한요소 진동 해석)

  • 유용민;장석윤;이상열
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.17 no.1
    • /
    • pp.21-30
    • /
    • 2004
  • This study deals with free vibrations of laminated composite structures with a channel section using finite element method. In this paper, the mixed finite element method using Lagrangian and Hermite interpolation functions is adopted and a high-order plate theory is used to analyze laminated composite non-prismatic folded plates with a channel section more accurately for free vibration. The theory accounts for parabolic distribution of the transverse shear stress and requires no shear correction factors supposed in the first-order plate theory. An 32×32 matrix is assembled to transform the system element matrices from the local to global coordinates using a coordinate transformation matrix, in which an eighth drilling degree of freedom (DOF) per node is appended to the existing 7-DOF system. The results in this study are compared with those of available literatures for the conventional and first-order plate theory. Sample studies are carried out for various layup configurations and length-thickness ratio, and geometric shapes of plates. The significance of the high-order plate theory in analyzing complex composite structures with a channel section is enunciated in this paper.

Comparison of Collimator Choice on Image Quality of I-131 in SPECT/CT (I-131 SPECT/CT 검사의 에서 조준기 종류에 따른 영상 비교 평가)

  • Kim, Jung Yul;Kim, Joo Yeon;Nam-Koong, Hyuk;Kang, Chun Goo;Kim, Jae Sam
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.18 no.1
    • /
    • pp.33-42
    • /
    • 2014
  • Purpose: I-131 scan using High Energy (HE) collimator is generally used. While, Medium Energy (ME) collimator is not suggested to use in result of an excessive septal penetration effects, it is used to improve the sensitivities of count rate on lower dose of I-131. This research aims to evaluate I-131 SPECT/CT image quality using by HE and ME collimator and also find out the possibility of ME collimator clinical application. Materials and Methods: ME and HE collimator are substituted as Siemens symbia T16 SPECT/CT, using I-131 point source and NEMA NU-2 IQ phantom. Single Energy Window (SEW) and Triple Energy Windows (TEW) are applied for image acquisition and images with CTAC and Scatter correction application or not, applied different number of iteration and sub set are reconstructed by IR method, flash 3D. By analysis of acquired image, the comparison on sensitivities, contrast, noise and aspect ratio of two collimators are able to be evaluated. Results: ME Collimator is ahead of HE collimator in terms of sensitivity (ME collimator: 188.18 cps/MBq, HE collimator: 46.31 cps/MBq). For contrast, reconstruction image used by HE collimator with TEW, 16 subset 8 iteration applied CTAC is shown the highest contrast (TCQI=190.64). In same condition, ME collimator has lower contrast than HE collimator (TCQI=66.05). The lowest aspect ratio for ME collimator and HE collimator are 1.065 with SEW, CTAC (+) and 1.024 with TEW, CTAC (+) respectively. Conclusion: Selecting a proper collimator is important factor for image quality. This research finding tells that HE collimator, which is generally used for I-131 scan emitted high energy ${\gamma}$-ray is the most recommendable collimator for image quality. However, ME collimator is also applicable in condition of lower dose, lower sensitive if utilizing energy window, matrix size, IR parameter, CTAC and scatter correction appropriately.

  • PDF

Analysis of Selenium in Grain with ORC Collision-Removal of Br Interference using Mathematical Calibration (ORC ICPMS에서의 곡류중의 셀레늄 분석-수학적 보정을 이용한 Br의 간섭제거)

  • Cho, Heon-Hong;Pak, Yong-Nam
    • Journal of the Korean Chemical Society
    • /
    • v.55 no.3
    • /
    • pp.472-477
    • /
    • 2011
  • The concentration of selenium in grain samples was determined using isotope dilution method in ORC-ICPMS. The experimental conditions were optimized to $H_2$ mode and the flow rate was $4.0\;mL\;min^{-1}$. ORC in $H_2$ mode proved to eliminate most of polyatomic interferences except $BrH^+$ when Br is present in sample matrix. Chemical removal of Br was very difficult and the mathematical correction was successfully employed. The fraction of $BrH^+$ generated from Br at the current experimental condition was 14.1%. The signal on m/z 82 was corrected and calculated for isotope dilution. The analytical reliability of the propose method was successfully evaluated by analyzing the certified standard reference material NIST SRM 1566 and 1567. The method was applied to real samples and the results are $0.034{\pm}0.001\;{\mu}g\;g^{-1}$ for white rice, $0.059{\pm}0.002_5\;{\mu}g\;g^{-1}$ for brown rice, $0.029{\pm}0.001_4\;{\mu}g\;g^{-1}$ for black rice, and $0.034{\pm}0.002\;{\mu}g \;g^{-1}$ for barley. The detection limits ($3\sigma$) for Se was $0.012\;ng\;g^{-1}$.

Rapid and Precise Determination of Pb Isotope Ratios Using Mu1ti-Collector ICP/MS (다검출기 유도결합 플라즈마 질량분석기를 이용한 신속하고 정밀한 Pb 동위원소 분석)

  • 최만식;정창식;신형선;임태선
    • The Journal of the Petrological Society of Korea
    • /
    • v.10 no.3
    • /
    • pp.157-171
    • /
    • 2001
  • This study investigated the effects of Pb/Tl ratio, Pb concentration and concomitant matrix elements on the measurement of Pb isotope ratios using multi-collector ICP/MS (AXIOM MC model). Accuracy and reproducibility of Pb isotope ratios in NBS 981 solution were estimated for 42 data measured from March to August 2001. Pb isotopes measured in rocks, bronzes and sediments were compared to data measured by TIMS. Reproducibilities for $^{206}Pb/^{204}Pb,\; ^{207}Pb/^{204}Pb,\;and\;^{208}Pb/^{204}Pb$ ratio were about 500 ppm (2sd) and for $^{207}Pb/^{206}Pb$\;and\;^{208}Pb/^{206}Pb$ were 100~200 ppm for 200 ng of Pb in NBS 981 solution. The optimum conditions for the analysis of Pb isotope ratios with AXIOM MC for best accuracy and reproducibility were defined as follows; 1) Pb/Tl ratio is about 10 2) Pb concentration is about 100 ng/ml 3) correction for mass discrimination is performed by exponential law using 2.3887 of $^{205}Tl/^{203}Tl$ and Pb mass fractionation factor empirically obtained from $ln(^{208}Pb/^{206}Pb)-ln(^{205}Tl/^{203}Tl)$ relationship. The sample data measured with MC/ICP/MS for acid-digested and chemically separated rock samples, and acid-digested bronze samples and sediment samples coincide with those of TIMS within analytical errors. Therefore, MC/ICP/MS is a rapid analytical technique for Pb isotope ratios with the similar precision compared with TIMS.

  • PDF

A LDPC decoder supporting multiple block lengths and code rates of IEEE 802.11n (다중 블록길이와 부호율을 지원하는 IEEE 802.11n용 LDPC 복호기)

  • Na, Young-Heon;Park, Hae-Won;Shin, Kyung-Wook
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.15 no.6
    • /
    • pp.1355-1362
    • /
    • 2011
  • This paper describes a multi-mode LDPC decoder which supports three block lengths(648, 1296, 1944) and four code rates(1/2, 2/3, 3/4, 5/6) of IEEE 802.11n WLAN standard. Our LDPC decoder adopts a block-serial architecture based on min-sum algorithm and layered decoding scheme. A novel way to store check-node values and parity check matrix reduces the sizes of check-node memory and H-ROM. An efficient scheme for check-node memory addressing is used to achieve stall-free read/write operations. The designed LDPC decoder is verified by FPGA implementation, and synthesized with a $0.18-{\mu}m$ CMOS cell library. It has 219,100 gates and 45,036 bits RAM, and the estimated throughput is about 164~212 Mbps at 50 MHz@2.5v.

Correction of Missing Feature Points for 3D Modeling from 2D object images (2차원 객체 영상의 3차원 모델링을 위한 손실 특징점 보정)

  • Koh, Sung-shik
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.19 no.12
    • /
    • pp.2844-2851
    • /
    • 2015
  • How to recover from the multiple 2D images into 3D object has been widely studied in the field of computer vision. In order to improve the accuracy of the recovered 3D shape, it is more important that noise must be minimized and the number of image frames must be guaranteed. However, potential noise is implied when tracking feature points. And the number of image frames which is consisted of an observation matrix usually decrease because of tracking failure, occlusions, or low image resolution, and so on. Therefore, it is obviously essential that the number of image frames must be secured by recovering the missing feature points under noise. Thus, we propose the analytic approach which can control directly the error distance and orientation of missing feature point by the geometrical properties under noise distribution. The superiority of proposed method is demonstrated through experimental results for synthetic and real object.