• 제목/요약/키워드: material area

검색결과 4,893건 처리시간 0.035초

극저온중 고분자 Film의 부분방전 연구 (A Study on Partial Discharge of Polymer Film at Cryogenic Temperature)

  • 김상현;마대영;김현희;김영석;조강욱;최효상
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 1996년도 춘계학술대회 논문집
    • /
    • pp.178-184
    • /
    • 1996
  • Electrical properties such as surface flashover discharge and discharge degradations of insulating materials for superconducting cable have been investigated. It is found that the surface voltage is proportional to /$\^$0.7/(/: discharge length) in LHe(Liquid Helium). V-t characteristic LHe were a n=5.5 that was less than liquid N$_2$. After applied AC voltage, the surface condition of polymer films were observed non-eroded area and eroded area. The eroded area is depending on the applied voltage. In case of LHe, the crack was observed.

  • PDF

폴리피롤을 이용한 약물전달시스템 (Using Polypyrrole for Drug Delivery System)

  • 이상조;이승기;오명환;박정호
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2002년도 추계학술대회 논문집 Vol.15
    • /
    • pp.448-451
    • /
    • 2002
  • The possibility of using polypyrrole as a drug delivery system(DDS) has been studied using indicate (Phenol red) and substance with therapeutic activity(Sodium salicylate). In aqueous solution, negative potential is applied to polypyrrole then anion(with therapeutic activity) of sodium salicylate is released by redox processes of polypyrrole. The release amount of anionic drugs from polypyrrole is measured by UV-visible spectrometer which can measure UV-absorbance of materials. Electrode area that use for release amount measurement is$50mm^{2}(5{\times}10mm)$,and thickness of polypyrrole membrane is $15{\mu}m$. DC 1V applied in saline solution, the release amount according to time increased gradually. In various electrode area, release amount of anionic drug is directly to electrode area.

  • PDF

그래핀 공진기 기반의 나노 센서에 대한 연구 (A Study of Nano Sensor based on Graphene Resonator)

  • 이준하
    • 반도체디스플레이기술학회지
    • /
    • 제16권1호
    • /
    • pp.102-105
    • /
    • 2017
  • Currently, the size of the electronic device is in the nano area. In order to control the movements of these nanoscale devices, one should be able to understand the physical phenomena in the nano area. Recently, due to carbon nanotubes and mechanical outstanding electrical conductivity and mechanical characteristics of the carbon nanotubes and Graphene behaves to apply. Efforts have been active. There are various tubes with a radius of a in a compact mass in the form of a Multi walled carbon nanotubes in different between the radius. Van der Waals force can move smoothly without friction with each other by the nanoscale motor turning, using the properties, making. This is the lightest solids per unit area on the thickness is electrical atomic layer one of the substance and the electrical conductivity, the best material and mechanical characteristics are very much. Many studies because great is the ideal nanoelectromechanical device of material is being considered. In this study, electrical resonator for a new structure proposed and the nature and methodology would like to come up.

  • PDF

유기지방산(DMPC)의 전기 특성에 관한 연구 (A Study on the Electrical Properties of Organic Fatty Acid(DMPC))

  • 송진원;구할본;김형곤;신석두;김영진;최영일;이경섭
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 1999년도 춘계학술대회 논문집
    • /
    • pp.45-48
    • /
    • 1999
  • Monolayers of lipids on a water surface have attracted much interest as models of biological membranes, but also as precursors of multilayer systems promising many technical applications. Until now, many methodologies have been developed in order to gain a better underst. DMPC molecules have one phosphatidylcholine head group and two long alkyl groups with carbonyl group. Displacement currents generated during the compression of monolayers of DMPC on the surface of water were investigated. As results, the displacement pick was generated when the area per molecule was about 190$\AA$$^2$in low pressure, and it was generated when the area per molecule about 190$\AA$$^2$ in for pressure, and it was generated when the area per molecule about 150 $\AA$$^2$ in high pressure. Also. for the study of photo device measured the absorption rate. the maxim value shown was 2800-2900nm.

  • PDF

나노기술을 위한 유기초박막의 유전완화특성 (Dielectric Relaxation Properties of Organic Ultra Thin Films for Nanotechnology)

  • 조수영;송진원;이경섭
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2004년도 춘계학술대회 논문집
    • /
    • pp.9-13
    • /
    • 2004
  • In this paper, evaluation of physical properties about dielectric relaxation phenomena by the detection of the surface pressures and displacements current on the monolayer films of phospolipid monomolecular DLPC, DMPC using pressure stimulus. As a result, the changed surface pressure, displacement current and the transition forms of dipole moment of phospolipid monomolecular in area per molecular by pressure stimulus were conformed well. It was known that the monolayers by linear relationship for decision of dielectric relaxation time between compressure speed and molecule area By according to the linear relationship relation get that frictional constant, DLPC was $1.89{\times}10^{-19}$[Js] and DMPC was $0.722{\times}10^{-19}$[Js]. It is found that the phospolipid monolayer of dielectric relaxation takes a little time and depend on the molecular area.

  • PDF

수평원관내 체적변화를 고려한 얼음의 용용시 전열특성에 관한 연구 (Melting of Ice Inside a Horizontal Cylinder under the Volume Change)

  • 조남철;김동춘;이채탈;임장순
    • 설비공학논문집
    • /
    • 제13권12호
    • /
    • pp.1266-1274
    • /
    • 2001
  • Heat transfer phenomena during melting process of the phase change material (ice) was studied by numerical analysis and experiments. In a horizontal ice storage tube, the natural convection caused an increase in melting rate. However, the reduction of the heating surface area caused a decrease in melting rate. Therefore, during the melting process of ice in a horizontal cylinder, the reduction of the heating surface area should be considered. Under the same heating wall and initial water temperature condition, the melting rate became higher for $V_s/V_tot/=0.545 \;than \;that\; for\; V_s/V_tot$/=1.00 due to the difference in the reduction of heating surface area. A modified melting model considering the equivalent thermal conductivity of liquid phase and volume reduction was proposed. The results of the model were compared with the measured values and found to be in good agreement.

  • PDF

Organic Vapor Phase Deposition 방식을 이용한 펜타센 유기박막트랜지스터의 제작 (Fabrication of Pentacene Thin Film Transistors by using Organic Vapor Phase Deposition System)

  • 정보철;송정근
    • 한국전기전자재료학회논문지
    • /
    • 제19권6호
    • /
    • pp.512-518
    • /
    • 2006
  • In this paper, we investigated the deposition of pentacene thin film on a large area substrate by Organic Vapor Phase Deposition(OVPD) and applied it to fabrication of Organic Thin Film Transistor(OTFT). We extracted the optimum deposition conditions such as evaporation temperature of $260^{\circ}C$, carrier gas flow rate of 10 sccm and chamber vacuum pressure of 0.1 torr. We fabricated 72 OTFTs on the 4 inch size Si Wafer, Which produced the average mobility of $0.1{\pm}0.021cm^2/V{\cdot}s$, average subthreshold slope of 1.04 dec/V, average threshold voltage of -6.55 V, and off-state current is $0.973pA/{\mu}m$. The overall performance of pentacene TFTs over 4 ' wafer exhibited the uniformity with the variation less than 20 %. This proves that OVPD is a suitable methode for the deposition of organic thin film over a large area substrate.

이온농도에 의한 IMI-O고분자 LB막의 전기특성 (Electrical Properties of IMI-O Polymeric LB Films Using logic Concentration)

  • 정상범;유승엽;박재철;권영수
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 1997년도 추계학술대회 논문집
    • /
    • pp.418-420
    • /
    • 1997
  • We synthesized the polymer that can have function group and improvement of mechnical strength and then confirmed the possibility of molecular device made by LB method. In this paper, the $\pi$-A isotherm has been investigated as to the kinds and various concentrations of the metal ions complexed with imidazole group. The experimental results for the electrical properties of MIM fabricated has been obtained as following. There is no change in limiting area as to the kinds of the metal ions, also the shift of conductivity as to the metal ions couldn't be observed, which was 10$\^$-14/[S/cm]. There are some changes in limiting area as to the concentration of the metal ions, the conductivity shift was increased with the occupied molecular area.

  • PDF

초소형 전자칼럼의 대면적 주사 적정조건 (The Optimal Condition for Scanning Large Area with a Micro-electron-column)

  • 박성순;김호섭;장원권
    • 한국전기전자재료학회논문지
    • /
    • 제20권6호
    • /
    • pp.481-486
    • /
    • 2007
  • In large area scanning with a micro-electron-column, the operating condition for the best resolution was investigated in factors of working distance and field of view. The resolution of a test sample was dependent on electron beam energy and scanning field size. The best resolution with single deflector was obtained at 300 V and 30 mm in the electron emitting tip voltage and a working distance, respectively. The scanning area at that condition was $13.9{\times}13.9mm^2$, linearly increased with the working distance. Double deflector was employed for larger scanning size without increasing working distance, but showed only 1.7 times larger than that of single deflector, and the resolution was inverse proportional to the scanning size.

대면적 플라즈마 소스에의 E-ICP 적용과 그 효과 비교 (Comparison of E-ICP Effect for Large Area Plasma Source)

  • 김진우;손민영;박세근;오범환
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2000년도 하계학술대회 논문집
    • /
    • pp.608-611
    • /
    • 2000
  • Large area plasma source becomes important as the substrate size increases. In this work, four inductively coupled plasma(ICP) unit sources are distributed 2${\times}$2 array. E-ICP concept is applied to the 2${\times}$2 array ICP and its effect is examined. Characteristics of the plasma are measured, and photoresist etching is performed with oxygen plasma. Good etching characteristic in terms of etching rate and uniformity can be obtained with E-ICP.

  • PDF