Transactions of the Korean Society of Mechanical Engineers B
/
v.28
no.10
/
pp.1219-1230
/
2004
Comparing to the gravimetric and volumetric method, the flowmeter calibration based on the master meter method is relatively economical and convenient, especially for high flowrate. The uncertainty of flow quantity and flowrate using the master meter method was evaluated according to the GUM (Guide to the Expression of Uncertainty in Measurement). In order to apply for the wider flow range, two master meters (electromagnetic flow meter) were employed as reference flowmeters. The uncertainty of the master meter was obtained by combining the statistical variation of the repeated measurements and the variation of fluid density and pipe material due to temperature and pressure changes were scrutinized. for a practical application, the uncertainty of calibrator, whose measuring capacity of 1000 ㎥/h obtained by employing two 500 ㎥/h electromagnetic How meters, was evaluated. The uncertainty budget shows the quantitative contribution of each uncertainty component to the overall uncertainty of the calibrator. As a result, it was found that the dominant uncertainties were from the master meter, which was evaluated statistically, and from the process of least squares fitting. On the contrary, the uncertainties arising from the variation of the fluid density and the pipe volume due to the temperature and pressure were negligible.
Training for radiation protection and control requires a visual understanding of radiation, which cannot be perceived by the human senses. Trainees must also master the effective use of measuring instruments. Traditionally, such training has exposed trainees to radiation sources. Here, we present a novel e-training strategy that enables safe, exposure-free handling of a radiation measuring tool called a survey meter. Our mixed reality radiation-training system merges the physical world with a digital one. Collaborating with a mixed reality headset (HoloLens 2), this system constructs a mock-up of a survey meter in real-world space. The HoloLens 2 employs a browser-based application to visualize radiation and to simulate/share the use of the survey meter, including its physical movements. To provide a dynamic learning experience, the system adjusts the survey-meter mock-up readings according to the operator's movements, distance from the radiation source, the response time of survey meter, and shielding levels. Through this approach, we expect that trainees will acquire practical skills in interpreting survey-meter readings and gain a visual understanding of radiation in real-world situations.
Hydrogen is difficult to accurately measure the amount of charge due to sudden temperature changes and pressure rise when charging the vehicle. In order to construct a hydrogen infrastructure, it is important to precisely measure the amount of charge that can be a sensitive issue in commercial transactions. In this study, the accuracy of metering of domestic hydrogen stations was evaluated as a study for metering management of hydrogen dispenser. For the experiment, we constructed metering system using master meter method and measured the flow rate in the actual hydrogen vehicle charging environment. As a result of error occurred about 10% on average, and the hydrogen loss per one charge was found to be up to 60g.
Proceeding of Spring/Autumn Annual Conference of KHA
/
2005.11a
/
pp.189-192
/
2005
The purpose of this study is to analyze space composition and size of the Master Zone in the apartment unit plan. For this, we analyzed 435 samples by searching web-sites of the 5 main construction companies. The major results of this study are as follows. 1) Master Zone is organized 4 spaces such as main room, bathroom and make-up & dress room. Six types of Master Zone are classified with the composition of 4 spaces. 2) The size of the Master Zone is increased in proportion to the square meter. But the range of the ratio is small range of fluctuation as 20%${\sim}$30%. 3)The size and ratio of the each spaces of the Master Zone are analyzed. The size of bedroom is increased but the ratio is decreased. The size of bathroom is increased but the ratio is regular as 4%${\sim}$5%. The size of make-up and dressing room is generally increased but the range of the size and ratio is the most extensive. Through this analysis and research, this study would be provied the basic data for actual housing planning and to contribute to future trends of apartment houses.
The Journal of Korean Institute of Communications and Information Sciences
/
v.41
no.11
/
pp.1574-1579
/
2016
This paper presents a self-powered sensor-node scheme using a RF wireless power harvesting techniques for improve drone time of flight. Sensor-node that is proposed is turned when two conditions satisfy: The one is input RF ID data from master-node should be same with sensor-node's ID, and the other one is RF wireless power harvesting system is turned on by hysteresis switch. In this paper, master-node's output is 26 dBm at 263 MHz. Maximum RF to DC power conversion efficiency is about 55% at 4-6 dBm input power condition (2 meter from master-node). The maximum RF wireless power harvesting range is about 13 meter form master-node. And power consumption of the sensor-node's load elements such as transmitter, MCU and temperature sensors is approximately average 15 mA at 5.0 V for 10 msec.
We prepared 8 samples of non-silver and silver-added master alloys containing silicon to confirm the existence of nickel-silicides. We then prepared products made of 14K and 18K white gold by using the prepared master alloys containing 0.25, 0.35, and 0.50 wt% silicon to check for nickel release. We then employed the EN 1811 testing standard to investigate the nickel release of the white gold products, and we also confirmed the color of the white gold products with an UV-VIS-NIR-color meter. We observed $NiSi_x$ residue in all master alloys containing more than 0.50 wt% Si with EDS-nitric acid etching. For the white gold products, we could not confirm the existence of $NiSi_x$ through XRD after aqua-regia etching. In the EN 1811 test, only the white gold products with 0.25 wt% silicon master alloys successfully passed the nickel release regulations. Moreover, we confirmed that our white gold products showed excellent Lab indices as compared to those of commercial white gold ones, and the silver-added master alloys offered a larger L index. Our results indicate that employing 0.25 wt% silicon master alloys might be suitable for white gold products without nickel-silicide defects and nickel release problems.
In this research, a real-time tele-operation system for unmanned excavator using the LTE communication system is suggested. The distance between the operator and the excavator is limitless as long as the LTE communication available. The motion and video data of the excavator is synchronized using the Vehicle Control Unit (VCU) and streamed to the operator for immersion feeling. The video is played on the operator's monitor and the motion data is used to regenerate the excavator movement on the developed master platform. In general, a excavator is tele-operated using RF signal and the maximum distance for direct control is limited to within a hundred meter. In this research, the immersion tele-operation system is suggested for excavator operation within an 100ms time delay using the developed master platform, the VCU and LTE communication. A successful test run of the suggested tele-operation system has already been performed between an operator in Songpa (Seoul) and a excavator in Ansan (Gyeonggi-do) which is approximately 35 km apart.
Statement of problem: Although the use of colorimeter to improve the accuracy of tooth color measurement has increased, it is real situation that there is almost no comparative study about the accuracy among various colorimeters. Purpose: The purpose of this study is to compare the accuracy of porcelain color reproducibility using ShadeEye-Ncc dental chroma meter (Shofu Inc., Kyoto, Japan) and Shadepilot$^{TM}$ system (Degudent Inc., Hanau, Germany). Material and methods: Color of 2M2 and 3M2 shade tap of Vitapan 3D Master shade guide were measured using the above two colorimeters. Porcelain specimens were fabricated through this data. The porcelain systems used were Vintage Halo Porcelain system with ShadeEye-Ncc dental chroma meter, and VitaOmega900 Porcelain system with Shadepilot$^{TM}$ system. Colors of shade tap models and porcelain specimen were measured with spectrophotometer, and calculated delta E based on the results. Results: The following results were obtained. 1. Shadepilot$^{TM}$ system showed more suitable porcelain color reproducibility compared to ShadeEye-Ncc dental chroma meter (P <.05). 2. The result showed the difference of porcelain color reproducibility according to shade of Shade tap which is model. More suitable porcelain color reproducibility was shown at 3M2 shade tap than at 2M2 shade tap (P <.05). 3. The average of ${\Delta}E*$ of porcelain specimens which was made by the two colorimeters was 4.44-6.14, so the difference of shade was shown through the naked eye. Conclusion: Shadepilot$^{TM}$ system showed more suitable porcelain color reproducibility. When using ShadeEye-Ncc dental chromameter, it will be necessary to improve accuracy through coloring various parts of the whole tooth.
Statement of problem: Shade selection has traditionally been accomplished by visual examination, which is particularly relevant to the shade selection of anterior teeth, but the subjective nature of visual analysis can lead to errors in shade matching. Recently shade selection systems have been developed to provide a more objective and scientific approach to understanding and clarifying shade selection. Purpose : The purpose of this study was analysis of various shade analyzing equipment with the goal of providing a more objective shade selection. Materials and method: Visual shade matching system selection(Vita Lumin Vacuum shade guide, Vitapan 3D Master shade guide) and mechanical shade matching method($ShadeEye^{(R)}$-EX Chroma Meter, $Shadescan^{TM}$ System) used for this study. The shade guide tap specimens for 10 extracted maxillary anterior teeth were produced by selecting shades using each shade matching system. The accuracy of the selection of shades for the teeth and fabricated specimens were evaluated by analyzing the calculated shade difference(${\Delta}E^*$), using a spectrophotometer and calculating the output of value $L^*,\;a^*,\;b^*$. Results and conclusion: The results show that the average ${\{Delta}E^*$ value (difference of shade) of the shade tap specimens to the actual specimen decreased in the following order: Vita Lumin Vacuum Shade Guide(VL), $ShadeEye^{(R)}$-EX Chroma Meter(SE) Vitapan 3D Master Shade guide(V3), and $Shadescan^{TM}$ System(55) : and that there are significant statistical differences between the VL and SS (p<0.05). In the analysis of the ${\Delta}E^*$ (difference of shade) value,40% of the VL group was found to be less than 3.3 (limit value of shade tap specimens clinically acceptable), 60% in the V3 group, 50% in the SE group, and 80% in the SS group.
Transactions of the Korean Society of Mechanical Engineers
/
v.14
no.1
/
pp.259-266
/
1990
Leaks at the piston seal and the by-pass port of a small volume prover have relatively large influence on the proving accuracy in comparison with a conventional ball prover. The pulse interpolator, which is to increase the discrimination, is affected by the characteristic of the flowmeter signal. In this study, a small volume prover of the double cylinder type was designed in order to study the pulse interpolation error as well as the leak error. The basic volume of the prover determined by a water draw method was about 9.68L. Experimental results revealed that interpolation data attained by the repeated piston pass for turbine meters at a fixed flowrate may be treated effectively by applying a statistical method. It was possible to limit the pulse interpolation error less than .+-. 0.02% at the 95% confidence level. However, in the case of the bulk meter, if failed to achieve the required repeatability level because of the pulse characteristics. The basic volume change appeared to be independent of the piston velocity within the .+-. 0.05% of tolerance.
본 웹사이트에 게시된 이메일 주소가 전자우편 수집 프로그램이나
그 밖의 기술적 장치를 이용하여 무단으로 수집되는 것을 거부하며,
이를 위반시 정보통신망법에 의해 형사 처벌됨을 유념하시기 바랍니다.
[게시일 2004년 10월 1일]
이용약관
제 1 장 총칙
제 1 조 (목적)
이 이용약관은 KoreaScience 홈페이지(이하 “당 사이트”)에서 제공하는 인터넷 서비스(이하 '서비스')의 가입조건 및 이용에 관한 제반 사항과 기타 필요한 사항을 구체적으로 규정함을 목적으로 합니다.
제 2 조 (용어의 정의)
① "이용자"라 함은 당 사이트에 접속하여 이 약관에 따라 당 사이트가 제공하는 서비스를 받는 회원 및 비회원을
말합니다.
② "회원"이라 함은 서비스를 이용하기 위하여 당 사이트에 개인정보를 제공하여 아이디(ID)와 비밀번호를 부여
받은 자를 말합니다.
③ "회원 아이디(ID)"라 함은 회원의 식별 및 서비스 이용을 위하여 자신이 선정한 문자 및 숫자의 조합을
말합니다.
④ "비밀번호(패스워드)"라 함은 회원이 자신의 비밀보호를 위하여 선정한 문자 및 숫자의 조합을 말합니다.
제 3 조 (이용약관의 효력 및 변경)
① 이 약관은 당 사이트에 게시하거나 기타의 방법으로 회원에게 공지함으로써 효력이 발생합니다.
② 당 사이트는 이 약관을 개정할 경우에 적용일자 및 개정사유를 명시하여 현행 약관과 함께 당 사이트의
초기화면에 그 적용일자 7일 이전부터 적용일자 전일까지 공지합니다. 다만, 회원에게 불리하게 약관내용을
변경하는 경우에는 최소한 30일 이상의 사전 유예기간을 두고 공지합니다. 이 경우 당 사이트는 개정 전
내용과 개정 후 내용을 명확하게 비교하여 이용자가 알기 쉽도록 표시합니다.
제 4 조(약관 외 준칙)
① 이 약관은 당 사이트가 제공하는 서비스에 관한 이용안내와 함께 적용됩니다.
② 이 약관에 명시되지 아니한 사항은 관계법령의 규정이 적용됩니다.
제 2 장 이용계약의 체결
제 5 조 (이용계약의 성립 등)
① 이용계약은 이용고객이 당 사이트가 정한 약관에 「동의합니다」를 선택하고, 당 사이트가 정한
온라인신청양식을 작성하여 서비스 이용을 신청한 후, 당 사이트가 이를 승낙함으로써 성립합니다.
② 제1항의 승낙은 당 사이트가 제공하는 과학기술정보검색, 맞춤정보, 서지정보 등 다른 서비스의 이용승낙을
포함합니다.
제 6 조 (회원가입)
서비스를 이용하고자 하는 고객은 당 사이트에서 정한 회원가입양식에 개인정보를 기재하여 가입을 하여야 합니다.
제 7 조 (개인정보의 보호 및 사용)
당 사이트는 관계법령이 정하는 바에 따라 회원 등록정보를 포함한 회원의 개인정보를 보호하기 위해 노력합니다. 회원 개인정보의 보호 및 사용에 대해서는 관련법령 및 당 사이트의 개인정보 보호정책이 적용됩니다.
제 8 조 (이용 신청의 승낙과 제한)
① 당 사이트는 제6조의 규정에 의한 이용신청고객에 대하여 서비스 이용을 승낙합니다.
② 당 사이트는 아래사항에 해당하는 경우에 대해서 승낙하지 아니 합니다.
- 이용계약 신청서의 내용을 허위로 기재한 경우
- 기타 규정한 제반사항을 위반하며 신청하는 경우
제 9 조 (회원 ID 부여 및 변경 등)
① 당 사이트는 이용고객에 대하여 약관에 정하는 바에 따라 자신이 선정한 회원 ID를 부여합니다.
② 회원 ID는 원칙적으로 변경이 불가하며 부득이한 사유로 인하여 변경 하고자 하는 경우에는 해당 ID를
해지하고 재가입해야 합니다.
③ 기타 회원 개인정보 관리 및 변경 등에 관한 사항은 서비스별 안내에 정하는 바에 의합니다.
제 3 장 계약 당사자의 의무
제 10 조 (KISTI의 의무)
① 당 사이트는 이용고객이 희망한 서비스 제공 개시일에 특별한 사정이 없는 한 서비스를 이용할 수 있도록
하여야 합니다.
② 당 사이트는 개인정보 보호를 위해 보안시스템을 구축하며 개인정보 보호정책을 공시하고 준수합니다.
③ 당 사이트는 회원으로부터 제기되는 의견이나 불만이 정당하다고 객관적으로 인정될 경우에는 적절한 절차를
거쳐 즉시 처리하여야 합니다. 다만, 즉시 처리가 곤란한 경우는 회원에게 그 사유와 처리일정을 통보하여야
합니다.
제 11 조 (회원의 의무)
① 이용자는 회원가입 신청 또는 회원정보 변경 시 실명으로 모든 사항을 사실에 근거하여 작성하여야 하며,
허위 또는 타인의 정보를 등록할 경우 일체의 권리를 주장할 수 없습니다.
② 당 사이트가 관계법령 및 개인정보 보호정책에 의거하여 그 책임을 지는 경우를 제외하고 회원에게 부여된
ID의 비밀번호 관리소홀, 부정사용에 의하여 발생하는 모든 결과에 대한 책임은 회원에게 있습니다.
③ 회원은 당 사이트 및 제 3자의 지적 재산권을 침해해서는 안 됩니다.
제 4 장 서비스의 이용
제 12 조 (서비스 이용 시간)
① 서비스 이용은 당 사이트의 업무상 또는 기술상 특별한 지장이 없는 한 연중무휴, 1일 24시간 운영을
원칙으로 합니다. 단, 당 사이트는 시스템 정기점검, 증설 및 교체를 위해 당 사이트가 정한 날이나 시간에
서비스를 일시 중단할 수 있으며, 예정되어 있는 작업으로 인한 서비스 일시중단은 당 사이트 홈페이지를
통해 사전에 공지합니다.
② 당 사이트는 서비스를 특정범위로 분할하여 각 범위별로 이용가능시간을 별도로 지정할 수 있습니다. 다만
이 경우 그 내용을 공지합니다.
제 13 조 (홈페이지 저작권)
① NDSL에서 제공하는 모든 저작물의 저작권은 원저작자에게 있으며, KISTI는 복제/배포/전송권을 확보하고
있습니다.
② NDSL에서 제공하는 콘텐츠를 상업적 및 기타 영리목적으로 복제/배포/전송할 경우 사전에 KISTI의 허락을
받아야 합니다.
③ NDSL에서 제공하는 콘텐츠를 보도, 비평, 교육, 연구 등을 위하여 정당한 범위 안에서 공정한 관행에
합치되게 인용할 수 있습니다.
④ NDSL에서 제공하는 콘텐츠를 무단 복제, 전송, 배포 기타 저작권법에 위반되는 방법으로 이용할 경우
저작권법 제136조에 따라 5년 이하의 징역 또는 5천만 원 이하의 벌금에 처해질 수 있습니다.
제 14 조 (유료서비스)
① 당 사이트 및 협력기관이 정한 유료서비스(원문복사 등)는 별도로 정해진 바에 따르며, 변경사항은 시행 전에
당 사이트 홈페이지를 통하여 회원에게 공지합니다.
② 유료서비스를 이용하려는 회원은 정해진 요금체계에 따라 요금을 납부해야 합니다.
제 5 장 계약 해지 및 이용 제한
제 15 조 (계약 해지)
회원이 이용계약을 해지하고자 하는 때에는 [가입해지] 메뉴를 이용해 직접 해지해야 합니다.
제 16 조 (서비스 이용제한)
① 당 사이트는 회원이 서비스 이용내용에 있어서 본 약관 제 11조 내용을 위반하거나, 다음 각 호에 해당하는
경우 서비스 이용을 제한할 수 있습니다.
- 2년 이상 서비스를 이용한 적이 없는 경우
- 기타 정상적인 서비스 운영에 방해가 될 경우
② 상기 이용제한 규정에 따라 서비스를 이용하는 회원에게 서비스 이용에 대하여 별도 공지 없이 서비스 이용의
일시정지, 이용계약 해지 할 수 있습니다.
제 17 조 (전자우편주소 수집 금지)
회원은 전자우편주소 추출기 등을 이용하여 전자우편주소를 수집 또는 제3자에게 제공할 수 없습니다.
제 6 장 손해배상 및 기타사항
제 18 조 (손해배상)
당 사이트는 무료로 제공되는 서비스와 관련하여 회원에게 어떠한 손해가 발생하더라도 당 사이트가 고의 또는 과실로 인한 손해발생을 제외하고는 이에 대하여 책임을 부담하지 아니합니다.
제 19 조 (관할 법원)
서비스 이용으로 발생한 분쟁에 대해 소송이 제기되는 경우 민사 소송법상의 관할 법원에 제기합니다.
[부 칙]
1. (시행일) 이 약관은 2016년 9월 5일부터 적용되며, 종전 약관은 본 약관으로 대체되며, 개정된 약관의 적용일 이전 가입자도 개정된 약관의 적용을 받습니다.