• Title/Summary/Keyword: mass size

Search Result 2,532, Processing Time 0.031 seconds

Improvement of Sense Mode Bandwidth of Vibratory Silicon-On-Glass Gyroscope Using Dual-Mass System (이중 질량체를 사용한 진동형 자이로스코프의 검출부 대역폭 개선)

  • Hwang, Yong-Suk;Kim, Yong-Kweon;Ji, Chang-Hyeon
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.60 no.9
    • /
    • pp.1733-1740
    • /
    • 2011
  • In this research, a MEMS vibratory gyroscope with dual-mass system in the sensing mode has been proposed to increase the stability of the device using wide bandwidth. A wide flat region between the two resonance peaks of the dual-mass system removes the need for a frequency matching typically required for single mass vibratory gyroscopes. Bandwidth, mass ratio, spring constant, and frequency response of the dual-mass system have been analyzed with MATLAB and ANSYS simulation. Designed first and second peaks of sensing mode are 5,917 and 8,210Hz, respectively. Driving mode resonance frequency of 7,180Hz was located in the flat region between the two resonance peaks of the sensing mode. The device is fabricated with anodically bonded silicon-on-glass substrate. The chip size is 6mm x 6mm and the thickness of the silicon device layer is $50{\mu}m$. Despite the driving mode resonance frequency decrease of 2.8kHz and frequency shift of 176Hz from the sensing mode due to fabrication imperfections, measured driving frequency was located within the bandwidth of sensing part, which validates the utilized dual-mass concept. Measured bandwidth was 768Hz. Sensitivity calculated with measured displacement of driving and sensing parts was 22.4aF/deg/sec. Measured slope of the sensing point was 0.008dB/Hz.

A Survey of Human Injury and Crowd Packing in Mass Gathering (군중집회 시의 인명피해 및 군중눌림 현상의 고찰)

  • Wang, Soon-Joo;Byun, Hyun-Joo
    • Journal of the Society of Disaster Information
    • /
    • v.7 no.1
    • /
    • pp.12-20
    • /
    • 2011
  • This study was performed for identifying the characteristics of mass gathering and human injury in mass gathering based on the literature survey and analysis of mass gathering and crowd packing. The size and density of crowd influenced the characteristics of mass gathering according to type of mass gathering. The variables and causes of human injuries of mass gathering have positive or negative influences based on the weather, attendance, duration, location, mobility, event type, crowd mood, alcohol, drug, crowd density and age. Based on the physical mechanism of crowd packing, the degree of crowd packing was influenced by crowd pressure, crowd density and lasting time. But the magnitude of pressure for pedestrian injury criteria remains for further research.

Characteristics of Block Hydraulic Conductivity of 2-D DFN System According to Block Size and Fracture Geometry (블록크기 및 균열의 기하학적 속성에 따른 2-D DFN 시스템의 블록수리전도도 특성)

  • Han, Jisu;Um, Jeong-Gi
    • Tunnel and Underground Space
    • /
    • v.25 no.5
    • /
    • pp.450-461
    • /
    • 2015
  • Extensive numerical experiments have been carried out to investigate effect of block size and fracture geometry on hydraulic characteristics of fractured rock masses based on connected pipe flow in DFN systems. Using two fracture sets, a total of 72 2-D fracture configurations were generated with different combinations of fracture size distribution and deterministic fracture density. The directional block conductivity including the theoretical block conductivity, principal conductivity tensor and average block conductivity for each generated fracture network system were calculated using the 2-D equivalent pipe network method. There exist significant effects of block size, orientation, density and size of fractures in a fractured rock mass on its hydraulic behavior. We have been further verified that it is more difficult to reach the REV size for the fluid flow network with decreasing intersection angle of two fracture sets, fracture plane density and fracture size distribution.

A Study on Evaluation for Sampling and Analytical Methods of Diatomaceous Earth Dust (규조토 분진 측정 및 분석 방법의 비교에 관한 연구)

  • Lim, Hyun Sul;Kim, Ji Yong;Cheong, Hoe Kyeong
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.5 no.2
    • /
    • pp.212-225
    • /
    • 1995
  • This study was performed in a diatomite factory located at Pohang City, Kyeongsangbuk-Do. The major objectives were to evaluate sampling and analytical methods of diatomaceous earth dust. Concentrations of total and respirable diatomaceous earth dust were measured. Size distribution of dust was analyzed by a personal cascade impactor and the particle size analyzer which is an application of multiple diffraction method. Also crystalline silica in respirable and total dust samples was analyzed quantitatively by X-ray diffraction and Fourie Transform Infrared Spectroscopy(FTIR). The results were as follows: The airborne total and respirable dust concentrations, particle size distribution, and cristalline silica(quartz) concentrations showed approximately a log-normal distribution. The means of totaldust concentrations at flour maufacturing, fire brick grinding and packaging processes exceeded the Korean and American Conference of Governmental Industrial Hygienists standards, $10mg/m^3$. The size distribution of diatomaceous earth dust was log-normal and identified as the rspirable particle mass and thoracic particle mass. The crystalline silica in respirable and total dust samples was identified to quartz and contained about 10 % in those samples. Finally, it is necessary to study the applicability of multiple diffraction for particle size distribution to compare the ACGIH's size selective sampling with other materials containing crystalline silica. Also, advanced quantitative study to X-ray diffraction and FTIR methods shoud be carried out 10 verify general and specific characteristics for respirable crystalline silica.

  • PDF

Measurement of Atmospheric Dry Deposition and Size Distribution of Particulate PCBs in 1999 at Seoul

  • Park, Seong-Suk;Shin, Hye-Joung;Yi, Seung-Muk;Kim, Yong-Pyo
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.22 no.E1
    • /
    • pp.35-43
    • /
    • 2006
  • Ambient particle size distributions of PCBs and their dry deposition fluxes were measured at a site in Seoul to quantify dry deposition fluxes of PCBs and size characteristics of PCBs in the air, and to estimate ambient concentrations of gaseous PCBs and dry deposition fluxes. The dry deposition plate was used to measure dry deposition fluxes of particulate mass and PCBs and a cascade impactor and rotary impactor were used to measure ambient particle size distributions for small ($D_p<9{\mu}m$) and large ($D_p>9{\mu}m$) particles, respectively. Six sample sets were collected from April to July 1999. The fluxes of particulate total PCBs (the sum of 43 congeners) ranged from 160 to $607ng\;m^{-2}day^{-1}$. The size distribution of total PCBs was bimodal with two peaks in small particle size ($D_p{\sim}0.6\;and\;6{\mu}m$, respectively) and, thus, mass concentration being dominant in small particles. The mean particulate PCBs concentration was $6.9{\mu}g$ PCBs/g. The concentrations of PCB homologues in the gas phase were estimated based on the particle/gas partition coefficient ($K_p$) with the measured values of particulate PCBs in this study and they were comparable to those observed in other previous studies. Dry deposition fluxes were estimated by calculating dry deposition velocities.

Relationship Between Curvature Angle and BMI According to Wearing a Scoliosis Brace (척추측만증보조기 착용에 따른 만곡각도와 체질량지수의 관계)

  • Lee, Gwangho
    • Journal of The Korean Society of Integrative Medicine
    • /
    • v.7 no.3
    • /
    • pp.149-157
    • /
    • 2019
  • Purpose : This study aims to check the relationship between the size of curvature in scoliosis patients and the reduction rate of curvature after wearing a brace and the relationships of the size of curvature and correction angle with Body Mass Index (BMI). Methods : With 30 adolescent girls who had never worn a brace, their Cobb angle and BMI were measured before manufacturing braces, and their corrected Cobb angle was measured after wearing the manufactured scoliosis braces. Results : The size of the major curvature before wearing the brace and the reduction rate of the curvature after putting it on had a negative correlation in both the major curvature (r=-.465, p<.01) and the minor curvature (r=-.516, p<.01). The size of the minor curvature and the reduction rate of the minor curvature before and after putting it on also had a negative correlation (r=-.429, p<.05). As for the relationship between the size of curvature and BMI, they had a negative correlation in both the major curvature (r=-.141) and the minor curvature (r=-.123), and as for the relationship between the reduction rate of curvature and BMI after wearing the brace, they had a positive correlation in both the major curvature (r=.251) and the minor curvature (r=.136); however, it was not statistically significant (p>.05). Conclusion : In conclusion, the larger the size of curvature, the lower the reduction rate of curvature after wearing the brace became. The larger the size of curvature, the lower the BMI became. The higher the BMI, the higher the correction ratio of the brace became. Therefore, it is judged that it is necessary to provide early treatment and manage body composition before scoliosis progresses.

Elemental components analysis according to the size of fine particles emitted from a coal-fired power plant using an ejector-porous tube dilution sampling and ELPI (이젝터-다공튜브 희석 샘플링과 ELPI를 이용한 석탄화력발전소 배출 미세먼지의 입자 크기에 따른 성분 분석)

  • Shin, Dongho;Park, Daehoon;Joe, Yunhui;Kim, Younghun;Hong, Kee-Jung;Lee, Gunhee;Han, Bangwoo;Hwang, Jungho
    • Particle and aerosol research
    • /
    • v.18 no.3
    • /
    • pp.69-77
    • /
    • 2022
  • In order to understand the characteristics of fine particles emitted from coal-fired power plant stacks, it is important to analyze the size distribution and components of particles. In this study, particle size distributions were measured using the ejector-porous tube dilution device and an ELPI system at a stack in a coal-fired power plant. Main elemental components of particles in each size interval were also identified through TEM-EDS analysis for the particles collected in each ELPI stage. Particle size distributions based on number and mass were analyzed with component distributions from 0.006 to 10 ㎛. The highest number concentration was about 0.01 ㎛. The main component of the particles consisted of sulfur, which indicated that sulfate aerosols were generated by gas-to-particle conversion of SO2. In a mass size distribution, a mono-modal distribution with a mode diameter of about 2 ㎛ was shown. For the components of PM1.0 (particles less than 1 ㎛), the abundance order was F > Mg > S > Ca, and however, for the components of PM10 (particles less than 10 ㎛), it was in the order of Fe > S > Ca > Mg. The elemental components by particle size were confirmed.

Estimation of Mass Size Distribution of Atmospheric Aerosols Using Real-Time Aerosol Measuring Instruments (실시간 에어로졸 측정장비를 이용한 대기 중 입자상 물질의 무게 농도 분포의 추정)

  • Ji, Jun-Ho;Bae, Gwi-Nam
    • Particle and aerosol research
    • /
    • v.9 no.2
    • /
    • pp.39-50
    • /
    • 2013
  • Real-time aerosol measuring instruments have been widely used for the measurement of atmospheric aerosol, diesel particulate matter, or material synthesis. A scanning mobility particle sizer (SMPS) measures the number size distribution of particles using electrical mobility detection technique. An aerodynamic particle sizer (APS) is used to determine the number concentration and the mean aerodynamic diameter of test particles. An electrical low-pressure impactor (ELPI) is a multi-stage impaction device to separate airborne particles into aerodynamic size classes using particle charging and electrical detection techniques. In this study, the performance of these instruments were evaluated to assess their ability to obtain mass concentrations from particle number concentration measurements made as a function of particle size. The effect of determination of particle density on the measurement of mass concentration was investigated for the three instruments.

Analysis of the mechanical properties and failure modes of rock masses with nonpersistent joint networks

  • Wu, Yongning;Zhao, Yang;Tang, Peng;Wang, Wenhai;Jiang, Lishuai
    • Geomechanics and Engineering
    • /
    • v.30 no.3
    • /
    • pp.281-291
    • /
    • 2022
  • Complex rock masses include various joint planes, bedding planes and other weak structural planes. The existence of these structural planes affects the mechanical properties, deformation rules and failure modes of jointed rock masses. To study the influence of the parameters of a nonpersistent joint network on the mechanical properties and failure modes of jointed rock masses, synthetic rock mass (SRM) technology based on discrete elements is introduced. The results show that as the size of the joints in the rock mass increases, the compressive strength and the discreteness of the rock mass first increase and then decrease. Among them, the joints that are characterized by "small but many" joints and "large and clustered" joints have the most significant impact on the strength of the rock mass. With the increase in joint density in the rock mass, the compressive strength of rock mass decreases monotonically, but the rate of decrease gradually decreases. With the increase in the joint dip angle in rock mass, the strength of the rock mass first decreases and then increases, forming a U-shaped change rule. In the analysis of the failure mode and deformation of a jointed rock mass, the type of plastic zone formed after rock mass failure is closely related to the macroscopic displacement deformation of the rock mass and the parameters of the joints, which generally shows that the location and density of the joints greatly affect the failure mode and displacement degree of the jointed rock mass. The instability mechanism of jointed surrounding rock is revealed.

The Variation of Scan Time According to Patient's Breast Size and Body Mass Index in Breast Sentinel lymphangiography (유방암의 감시림프절 검사에서 유방크기와 체질량지수에 따른 검사시간 변화)

  • Lee, Da-Young;Nam-Koong, Hyuk;Cho, Seok-Won;Oh, Shin-Hyun;Im, Han-Sang;Kim, Jae-Sam;Lee, Chang-Ho;Park, Hoon-Hee
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.16 no.2
    • /
    • pp.62-67
    • /
    • 2012
  • Purpose : At this time, the sentinel lymph node mapping using radioisotope and blue dye is preceded for breast cancer patient's sentinel lymph node biopsy. But all patients were applied the same protocol without consideration of physical specific character like the breast sizes and body mass indexes. The purpose of this study is search the optimized scan time in breast sentinel lymphangiography by observing how much the body mass index and breast size influence speed of lymphatic flow. Materials and Methods : The Object of this study was 100 breast cancer patients(Female, 100 persons, average age $50.34{\pm}10.26$ years old)at Severance hospital from October 2011 to December 2011. They were scanned breast sentinel lymphangiography before operation. This study was performed on Forte dual heads gamma camera (Philips Medical Systems, Nederland B.V.). All patients were intra-dermal injected $^{99m}Tc$-Phytate 18.5 MBq, 0.5 ml. For 80 patients, we have scanned without limitation of scan time until the lymphatic flow from the lymph node since injection. We measured how long the lymphatic flow time between departures from injects site and arrival to lymph node using stopwatch. After we calculated patient's Body mass Index and classified as 4 groups. And we measured patient's breast size and classified 3 groups. The modified breast lymphangiography that changing scan time according to comparison study's result was performed on 20 patients and was estimated. Results : The mean scan time as breast size was A group 2.48 minutes, B group 7.69 minutes, C group 10.43 minutes. The mean scan time as body mass index was under weight 1.35 minutes, normal weight 2.56 minutes, slightly over 5.62 minutes, over weighted 5.62 minutes. The success rate of modified breast lymphangiography was 85%. Conclusion : As the Body mass index became higher and breast size became bigger, the total scan time is increased. Based on the obtained information, we designed modified breast lymphangiography protocol. At the cases applying that protocol, most of sentinel lymph nodes were visualized as lymphatic pool. In conclusion, we found that the more success rate in modified protocol considering physical individuality than study carrying out in the same protocol.

  • PDF