• 제목/요약/키워드: mass participation ratio

검색결과 15건 처리시간 0.021초

Identifying torsional eccentricity in buildings without performing detailed structural analysis

  • Tamizharasi, G.;Murty, C.V.R.
    • Earthquakes and Structures
    • /
    • 제23권3호
    • /
    • pp.283-295
    • /
    • 2022
  • Seismic design codes permit the use of Equivalent Static Analysis of buildings considering torsional eccentricity e with dynamic amplification factors on structural eccentricity and some accidental eccentricity. Estimation of e in buildings is not addressed in codes. This paper presents a simple approximate method to estimate e in RC Moment Frame and RC Structural Wall buildings, which required no detailed structural analysis. The method is validated by 3D analysis (using commercial structural analysis software) of a spectrum of building. Results show that dynamic amplification factor should be applied on torsional eccentricity when performing Response Spectrum Analysis also. Also, irregular or mixed modes of oscillation arise in torsionally unsymmetrical buildings owing to poor geometric distribution of mass and stiffness in plan, which is captured by the mass participation ratio. These irregular modes can be avoided in buildings of any plan geometry by limiting the two critical parameters (normalised torsional eccentricity e/B and Natural Period Ratio 𝜏 =T𝜃/T, where B is building lateral dimension, T𝜃 uncoupled torsional natural period and T uncoupled translational natural period). Suggestions are made for new building code provisions.

12주간의 복합운동이 비만여성의 신체조성, 체력 및 대사증후군에 미치는 영향 (Effects of a 12-week Combined Exercise Training Program on the Body Composition, Physical Fitness Levels, and Metabolic Syndrome Profiles of Obese Women)

  • 하창호;하성;소위영
    • 한국보건간호학회지
    • /
    • 제26권3호
    • /
    • pp.417-427
    • /
    • 2012
  • Purpose: The purpose of this study was to examine the effect of a 12-week combined exercise training program on the body composition, physical fitness levels, and metabolic syndrome profiles of obese women. Methods: Twelve obese women were assigned to the combined exercise training program group. The women underwent training for 70-90 min/d, three times per week for a period of 12 weeks. Paired samples t-tests were performed using SPSS ver. 17.0 for analysis of the results. Results: The results of this study showed that body-composition parameters such as weight, fat-free mass, body fat mass, body-mass index, body fat, waist-hip ratio, basal metabolic rate, and intra-abdominal fat, physical fitness parameters such as muscle strength, muscle endurance, flexibility, and cardiac endurance, and metabolic syndrome biomarkers such as triglyceride levels, high-density lipoprotein cholesterol levels, glucose levels, systolic blood pressure, and waist circumference before participation the training program differed significantly from those after participation in the training program (p<0.05). However, diastolic blood pressure before participation in the training program did not differ significantly from that after participation in the training program (p>0.05). Conclusion: We concluded that a 12-week combined exercise training program could be a good exercise program for improvement of the body composition, physical fitness levels, and metabolic syndrome profiles of obese women.

Optimal shape of LCVA for vibration control of structures subjected to along wind excitation

  • Park, Ji-Hun;Min, Kyung-Won
    • Smart Structures and Systems
    • /
    • 제10권6호
    • /
    • pp.573-591
    • /
    • 2012
  • In this study, a procedure to design an optimal LCVA that maximizes the equivalent damping ratio added to the primary structure subjected to along-wind excitation is proposed. That design procedure does not only consider the natural frequency and damping ratio of the LCVA, but also the proportion of the U-shaped liquid, which is closely related to the participation ratio of the liquid mass in inertial force. In addition, constraints to ensure the U-shape of the liquid are considered in the design process, so that suboptimal solutions that violate the optimal tuning law partly are adopted as a candidate of the optimal LCVA. The proposed design procedure of the LCVA is applied to the control of the 76-story benchmark building, and the optimal proportions of the liquid shape under various design conditions are compared.

지방도시의 지속가능성 평가모형 (An Assessment Model on Sustainability of Local City)

  • 홍영록;권상준;명현
    • 한국조경학회지
    • /
    • 제27권4호
    • /
    • pp.1-12
    • /
    • 1999
  • This study aims to find basic data for using the quantitative assessment of the sustainability and establishing the systematic index of the planning for local cities to consider the environmentally sound and sustainable development. The research designs to review professional responding to surveys preceded by separate questionnaires and interviews from book reviews, and suggests to make an assessment model of the sustainability for local cities. The research found consequently as follows. Firstly, the research survey items were decides totally 52, grouped 9 assessmental issues and distributed under 4 assessmental domains for the sustainability from the references of book reviews. Secondly, the research result concentrated on the followings from the professional responding to surveys. 1. A most influent factor is the distribution of animals and plants in a nature domain. The next influent factors are the ratio of mass-transportation systems, the numbers of the species of animals and plants, the acreage of conservative forestry, the numbers of reused water resources, and the usage number of water supply, orderly in the nature domain. 2. A most influent factor is the usage number of synthetic detergents in a pollution domain. The next influent factors are the volume of waste water, the number of registered vehicles, the degree of soil pollution, and the charge of development imposition, orderly in the pollution domain. 3. A most influent factor is the acreage of athletic facilities, in an urban domain. the next influent factors are the acreage of recreational facilities, the number and acreage of cultural assets, the number of cultural facilities, the acreage of landscape conservation area, the charge of cultural asset management, orderly in the urban domain. 4. A most influent factor is the number of waste disposal facilities in a participation domain. The next influent factors are the capacity of reused waste, the usage of synthetic detergents, the ratio of waste water disposal, orderly in the participation domain. 5. A most contributed influent domain to the assessment of the sustainability for local cities is the urban domain. The next influent domains are nature domain, participation domain, and pollution domain, orderly in the contribution of the assessment of the sustainability. But, the pollution domain is little relationship with the sustainability. Therefore, it is clear that the abundant greens and the improved level of culture are dominant influences on the sustainabiligy, as like improving the ratio of roadside trees, the acreage of parks, and enlarging the number of cultural facilities.

  • PDF

철도 무도상판형교의 고유진동특성에 대한 연구 (A Study on the Characteristic of Natural Frequencies of Railway Open Deck Plate Girder Bridges)

  • 오지택;최진유;김현민
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2002년도 추계학술대회 논문집(II)
    • /
    • pp.1041-1046
    • /
    • 2002
  • A railway open deck plate girder bridge without ballast should support relatively heavier vehicle loads compared with its self-weight. For such a reason, actual dynamic response of the bridge is considerably differing with normal prediction because additional masses added from vehicle to a bridge have an effect on the dynamic characteristics of the bridge. These differences affect to the estimation of a natural frequency change that adopted for one of the evaluation technique of strength decrease, and these make trouble to the analysis of a natural frequency from the field test data that measured at the bridge subjected to a running vehicle. In this study, classification of mass participation ratio for each component of open deck plate girder bridge without ballast and the comparison according to the change of vibration characteristics for the case of subjected to a running vehicle were accomplished.

  • PDF

TLCD와 TSD를 이용한 새로운 형태의 양방향 감쇠기 설계변수 (Design Parameter of a New Type Bi-directional Damper Using a Tuned Liquid Column Damper and a Tuned Sloshing Damper)

  • 민경원
    • 한국소음진동공학회논문집
    • /
    • 제19권8호
    • /
    • pp.850-856
    • /
    • 2009
  • A new type bi-directional damper using a tuned liquid column damper(TLCD) and a tuned sloshing damper(TSD) is introduced in this study. Two dampers are usually needed to reduce wind-induced responses of tall buildings since they are along and across wind ones. The proposed damper has the advantage of controlling both responses with one damper. One of objectives of this study is to derive analytical dynamics to investigate coupled effects due to TLCD and TSD. Another objective is to address the effect of coupled control force due to TLCD and TSD on the dynamic characteristic of the damper based on analytical dynamics. Shaking table test is undertaken to experimentally grasp dynamic characteristics of the damper under white noise excitation. Its dynamic characteristic is expressed by the transfer function from the shaking table acceleration to the control force generated from the damper. Finally, its design parameters are identified based on the coupled dynamics, which include the mass ratio of horizontal liquid column to total liquid for a TLCD, the participation factor of the fundamental liquid sloshing for a TSD and damping ratio for both cases.

시스템 통합(SI) 구축 사업 품질 향상을 위한 연구 (Research for improving quality of SI(System integration) development project)

  • 김석관;류갑상
    • 한국정보전자통신기술학회논문지
    • /
    • 제11권3호
    • /
    • pp.215-220
    • /
    • 2018
  • 중견/중소 IT기업의 사업 수행 기회 증대, 기회 균등과 역량 강화라는 취지로 소프트웨어(SW)산업진흥법 개정으로 공공정보화시장에 대기업 참여를 제한되었다. 이러한 환경에서의 중견/중소 SW기업들의 사업을 수행하면서 발생한 사업 수행 역량 미흡으로 공공정보화사업의 품질저하, 위험관리 미숙, 일정관리 저하 등 여러 문제점을 발생시키고 있다. 이를 해결하기 위해 본 논문은 시스템통합 사업 수행 시 품질 저하 요인을 도출하였으며, 이를 해결하기 위한 방안으로 VISUALIZATION, 엄격한 시험관리, Agile방법론의 일부 활동을 적용하여 프로젝트를 수행하는 것을 제안했다. 이러한 방안을 중견/중소 IT기업이 개발한 보건의료 IT 프로젝트에 적용한 결과 의사소통의 개선, 수치화된 진척관리 및 프로젝트의 가시성이 개선되었다. 또한, 결함 해결시간 최소화, 요구사항 커리리지 비율 개선, 불필요한 회의시간이 단축이 되어 품질 향상에 기여하였습니다.

공동주택 주호개수를 위한 거주자 참여 디자인 수법에 관한 사례연구 (A Study on the Method of Residents-Participatory Design for Apartment Housing Remodeling)

  • 이용규
    • 한국주거학회논문집
    • /
    • 제24권4호
    • /
    • pp.53-60
    • /
    • 2013
  • Apartments amount to 58.3%, the highest proportion of domestic housing types. These apartments' lifespan (approximately 27 years) are one-third of the developed countries' housing lifespan due to the property developers and mass production. It is significantly short-cycle period considering the original physical lifespan of the apartment housing are 60 years. It has caused economic loss and environmental degradation. In recent years, research and development for the long life of the apartment housing has been actively performed, but it is limited on reconstruction and new construction. Reconstruction of existing a number of high-rise apartments is difficult owing to restrictions on the floor area ratio allowing for 40 years limit of decay resistance after the completion. Improving lifespan of the building has recently begun to receive attention as an alternative to remodeling. However, These sort of remodeling techniques tend to be focused on technology developed for the physical life extension. That means developing the techniques about dwelling-unit environment for residents satisfaction are required as well as improving physical construction. The purpose of this study is to propose and verify the Participatory Design Technique which can help the residents as the active participation in the design decision-making process.

INTEGRAL EFFECT TESTS IN THE PKL FACILITY WITH INTERNATIONAL PARTICIPATION

  • Umminger, Klaus;Mull, Thomas;Brand, Bernhard
    • Nuclear Engineering and Technology
    • /
    • 제41권6호
    • /
    • pp.765-774
    • /
    • 2009
  • For over 30 years, investigations of the thermohydraulic behavior of pressurized-water reactors under accident conditions have been carried out in the PKL test facility at AREVA NP in Erlangen, Germany. The PKL facility models the entire primary side and significant parts of the secondary side of a of pressurized water reactor at a height scale of 1:1. Volumes, power ratings and mass flows are scaled with a ratio of 1:145. The experimental facility consists of four primary loops with circulation pumps and steam generators (SGs) arranged symmetrically around the reactor pressure vessel (RPV). The investigations carried out encompass a very broad spectrum from accident scenario simulations with large, medium, and small breaks, over the investigation of shutdown procedures after a wide variety of accidents, to the systematic investigation of complex thermohydraulic phenomena. The PKL tests began in the mid 1970s with the support of the German Research Ministry. Since the mid 1980s, the project has also been significantly supported by the German PWR operators. Since 2001, 25 partner organizations from 15 countries have taken part in the PKL investigations with the support and mediation of the OECD/ NEA (Nuclear Energy Agency). After an overview of PKL history and a short description of the facility, this paper focuses on the investigations carried out since the beginning of the international cooperation, and shows, by means of some examples, what insights can be derived from the tests.

Multi-point earthquake response of the Bosphorus Bridge to site-specific ground motions

  • Bas, Selcuk;Apaydin, Nurdan Memisoglu;Harmandar, Ebru;Catbas, Necati
    • Steel and Composite Structures
    • /
    • 제26권2호
    • /
    • pp.197-211
    • /
    • 2018
  • The study presents the earthquake performance of the Bosphorus Bridge under multi-point earthquake excitation considering the spatially varying site-specific earthquake motions. The elaborate FE model of the bridge is firstly established depending on the new considerations of the used FEM software specifications, such as cable-sag effect, rigid link and gap elements. The modal analysis showed that singular modes of the deck and the tower were relatively effective in the dynamic behavior of the bridge due to higher total mass participation mass ratio of 80%. The parameters and requirements to be considered in simulation process are determined to generate the spatially varying site-specific ground motions. Total number of twelve simulated ground motions are defined for the multi-support earthquake analysis (Mp-sup). In order to easily implement multi-point earthquake excitation to the bridge, the practice-oriented procedure is summarized. The results demonstrated that the Mp-sup led to high increase in sectional forces of the critical components of the bridge, especially tower base section and tensile force of the main and back stay cables. A close relationship between the dynamic response and the behavior of the bridge under the Mp-sup was also obtained. Consequently, the outcomes from this study underscored the importance of the utilization of the multi-point earthquake analysis and the necessity of considering specifically generated earthquake motions for suspension bridges.