• 제목/요약/키워드: masonry buildings

검색결과 197건 처리시간 0.023초

The investigation of seismic performance of existing RC buildings with and without infill walls

  • Dilmac, Hakan;Ulutas, Hakan;Tekeli, Hamide;Demir, Fuat
    • Computers and Concrete
    • /
    • 제22권5호
    • /
    • pp.439-447
    • /
    • 2018
  • One of the important factors is the infill walls in the change of the structural rigidity, ductility, dynamic and static characteristics of the structures. The infill walls are not generally included in numerical analysis of reinforced concrete (RC) structural system due to lack of suitable theory and the difficulty of calculating the recommended models. In seismic regions worldwide, the residential structures are generally RC buildings with infill wall. Therefore, understanding the contribution of the infill walls to seismic performance of buildings may have a vital importance. This paper investigates the effects of infill walls on seismic performance of the existing RC residential buildings by considering requirements of the Turkish Earthquake Code (TEC). Seismic performance levels of residential RC buildings with and without walls in high-hazard zones were determined according to the nonlinear procedure given in the code. Pushover curves were obtained by considering the effect of masonry infill walls on seismic performance of RC buildings. The analysis results showed that the infill walls beneficially effected to the rigidity, roof displacements and seismic performance of the building.

등가 스트럿 모델을 이용한 조적조 채움벽 골조의 내진성능평가 (Seismic Performance Evaluation of Masonry-Infilled Frame Structures using Equivalent Strut Models)

  • 박지훈;전성하;강경수
    • 한국지진공학회논문집
    • /
    • 제16권1호
    • /
    • pp.47-59
    • /
    • 2012
  • 본 연구에서는 학교건물에서 나타나는 전형적인 조적조 채움벽 골조의 내진성능을 등가 스트럿 모델을 통해 평가하였다. 순수골조모델, 중심스트럿모델 및 편심스트럿모델의 세 가지 모형화 방법을 채택하였고, 문헌상으로 얻을 수 있는 범위의 스트럿 강성과 강도를 적용하여 거동특성의 차이를 분석하였다. 역량스펙트럼에 의해 산정된 성능점에서의 변위 및 손상정도에 큰 차이가 나타났으며, 채움벽은 순수골조모델과 비교할 때 중심스트럿모델에서는 유리하게, 편심스트럿모델에서는 불리하게 작용하는 것으로 나타났다. 최종극한변위에서의 거동 또한 모형화 방법 및 재료 속성에 따라서 최대강도, 층간변위, 파괴된 부재 수 및 위치 등에 큰 차이가 나타났다.

Modeling of unreinforced brick walls under in-plane shear & compression loading

  • Kalali, Arsalan;Kabir, Mohammad Zaman
    • Structural Engineering and Mechanics
    • /
    • 제36권3호
    • /
    • pp.247-278
    • /
    • 2010
  • The study of the seismic vulnerability of masonry buildings requires structural properties of walls such as stiffness, ultimate load capacity, etc. In this article, a method is suggested for modeling the masonry walls under in-plane loading. At the outset, a set of analytical equations was established for determining the elastic properties of an equivalent homogeneous material of masonry. The results for homogenized unreinforced brick walls through detailed modeling were compared in different manners such as solid and perforated walls, in-plane and out-of-plane loading, etc, and it was found that this method provides suitable accuracy in estimation of the wall linear properties. Furthermore, comparison of the results of proposed modeling with experimental out coming indicated that this model considers the non linear properties of the wall such as failure pattern, performance curve and ultimate strength, and would be appropriate to establish a parametric study on those prone factors. The proposed model is complicated; therefore, efforts need to be made in order to overcome the convergency problems which will be included in this study. The nonlinear model is basically semi-macro but through a series of actions, it can be simplified to a macro model.

Derivation of analytical fragility curves using SDOF models of masonry structures in Erzincan (Turkey)

  • Karimzadeh, Shaghayegh;Kadas, Koray;Askan, Aysegul;Erberik, M. Altug;Yakut, Ahmet
    • Earthquakes and Structures
    • /
    • 제18권2호
    • /
    • pp.249-261
    • /
    • 2020
  • Seismic loss estimation studies require fragility curves which are usually derived using ground motion datasets. Ground motion records can be either in the form of recorded or simulated time histories compatible with regional seismicity. The main purpose of this study is to investigate the use of alternative ground motion datasets (simulated and real) on the fragility curves. Simulated dataset is prepared considering regional seismicity parameters corresponding to Erzincan using the stochastic finite-fault technique. In addition, regionally compatible records are chosen from the NGA-West2 ground motion database to form the real dataset. The paper additionally studies the effects of hazard variability and two different fragility curve derivation approaches on the generated fragility curves. As the final step for verification purposes, damage states estimated for the fragility curves derived using alternative approaches are compared with the observed damage levels from the 1992 Erzincan (Turkey) earthquake (Mw=6.6). In order to accomplish all these steps, a set of representative masonry buildings from Erzincan region are analyzed using simplified structural models. The results reveal that regionally simulated ground motions can be used alternatively in fragility analyses and damage estimation studies.

Hysteretic performance of a novel composite wall panel consisted of a light-steel frame and aerated concrete blocks

  • Wang, Xiaoping;Li, Fan;Wan, Liangdong;Li, Tao
    • Steel and Composite Structures
    • /
    • 제41권6호
    • /
    • pp.861-871
    • /
    • 2021
  • This study aims at investigating the hysteretic performance of a novel composite wall panel fabricated by infilling aerated concrete blocks into a novel light-steel frame used for low-rise residential buildings. The novel light-steel frame is consisted of two thin-wall rectangular hollow section columns and a truss-beam assembled using patented U-shape connectors. Two bare light-steel frames and two composite wall panels have been tested to failure under horizontal cyclic loading. Hysteretic curves, lateral resistance and stiffness of four specimens have been investigated and analyzed. Based on the testing results, it is found that the masonry infill can significantly increase the lateral resistance and stiffness of the novel light-steel frame, about 2.3~3 and 21.2~31.5 times, respectively. Failure mode of the light-steel frame is local yielding of the column. For the composite wall panel, firstly, masonry infill is crushed, subsequently, local yielding may occur at the column if loading continues. Hysteretic curve of the composite wall panel obtained is not plump, implying a poor energy dissipation capacity. However, the light-steel frame of the composite wall panel can dissipate more energy after the masonry infill is crushed. Therefore, the composite wall panel has a much higher energy dissipation capacity compared to the bare light-steel frame.

초고층 주상복합 건물의 하자 발생 유형 및 분석 연구 (The analysis of defects types and patterns in high-rise residential buildings)

  • 서장우;강경인
    • 한국건축시공학회지
    • /
    • 제9권2호
    • /
    • pp.93-101
    • /
    • 2009
  • Recently, public interest in housing defects, such as construction errors, occupiers' complaints, faults in production, and so on, is increasing. In addition, the construction requirements of high-rise residential buildings have increased, due to the higher prices of urban areas, especially in metropolitan areas. While previous research has focused on the defects occurring in apartment housing complexes, research has not been carried out on the defects occurring in high-rise residential buildings. In this paper, the defects patterns and characteristics of high-rise residential buildings are examined and analyzed and a defect management plan is then suggested. In order to do this, we collected the defects data of high-rise residential buildings recorded by 2,299 of 2,327 occupants. The defect occurrence rate (DOR) in the residential area is 98.8%. The frequency rate of defect occurrence over the total defect occurrence since building completion is 63.28% during the first year, 24.63% (second year), 6.88% (third year), 2.27% (fourth year), and 2.53% (fifth year). The result of correlation analysis between work types showed that there is a relationship between the built-in furniture and electronics (F&E) and painting works, and the F&E and masonry works, such as marble finishing. We expect that this research will assist in the efforts to decrease the number of defects in high-rise buildings.

Seismic retrofitting of Fragavilla Monastery

  • Karantoni, Fillitsa V.
    • Earthquakes and Structures
    • /
    • 제5권2호
    • /
    • pp.207-223
    • /
    • 2013
  • Practical seismic assessment and design of retrofit for the multitude of small ecclesiastical monuments that abound in the Balkans is the subject of this work. Application of the proposed procedures and methodologies are illustrated in an example case study, a small byzantine church located in Western Greece, which is the region with the highest seismicity in Europe. The church, known as the Fragavilla Monastery, had remained almost undamaged for 800 years, until 1993 when the Pyrgos earthquake caused critical damage mainly in the vaults. Linear elastic analysis to the recorded ground motion, capped by a biaxial failure criterion reproduced the developed damage. The same modelling and analysis procedure was subsequently used for assessment of the intended retrofitting measures. Proposed retrofitting measures included mitigation of the undesirable implications of past interventions along with a combination of strengthening schemes with externally bonded AFRPs strategically placed in the structure. The effectiveness of the proposed solutions is gauged by successful reduction of stress intensity in the critical regions and mitigation of stress localization throughout the structure.

10층 조적채움 R.C. 골조의 비선형 거동에 대한 해석과 실험의 상관성 연구 (Corelation of Experimental and Analytical Response of a 1:12 Scale 10-Story Masonry-Infilled R.C. Frame)

  • 이한선;김정우;김상호
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 1999년도 학회창립 10주년 기념 1999년도 가을 학술발표회 논문집
    • /
    • pp.487-490
    • /
    • 1999
  • Nowadays, the pushover analysis technique is becoming a very useful tool for the prediction of inelastic behavior of structures in the seismic evaluation of existing buildings in the world. However, the reliability of this analysis method has not been fully checked by the test results. The objective of this study is to verify the correlation between the analytical and experimental response of a high-rise masonry infilled reinforced concrete frame using DRAIN-2DX program and the test results performed previously. This study concludes that the strength and stiffness of members can be predicted with quite high reliability while the ductility capacity of members can not be described reasonably.

  • PDF

Long run ambient noise recording for a masonry medieval tower

  • Casciati, S.;Tento, A.;Marcellini, A.;Daminelli, R.
    • Smart Structures and Systems
    • /
    • 제14권3호
    • /
    • pp.367-376
    • /
    • 2014
  • Ambient vibration techniques are nowadays a very popular tool to assess dynamic properties of buildings. Due to its non destructive character, this method is particularly valuable, especially for health monitoring of historical monuments. The present ambient vibration experiment consists on the evaluation of vibration modes of a Medieval tower. Situated in Soncino (close to Cremona, in the Northern Italian region named Lombardia), the tower of 41.5 meters height has been monitored by seismometers located at different points inside the structure. Spectral ratios of the recorded ambient vibrations clearly identify a fundamental mode at about 1 Hz, with a slight difference in the two horizontal components. A second mode is also evidenced at approx 4-5 Hz, with a moderate degree of uncertainty. The records of a ML 4.4 earthquake, occurred during the monitoring period, confirm the information obtained by microtremor analysis. Daily variations of both 1st and 2nd mode were detected: these variations, of an amount up to 2%, seem to be well related with the temperature.

비보강 조적조 건물의 등가 정적 해석에 관한 연구 (A Study on the Equivalent Static Analysis of Unreinforced Masonry Buildings)

  • 정상훈;김관중;김희철
    • 한국지진공학회논문집
    • /
    • 제4권3호
    • /
    • pp.1-10
    • /
    • 2000
  • 우리 나라의 주거 건물의 많은 부분을 차지하는 조적조 건물은 저층이므로 내진 설계에 대한 지침이 마련되어 있지 않다. 그러나 조적조 건물의 경우 저층이라 하더라도 구조특성상 수평하중에 대한 저항능력이 매우 약하므로 내진 설계에 대한 기준이 요구된다. 일반적으로 내진설계 시 동적 해석을 수행하면 많은 시간이 소모되므로 실무자들에게 등가정적해석법을 제시하여 내진설계 시 편의를 제공하고 있다. 그러나 저층 조적조 건물은 일반적인 건물과는 거동 특성이 다르므로 저층 조적조 건물에 적용할 수 있는 해석법을 제시하고자 한다. 본 논문에서는 개구부의 비율에 따른 조적벽의 연성도, 강도 및 고유주기를 구하여 반응수정계수와 고유주기를 비교하여 우리 나라의 조적조 건물에 적합한 반응수정계수와 고유주기 산정식을 제안하였다.

  • PDF