• Title/Summary/Keyword: masonry buildings

Search Result 199, Processing Time 0.02 seconds

Masonry building behaviors during the February 6-12, 2017 Ayvacik-Çanakkale Earthquakes

  • Ural, Ali
    • Earthquakes and Structures
    • /
    • v.17 no.4
    • /
    • pp.355-363
    • /
    • 2019
  • Masonry structures in the rural areas of Turkey often damaged due to moderate and big earthquakes. After every earthquake many scientists made field investigations on the earthquake performance of these structures and gave many useful information on construction techniques. However, the newly constructed masonry buildings are still not suitable for the suggested techniques, and they are still in danger against future earthquakes. Five moderate earthquakes of moment magnitude Mw 5.3, 5.3, 5.2, 5.0, and 5.3 struck the Ayvacik-Çanakkale District of Turkey between 6 and 12 February, 2017. More than a thousand of aftershocks were occurred and most of the masonry buildings in the villages nearby main shock epicenter were affected. The author went to the earthquake field and investigated the earthquake performances of masonry structures. This paper presents the recorded acceleration data, acceleration response spectra, and the seismological aspects of these earthquakes. Besides, case studies of damaged stone masonry buildings, and failure mechanisms are discussed with illustrated photos which were taken during the field investigations. It is concluded that the damaged masonry buildings were not designed and constructed properly in accordance with the Turkish building codes or similar specifications.

Optimization of the seismic performance of masonry infilled R/C buildings at the stage of design using artificial neural networks

  • Kostinakis, Konstantinos G.;Morfidis, Konstantinos E.
    • Structural Engineering and Mechanics
    • /
    • v.75 no.3
    • /
    • pp.295-309
    • /
    • 2020
  • The construction of Reinforced Concrete (R/C) buildings with unreinforced masonry infills is part of the traditional building practice in many countries with regions of high seismicity throughout the world. When these buildings are subjected to seismic motions the presence of masonry infills and especially their configuration can highly influence the seismic damage state. The capability to avoid configurations of masonry infills prone to seismic damage at the stage of initial architectural concept would be significantly definitive in the context of Performance-Based Earthquake Engineering. Along these lines, the present paper investigates the potential of instant prediction of the damage response of R/C buildings with various configurations of masonry infills utilizing Artificial Neural Networks (ANNs). To this end, Multilayer Feedforward Perceptron networks are utilized and the problem is formulated as pattern recognition problem. The ANNs' training data-set is created by means of Nonlinear Time History Analyses of 5 R/C buildings with a large number of different masonry infills' distributions, which are subjected to 65 earthquakes. The structural damage is expressed in terms of the Maximum Interstorey Drift Ratio. The most significant conclusion which is extracted is that the ANNs can reliably estimate the influence of masonry infills' configurations on the seismic damage level of R/C buildings incorporating their optimum design.

Equivalent frame model and shell element for modeling of in-plane behavior of Unreinforced Brick Masonry buildings

  • Kheirollahi, Mohammad
    • Structural Engineering and Mechanics
    • /
    • v.46 no.2
    • /
    • pp.213-229
    • /
    • 2013
  • Although performance based assessment procedures are mainly developed for reinforced concrete and steel buildings, URM (Unreinforced Masonry) buildings occupy significant portion of buildings in earthquake prone areas of the world as well as in IRAN. Variability of material properties, non-engineered nature of the construction and difficulties in structural analysis of masonry walls make analysis of URM buildings challenging. Despite sophisticated finite element models satisfy the modeling requirements, extensive experimental data for definition of material behavior and high computational resources are needed. Recently, nonlinear equivalent frame models which are developed assigning lumped plastic hinges to isotropic and homogenous equivalent frame elements are used for nonlinear modeling of URM buildings. The equivalent frame models are not novel for the analysis of masonry structures, but the actual potentialities have not yet been completely studied, particularly for non-linear applications. In the present paper an effective tool for the non-linear static analysis of 2D masonry walls is presented. The work presented in this study is about performance assessment of unreinforced brick masonry buildings through nonlinear equivalent frame modeling technique. Reliability of the proposed models is tested with a reversed cyclic experiment conducted on a full scale, two-story URM building at the University of Pavia. The pushover curves were found to provide good agreement with the experimental backbone curves. Furthermore, the results of analysis show that EFM (Equivalent Frame Model) with Dolce RO (rigid offset zone) and shell element have good agreement with finite element software and experimental results.

Earthquake performance assessment of low and mid-rise buildings: Emphasis on URM buildings in Albania

  • Bilgin, Huseyin;Huta, Ergys
    • Earthquakes and Structures
    • /
    • v.14 no.6
    • /
    • pp.599-614
    • /
    • 2018
  • This study focuses on the earthquake performance of two URM buildings having typical architectural configurations common for residential use constructed per pre-modern code in Albania. Both buildings are unreinforced clay brick masonry structures constructed in 1960 and 1984, respectively. The first building is a three-storey unreinforced one with masonry walls. The second one is confined masonry rising on five floors. Mechanical characteristics of masonry walls were determined based on experimental tests conducted according to ASTM C67-09 regulations. A global numerical model of the buildings was built, and masonry material was simulated as nonlinear. Pushover analyses are carried out to obtain capacity curves. Displacement demands were calculated according to Eurocode 8 and FEMA440 guidelines. Causes of building failures in recent earthquakes were examined using the results of this study. The results of the study showed that the URM building displays higher displacement and shear force demands that can be directly related to damage or collapse. On the other hand, the confined one exhibits relatively higher seismic resistance by indicating moderate damage. Moreover, effects of demand estimation approaches on performance assessment of URM buildings were compared. Deficiencies and possible solutions to improve the capacity of such buildings were discussed.

Seismic vulnerability assessment of confined masonry wall buildings

  • Ranjbaran, Fariman;Hosseini, Mahmood
    • Earthquakes and Structures
    • /
    • v.7 no.2
    • /
    • pp.201-216
    • /
    • 2014
  • In this paper the vulnerability of the confined masonry buildings is evaluated analytically. The proposed approach includes the nonlinear dynamic analysis of the two-story confined masonry buildings with common plan as a reference structure. In this approach the damage level is calculated based on the probability of exceedance of loss vs a specified ground motion in the form of fragility curves. The fragility curves of confined masonry wall buildings are presented in two levels of limit states corresponding to elastic and maximum strength versus PGA based on analytical method. In this regard the randomness of parameters indicating the characteristics of the building structure as well as ground motion is considered as likely uncertainties. In order to develop the analytical fragility curves the proposed analytical models of confined masonry walls in a previous investigation of the authors, are used to specify the damage indices and responses of the structure. In order to obtain damage indices a series of pushover analyses are performed, and to identify the seismic demand a series of nonlinear dynamic analysis are conducted. Finally by considering various mechanical and geometric parameters of masonry walls and numerous accelerograms, the fragility curves with assuming a log normal distribution of data are derived based on capacity and demand of building structures in a probabilistic approach.

Seismic Capacity Strengthened by GFS of Masonry Buildings with Earthquake Damage (지진피해를 입은 조적조 건축물의 유리섬유보강에 따른 내진성능)

  • Kwon, Ki-Hyuk;Choi, Sung-Mo;Lee, Soo-Cheul;Cho, Sang-Min
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.8 no.1
    • /
    • pp.231-237
    • /
    • 2004
  • Most of the masonry buildings have many structural defects under an earthquake load due to the small tensile force and ductility. In the foreign countries there are many the reinforcing methods of masonry buildings, but the glass fiber sheet reinforcements must be used due to various conditions in Korea. The purpose of this paper is to estimate the seismic capacity of masonry buildings damaged by earthquake and reinforced by Glass Fiber Sheet. On the basis of test results, the maximum base shear force and deformation of the masonry building with GFS were remarkably increased. From the comparison by existing strength equations and test data, the new strength equation of reinforced masonry buildings with GFS was developed.

Strengthening techniques for masonry structures of cultural heritage according to recent Croatian provisions

  • Hadzima-Nyarko, Marijana;Ademovic, Naida;Pavic, Gordana;Sipos, Tanja Kalman
    • Earthquakes and Structures
    • /
    • v.15 no.5
    • /
    • pp.473-485
    • /
    • 2018
  • The buildings of architectural and cultural heritage are mostly built with stone or brick wall elements, which are connected using limestone or limestone cement mortar, without a full knowledge of the mechanical properties of masonry structures. The compatibility of heritage masonry buildings with valid technical specifications and the rules for earthquake resistance implies the need for construction work such as repairs, strengthening or reconstruction. By strengthening the masonry buildings, ductility and bearing capacity are increased to a level, which, in the case of the earthquake design, allows for some damage to happen, however the structure retains sufficient usability and bearing capacity without the possibility of collapse. Comparison between traditional and modern techniques for seismic strengthening of masonry buildings is given according to their effects, benefits and disadvantages. Recent Croatian provisions provided for heritage buildings enabling deviation of technical specifications are discussed.

Seismic fragility of regular masonry buildings for in-plane and out-of-plane failure

  • Karantoni, Fillitsa;Tsionis, Georgios;Lyrantzaki, Foteini;Fardis, Michael N.
    • Earthquakes and Structures
    • /
    • v.6 no.6
    • /
    • pp.689-713
    • /
    • 2014
  • The seismic vulnerability of stone masonry buildings is studied on the basis of their fragility curves. In order to account for out-of-plane failure modes, normally disregarded in past studies, linear static Finite Element analysis in 3D of prototype regular buildings is performed using a nonlinear biaxial failure criterion for masonry. More than 1100 analyses are carried out, so as to cover the practical range of the most important parameters, namely the number of storeys, percentage of side length in exterior walls taken up by openings, wall thickness, plan dimensions and number of interior walls, type of floor and pier height-to-length ratio. Results are presented in the form of damage and fragility curves. The fragility curves correspond well to the damage observed in masonry buildings after strong earthquakes and are in good agreement with other fragility curves in the literature. They confirm what is already known, namely that buildings with stiff floors or higher percentage of load-bearing walls are less vulnerable, and that large openings, taller storeys, larger number of storeys, higher wall slenderness and higher ratio of clear height to horizontal length of walls increase the vulnerability, but show also by how much.

Earthquake Damae Ratio Estimation and Seismic Capacity Evaulation of Existing unreinforced masonry building in Korea (한국 조적조 건물의 내진성능 및 지진피해율 평가)

  • Kang, Dae-Eon;Yang, Won-Jik;Yi, Waon-Ho
    • Proceedings of the Earthquake Engineering Society of Korea Conference
    • /
    • 2005.03a
    • /
    • pp.258-265
    • /
    • 2005
  • The purpose of this study is to provide basic information for unreinforced masonry building in Korea by application of the proposed seismic evaluation method. In this study, seismic capacities of 50 existing unreinforced masonry buildings are evaluated based on the proposed method. Also, relationships of seismic capacities between Korean earthquake damage ratios of Korean unreinforced masonry buildings are estimated. Results of this study were as follows; 1)Seismic retrofit was needed $4{\sim}48%$ in Korean unreinforced masonry buildings. 2)Korean unreinforced masonry buildings were expected to have severe damage under the earthquake intensity level experienced in Japan.

  • PDF

Seismic spectral acceleration assessment of masonry in-filled reinforced concrete buildings by a coefficient-based method

  • Su, R.K.L.;Lee, C.L.;Wang, Y.P.
    • Structural Engineering and Mechanics
    • /
    • v.41 no.4
    • /
    • pp.479-494
    • /
    • 2012
  • This study explores a coefficient-based seismic capacity assessment method with a special emphasis on low-rise masonry in-filled (MI) reinforced concrete (RC) buildings subjected to earthquake motion. The coefficient-based method without requiring any complicated finite element analysis is a simplified procedure to assess the maximum spectral acceleration capacity of buildings. This paper first compares the fundamental periods of MI RC structures obtained, respectively, from experimental period data and empirical period-height formulas. The coefficient-based method for low-rise masonry buildings is then calibrated by the published experimental results obtained from shaking table tests. The comparison of the experimental and estimated results indicates that the simplified coefficient-based method can provide good approximations of the maximum spectral accelerations at peak loads of the low-rise masonry reinforced concrete buildings if a proper set of drift factors and initial fundamental vibration periods of structures are used.