• 제목/요약/키워드: marine plant

검색결과 870건 처리시간 0.025초

경남 온산면 일대의 해조류에 관한 연구 2. 계절적 변화 (On the Marine Algae in Onsan Area, East Coast of Korea 2. Seasonal Variation)

  • 김영환
    • Journal of Plant Biology
    • /
    • 제23권2호
    • /
    • pp.61-67
    • /
    • 1980
  • As a part of the environmental base line survey of the Onsan Industrial Base, Korea, marine algal communities were investigated using the quadrat method in Onsan-myon on the east coast of Korea from March to December of 1978. It was learned that the representative dominat species along the coast in the Onsan area throughout the year are Ulva pertusa, Pachymeniopsis elliptica, and Sargassum thunbergii. Both the number of algal species occurring in the quadrat (50$\times$50cm) and the total coverage were higher in March and September than in June and December. A total of 94 species (1 blue-green, 16 green, 25 brown, and 52 red algae) of marine algae was identified in this study.

  • PDF

해양플랜트 인력양성을 위한 직무능력향상 매트릭스 개발에 관한 연구 -해기사의 직업전환을 중심- (A Study on Development of Gap Competency Matrix for Offshore Workforce -Focusing on the Job Transportation for Seafarers-)

  • 이진우;이창희
    • 수산해양교육연구
    • /
    • 제28권2호
    • /
    • pp.407-416
    • /
    • 2016
  • The offshore plant industry has basically functioned with a rigid teamwork culture and many operations are managed by ship's crew, shifts and affiliates together. The marine sector of offshore plant has much similarity with ship's environment. So a person who had experienced on board will have advantages to work for offshore industry. But in spite of all that, only a few korean seafarers are able to join in the offshore industry due to lack of information about the offshore environment. This study analyze the employee's wage structure, nature of employment contract, requirements of job qualifications. Therefore, this study will assist for seafarers to set up how to get their work and also suggest to develop relevant offshore training courses by researching the gap competency matrix.

해양 소수력발전용 유도발전기의 최적 무효전력 산정방식에 관한 연구 (A Study on the Optimal Reactive Power Calculation Method of Induction Generator for Marine Small Hydraulic Power)

  • 이원재;오용택
    • 조명전기설비학회논문지
    • /
    • 제27권9호
    • /
    • pp.100-107
    • /
    • 2013
  • Since the West Sea experiences a big difference in tides, the output power of the small marine hydroelectric power plant varies with the tide. When an induction generator is used here for small hydroelectric power, the reactive power capacitor should be installed at the generator main bus to compensate for the changes in power. As such, the sizing method for the power compensation of the induction generator is reviewed and an optimal method for compensation is suggested. The self-excitation minimum capacitor capacity method, which prevents high voltages, and the power factor automatic control method, which retains a power factor of greater than 90% are reviewed. The compensation effect of reactive power is confirmed through a case study.

Purification and Identification of a Novel Antifungal Protein Secreted by Penicillium citrinum from the Southwest Indian Ocean

  • Wen, Chao;Guo, Wenbin;Chen, Xinhua
    • Journal of Microbiology and Biotechnology
    • /
    • 제24권10호
    • /
    • pp.1337-1345
    • /
    • 2014
  • A novel antifungal protein produced by the fungal strain Penicillium citrinum W1, which was isolated from a Southwest Indian Ocean sediment sample, was purified and characterized. The culture supernatant of P. citrinum W1 inhibited the mycelial growth of some plant pathogenic fungi. After saturation of P. citrinum W1 culture supernatants with ammonium sulfate and ion-exchange chromatography, an antifungal protein (PcPAF) was purified. The N-terminal amino acid sequence analysis showed that PcPAF might be an unknown antifungal protein. PcPAF displayed antifungal activity against Trichoderma viride, Fusarium oxysporum, Paecilomyces variotii, and Alternaria longipes at minimum inhibitory concentrations of 1.52, 6.08, 3.04, and $6.08{\mu}g/disc$, respectively. PcPAF possessed high thermostability and had a certain extent of protease and metal ion resistance. The results suggested that PcPAF may represent a novel antifungal protein with potential application in controlling plant pathogenic fungal infection.

파랑 중 해상 크레인의 하강 작업 수치 시뮬레이션 (Lowering Simulation using Floating Crane in Waves)

  • 남보우;홍사영;김병완;이동엽
    • 한국해양공학회지
    • /
    • 제26권1호
    • /
    • pp.17-26
    • /
    • 2012
  • A coupled analysis of a floating crane barge with a crane wire and hanging structure is carried out in thetime domain. The motion analysis of the crane barge is based on the floating multi-body dynamics, and thecrane wire is modeled as a simple spring tension. The hanging structure is assumed to be a rigid body with 3 degree-of-freedom translational motion. In this study, numerical simulations were conducted at three different stages. First, the developed code was validated by comparing the time-domain motion response of a crane barge with the frequency-domain results. Then, a coupled analysis of a crane barge and simple structure hanging by the crane wire was performed using the present scheme. The motion response and wire tension from the present calculations are compared with the results of OrcaFlex. The agreement between the two sets of results isfairly good. Last, lowering simulations in regular and irregular waves were conducted considering buoyancy changes in the hanging structure. The effects of the wave conditions, structure's weight, wire length, and lowering speed on the wire tension are considered.

육상용 중속 디젤엔진 발전기세트의 진동 특성 및 저감 (Vibration characteristics and reduction of Diesel Power Plant(DPP))

  • 김원현;정건화;이수목;류영석
    • 한국마린엔지니어링학회:학술대회논문집
    • /
    • 한국마린엔지니어링학회 2006년도 전기학술대회논문집
    • /
    • pp.39-40
    • /
    • 2006
  • Diesel power plant(DPP) with the medium speed diesel engine is operated under the very severe condition in aspect of load and operating time as compared with the marine diesel generator set. So, minimized vibration level have to be insured for the more stable operation of engine and generator. The vibration of generator set mainly comes from the resonance between the rigid modes by resilient mount or distortion modes by structural stiffness and the excitation forces of engine. Then, avoidance of resonance with structural modification is generally well known. In this paper, the first order vibration in non-resonance range and local vibration modes were investigated by impact test, response/ODS(operational deflection shape) measurement and 3D finite element analysis for the additional reduction of vibration. The proposed countermeasures were actually applied and their final effects were verified through the in-situ measurement.

  • PDF

Electrical system design in FLNG offshore unit

  • Kim, Jong-Su;Kim, Deok-Ki
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제39권10호
    • /
    • pp.1037-1043
    • /
    • 2015
  • In recent years, Floating Liquefied Natural Gas (FLNG) Unit have attracted considerable attention. Generally, liquefied natural gas (LNG) units are produced in onshore liquefaction terminals from gas supplied from onshore gas fields or large-scale offshore gas fields near the coast. However, the development of these gas fields has approached saturation. Large-scale offshore gas fields far from the coast, as well as undeveloped medium- and small-scale offshore gas fields, have recently attracted attention. Among several proposed concepts, the floating LNG plant in the form of the FLNG system was chosen for further evaluation and development, considering worldwide receiving infrastructure. The design of a 2.5 million tonne per annum FLNG unit has been completed with a capacity corresponding to that of modern onshore liquefaction plants. Various simulation tests were performed to evaluate the performance of the electrical power plant, focusing on the efficiency of the electrical system to secure the aspects of plant safety. This design study analyzes the electrical system for the FLNG unit to improve the safety of operation and maintenance in the field.

부하 시험 발전기 전력회수에 관한 연구 (A study on the electric power recovery in generator load test)

  • 이명호
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제38권4호
    • /
    • pp.403-408
    • /
    • 2014
  • 조선소에서 건조하고 있는 선박, 해양플랜트에 설치된 발전기의 부하 성능 시험 시 생산되는 막대한 양의 전력은 컨테이너 형태로 제작된 로드뱅크를 통해 전량 열로 낭비된다. 따라서 본 연구에서는 선박 건조 시 발전기 부하시험으로 낭비되는 전력량을 대형 조선소를 대상으로 정량적으로 조사하였으며, 소형발전기에서 생산된 전력을 한전계통에 연계하여 회수하는 실험실의 실험결과를 바탕으로 조선소에서 발전기 부하시험 시 생산되는 전력을 한전계통에 연결할 경우 회수 가능한 전력량을 연구 분석하였다.

Utilization of alternative marine fuels for gas turbine power plant onboard ships

  • El Gohary, M. Morsy;Seddiek, Ibrahim Sadek
    • International Journal of Naval Architecture and Ocean Engineering
    • /
    • 제5권1호
    • /
    • pp.21-32
    • /
    • 2013
  • Marine transportation industry is undergoing a number of problems. Some of these problems are associated with conventional marine fuel-oils. Many researchers have showed that fuel-oil is considered as the main component that causes both environmental and economic problems, especially with the continuous rising of fuel cost. This paper investigates the capability of using natural gas and hydrogen as alternative fuel instead of diesel oil for marine gas turbine, the effect of the alternative fuel on gas turbine thermodynamic performance and the employed mathematical model. The results showed that since the natural gas is categorized as hydrocarbon fuel, the thermodynamic performance of the gas turbine cycle using the natural gas was found to be close to the diesel case performance. The gas turbine thermal efficiency was found to be 1% less in the case of hydrogen compared to the original case of diesel.

태안화력발전소 주변 암반조간대에 서식하는 대형저서동물의 종조성 및 군집구조에 미치는 온배수의 영향 (Thermal Discharge Effects on the Species Composition and Community Structure of Macrobenthos in Rocky Intertidal Zone Around the Taean Thermoelectric Power Plant, Korea)

  • 정윤환;김형준;박흥식
    • Ocean and Polar Research
    • /
    • 제40권2호
    • /
    • pp.59-67
    • /
    • 2018
  • This study was conducted to understand the distribution and changes of macrobenthos on rocky intertidal areas around Taean thermoelectric power plant, Also, the purpose of this study was to produce a base-line data on the changes in water temperature due to the operation of the power plant and to understand its thermal impact on the macrobenthic community on intertidal rocky bottoms. A field survey was seasonally conducted at 3 rocky intertidal sites around the Taean thermal power plant. There was no seasonal difference in the community parameters such as number of species, mean density, biomass and species diversity during the study period. The major dominant species were Chthamalus challenger, Littorina brevicula, Crassostrea gigas. In comparison with previous study, thermal discharge in the study area did not significantly affect the distribution of dominant species. The structure of the macrobenthic community revealed that there were showed 3 different faunal groups depending on the difference in the mean density of major dominant species. The result of SIMPER analyses to determine which species were the main contributors to the differences between each community, C. challenger, Lottia spp. And Mytilus galloprovincialis, etc., revealed that there was showed a significant difference between each group. The abundance of M. galloprovincialis, showed a significant difference between faunal groups.