• Title/Summary/Keyword: marginal model

Search Result 596, Processing Time 0.025 seconds

Computational Procedure for Sea Subface Topography of East Asian Marginal Seas using Geosat Altimeter Data (Geosat 고도계자료를 이용한 동아시아해역의 해면변위 산정법)

  • 최병호;고진석
    • Journal of the Korean Society of Surveying, Geodesy, Photogrammetry and Cartography
    • /
    • v.12 no.1
    • /
    • pp.107-118
    • /
    • 1994
  • As satellite altimetry is being progressed to apply with heigher precision to maginal seas, it was necessary to improve correction procedures for tidal signals in altimetry with more accurate tidal model than well-known model of Schwiderski for studying marginal sea dynamics. As a first step, tidal regime of semidiurnal tides$(M_2,\;S_2,\;N_2,\;K_2)$ and diurnal tides$(K_1,\;O_1,\;P_1,\;Q_1)$ were computed with a finer details of formulation of tidal model over the East Asian Marginal Seas covering the Okhotsk Sea and South China Sea and part of Northwest Pacific Ocean with mesh resolutions of 1/6$^{\circ}$. Subsequently the computed sets of harmonic constants from the model were used to remove the tide in selected Sea Surface Heights from Geosat in the modelled region. Preliminary correction procedure suggested in the present study may be extensively used for obtaining Sea Surface Topography over the East Asian Marginal Seas, especially for the region where Schwiderski's harmonic constants are not available.

  • PDF

Study on the stress distribution around two types of implants with an internal connection by finite element analysis (임프란트와 지대주 간 내측 연결을 갖는 2종의 임프란트에서 저작압이 임프란트 주위골 내응력 분포에 미치는 영향에 관한 연구)

  • Yoo, Mi-Kyung;Lim, Sung-Bin;Chung, Chin-Hyung;Hong, Ki-Seok
    • Journal of Periodontal and Implant Science
    • /
    • v.36 no.2
    • /
    • pp.473-488
    • /
    • 2006
  • Adequate bone quality and stress distribution to the bone are of decisive importance for implant success. Even though the success rates of dental implants have been high, implant failures do occur. Overloading has been identified as a primary factor behind dental implant failure. The purpose of this study was to theoretically investigate the effect of two types of implants on the stress distribution in poor bone quality. Employing the finite element method, the study modeled a 4.1 mm diameter, 12.0 mm length implant placed in cortical or spongeous bone. A static loading of lOON was applied at the occlusal surface at 0, 30 degrees angle to the vertical axis of the implant. von Mises stresses concentrations in the supporting bone were analyzed with finite element analysis program. The results were as follows; 1. The stresses at the marginal bone were higher under buccal oblique load(30 degrees off of the long axis) than under vertical load. 2. Under buccal oblique load, the stresses were higher at the lingual marginal bone than at the buccal marginal bone, and the differences were almost the same. 3, Under vertical and oblique load, the stress was the highest at the marginal bone and lowest at the bone around apical portions of implant in cortical bone. 4, Under vertical load, Model 1 showed more effective stress distribution than Model 2 irrespective of bone types. On the other hand, Model 2 showed lower stress concentration than Model 1 under buccal oblique load.

Evaluation of marginal and internal gap under model-free monolithic zirconia restoration fabricated by digital intraoral scanner (디지털 구강스캐너로 모형 없이 제작한 전부지르코니아 수복물의 변연 및 내면 적합도 평가)

  • Lee, Jong-Won;Park, Ji-Man
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.54 no.3
    • /
    • pp.210-217
    • /
    • 2016
  • Purpose: The aim of this study was to evaluate the marginal and internal adaptation of monolithic zirconia restoration made without physical model by digital intraoral scanner. Materials and methods: A prospective clinical trial was performed on 11 restorations as a pilot study. The monolithic zirconia restorations were fabricated after digital intraoral impression taking by intraoral scanner (TRIOS, 3shape, Copenhagen, Denmark), computer-aided designing, and milling manufacturing process. Completed zirconia crowns were tried in the patients' mouth and a replica technique was used to acquire the crown-abutment replica. The absolute marginal discrepancy, marginal gap, and internal gap of axial, line angle, and occlusal part were measured after sectioning the replica in the mesiodistal and buccolingual direction. Statistical analysis was performed using Kruskal-Wallis and Mann-Whitney U test (${\alpha}=.05$). Results: From the adaptation analysis by replica, the statistically significant difference was not found between mesiodistal and buccolingual sections (P>.05), but there was significant difference among the measurement location (P<.01). The amount of absolute marginal discrepancy was larger than those of marginal gap and internal gap (P<.01). Conclusion: Within the limitations of this study, the adaptation accuracy of model-free monolithic zirconia restoration fabricated by intraoral scanner exhibited clinically acceptable result. However, the margin of zirconia crown showed tendency of overcontour and cautious clinical application and follow up is necessary.

On an Optimal Bayesian Variable Selection Method for Generalized Logit Model

  • Kim, Hea-Jung;Lee, Ae Kuoung
    • Communications for Statistical Applications and Methods
    • /
    • v.7 no.2
    • /
    • pp.617-631
    • /
    • 2000
  • This paper is concerned with suggesting a Bayesian method for variable selection in generalized logit model. It is based on Laplace-Metropolis algorithm intended to propose a simple method for estimating the marginal likelihood of the model. The algorithm then leads to a criterion for the selection of variables. The criterion is to find a subset of variables that maximizes the marginal likelihood of the model and it is seen to be a Bayes rule in a sense that it minimizes the risk of the variable selection under 0-1 loss function. Based upon two examples, the suggested method is illustrated and compared with existing frequentist methods.

  • PDF

A Note on Performance of Conditional Akaike Information Criteria in Linear Mixed Models

  • Lee, Yonghee
    • Communications for Statistical Applications and Methods
    • /
    • v.22 no.5
    • /
    • pp.507-518
    • /
    • 2015
  • It is not easy to select a linear mixed model since the main interest for model building could be different and the number of parameters in the model could not be clearly defined. In this paper, performance of conditional Akaike Information Criteria and its bias-corrected version are compared with marginal Bayesian and Akaike Information Criteria through a simulation study. The results from the simulation study indicate that bias-corrected conditional Akaike Information Criteria shows promising performance when candidate models exclude large models containing the true model, but bias-corrected one prefers over-parametrized models more intensively when a set of candidate models increases. Marginal Bayesian and Akaike Information Criteria also have some difficulty to select the true model when the design for random effects is nested.

Evaluation of marginal fit of 2 CAD-CAM anatomic contour zirconia crown systems and lithium disilicate glass-ceramic crown

  • Ji, Min-Kyung;Park, Ji-Hee;Park, Sang-Won;Yun, Kwi-Dug;Oh, Gye-Jeong;Lim, Hyun-Pil
    • The Journal of Advanced Prosthodontics
    • /
    • v.7 no.4
    • /
    • pp.271-277
    • /
    • 2015
  • PURPOSE. This study was to evaluate the marginal fit of two CAD-CAM anatomic contour zirconia crown systems compared to lithium disilicate glass-ceramic crowns. MATERIALS AND METHODS. Shoulder and deep chamfer margin were formed on each acrylic resin tooth model of a maxillary first premolar. Two CAD-CAM systems (Prettau$^{(R)}$Zirconia and ZENOSTAR$^{(R)}$ZR translucent) and lithium disilicate glass ceramic (IPS e.max$^{(R)}$press) crowns were made (n=16). Each crown was bonded to stone dies with resin cement (Rely X Unicem). Marginal gap and absolute marginal discrepancy of crowns were measured using a light microscope equipped with a digital camera (Leica DFC295) magnified by a factor of 100. Two-way analysis of variance (ANOVA) and post-hoc Tukey's HSD test were conducted to analyze the significance of crown marginal fit regarding the finish line configuration and the fabrication system. RESULTS. The mean marginal gap of lithium disilicate glass ceramic crowns (IPS e.max$^{(R)}$press) was significantly lower than that of the CAD-CAM anatomic contour zirconia crown system (Prettau$^{(R)}$Zirconia) (P<.05). Both fabrication systems and finish line configurations significantly influenced the absolute marginal discrepancy (P<.05). CONCLUSION. The lithium disilicate glass ceramic crown (IPS e.max$^{(R)}$press) had significantly smaller marginal gap than the CAD-CAM anatomic contour zirconia crown system (Prettau$^{(R)}$Zirconia). In terms of absolute marginal discrepancy, the CAD-CAM anatomic contour zirconia crown system (ZENOSTAR$^{(R)}$ZR translucent) had under-extended margin, whereas the CAD-CAM anatomic contour zirconia crown system (Prettau$^{(R)}$Zirconia) and lithium disilicate glass ceramic crowns (IPS e.max$^{(R)}$press) had overextended margins.

Modelling of Tides in the East Asian Marginal Seas (동아시아 해역의 조석 모형)

  • 최병호;고진석
    • Journal of Korean Society of Coastal and Ocean Engineers
    • /
    • v.6 no.1
    • /
    • pp.94-108
    • /
    • 1994
  • As satellite altimetry is being progressed to apply with higher precision to maginal seas. it is necessary to improve correction procedures for tidal signals in altimetry with more accurate tidal model than the well-known model of Schwiderski for studying marginal sea dynamics. As a first step, tidal regime of semidiurnal tides (M$_2$, S$_2$, $N_2$, $K_2$) and diurnal tides (K$_1$, $O_1$, P$_1$, Q$_1$) were computed with finer details of formulation of tidal model over the East Asian Marginal Seas covering the Okhotsk Sea and South China Sea and part of Northwest Pacific Ocean with mesh resolutions of 1/6$^{\circ}$. Computed results were discussed with observations, previous tidal charts and Schwiderski's tidal map of the region.

  • PDF

The Estimation of the Closed Form in NKPC Inflation Model: Focusing on the Korean Manufacturing Industries (1975-2010)

  • Bae, Joo Han;Kang, Joo Hoon;Hong, Seonghyi;Yoon, Ayoung
    • Journal of Korea Society of Industrial Information Systems
    • /
    • v.19 no.3
    • /
    • pp.75-85
    • /
    • 2014
  • This paper is to develop and estimate a closed form inflation model using the estimates for real marginal costs in manufacturing industries during the sample period 1975-2010. The production function in manufacturing industry incorporates labor, capital, domestic material, and foreign material, assuming constant returns to scale technology and AR(1) process of technological coefficient. We derive real marginal costs from firm's cost minimization with quarterly data and provide new evidences on the new Keynesian Phillips curve for Korea. The main empirical result is that the closed form coefficients ${\delta}_1$ and ${\delta}^{-1}_2$ in manufacturing for PPI inflation proved to be 0.5086 and 0.8779 respectively, similar to the estimates in the U.S. case. These results also are consistent with the functional relationship between the coefficients in hybrid model and its closed form. Thus the paper suggests that the empirical studies on inflation dynamics need to focus on the manufacturing industry with market power, treating PPI inflation as the dependent variable.

Estimating survival distributions for two-stage adaptive treatment strategies: A simulation study

  • Vilakati, Sifiso;Cortese, Giuliana;Dlamini, Thembelihle
    • Communications for Statistical Applications and Methods
    • /
    • v.28 no.5
    • /
    • pp.411-424
    • /
    • 2021
  • Inference following two-stage adaptive designs (also known as two-stage randomization designs) with survival endpoints usually focuses on estimating and comparing survival distributions for the different treatment strategies. The aim is to identify the treatment strategy(ies) that leads to better survival of the patients. The objectives of this study were to assess the performance three commonly cited methods for estimating survival distributions in two-stage randomization designs. We review three non-parametric methods for estimating survival distributions in two-stage adaptive designs and compare their performance using simulation studies. The simulation studies show that the method based on the marginal mean model is badly affected by high censoring rates and response rate. The other two methods which are natural extensions of the Nelson-Aalen estimator and the Kaplan-Meier estimator have similar performance. These two methods yield survival estimates which have less bias and more precise than the marginal mean model even in cases of small sample sizes. The weighted versions of the Nelson-Aalen and the Kaplan-Meier estimators are less affected by high censoring rates and low response rates. The bias of the method based on the marginal mean model increases rapidly with increase in censoring rate compared to the other two methods. We apply the three methods to a leukemia clinical trial dataset and also compare the results.

Precision of the milled full-arch framework fabricated using pre-sintered soft alloy: A pilot study

  • Woo, Hyun-Wook;Cho, Sung-Am;Lee, Cheong-Hee;Lee, Kyu-Bok;Cho, Jin-Hyun;Lee, Du-Hyeong
    • The Journal of Advanced Prosthodontics
    • /
    • v.10 no.2
    • /
    • pp.128-131
    • /
    • 2018
  • PURPOSE. This study aimed to evaluate the marginal discrepancy of full-arch frameworks in implant-supported prostheses fabricated using pre-sintered soft alloy (PSA). MATERIALS AND METHODS. Full-arch metal frameworks were fabricated on the edentulous implant model using casting alloy (CA), fully-sintered hard alloy (FHA), and PSA (n = 4 in each group). To evaluate the misfit of the framework to the abutments, the absolute marginal discrepancy (AMD) values of the frameworks were measured in cross-sectional images that had been drawn as part of the triple-scan protocol. The AMD values were compared among the tested alloy groups using the Kruskal-Wallis test, with a post hoc Mann-Whitney U test (${\alpha}=.05$). RESULTS. The FHA and PSA groups showed lower marginal discrepancies than the CA group (P<.001). However, the FHA group did not differ significantly from the PSA group. CONCLUSION. Soft alloy milling is comparable to hard alloy milling, and it is more precise than casting in terms of the marginal fit of implant-supported, full-arch prostheses.