• Title/Summary/Keyword: marginal Mg

Search Result 90, Processing Time 0.019 seconds

Pharmacokinetics of a New Histone Hl Protein (p961), an Arthritis-suppressing Agent, in Rats and Rabbits (항류마치스 효과를 갖는 새로운 히스톤 H1 단백질 (p961)의 흰쥐와 토끼에 대한 약물동태)

  • 우수경;윤민혁;이재흥;권광일
    • YAKHAK HOEJI
    • /
    • v.45 no.4
    • /
    • pp.378-386
    • /
    • 2001
  • A purified histone Hl protein, p961, which plays a role in mediating the condensation of DNA into chromatin, was recently proved as an arthritis-suppressing agent in the mouse CIA model. The pharmacokinetics of p961 was carried out in rats and rabbits. The rat's blood, bile and urine samples were serially collected from the femoral vein, common bile duct, and bladder respectively, after bolus i.v. injection at low (10 mg/kg) and high (30 mg/mg) doses. The rabbit's blood samples were also collected from the marginal ear vein after bolus i.v. injection at a dose 10 mg/kg. p961 and its major metabolite in the physiological samples were analyzed by reverse-phase HPLC using a Yydac C4 protein column and a multistep water-acetonitrile gradient containing 0.24% trifluoroacetic acid. The major pharmacokinetic parameters (AUC, $C_{max}$, MRT, $t_{1}$2/, $V_{ss}$ and Cl) were estimated from the time course of plasma p961 and metabolite concentrations using WinNonlin. A two-compartment model was chosen for p961 as the most appropriate pharmacokinetic model. After i.v. injection of p961 at doses of 10 mg/kg and 30 mg/kg, more than 80% of p961 was removed rapidly from the plasma within 15 min. The plasma half-life of p961 in rats and rabbits was found not to exceed 12 min. p961 (22448.9 mol wt) was rapidly cleaved to 21612 mot wt fragment and the breakdown product appeared rapidly in the circulation with no lag phase. p961 and metabolite were not detected in rat urine and bile....

  • PDF

Effect of Mg Concentration in Fertigation Solution on Growth and Nutrient Uptake of Cut Chrysanthemum 'Biarritz' (Mg시비농도가 절화국 'Biarritz지 생육과 양분 흡수에 미치는 영향)

  • Kim, Jeong-Man;Choi, Jong-Myung;Chung, Hae-Joon
    • Journal of Bio-Environment Control
    • /
    • v.14 no.2
    • /
    • pp.119-127
    • /
    • 2005
  • This study was carried out to investigate the effect of magnesium concentrations in fertilizer solution on growth and cut flower quality of chrysanthemum 'Biarritz'. The nutrient concentrations in plant tissue and soil solution of root media were also determined. Magnesium deficiency appeared on older leaves with interveinal yellow-green chlorosis. Marginal chlorosis and necrosis also developed on some of older leaves. Elevation of Mg concentration in fertilizer solution increased cut flower weight at harvesting stage resulting in the 8.84g in 1.5mM treatment. Dry weight of whole above ground plant tissue increased as Mg concentrations in fertilizer solution were elevated within the range from 0 to 15mM, but that of 20mM decreased compared to 15mM treatment. The dry weight of 0.5, 1.0 and 1.5mM treatments were 8.42, 8.75 and 8.848 and tissue Mg contents of those based on the youngest fully expanded leaves at harvesting stage were 0.34, 0.53 and $0.71\%$, respectively. Based on dry weight and tissue Mg contents, Mg fertilization to maintain tissue contents higher than $0.64\%$ is necessary to ensure flower quality and yield. By considering the concentration in 15mM treatment, Mg concentration in soil solution of root media should be higher than $3.68mg{\cdot}L^{-1}$ at harvesting stage.

Evaluation of Antioxidant Status and Correlation among Antioxidant Indices in Female College Students

  • Kim, Jung-Hee;Heajoon Ahn
    • Journal of Community Nutrition
    • /
    • v.5 no.1
    • /
    • pp.13-20
    • /
    • 2003
  • This study was done to evaluate the antioxidant status of female college students by determining their intakes and plasma levels of antioxidnt vitamins (vitamin C, A and E) and total antioxidant status (TAS). Subjects were 46 healthy female college students aged 20 - 29 years. Body composition was determined by a multifrequency bioelectrical impedance analysis. Dietary intakes were examined by 24hr record method and nutrients intakes were analyzed by the Computer Aided Nutritional analysis program for professional (CAN-pro). Plasma vitamin C level were measured by spectrophotometric method and retinol, ${\beta}$-carotene, ${\alpha}$-tocopherol were measured by HPLC. Plasma TAS was measured with a Randox kit using the trolox equivalent antioxidant capacity (TEAC) method. Daily energy and protein intakes of the female college students were 1670.5㎉ (83% of RDA) and 63.3g (115.1% of RDA), respectively. However their intakes of Ca and Fe were below 75% of RDA. Their intakes of vitamin A and C were 596.6 ${\mu}$ gRE (85.2% of RDA) and 71.0mg (101.4% of RDA), respectively. Plasma levels of vitamin C, retinol, ${\beta}$-carotene and ${\alpha}$-tocopherol were 14.7mg/L, 0.7mg/L, 0.2mg/L and 9.1mg/L, respectively which were within normal range. There was no subject with deficiency or marginal level in plasma vitamin A and C. However 1.6% of the subjects had below adequate level in vitamin E. Plasma TAS level was 1.2mmol/L. Correlation data showed that all plasma antioxidant vitamins were positively correlated with plasma TAS. Overall data indicate that the antioxidant status of female college students were pretty good. However it might be necessary to educate them to eat more fruits and vegetables for preventing many chronic diseases in a later life. (J Community Nutrition 5(1) : 13∼20, 2003)

Histomorphometry and Stability Analysis of Loaded Implants with two Different Surface Conditions in Beagle Dogs (하중을 가한 두 가지 표면의 임플란트에 관한 조직형태학적 분석 및 안정성 분석 (비글견을 이용한 연구))

  • Kim, Sang-Mi;Kim, Dae-Gon;Cho, Lee-Ra;Park, Chan-Jin
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.24 no.4
    • /
    • pp.337-349
    • /
    • 2008
  • Despite an improved bone reactions of Mg-incorporated implants in the animals, little yet has been carried out by the experimental investigations in functional loading conditions. This study investigated the clinical and histologic parameters of osseointegrated Mg-incorporated implants in delayed loading conditions. A total of 36 solid screw implants (diameter 3.75 mm, length 10mm) were placed in the mandibles of 6 beagle dogs. Test groups included 18 Mg-incorporated implants. Turned titanium Implants served as control. Gold crowns were inserted 3 months. Radiographic assessments and stabilitytests were performed at the time of fixture installation, $2^{nd}$ stage surgery, 1 and 3 months after loading. Histological observations and morphometrical measurements were also performed. Of 36 implants, 32 displayed no discernible mobility, corresponding to successful clinical function. There was no statistically significant difference between test implants and controls in marginal bone levels (p=0.413) and RFA values. The mean BIC % in the Mg-implants was $54.4{\pm}20.2%$. The mean BIC % in the turned implant was $48.9{\pm}8.0%$. These differences between the Mg-implant and control implant were not statistically significant (P=0.264). In the limitation of this study, bone-to-implant contact (BIC) and bone area of Mg-incorporated oxidized implant were similar to machine-turned implant. The stability analysis showed no significantly different ISQ values and marginal bone loss between two groups. Considering time-dependent bone responses of Mg-implant, it seems that Mg-implants enhanced bone responses in early loading conditions and osseointegrated similarly to cp Ti implants in delayed loading conditions. However, further investigations are necessary to obtain long-term bone response of the Mg-implant in human.

The study on correlation between the levels of ascorbic acid in diet and serum (우리나라 여대생의 식이와 혈청이 ascorbic acid 수준의 상관관계 평가 - 섭취량 계산방법에 따른 비교 연구 -)

  • 계승희
    • Journal of the Korean Home Economics Association
    • /
    • v.32 no.1
    • /
    • pp.181-188
    • /
    • 1994
  • The purpose of this study is to evaluate nutritional status of ascorbic acid in 96 Korean female college students. Dietary intake level was estimated with three day diet records. Serum ascorbic acid were analyzed with fasting blood. Nutrient intakes was calculated using three different food composition databases ; analysis data of cooked food items ; analysis data of raw foods ; published food composition table. Ascorbic acid intake levels calculated with different food composition databases differed by 15% Using analysis data of cooked foods resulted in the lowest intake level 49.26 mg per day. Main sources of ascorbic acid investigated were Cheju mandarin orange juice and hard persimmon orange juice and Kimchi. Mean value of serum ascorbic acid level was 1.04 mg/dl and 4.2% of subjects were in marginal risk or deficient range. It was found to significantly correlate asscorbic acid intake with serum ascorbic acid content. Correlation coefficient with results calculated using analyzed data was higher than that using published data. Serum levels and mean daily intake levels of ascorbic acid in the subjects were significantly correlated. From these results it is concluded that ascorbic acid content of cooked foods should be included in the Food Composition Tables in Korea. Korean female college students were in lower risk of ascorbic acid deficiency.

  • PDF

Modeling of Ammonia Mass Transfer Using a Hollow Fiber Membrane Contactor (중공사막 접촉기를 이용한 암모니아 물질전달 모델링)

  • Oh, Dae-Yang;Jeong, Joo-Young;Choi, Won-Ho;Park, Joo-Yang
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.25 no.4
    • /
    • pp.503-510
    • /
    • 2011
  • Ammonia in water which is toxic to human, its concentration is regulated below 0.5 mg/L in drinking water. Current study aimed to develop appropriate models for ammonia stripping using hollow fiber membrane contactor. Two different models were developed during the study. Model 1 was assumed only free ammonia ($NH_3$) transfer in stripping process, whereas the Model 2 was assumed with total ammonia ($NH_3+{NH_4}^+$) transfer. Ammonium chloride ($NH_4CI$), sodium hydroxide(NaOH) were used to make ammonia solution, which was concentration of 25 mg as N/L at a pH of 10.5. The experimental conditions were such that, the liquid flow was in tube-side in upward direction and t he gas flow was on shell-side in downward direction a t room temperature. The experimental and modeling results showed that marginal difference were observed at low gas flux. However the difference between the both models and experimental value were increased when the gas flux was increased. The study concludes that the Model 1 with free ammonia is more appropriate when both models were compared and useful in ammonia stripping process at low gas flux.

Comparison of relative fitness between zirconia single coping and 3-unit fixed partial dentures (FPDs) manufactured by dental CAD/CAM system (치과 캐드/캠 시스템으로 제작된 지르코니아 single 코핑과 3-unit 구조물의 상대적 적합도 비교)

  • Lee, Wan-Sun;Park, Jong-Kyoung;Kim, Wook-Tae
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.30 no.1
    • /
    • pp.16-22
    • /
    • 2014
  • Purpose: The purpose of this study was to assess the marginal and mesial fitness of zirconia single copings and 3-unit fixed partial dentures (FPDs) manufactured with an identical model. Materials and Methods: An epoxy model in which the maxillary right 2nd premolar is lost and maxillary 1st premolar and 2nd molar are formed as abutments was manufactured and scanned by using a laser scanner. A ten units of zirconia single copings were manufactured for maxillary 1st premolar and 2nd molar, respectively and the same number of 3-unit FPDs were manufactured. For the measurements of fitness, the manufactured silicone replicas were divided into four parts and the fitness were measured by digital microscope at measurement points (P1, P2, P3, P4 and P5) of each plane. The measured gaps were classified into three categories: marginal gap (MG, P1), axial gap (AG, average of P2 and P3), occlusal gap (OG, average of P4 and P5). Results: The ranges of MG, AG and OG for single copings were 18.47 - 40.54 ${\mu}m$, 39.73 - 73.61 ${\mu}m$ and 116.90 - 134.69 ${\mu}m$, respectively. The ranges of MG, AG and OG for 3-unit FPDs were 45.95 - 87.44 ${\mu}m$, 23.78 - 57.00 ${\mu}m$ and 99.89 - 131.06 ${\mu}m$, respectively. Conclusion: The result of the study shows that the MGs for 3-unit FPDs were higher than those of single copings, though they are within the range of clinical acceptance, indicating that the use of more homogeneous zirconia block and modification of sintering processes are needed to ensure the prevention of increase of gap in 3-unit FPDs.

Studies on the Mass Propagation of Pinellia ternata (Thunb.) Breit in Vitro (조직배양에 의한 반하〔Pinellia ternata(Thunb.) Briet〕의 대량번식에 관한 연구)

  • 최정식;나의식
    • KOREAN JOURNAL OF CROP SCIENCE
    • /
    • v.31 no.1
    • /
    • pp.30-42
    • /
    • 1986
  • In order to find out the best media, explants and environmental conditions for induction of calluses and organogeneses of Pinellia ternata (Thunb.) Breit in vitro, various parts of adult have been cultured on Murashige & Skoog's medium containing various levels of 2,4-dichlorophenoxy acetic acid(2,4-D) and kinetin. The results obtained were as follows: Calluses were induced from the surface of apical meristem and leaf tissue. Formation and growth of calluses in petiole ex plants were best on the MS medium complemented with 2,4-D 2.0 mg/l and kinetin 0.2mg/l. But callus formation in stem ex plants of the nearest tuber was not induced at all kinds of media. Plantlets occured at all treatment except absence of growth regulator. Their numbers, size, leaf and fresh weight were promoted by 2,4-D 2.0mg/l and kinetin 0.2mg/l. Root growth was increased on the medium containing higher 2,4-D concentrations. Size and fresh weight of callus were increased at 25$^{\circ}C$ compared with 10, 20 and 30$^{\circ}C$, respectively. Optimal pH value was at 6.0 for growth of callus. Morphological aberrations were observed in plantlets, especially in regenerated leaves. The separation of the broad leaved plantlets and albino were observed in some cultures. Growth of plantlets after transplantation was best in pots with the sterilized vermiculte. But abnormal variants withered up.

  • PDF

THE EXPERIMENTAL STUDY ON THE INFLUENCE OF SUCROSE-OVERDOSAGE ON RAT ORAL MUCOSA (과당투여가 가토 구강점막조직에 미치는 영향에 관한 연구)

  • Rhee, Choon-Geun
    • The Journal of the Korean dental association
    • /
    • v.19 no.2 s.141
    • /
    • pp.163-166
    • /
    • 1981
  • Sugar consumption has been increased in recent days according to an improvement in living conditions. It is generally accepted that sugar is one of the causes of caries and that diabetes mellitus is closely related to the periodontal diseases. This investigation was designed to gain informations on the influence of overdosage of sugar and/or high blood sugar level on the periodontal tissue. 12 rats weighing about 1.5Kg were divided into 4 groups, control one and 3-day, 7-day, 14-day ones after daily administration of 30-50 gm of sucrose. The results were as follows: 1. Daily adminisration of 30-50 gm of sucrose elevated blood glucose level as much as 10-20 mg% than before. 2. Epithelial keratinization was gradually conspicuous to the dosage of sucrose. 3. The severity of inflammatory infiltration was also increased to the dosage of sucrose. 4. Inflammatory infiltration was encountered in marginal gingiva more than other periodontal tissue.

  • PDF

Evaluation of different approaches for using a laser scanner in digitization of dental impressions

  • Lee, Wan-Sun;Kim, Woong-Chul;Kim, Hae-Young;Kim, Wook-Tae;Kim, Ji-Hwan
    • The Journal of Advanced Prosthodontics
    • /
    • v.6 no.1
    • /
    • pp.22-29
    • /
    • 2014
  • PURPOSE. This study aimed to investigate the potential clinical application of digitized silicone rubber impressions by comparing the accuracy of zirconia 3-unit fixed partial dentures (FPDs) fabricated from 2 types of data (working model and impression) obtained from a laser scanner. MATERIALS AND METHODS. Ten working models and impressions were prepared with epoxy resin and vinyl polysiloxane, respectively. Based on the data obtained from the laser scanner (D-700; 3Shape A/S, Copenhagen, Denmark), a total of 20 zirconia frameworks were prepared using a dental CAD/CAM system (DentalDesigner; 3shape A/S, Copenhagen, Denmark / Ener-mill, Dentaim, Seoul, Korea). The silicone replicas were sectioned into four pieces to evaluate the framework fit. The replicas were imaged using a digital microscope, and the fit of the reference points (P1, P2, P3, P4, P5, P6, and P7) were measured using the program in the device. Measured discrepancies were divided into 5 categories of gaps (MG, CG, AWG, AOTG, OG). Data were analyzed with Student's t-test ($\alpha$=0.05), repeated measures ANOVA and two-way ANOVA (${\alpha}=0.05$). RESULTS. The mean gap of the zirconia framework prepared from the working models presented a narrower discrepancy than the frameworks fabricated from the impression bodies. The mean of the total gap in premolars (P=.003) and molars (P=.002) exhibited a statistical difference between two groups. CONCLUSION. The mean gap dimensions of each category showed statistically significant difference. Nonetheless, the digitized impression bodies obtained with a laser scanner were applicable to clinical settings, considering the clinically acceptable marginal fit ($120{\mu}m$).