• Title/Summary/Keyword: manufactured device

Search Result 627, Processing Time 0.042 seconds

Electrical Properties of Organic Thin Films by Deposition Type (유기박막의 누적형태에 따른 전기특성)

  • 송진원;이경섭
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2000.11a
    • /
    • pp.287-290
    • /
    • 2000
  • We give pressure stimulation into organic thin films and then manufacture a device under the accumulation condition that the state surface pressure is 20[mN/m]. LB layers of Arac. acid deposited by LB method were deposited onto y-type silicon wafer as x, y, z-type film. In processing of a device manufacture, we can see the process is good from the change of a surface pressure for organic thin films and transfer ratio of area per molecule. The structure of manufactured device is Au/arachidic acid/Al, the number of accumulated layers. Also, we then examined of the MIM device by means of I-V. The I-V characteristic of the device is measured from 0 to +2[V].

  • PDF

Effect of Vibration Suppression Device for GNSS/INS Integrated Navigation System Mounted on Self-Driving Vehicle

  • Park, Dong-Hyuk;Ahn, Sang-Hoon;Won, Jong-Hoon
    • Journal of Positioning, Navigation, and Timing
    • /
    • v.11 no.2
    • /
    • pp.119-126
    • /
    • 2022
  • This paper presents a method to reduce the vibration-induced noise effect of an inertial measurement device mounted on a self-driving vehicle. The inertial sensor used in the GNSS/INS integrated navigation system of a self-driving vehicle is fixed directly on the chassis of vehicle body so that its navigation output is affected by the vibration of the vehicle's engine, resulting in the degradation of the navigational performance. Therefore, these effects must be considered when mounting the inertial sensor. In order to solve this problem, this paper proposes to use an in-house manufactured vibration suppression device and analyzes its impact on reducing the vibration effect. Experimental test results in a static scenario show that the vibration-induced noise effect is more clearly observed in the lateral direction of the vehicle, but can be effectively suppressed by using the proposed vibration suppression device compared to the case without it. In addition, the dynamic positioning test scenario shows the position, speed, and posture errors are reduced to 74%, 67%, and 14% levels, respectively.

Study on characteristics of Red OLED doped with rubrene (rubrene을 도핑한 Red OLED 특성 연구)

  • Lee, Jeong-Ho;Jeong, Ji-Hun;Kim, Yeong-Gwan
    • Proceedings of the Optical Society of Korea Conference
    • /
    • 2005.02a
    • /
    • pp.166-167
    • /
    • 2005
  • The doping technique has been well known as method to get various emission color by choosing appropriate fluorescent dyes as a dopant. Usually, red emission of OLED device based on Alg$_{3}$ doped with DCM and rubrene is fabricated. Result that fabricate OLED device was manufactured by various doping density, we looked for the doping ratio of highest luminescent efficiency.

  • PDF

A Technique Security Analysis Using Cryptography of RFID Device

  • Bono, Stephen C.;Green, Matthew;Stubblefield, Adam
    • 한국정보컨버전스학회:학술대회논문집
    • /
    • 2008.06a
    • /
    • pp.161-168
    • /
    • 2008
  • We describe our success in defeating the security of an RFID device known as a Digital Signature Transponder(DST). Manufactured by Texas Instruments, DST(and variant) devices help secure millions of SpeedPassTM payment transponders and automobile ignition keys.

  • PDF

Regulation Issues in Korea and Technical Feasibility Evaluation of 3D Printing-Based Medical Device Repair (3D 프린팅 기술의 의료기기 수리 적용에 대한 국내 규제 이슈 및 기술적 적합성 평가)

  • Yun, Sung Uk;Nam, Kyoung Won
    • Journal of Biomedical Engineering Research
    • /
    • v.41 no.2
    • /
    • pp.75-83
    • /
    • 2020
  • In large-scale hospitals, the department of biomedical engineering should always provide quick repair service for damaged medical devices to guarantee continuous patient treatment. However, in actual circumstances, there are so many time-consuming issues that delays device repair for weeks or even months; therefore, it is required to prepare alternative ways for quick repair service. In this study, we first mentioned about the regulation issues in Korea about the 3D printing-based medical device repair, and then introduced the results of our preliminary study that evaluated the feasibility of 3D printing-based medical device repair before real-field application. Results of the study demonstrated that, in all of the 23 cases, parts for repair that were manufactured by 3D-printing were successfully fixed and connected to the main body of the original device, and showed sufficient rigidity for protecting internal parts of the device. Considering the experimental results, medical device repair by applying 3D printing technology can be a promising alternative in cases when regular repair process is not available or takes too much time.

Development of the Pointing Device using EOG (EOG를 이용한 포인팅 디바이스의 개발)

  • Park, Hyoung-Joon;Park, Jong-Hwan;Chun, Woo-Young
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.48 no.10
    • /
    • pp.1356-1363
    • /
    • 1999
  • In this paper, a new method for controlling the pointing device using EOG(electrooculogram) signal generated from eye movement was suggested. The basic idea of the method is to control the direction of pointer, as using the results of measuring each component of the horizontal EOG and the vertical EOG by angle of eye-gaze. As a practical example, pointing device controlling the personal computer's pointer is manufactured. The designed pointing device consists of pre-amplifier, A/D converter, serial transmission device and PC program. That is, first, the EOG is amplified by pre-amplifier. Secondly, the amplified EOG is digitized and transmitted to personal computer by PIC16C74A. Finally, the software for controlling the pointer on personal computer is programed. As the result, the measured horizontal EOG and vertical EOG by eye-gaze angle had high linearity; the correlation coefficients of the regression line were 0.998 and 0.996 respectively. And the developed pointing device is able to control the personal computer's pointer, and the average of the errors between the objective value and the observed value had 3.77% for horizontal axis and 5.85% for vertical axis. The pointing device developed in this study is able to control personal computer's pointer by subject's eye movement, that is, the user's intention. Furthermore, the algorithm of this study is applicable for many field, such as a new method remote control, a new wheelchair control and so forth.

  • PDF

Development of the Spent Fuel Rod Cutting Device by Cutter Blade Method (Cutter blade 방식에 의한 사용후핵연료봉 절단 장치 개발)

  • 정재후;윤지섭;홍동회;김영환;김도우
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2000.11a
    • /
    • pp.393-396
    • /
    • 2000
  • Spent fuel rod cutting device should cut a spent fuel rod to an optimal size in order to fast decladding operation. In this paper, for developing spent fuel rod cutting device with cutter blade, rod properties such as dimension and material of zircaloy tube and fuel pellet are investigated at first and then, various methods of existing cutting devices used commercially are investigated and their performance are analyzed and compared. This device is designed to be operated automatically via remote control system considering later use in Hot-Cell (radioactive area) and the mdularization in the structure of this device makes maintenance easy. SUS and Zircaloy-4 are selected as cut material used in the test of spent fuel rod cutting device by cutter blade. In order for constructing the high durable cutter blade, various materials are analyzed in terms of quality, shape, characteristic, and heat treatment, etc. and from these results, spent fuel rod cutting device is designed and manufactured based on the considerations of durability, round shape sustainability of rod cross-section, debris generation, and fire risk, etc.

  • PDF

Development of Novel Joint Device for a Disposal Canister in Deep Borehole Disposal (고준위폐기물 심부시추공 처분을 위한 처분용기 접속장치의 개발)

  • LEE, Minsoo;LEE, Jongyoul;JI, Sung-Hoon
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.16 no.2
    • /
    • pp.261-270
    • /
    • 2018
  • In this study, to replace the 'J-slot joint', a joint device between a disposal canister and an emplacement jig in Deep Borehole Disposal process, a novel joint device was designed and tested. The novel joint device was composed of a wedge on top of a disposal canister and a hook box at the end of a winch system. The designed joint device had merits in that it can recombine an emplaced canister freely without the replacement of the joint component. Moreover, it can be applied to various emplacement jigs such as drill pipes, wire-lines, and coiled tubing. To demonstrate the designed joint device, the joint device (${\Phi}110mm$, H 148 mm), a twin canister string (${\Phi}140mm$, H 1,105 mm), and a water tube (${\Phi}150mm$, H 1,500 mm) as a borehole model were manufactured at 1/3 scale. As deployment muds, Na-type bentonite (MX-80) and Ca-type (GJ II) bentonite muds were prepared at solid contents of 7wt% and 28wt%, respectively. The manufactured joint device showed good performance in pure water and viscous muds, with an operation speed of $10m{\cdot}min^{-1}$. It was concluded that the newly developed joint device can be used for the emplacement and retrieval of a deep disposal canister, below 3~5 km, in the future.

A study on the Dielectric Characteristics of Polyimide Organic Ultra Thin Films (폴리이미드 유기초박막의 유전특성에 관한 연구)

  • Chon, D.K.;Lee, K.S.
    • Proceedings of the KIEE Conference
    • /
    • 1999.07d
    • /
    • pp.1744-1746
    • /
    • 1999
  • In this paper, we give pressure stimulation into organic ultra thin films and detected the induced displacement current properties, and then manufacture a device under the accumulation condition. In processing of a device manufacture, we can see the process is good from the change of a surface pressure and transfer ratio of area per molecule of organic ultra thin films. The structure of manufactured device is MIM(Au/polyimide LB films/AU), the number of accumulated 19 layers. I-V characteristic of the device is measured from -5[V] to +5[V]. The maximum value of measured current is increased as the number of accumulated layers are decreased. The insulation of a thin film is better as the interval between electrodes is larger, and the insulation properties of a thin film is better as the distance between electrodes is larger.

  • PDF

Characteristic and Development of Measurement Device for Particulate Matters on the Subway Tunnels (도시철도 터널에서의 미세먼지 특성 파악 및 측정 장치 개발)

  • Park, Duck-Shin;Bhang, Youn-Keun;Kwon, Soon-Bark;Jeong, Woo-Tae;Cho, Young-Min;Shin, Chang-Hun
    • Proceedings of the KSR Conference
    • /
    • 2011.10a
    • /
    • pp.1289-1297
    • /
    • 2011
  • Objective of this study was to characterize $PM_{10}$ sources on subway tunnels and development of simple particulate matters measuring device based on wireless sensor network. A new wireless sensor module, PMX, has been designed and manufactured to measure $PM_{10}$ and$PM_{2.5}$ simultaneously. The measurements have been conducted at a specific subway station on the Seoul metro line. The accuracy of the device was verified and compared with commercial measuring device based on weighting method.

  • PDF