• Title/Summary/Keyword: manual-based test

Search Result 299, Processing Time 0.028 seconds

An Automated Test Technique of GUI Based on Source Code (소스코드기반의 GUI 테스트 자동화 기법의 구현)

  • Moon, Joong-Hee;Lee, Nam-Yong
    • Journal of KIISE:Software and Applications
    • /
    • v.36 no.9
    • /
    • pp.697-705
    • /
    • 2009
  • A GUI automated test can be divided into two areas. The first one is a regression test automation and the second one is an automated test. The former includes generating test cases manually and executing them automatically but the latter includes both generating test cases and executing them automatically. Costs of a software test are increasing more and more. Many companies are searching for a test automation method but most used things are limited to regression test automation. So, when testing at first, there should be test cases which are drawn up by a human. This paper explains to make test cases based on a source code and execute them automatically. In this paper, the study proceeds with a digital television set-top box application and explains to test without any effort of human. Of course, this study is far from a realization to industries. But this paper has a contribution at reducing more human efforts than the previous regression test automation and showing that later, fully automated test can be possible.

An Autonomous Operational Service System for Machine Vision-based Inspection towards Smart Factory of Manufacturing Multi-wire Harnesses

  • Seung Beom, Hong;Kyou Ho, Lee
    • Journal of information and communication convergence engineering
    • /
    • v.20 no.4
    • /
    • pp.317-325
    • /
    • 2022
  • In this study, we propose a technological system designed to provide machine vision-based automatic inspection and autonomous operation services for an entire process related to product inspection in wire harness manufacturing. The smart factory paradigm is a valuable and necessary goal, small companies may encounter steep barriers to entry. Therefore, the best approach is to develop towards this approach gradually in stages starting with the relatively simple improvement to manufacturing processes, such as replacing manual quality assurance stages with machine vision-based inspection. In this study, we consider design issues of a system based on the proposed technology and describe an experimental implementation. In addition, we evaluated the implementation of the proposed technology. The test results show that the adoption of the proposed machine vision-based automatic inspection and operation service system for multi-wire harness production may be considered justified, and the effectiveness of the proposed technology was verified.

A Case Report on Ossification of Posterior Longitudinal Ligament Treated by Korean Medicine: Focusing on Chuna Therapy (경추간판 장애 및 척수병증을 동반한 후종인대골화증 환자에 대한 한의 복합 치료 1례 증례보고: 추나 요법을 중심으로)

  • Hong, Min-Woo;Kim, Jae-Kyoun;Park, Min-Jung;Yoon, Young-Heum;Kim, Su-Yong;Kim, Nam-Kwen
    • The Journal of Churna Manual Medicine for Spine and Nerves
    • /
    • v.15 no.1
    • /
    • pp.135-145
    • /
    • 2020
  • Objectives : This study reports the clinical case of a patient diagnosed with ossification of the posterior longitudinal ligament treated with Korean Medicine focusing on Chuna therapy. Methods : The patient was treated by a doctor from July 18th, 2019 to November 28th, 2019. The patient was diagnosed with ossification of the posterior longitudinal ligament based on magnetic resonance imaging results and was recommended to undergo surgery at another hospital. The primary complaint of the patient was left neck pain, left arm sensation, right leg sensation, and right leg loss of strength. The doctor treated the patient with Chuna therapy, acupuncture, cupping, herbal medicine, and pharmacopuncture. The effect of treatment was evaluated using visual analogue scale, neck disability index, pain rating score and Japanese Orthopedic Association score. Spurling, compression, and distraction tests were utilized. Results : Visual analogue scale decreased from 10 at the arm and 10 at the leg to 1 and 2, respectively. Neck disability index decreased from 25 to 11, pain rating score decreased from 66 to 1, and Japanese Orthopedic Association score recovered from 12 to 17 points. In addition, positive spurling test, compression test, and distraction test all improved to negative. Conclusions : Korean medicine treatment can be effective for ossification of the posterior longitudinal ligament patients, even when surgery is recommended. Further clinical studies, such as case series and case-control studies, are required to verify these findings.

Comparison of effects of 12 weeks of Pilates with Mini Ball versus Mat Pilates on strength, endurance, flexibility, and dynamic equilibrium in older adults. (12주간의 미니볼(Mini Ball)을 이용한 필라테스와 매트 필라테스가 노인의 근력, 전신지구력, 유연성, 동적평형성에 미치는 영향을 비교)

  • Myoung-Kwon Kim;Yong-Bum Jung;Eun-Hee Jeon
    • The Journal of Korean Academy of Orthopedic Manual Physical Therapy
    • /
    • v.29 no.1
    • /
    • pp.33-39
    • /
    • 2023
  • Background: Most Pilates programs for older adults have been based on mat Pilates, and there has been limited research on Pilates with mini-balls. Therefore, this study aims to compare the effects of Pilates with mini-balls and mat Pilates interventions on strength, total body endurance, flexibility, and dynamic equilibrium to determine the differences. Methods: The elderly aged 65 or older living in Gyeongsan, Daegu, were divided into two groups, and the experimental group (n=10) conducted a Pilates exercise program using mini balls for 12 weeks, and the control group (n=10) conducted a mat Pilates exercise program for 12 weeks without mini balls. Strength, endurance, flexibility, and dynamic equlibrium were measured as a pre-test, and post-test was performed in the same way after 12 weeks of application. Results: Comparing the mini-ball Pilates group to the mat Pilates group, there was a significant difference (p<.05) in the 'chair sit and reach' after the intervention. In the within-group comparison, there was a significant increase (p<.05) in 'arm curl right', '30-second chair stand', '2-minute walk', 'back scratch', 'chair sit and reach', and '2.44m up and go' in the experimental group using the mini-ball Pilates program. Mat Pilates program significantly increased the within-group comparisons in '30-second chair stand' and 'chair sit and reach' (p<.05). Conclusion: It is suggested that mini-ball Pilates has a positive effect on the senior fitness and will be a good exercise method for using it as an exercise program for the elderly in the future.

  • PDF

Electronic Pen-based Unilateral Visual Neglect Assessment and Rehabilitation System (전자펜 기반 편측시각무시(UVN) 환자 검사 및 재활치료 시스템)

  • Kim, Joonkyo;Jee, Haemi;Park, Jaehyun
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.20 no.6
    • /
    • pp.647-650
    • /
    • 2014
  • Assessment and rehabilitation of patients with unilateral visual neglect has been one of the fields that require assistive technology. Paper-and-pencil tests, including the LBT (Line Bisection Test), have been one of the most commonly used visual neglect assessment methods used in a clinical setting. The key motivation of this study was to establish a computer-based real-time assessment system for the hemi-neglect patients without altering the conventional paper-and-pencil based user tools. A digital penbased assessment and rehabilitation system, the ePen System, could eliminate the manual assessment time while maintaining measurement accuracy. As a result, the proposed system may assist rehabilitation specialists to assess and diagnose patients with unilateral visual neglect. This system can be applied to a range assessment and rehabilitation modalities based on a pen and paper. It can also be applied to various patients such as those with Parkinson's disease, stroke sufferers, or those who have experienced different forms of brain lesions.

A Microcomputer-Based Data Acquisition/Control System for Engine Performance Test(I) -Automation of Engine Performance Test and Data Acquisition- (마이크로컴퓨터를 이용한 엔진성능시험(性能試驗)의 자동화(自動化)에 관한 연구(硏究)(I) -엔진성능시험(性能試驗)과 데이터수집(蒐集)의 자동화(自動化)-)

  • Ryu, K.H.;Chung, C.J.;Park, B.S.
    • Journal of Biosystems Engineering
    • /
    • v.12 no.3
    • /
    • pp.7-16
    • /
    • 1987
  • This study was carried out to develop a microcomputer-based data acquisition and control system which was able to collect the data of engine performance test automatically and control the speed and load of the engine. The results of the study are summarized as follows: 1. The signal processing devices, which were able to measure cylinder pressure, coolant temperature, compositions of exhaust gas, fuel consumption, engine rpm and torque etc., were developed. The results of calibration showed that all of devices had high accuracy ranging from 0.3% to 0.69% respectively. 2. The PIA (peripheral interface adapter) for interfacing digital signal and PTM (programmable timer module) for displaying real time every 0.0408 sec were designed and developed. 3. An engine-speed control system using a stepping motor and driver was developed. The control system had the stability, and faster settling time than the manual control system. 4. The automatic control system of electrical dynamometer, which was able to control the speed and load of dynamometer, was developed with a SSD (shackleton system driver) and D/A converter. 5. The computer programs, which were able to collect and process the data of engine tests, were developed using both the machine language and BASIC.

  • PDF

The Effect of Exercise Program for Falls Prevention on Balance, Falls Efficacy, Blood Pressure and Blood Lipids in the Elderly Women (낙상예방 운동프로그램이 노인여성의 균형, 낙상효능감과 혈압 및 혈중지질에 미치는 영향)

  • Kim, Young-min
    • The Journal of Korean Academy of Orthopedic Manual Physical Therapy
    • /
    • v.21 no.2
    • /
    • pp.7-14
    • /
    • 2015
  • Purpose: The purpose of this study was to investigate the effects of falls prevention exercise program to balance, falls efficacy, blood pressure and blood lipids in the elderly females. Methods: A total of twenty-six elderly women participated in this study. All subjects participated in exercise program based on pelvic stabilization and balance training on two times a week for twelve weeks. They were measured about Berg balance scale (BBS), Time up and go (TUG), Functional reach test (FRT), Sit to stand (STS) for balance, falls efficacy scale-international (FES-I) for falls efficacy, systolic blood pressure (SBp), diastolic pressure (DSp) for blood pressure, and total cholesterol (TC), triglyseride (TG), high density lipoprotein cholesterol (HDL-C), low density lipoprotein cholesterol (LDL-C) for blood lipids. Results: There were significant improvements of BBS (p<.05), TUG (p<.001) FRT (p<.01), and STS (p<.001) in the balance after exercise program. There was significant improvements in FES-I (p<.001) in the falls efficacy, There were no statistical differences of SBp and DSp in the blood pressure. There were no statistical differences of TC, TG, HDL-C, and LDL-C in the blood lipids. Conclusions: Falls prevention exercise program was meaningful increasing balance ability and falls efficacy.

  • PDF

Structural Stability Analysis of Connectors for an Electric Handbike (휠체어 전동주행 보조기기용 커넥터의 구조안정성 해석)

  • Seo, Han Wool;Kim, Dae Dong;Ko, Cheol Woong;Lee, Joon Hmm;Bae, Tae Soo
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.32 no.5
    • /
    • pp.491-496
    • /
    • 2015
  • Electric handbike can be easily detachable to various sizes of manual wheelchair and the elderly and people with disabilities can use them easily. Therefore, connectors used for coupling between the handbike and manual wheelchair must secure structural stability for occupant safety. However, related research is rare. The aim of this study is to find the connector with highly structural stability by comparing static and dynamic mechanical characteristics among three typical connectors(a snatch lock, a slide latch, and a fastener) by computational simulations. To perform static and dynamic simulation, we referred to durability test based on Korean Standards and then calculated mechanical stresses in connectors. The results showed that the snatch lock addressed the lowest von-mises stress under the same mechanical condition. Therefore when using the combination of a handbike and a wheelchair, we concluded that the snatch lock is considered as the structurally stable connector to structural stability and usability.

Repeatability Test for the Asymmetry Measurement of Human Appearance using General-purpose Depth Cameras (범용 깊이 카메라를 이용한 인체 외형 비대칭 측정의 반복성 평가)

  • Jang, Jun-Su
    • Journal of Physiology & Pathology in Korean Medicine
    • /
    • v.30 no.3
    • /
    • pp.184-189
    • /
    • 2016
  • Human appearance analysis is an important part of both eastern and western medicine fields, such as Sasang constitutional medicine, rehabilitation medicine, dental medicine, and etc. By the rapid growing of depth camera technology, 3D measuring becomes popular in many applications including medical area. In this study, the possibility of using depth cameras in asymmetry analysis of human appearance is examined. We introduce the development of 3D measurement system using 2 Microsoft Kinect depth cameras and fully automated asymmetry analysis algorithms based on computer vision technology. We compare the proposed automated method to the manual method, which is usually used in asymmetry analysis. As a measure of repeatability, standard deviations of asymmetry indices are examined by 10 times repeated experiments. Experimental results show that the standard deviation of the automated method (1.00mm for face, 1.22mm for body) is better than that of the manual method (2.06mm for face, 3.44mm for body) for the same 3D measurement. We conclude that the automated method using depth cameras can be successfully applicable to practical asymmetry analysis and contribute to reliable human appearance analysis.

Effect of 1Hz Motor Nerve Electrical Stimulation on Joint Range of Motion

  • Jong Ho Kang
    • Physical Therapy Rehabilitation Science
    • /
    • v.11 no.4
    • /
    • pp.409-413
    • /
    • 2022
  • Objective: This study aims to compare the range of motion of the joints by applying the contraction and relaxation techniques used in manual therapy as electrical stimulation treatment. Based on this, we would like to propose the possibility of using motor nerve electrical stimulation therapy for musculoskeletal physical therapy. Design: Single-arm interventional study Methods: Active and passive straight leg raising tests were performed on 20 healthy men and women in their 20s to measure the angle of hip joint flexion. Then, the electrical stimulation time was set to 10 seconds and 5 seconds of rest, and motor nerve electrical stimulation of 1 Hz was applied with the maximum strength that could withstand the hamstring muscles for 10 minutes. After electrical stimulation, straight leg raising tests again to confirm the range of motion of the hip joint flexion. Results: As a result of this study, it was confirmed that the joint range of motion was significantly improved for both active and passive straight leg raising tests after application of motor nerve electrical stimulation(p<.05). Conclusions: With a strong electrical stimulation treatment of 1 Hz, the effect similar to the contraction and relaxation technique used in manual therapy was confirmed through the joint range of motion. In the future, motor nerve electrical stimulation therapy can be used for musculoskeletal physical therapy to provide a new approach for patients with reduced pain and joint range of motion due to muscle tension.