• Title/Summary/Keyword: mandibular premolar

Search Result 368, Processing Time 0.032 seconds

An Anatomical Study using CT Images for the Implantation of Micro-implants (CT 이미지를 사용한 Micro-implants 식립을 위한 매부학적 연구)

  • Park, Hyo-Sang
    • The korean journal of orthodontics
    • /
    • v.32 no.6 s.95
    • /
    • pp.435-441
    • /
    • 2002
  • Surgical microscrews were introduced and used as one method to provide absolute anchorage. Some clinicians implanted microscrews or miniscrews into the basal bone below the roots of the teeth to evade damage to the roots. Because the implanted microscrews were positioned too low the applied force was insufficient to retract the anterior teeth or protract the posterior teeth, and the use of microscrews or miniscrews seemed limited in applying vertical force. However Park implanted microscrews(micro-implants (1.2mm in diameter)) into the alveolar bone between the roots of the posterior teeth to change the direction of the applied force toward increasing horizontal component of the force. Moreover, these microscrew implants were positioned in the alveolar bone between the roots without causing discernable damage to the roots. This study was performed to provide guidelines and anatomic data to assist in the determination of the safe location for micro-implants. By measuring the CT images from 21 patients, anatomical data were obtained which were then used as a guide to determine the location for the implantation of micro-implants. The thickness of the cortical bones at the alveaolar bone region increased from the anterior to the posterior teeth area. The mandibular posterior teeth area showed thicker cortical bone. A greater distance was observed in distance between the second premolar root and first molar root in the upper arch, between the first molar root and the second molar root in the lower arch. The alveolar bone of the posterior teeth area is considered the best site for the implantation of micro-implants.

A study on the dental arch characteristics of bialveolar protrusion patients using a three-dimensional digital model (3차원 디지털 모형을 이용한 양악 치조골 전돌자의 치열궁 특성 연구)

  • Lee, Soo-Kyung;Sung, Jae-Hyun;Kwon, Oh-Won
    • The korean journal of orthodontics
    • /
    • v.36 no.1 s.114
    • /
    • pp.45-54
    • /
    • 2006
  • Recent beauty trends have caused an increase in the number of bialveolar protrusion patients seeking treatment of lip protrusion. But studies of these patients are not common. Studies using their dental models are especially rare. Dental models have been measured manually or through a computer by digitizing two dimensional images of models. Nowadays, we are able to study dental models more easily and accurately by utilizing the three-dimensional (3-D) laser scanner in dentistry. An investigation was carried out to evaluate the characteristics of the dental arch in a bialveolar protrusion group in comparison with a normal group using 3-D digital models. The normal group was composed of 20 subjects who were selected from students of the School of Dentistry, Kyungpook National University. The bialveolar protrusion group was composed of 20 subjects who visited for treatment at the Department of Orthodontics, Kyungpook National University Hospital. Tooth size, arch width and arch length were measured digitally, and arch shape and the shape of the palate were drawn. Based on the results of this study, the differences of the arch characteristics in the bialveolar protrusion group were that the size of the teeth was larger, mandibular canine width and 1st premolar width were wider, and arch length was longer than in the normal group. And there were differences in the arch shape and the shape of palate between the bialveolar protrusion and normal groups.

Autotransplantation of Ectopically Impacted Teeth : Two Case Reports (이소매복된 치아의 자가치아이식 증례)

  • Lim, Yuran;Kim, Jaehwan;Choi, Namki;Kim, Seonmi
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.44 no.1
    • /
    • pp.108-115
    • /
    • 2017
  • Numerous therapeutic approaches are available for impacted teeth, including orthodontic retraction, implantation, and autogenous tooth transplantation. Autotransplantation is a promising method, especially for juvenile patients, as it enables preservation of the function of the periodontal tissues, as well as continued alveolar bone growth. This report describes autotransplantation in two cases in which the tooth was fully-ectopically impacted. With case 1, an ectopically impacted premolar was extracted and transplanted in an upright position, and regenerative endodontic treatment was performed using a platelet-rich fibrin clot and mineral trioxide aggregate (MTA). With case 2, a calcifying odontogenic cyst with an impacted left mandibular second molar was treated by enucleation. The tooth was transplanted into the proper position 3 months after enucleation, and endodontic treatment was performed using MTA. In both cases, autotransplantation appeared to provide a simple and rapid treatment option for patients with ectopically impacted teeth. These cases demonstrate that autotransplantation of ectopically impacted teeth is a viable treatment option rather than implant placement or prosthesis, especially in juvenile patients.

An analysis of the dental arch and skeletal characteristics in adult patients exhibiting open bite (Openbite을 나타내는 성인의 치열 특성 및 그에 따른 골격적 특성 분석)

  • Lee, Jin-Woo
    • The korean journal of orthodontics
    • /
    • v.34 no.4 s.105
    • /
    • pp.289-301
    • /
    • 2004
  • It is the purpose of this study to characterize oral symptoms and to comprehend the cause and the relapse possibility of patients with open bite. This case study examines the orthodontic treatment of a group of female patients with open bite and Angle's Class I malocclusion. A cephalograph of the patient was taken and tracing of the radiograph was completed. In addition to Bjork and Ricketts analysis, additional measurements of specific areas were taken. The occlusal plane was determined by drawing a line connecting the mesiobuccal cusp tip of the maxillary first molar and the incisal edge of the maxillary central incisors. Patients were divided into two groups depending on the relationship between the marginal ridge of the maxillayy first premolar and the drawn line. Those patients with marginal ridges above the occlusal plane were placed into Group 1, while Group 2 subjects exhibited marginal ridges lower than the occlusal plane. The common characteristics within each group and the characteristic differences between each group both prior to and after orthodontic treatment were examined, and finally, the functional oral volume of each patient was analyzed. The results of the case study were as follows: 1. An examination of the skeletal relationship and anatomical form for both Group 1 and 2 showed that all subjects exhibited hyperdivergent skeletal forms, but Group 2 subjects generally demonstrated underdevelopment of the mandible and a smaller articular angle, resulting in an anterior positioning tendency of the mandible. 2. An analysis of the maxillary arches of Group 1 subjects prior to and after orthodontic treatment showed that the antero-inferior direction had changed to an antero-superior directional tendency, while the maxillary arches of the Group 2 patients showed a trend from an antero-superior direction to an antero-inferior relationship. The mandibular arches in both groups showed a change to an antero-superior direction. 3. Functional space analysis showed that Group 2 patients exhibited a greater tendency of haying palatal planes that drop in a postero-inferior direction, resulting in a more severe open bite than their Group 1 counterparts. The results of this case study show that although patients belonging to either Group 1 or 2 exhibited few external differences in the appearance of open bite, an examination of the dental and skeletal relationships by analyzing patient cephalographs showed that patients presenting with flat maxillary occlusal planes exhibited more severe open bite relationships than patients with curved occlusal planes.

Repeated failure of implants at the same site: a retrospective clinical study

  • Kang, Dong-Woo;Kim, So-Hyun;Choi, Yong-Hoon;Kim, Young-Kyun
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.41
    • /
    • pp.27.1-27.9
    • /
    • 2019
  • Background: Implants are becoming the first choice of rehabilitation for tooth loss. Even though they have a high success rate, failures still occur for many reasons. The objective of this study is to analyze the reasons for recurring failure at the same site and the results of re-implantation. Methods: Thirteen patients (11 males and 2 females, mean age 60 ± 9.9 years) who experienced implant surgery failure at the same site (same tooth extraction area) two or more times in the Department of Oral and Maxillofacial Surgery, Seoul National University Bundang Hospital, between 2004 and 2017 were selected. The medical records on a type, sites, diameter, and length of implants; time and estimated cause of failure; and radiographs were reviewed. Data were collected and analyzed retrospectively, and the current statuses were evaluated. Results: A total of 14 implants experienced failure in the same site more than two times. Twelve implants were placed in the maxilla, while 2 implants were placed in the mandible. The maxillary molar area was the most common site of failure (57.1%), followed by the mandibular molar, anterior maxilla, and premolar areas (14.3% each). The first failure occurred most commonly after prosthetic treatment (35.7%) with an average period of failure of 3.8 months after loading. Ten cases were treated as immediate re-implantation, while the other 4 were delayed reimplantation after an average of 3.9 months. The second failure occurred most commonly after prosthetic treatment (42.9%), with an average of 31 months after loading; during the healing period (42.9%); and during the ongoing prosthetic period (14.3%). In 3 cases (21.4%), the treatment plan was altered to an implant bridge, while the other 11 cases underwent another implant placement procedure (78.6%). Finally, a total of 9 implants (64.3%) survived, with an average functioning period of 60 months. Conclusions: Implants can fail repeatedly at the same site due to overloading, infection, and other unspecified reasons. The age and sex of the patient and the location of implant placement seem to be associated with recurring failure. Type of implant, bone augmentation, and bone materials used are less relevant.

PHOTOELASTIC STRESS ANALYSIS ON THE MANDIBLE CAUSED BY IMPLANT OVERDENTURE (임플랜트 Overdenture의 Bar설계에 따른 하악지지조직의 광탄성학적 응력분석)

  • Kang Jeong-Min;Vang Mong-Sook
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.32 no.2
    • /
    • pp.327-353
    • /
    • 1994
  • This study was performed to evaluate the effects of number and alignment of implant fixture and various bar designs on the retention of denture and the stress distribution. Six kinds of photoelastic mandibular models and nine kinds of overdenture specimens were designed. A unilateral vertical load was gradually applied on the right first molar to calculate the maximal dislodgement load of each specimen. A unilateral vertical load of 17 Kgf was applied on the right first molar and a vertical load of 10 Kgf was applied on the interincisal edge region. The stress pattern which developed in each photoelastic model was analyzed by the reflection polariscope. The results obtained were as follows: 1. The maximal dislodgement load reversely increased with the distance from the loading point to the implant fixture, while it linearly increased with that from the most posterior implant fixture to the mesial clip. The maximal dislodgement load also increased with the use of a cantilever bar. 2. Under the posterior vertical load, the stress to the supporting tissue of the denture base increased with the distance from the loading point to the implant future. The stress concentration on the apical area of the implant future reversely increased with the distance from the loading point to the implant future. 3. In the overdentures supported by two implant fixtures under the posterior vertical load. the specimen implanted on lateral incisor areas with a cantilever bar exhibited more favorable stress distribution than that without a cantilever bar. The specimen implanted on the canine areas without a cantilever bar, however, exhibited more favorable stress distribution. 4. In the overdentures supported by three implant fixtures. the specimen implanted ell the midline and canine areas exhibited more favorable stress distribution than that implanted oil the midline and the first premolar areas. 5. In the overdentures supported by four implant fixtures. the specimen implanted with two adjacent implant fixtures exhibited more favorable stress distribution than that implanted at equal distance under the posterior vertical load. 6. Under the anterior vertical load, the overdentures supported by three implant fixtures exhibited stress concentration on the supporting structure of the middle implant future. In overdentures supported by two or four implant futures, no significant difference was noted in stress distribution between the types of bars. These results indicate that the greater the number of implant fixtures, the better the stress distribution is. A favorable stress distribution may be obtained in the overdentures supported by two or three implant fixtures, if the location and the design of the bar are appropriate.

  • PDF

Accuracy of several implant bite registration techniques: an in-vitro pilot study

  • Park, Do-Hyun;Park, Ji-Man;Choi, Jae-Won;Kang, Eun-Sook;Bae, Eun-Bin;Jeon, Young-Chan;Jeong, Chang-Mo;Yun, Mi-Jung;Huh, Jung-Bo
    • The Journal of Advanced Prosthodontics
    • /
    • v.9 no.5
    • /
    • pp.341-349
    • /
    • 2017
  • PURPOSE. This study evaluated the accuracies of different bite registration techniques for implant-fixed prostheses using three dimensional file analysis. MATERIALS AND METHODS. Implant fixtures were placed on the mandibular right second premolar, and the first and second molar in a polyurethane model. Aluwax (A), Pattern Resin (P), and Blu-Mousse (B) were used as the bite registration materials on the healing abutments (H) or temporary abutments (T). The groups were classified into HA, HP, HB, TA, TP, and TB according to each combination. The group using the bite impression coping was the BC group; impression taking and bite registration were performed simultaneously. After impression and bite taking, the scan bodies were connected to the lab analogs of the casts. These casts were scanned using a model scanner. The distances between two reference points in three-dimensional files were measured in each group. One-way ANOVA and Duncan's test were used at the 5% significance level. RESULTS. The smallest distance discrepancy was observed in the TB group using the temporary abutments. The Blu-Mousse and HP groups showed the largest distance discrepancy. The TB and BC groups showed a lower distance discrepancy than the HP group (P=.001), and there was no significant difference between the groups using the temporary abutments and healing abutments (P>.05). CONCLUSION. Although this study has limitations as an in-vitro investigation, the groups using the temporary abutments to hold the Blu-Mousse record and bite impression coping showed greater accuracy than the group using the healing abutments to hold the pattern resin record.

TRAUMATIC BONE CYST : A CASE REPORT (외상성 골낭의 치험례)

  • Oh, Min-Hyung;Kim, Dae-Eop;Lee, Kwang-Hee
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.32 no.1
    • /
    • pp.18-25
    • /
    • 2005
  • Traumatic bone cyst is a nonodontogenic cyst without epithelial-linig which contains fluid in it's cavity, and it is limited by bone walls with no evidence of infection. Traumatic bone cyst is asymptomatic and appears more frequently in the second decade. Gender distribution is approximately equal, although males are affected slightly often than females. Radiographically the lesion shows a well demarcated radiolucent lesion of variable size and the lesion may have scalloped margins. The adjacent teeth to traumatic bone cyst remains vital. Traumatic bone cyst is usually treated by surgical exploration and currettage of the lesion. In the first case of this case report, the patient was refered from the local dental clinic for the radiolucent area under the left mandibular first molar. From the panorama radiograph at the first visit, the radiolucent area of the left mandible showed a well defined scalloped margin and identified as traumatic bone cyst. In the second case, the patient have visited for the chief complaint of swelling and abcess of right maxillary second premolar. In the radiographic check up with panorama radiograph, the radiolucent lesion with well demarcated scalloped margin was found in the right mandible body, and identified as traumatic bone cyst. In the first case, overinstrumentation was done through the mesial root canal to irrigate the lesion. In the second case, not any treatment was done, and watched the progression of the lesion. And in both cases, after two month, the radiolucency and the size of the lesion has decreased to show healing in progress.

  • PDF

THE MORPHOLOGIC CHARACTERISTICS OF CLASS I, NON-EXTRACTION PATIENTS (비발치로 치료된 I 급 부정교합의 형태적 특성)

  • Chang, Young-Il;Shin, Soo-Jung
    • The korean journal of orthodontics
    • /
    • v.28 no.3 s.68
    • /
    • pp.343-351
    • /
    • 1998
  • The purpose of this study was to investigate the pretreatment and posttreatment dentofacial characteristics of non-extraction patients with Class I malocclusion. And to compare this result with matched non-orthodontic normal occlusion and Class I premolar extraction patients. Such comparison might help identify morphologic characteristics of the non-extraction patients. Initial and final cephalometric evaluation were compared in a sample of 22 patients with Class I malocclusions treated in non-extraction manner with edgewise appliance and MEAW The mean age of the total population was 14 years 9 months and the average treatment time was 2 years 8 months. 32 landmarks were located and digitized on each cephalogram. From these landmarks, 24 linear and angular dimension were obtained. Student's t-test were used to compare the pretreatment - posttreatment results, Nonextraction - Normal groups, and nonextraction Extraction groups. Significance was predetermined at $p{\leq}0.05$. The results were as follows. 1. Before treatment, the mean value of the $ODI\;was\;69.9^{\circ},\;APDI\;was\;82.1^{\circ},\;CF\;was\;152^{\circ},\;EI\;was\;152^{\circ}$ in the non-extraction groups. 2. The skeletal pattern of the non-extraction groups were similar with non-orthodontic normal groupsr, but the non-extraction groups had larger interincisal angle. 3. Comparison between groups treated with and without extraction indicated at pretreatment, the extraction groups had more protrusive lips, smaller interincisal angle, and EI. 4. After treatment, there was no significant changes in the skeletal pattern of the non-extraction groups, but uprighting of the maxillary and mandibular first molar and decrease of the interincisal angle were seen.

  • PDF

FLEXURAL STRENGTH OF IMPLANT FIXED PROSTHESIS USING FIBER REINFORCED COMPOSITE (섬유성 강화 컴포지트를 사용한 임플랜트 고정성 보철물의 굴곡강도)

  • Kang, Kyung-Hee;Kwon, Kung-Rock;Lee, Sung-Bok;Choi, Dae-Gyun
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.44 no.5
    • /
    • pp.526-536
    • /
    • 2006
  • Statement of problem : Use of fiber composite technology as well as development of nonmetal implant prosthesis solved many problems due to metal alloy substructure such as corrosion. toxicity, difficult casting, expensiveness and esthetic limit. After clinical and laboratory test, we could find out that fiber-reinforced composite prostheses have good mechanical properties and FRC can make metal-free implant prostheses successful. Purpose : The purpose of this study is to evaluate the flexural strength of implant fixed prosthesis using fiber reinforced composite. Material and methods : 2-implant fixture were placed in second premolar and second molar area in edentulous mandibular model, and their abutments were placed, and bridge prostheses using gold, PFG, Tescera, and Targis Vectris were fabricated. Tescera was made in 5 different designs with different supplements. Group I was composed by 3 bars with diameter 1.0mm and 5 meshes, 2 bars and 5 meshes for Group II, 1 bar and 5 meshes for Group III, and only 5 meshes were used for Group IV. And Group V is composed by only 3 bars. Resin (Tescera) facing was made to buccal part of pontic of gold bridge. All of gold and PFG bridges were made on one model, 5 Targis Vectris bridges were also made on one model, and 25 Tescera bridges were. made on 3 models. Each bridge was attached to the test model by temporary cement and shallow depression was formed near central fossa of the bridge pontic to let 5 mm metal ball not move. Flexual strength was marked in graph by INSTRON. Results : The results of the study are as follows. The initial crack strength was the highest on PFG. and in order of gold bridge Tescera I, Tescera II, Targis vectris, Tescera IV, Tescera III, and Tescera V. The maximum strength was the highest on gold bridge, and in order of PFG, Tescera I, Tescera IV Tescera II, Targis vectris, Tescera III, and Tescera V. Conculsions : The following conclusions were drawn from the results of this study. 1. Flextural strength of implant prosthesis using fiber reinforced composite was higher than average posterior occlusal force. 2. In initial crack strength, Tescera I was stronger than Tescera V, and weaker than PFG. 3. Kinds and number of auxillary components had an effect on maximum strength, and maximum strength was increased as number of auxillary components increased. 4 Maximum strength of Tescera I was higher than Targis vectris, and lower than PFG.