• Title/Summary/Keyword: maintenance expense

Search Result 114, Processing Time 0.033 seconds

A study on the Collaboration Telemedicine Application System using the PACS (PACS를 이용한 상호참여형 원격진료 응용시스템 개발에 관한 연구)

  • 정세현;김석수
    • Journal of the Korea Society of Computer and Information
    • /
    • v.4 no.2
    • /
    • pp.80-87
    • /
    • 1999
  • We propose the various Telemedicine applications using collaborative PACS environment. Traditionally, almost all medical images have been printed on radiological films. These films are expensive to produce and easy to misplace and usually only one copy exists, thus limiting the number of persons who have simultaneous access to the images. But the merit of this system including PACS(Picture Archiving and Communications System ) is very many which are small depository, low maintenance expense, good efficience(storage, speed) and good flexibility but the development costs is higher. This research has been done creating multimedia-based Telemedicine system for home PCs in network environment. Most of Telemedicine used hardware and exclusive line of high cost as CATV broadcasting technique. But this system will contribute to change the Home-PC for better use of collaborations among doctor and patients through various modes of interactions in cyberspace.

  • PDF

The Extacting Crack in Asphalt Concrete Pavement by Digital Image Processing (수치영상처리에 의한 아스팔트 포장노면의 균열 검출)

  • Jang, Ji-Won
    • Journal of Korean Society for Geospatial Information Science
    • /
    • v.10 no.4 s.22
    • /
    • pp.77-84
    • /
    • 2002
  • Recently, damage of pavement represented by crack is depened by the increase of traffic demand up to ten million and wight, and interest about the efficient management of pavement is being increased gradually according to the growth of maintenance expense of road surface. In this study, the possibility of application for acquisition of crack information was tested by appling DCRP and digital image processing technique and measuring crack on road surface precisely. Based on this, objective and efficient road surface measurement was planned and done. Measuring crack width, acquire result of comparative high accuracy. So, it is considered that it can be utilized as plan draft data for deterioration estimation and repair reinforcement work of pavement.

  • PDF

A Study on the Safety Estimation of Table Liner for Vertical Roller Mill Using HDM (구멍뚫기법을 이용한 수직형 롤러 분쇄기용 테이블 라이너의 안전성 평가에 관한 연구)

  • Lee Dong Woo;Hong Soon Hyeok;Cho Seok Swoo;Joo Won Sik
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.28 no.8 s.227
    • /
    • pp.1221-1228
    • /
    • 2004
  • The vertical roller mill is the important machine grinding and mixing various crude materials in the manufacturing process of portland cement. Table liner is one of grinding elements of vertical roller mill and is subjected to the cyclic bending stress by rollers load and the centrifugal force by rotation of table. It demands $4{\times}10^7$ cycle but has $4{\times}10^6{\sim}8{\times}10^6$ cycle. It fractures at the edge of grinding path of outside roller. The repair expense for it amounts to $30\%$ of total maintenance of vertical roller mill. Therefore, this study shows the fracture mechanism of table liner for vertical roller mill using HDM and fatigue analysis and makes the estimation for safety of vertical roller mill.

Methods to System Integration in Distributed Heterogeneous Environments (분산 이기종 환경에서의 메시지미들웨어(MOM) 시스템 통합방안 연구)

  • Kim Jong-Bae;Song Jae-Young;Rhew Sung-Yul
    • Journal of Digital Contents Society
    • /
    • v.6 no.3
    • /
    • pp.163-168
    • /
    • 2005
  • Computing infrastructures and technologies are moving into the distributed environments. Due to increase of M&A, and outsourcing processes, or increase or development of various system in an organizations, there are various problems resing such as difficulties in maintenance and repairment, repetition or inconsistency of data, and lacks of interconnection between different of difficulties in financing and selecting an adequate solutionas. This study presents a method to integrate systems adopting massage middleware as an efficient alternative for integration of applications and data between different models under distributed system environments. We expect that the integration method presented in this study, adopting massage middleware between system, will be an efficient alternative to build up interface between small system in terms of expense and efficiency.

  • PDF

Building of Remote Control System for Lighthouse Based on CDMA (CDMA 기반 등대 원격 제어 시스템의 구축)

  • Kwon, Hyuk-Dong;Seo, Ki-Yeol;Park, Gyei-Kark
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.10 no.1 s.20
    • /
    • pp.9-14
    • /
    • 2004
  • Many lighthouses have been built for safety navigation of vessel, but the management of lighthouses had to paid for maintenance costs. For that reason, the remote control system for the lighthouse is to be used, but the communication expense is very expensive because of the use of satellite communication network or the RF communication network Also, the state of lighthouse is difficult to analyze as transmit only measured data. Therefore, this paper embodied the remote control system for the lighthouse using CDMA method, that was extended to island area and we verified the effectiveness of the proposed system.

  • PDF

Investigation of the Effect of Wear Particles on the Acoustic Emission Signal (마모 입자가 음향방출신호에 미치는 영향에 관한 연구)

  • Han, Jae-Ho;Shin, Dong-Gap;Kim, Dae-Eun
    • Tribology and Lubricants
    • /
    • v.35 no.5
    • /
    • pp.317-322
    • /
    • 2019
  • In spite of progress in tribological research, machine component failure due to friction and wear has been reported frequently. This failure may lead to secondary damage that can cause huge expense for maintenance and repair. To prevent economic loss, it is important to detect and predict the initial failure point. In this sense, various researchers have been tried to develop Condition Monitoring (CM) method using Acoustic Emission (AE) generated while the materials undergo failure. In this study, effect of particles on friction and wear was investigated using the pin-on-plate friction test and AE signal was recorded with a band-width type AE sensor. The experiments were performed in dry and lubricant conditions using steel and glass as specimens. After the experiment, 3D laser microscope image was captured to evaluate the wear behavior quantitatively. The AE signal was analyzed in time-domain and frequency-domain. The amplitude was compared with the frictional results. The results of this study showed that particle generation accelerate wear, generate high magnitude AE signal and change the frequency characteristics of the signal. Also, lubricant condition test results showed low coefficient of friction, low wear rate, and low magnitude of AE signal compared to the dry condition. It is expected that the results of this study will aid in better assessment of wear in CM technology

Change analysis with A.C of D.C electric railway (직류 전기철도의 교류화 분석)

  • Kim, Youn-Sik;Lee, Gi-Seung;Sim, Jae-Suk
    • Proceedings of the KSR Conference
    • /
    • 2008.11b
    • /
    • pp.151-156
    • /
    • 2008
  • The after 1974 capital region electric railroad is opened to traffic Koraill and Seoul metro adopt each other different power supply method and they operate and they are come. AC 25[kv] method voltage the insulation becomes larger standing distance highly, the case tunnel section which will introduce in the underground segment becomes on a large scale and the cost of construction increases to the city center and the underground segment adoption of DC method was many. To recent times with R-bar (Rigid-bar) introductions change of tunnel section the introduction of AC method came to be easy without in the underground segment. Operates sees in the electric protection where the Seoul metro and the Korail are different each other and, from the dead section segment the interior electric light to put out lights the passenger brings about inconveniently and the civil appeal which demands a power supply method unification occurs, within the company interchange electric railroad brazier safety improvement and maintenance expense curtailment etc. the flaw is original proposal, is a condition which finishes a feasibility study service about the power supply method fringe land. Interchange analysis of the DC electric railway it leads from the present paper and it compares under analyzing being it could be reflected to also the route which is in the process of actual using boil the strong point and a weak point of DC and AC method of the establishment route constructive at the time of and

  • PDF

Object Dimension Estimation for Remote Visual Inspection in Borescope Systems

  • Kim, Hyun-Sik;Park, Yong-Suk
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • v.13 no.8
    • /
    • pp.4160-4173
    • /
    • 2019
  • Borescopes facilitate the inspection of areas inside machines and systems that are not directly accessible for visual inspection. They offer real-time, up-close access to confined and hard-to-access spaces without having to dismantle or destructure the object under inspection. Borescopes are ideal instruments for routine maintenance, quality inspection and monitoring of systems and structures. The main application being fault or defect detection, it is useful to have measuring capability to quantify object dimensions in a target area. High-end borescopes use multi-optic solutions to provide measurement information of viewed objects. Multi-optic solutions can provide accurate measurements at the expense of structural complexity and cost increase. Measuring functionality is often unavailable in low-end, single camera borescopes. In this paper, a single camera measurement solution that enables the size estimation of viewed objects is proposed. The proposed solution computes and overlays a scaled grid of known spacing value over the screen view, enabling the human inspector to estimate the size of the objects in view. The proposed method provides a simple means of measurement that is applicable to low-end borescopes with no built-in measurement capability.

Functional Analysis of a Gene Encoding Endoglucanase that Belongs to Glycosyl Hydrolase Family 12 from the Brown-Rot Basidiomycete Fomitopsis palustris

  • Song, Byeong-Cheol;Kim, Ki-Yeon;Yoon, Jeong-Jun;Sim, Se-Hoon;Lee, Kang-Seok;Kim, Yeong-Suk;Kim, Young-Kyoon;Cha, Chang-Jun
    • Journal of Microbiology and Biotechnology
    • /
    • v.18 no.3
    • /
    • pp.404-409
    • /
    • 2008
  • The brown-rot basidiomycete Fomitopsis palustris is known to degrade crystalline cellulose (Avicel) and produce three major cellulases, exoglucanases, endoglucanases, and ${\beta}$-glucosidases. A gene encoding endoglucanase, designated as cel12, was cloned from total RNA prepared from F. palustris grown at the expense of Avicel. The gene encoding Cel12 has an open reading frame of 732 bp, encoding a putative protein of 244 amino acid residues with a putative signal peptide residing at the first 18 amino acid residues of the N-terminus of the protein. Sequence analysis of Cel12 identified three consensus regions, which are highly conserved among fungal cellulases belonging to GH family 12. However, a cellulose-binding domain was not found in Cel12, like other GH family 12 fungal cellulases. Northern blot analysis showed a dramatic increase of cel12 mRNA levels in F. palustris cells cultivated on Avicel from the early to late stages of growth and the maintenance of a high level of expression in the late stage, suggesting that Cel12 takes a significant part in endoglucanase activity throughout the growth of F. palustris. Adventitious expression of cel12 in the yeast Pichia pastoris successfully produced the recombinant protein that exhibited endoglucanase activity with carboxymethyl cellulose, but not with crystalline cellulose, suggesting that the enzyme is not a processive endoglucanase unlike two other endoglucanases previously identified in F. palustris.

A Comparative Analysis of Domestic and Foreign Universities' Facility Management for Green Campus - Focusing on the Energy Management - (그린캠퍼스를 위한 국내.외 대학시설관리(FM) 비교분석 - 에너지관리 중심 -)

  • Shin, Eun-Young;Kim, Jun-Ha
    • Journal of the Korean Institute of Educational Facilities
    • /
    • v.19 no.1
    • /
    • pp.45-53
    • /
    • 2012
  • Recently, as the environment issue has been stand out, people's interests in energy consumption of the building have been increased as well. Especially, university has been classified as the one of the main causes of excessive energy consumption. Therefore, domestic and foreign universities are trying to build a green campus in an attempt for sustainable development. Since early 2000s, foreign universities have been aware that one of the main causes of global warming is an excessive consumption of energy in universities. Accordingly, they adopted various energy management programs for the conservation. Ultimately, enforcing energy conservation and using alternative energy resulted in lower expense and it was a great help for the universities. On the other hand, excessive consumption of energy in domestic universities has been considered as serious, which led them to become the second main energy consumers in 2010. However, it seems people do not truly recognize the impotance of energy management, therefore, relatively little attention has been paid to this matter. Based on Leadership in Energy & Environmental Design(LEED) rating systems for on-campus building operation and maintenance, this research suggests the evaluation standard to effectively analyze the energy management activity with the best practices conducted in foreign universities and to solve the problem of campus facilities management in domestic universities. The result shows that domestic universities do not have a designated task force for effective energy management and the lack of energy professionals hinders for the long term development. Therefore, domestic universities should recognize the seriousness of the excessive energy consumption and develop low carbon green campus through proactive management practices since this is very essential for domestic universities to get more competitive in this global era.