• Title/Summary/Keyword: main controller

Search Result 953, Processing Time 0.022 seconds

Comparison of Starting Current Characteristics for Three-Phase Induction Motor Due to Phase-control Soft Starter and Asynchronous PWM AC Chopper

  • Thanyaphirak, Veera;Kinnares, Vijit;Kunakorn, Anantawat
    • Journal of Electrical Engineering and Technology
    • /
    • v.12 no.3
    • /
    • pp.1090-1100
    • /
    • 2017
  • This paper presents the comparison of starting current characteristics of a three-phase induction motor fed by two types of soft starters. The first soft starter under investigation is a conventional AC voltage controller on the basis of a phase-control technique. The other is the proposed asynchronous PWM AC chopper which is developed from the conventional synchronous PWM AC chopper. In this paper, the proposed asynchronous PWM AC chopper control scheme is developed by generating only two asynchronous PWM signals for a three-phase main power circuit (6 switching devices) from a single voltage control signal which is compared with a single sawtooth carrier signal. By this approach, the PWM signals are independent and easy to implement since the PWM signals do not need to be synchronized with a three-phase voltage source. Details of both soft starters are discussed. The experimental and simulation results of the starting currents are shown. It is found that the asynchronous PWM AC chopper efficiently works as a suitable soft starter for the three-phase induction motor due to that the starting currents are reduced and are sinusoidal with less harmonic contents, when being compared with the starting current waveforms using the conventional phase-control starting technique. Also the proposed soft starter offers low starting electromagnetic torque pulsation.

New hysteresis current control for induction motor drive with NPC inverter (NPC 인버터에 의한 유도전동기 구동시스템의 새로운 히스테리시스 전류 제어기법)

  • 김춘삼;이병송
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.13 no.1
    • /
    • pp.46-52
    • /
    • 1999
  • A new current controlled PWM t'||'&'||'pound;rlmique with NPC(Neutral Point Qarll)ed) structure is IrOIX>Sed in this paper. A current controlled PWM technique with neutral-JXlint-cIamped pulse-width modulation inverter composed of main switching devices which operates as switch for PWM and auxiliary switching devices to clamp the output terminal potential to the neutral point potential is described. The proposed current controller has a first and second current band The switching pattern will be made by the first current band. According to the second current band, the output state of the switching pattern is changed into positivee and negative state. This inverter output contains less hanronic content and lower switching frequency than that of conventional current controlled PWM technique at the same current limit. Thbe induction machine drive with proposed technique is investigated by commputer simulation.

  • PDF

Robust Tracking and Human-Compliance Control Using Integral SMC and DOB (적분슬라이딩모드와 DOB를 이용한 강인추종 및 인간순응 로봇제어)

  • Asignacion Jr., Abner;Kim, Min-chan;Kwak, Gun-Pyong;Park, Seung-kyu
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.21 no.2
    • /
    • pp.416-422
    • /
    • 2017
  • The robot control with safety consideration is required since robots and human work together in the same space more frequently in these days. For safety, robots must have compliance to human force and robust tracking performance with high impednace for the nonhuman disturbances. The novel idea is proposed to achieve the compliance and high impedance with one controller structure. For the compliance, the ISMC(Integral Sliding Mode Control) and HDOB(Human Disturbance Observer) The human force is identified by using the human band pass filter and its output is sent to the sliding surface. The sliding mode dynamic is affected by human disturbance and the compliance for human is achieved. The disturbances besides human frequencies are decoupled by the ISMC and the robust tracking is achieved. The additional LDOB(Low Frequency Disturbance Observer) decreases the maxim nonlinear gain and leads low chattering. The introduction of human disturbance into the sliding mode dynamic is the main novel idea of this paper.

PLL Control Method for Precise Speed Control of Slotless PM Brushless DC Motor Using 2 Hall-ICs (2 Hall-ICs를 이용한 Slotless PM Brushless DC Motor의 정밀속도제어를 위한 PLL 제어방식)

  • Yoon Y.H;Lee S.J;Kim Y.R;Won C.Y;Choe Y.Y
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.10 no.2
    • /
    • pp.109-116
    • /
    • 2005
  • The high performance drives of the slotless Permanent Magnet Brushless DC(PM BLDC) motor can be achieved by the current control, where the currents flow according to the rotor position and the current phase is suitably controlled according to the operational condition. Rotor position information can be provided by Hall-IC or sensorless algorithm. So, the Hall-ICs are set up in this motor to detect the main flux from the rotor. Instead of using three Hall-ICs and encoder, this paper uses only two Hall-ICs for the permanent magnet rotor position and the speed feedback signals, and uses a micro-controller of 16-bit type (80C196KC). Also because of low resolution obtained by using Hall-IC even low-cost and simple structure, to improve the wide range of speed response characteristic more exactly, we propose the rotor position signal synthesizer using PLL circuit based on two Hall-ICs.

Stable Standby-mode Implementation of Multi-output Power Supply using a New Load Current Estimation Technique with Linear Regulator (다중 출력 전원공급장치의 안정적 대기전력 구현을 위한 새로운 방식의 부하전류 측정기법 구현)

  • Lee, Jong-Hyun;Jung, An-Yeol;Kim, Dong-Joon;Park, Joung-Hu;Jeon, Hee-Jong
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.16 no.1
    • /
    • pp.88-95
    • /
    • 2011
  • In this paper, a new standby-mode control method for multiple output switching-mode power-supply is suggested, which uses the control signal of the feedback compensator of the inner loop in the linear voltage regulator located at the transformer secondary side, as the load current information. Conventional method has a problem that standby mode occurs depending only on the load condition of the main controller output, which makes the other secondary side output very inaccurate by burst mode operation. The proposed method detects all the load current information and operates in burst mode only when the all of them are light load condition. Minimum of the additional components are required for the implementation of the proposed method because the load information is obtained from the existing feedback circuit of the post-stage linear regulator. In this paper, the operating principles of the proposed standby-mode circuit are presented with an numerical analysis, and are verified by 25W hardware prototype implementation.

A Study on the Synchronization Methodology for Grid-connection of Three Phase Inverter (3상 인버터의 계통 연계를 위한 동기화 방법론에 대한 연구)

  • Lim, Byeong-Seok;Lee, Joon-Seong;Nguyen, Hoang-Nhan;Tran, Van-Thanh;Ko, Yun-Seok
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.14 no.5
    • /
    • pp.951-958
    • /
    • 2019
  • For the power grid-connection of distributed generation, the output voltage of the distributed generation must be synchronized with the grid voltage before the grid-connection. In this paper, a vector control based synchronization algorithm was developed for grid linkage of three-phase inverters. A three-phase voltage inverter was designed and fabricated to verify the effectiveness of the developed algorithm. The main controller of the three-phase inverter was developed based on DSP, and the electrical level of the system was set to an electrical level that can be tested in the laboratory. Throughout the experiments, it was confirmed that the proposed algorithm could be used as a synchronization algorithm for grid-connection by showing that the output voltage of the three-phase inverter is synchronized with the grid voltage.

The Development of Infant Smart Incubator for Home use (가정용 영유아 스마트 인큐베이터 개발)

  • Eum, Sang-Hee
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.24 no.10
    • /
    • pp.1325-1330
    • /
    • 2020
  • New-born babies who require special attention medically are admitted often to incubator. Incubators are well equipped to fulfill take care of infants, but they have to hospital and so expensive. This paper proposes a smart incubator that can solve the problem of convenience and cost aspect of these incubators. Developed incubator enables near-field monitoring using Arduino Uno as the main control device and Bluetooth communication. The environment in the incubator measures temperature and humidity using a DHT22 sensor and the sound using a P5510 microphone. If the temperature and humidity data set by the user are lower or higher than the reference value, it is designed to operate the heating pad using the controller or turn on the fan to allow air circulation. The measured values in the incubator are displayed in real time on the user's smartphone monitoring screen and are programmed using app inventor. Developed incubators can help take care of infants at low cost in the home.

Design and Pressure Loss Evaluation of Vacuum Brazed Cooling Passage for Full Authority Digital Engine Control (항공기용 엔진제어기의 진공 브레이징 냉각유로 설계 및 압력손실 평가)

  • Han, Myeongjae;Seol, Jinwoon;Jeong, Seungho;Cha, Minkyung;Jang, Hoyoun;Kim, Junghoe
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.26 no.2
    • /
    • pp.72-78
    • /
    • 2022
  • A vacuum brazed cooling passage for an aircraft engine controller was designed. In order to predict the total pressure loss, which is the main design factor of the cooling passage, theoretical and numerical methods for the major loss and the minor loss considering the overall shape of the cooling passage are presented. This design and evaluation method can predict the pressure loss of the complex cooling passage shape for various flow conditions at the initial design step.

Experimental Evaluation of Seismic Response Control Performance of Smart TMD (스마트 TMD의 지진응답 제어성능 실험적 검토)

  • Kang, Joo-Won;Kim, Hyun-Su
    • Journal of Korean Association for Spatial Structures
    • /
    • v.22 no.3
    • /
    • pp.49-56
    • /
    • 2022
  • Tuned mass damper (TMD) is widely used to reduce dynamic responses of structures subjected to earthquake loads. A smart tuned mass damper (STMD) was proposed to increase control performance of a traditional passive TMD. A lot of research was conducted to investigate the control performance of a STMD based on analytical method. Experimental study of evaluation of control performance of a STMD was not widely conducted to date. Therefore, seismic response reduction capacity of a STMD was experimentally investigated in this study. For this purpose, a STMD was manufactured using an MR (magnetorheological) damper. A simple structure presenting dynamic characteristics of spacial roof structure was made as a test structure. A STMD was made to control vertical responses of the test structure. Two artificial ground motions and a resonance harmonic load were selected as experimental seismic excitations. Shaking table test was conducted to evaluate control performance of a STMD. Control algorithms are one of main factors affect control performance of a STMD. In this study, a groundhook algorithm that is a traditional semi-active control algorithm was selected. And fuzzy logic controller (FLC) was used to control a STMD. The FLC was optimized by multi-objective genetic algorithm. The experimental results presented that the TMD can effectively reduce seismic responses of the example structures subjected to various excitations. It was also experimentally shown that the STMD can more effectively reduce seismic responses of the example structures conpared to the passive TMD.

Analysis of Engine Load Factor for a 78 kW Class Agricultural Tractor According to Agricultural Operations (농작업에 따른 78 kW급 농업용 트랙터 엔진 부하율 분석)

  • Baek, Seung Min;Kim, Wan Soo;Baek, Seung Yun;Jeon, Hyeon Ho;Lee, Dae Hyun;Kim, Hyung Kweon;Kim, Yong Joo
    • Journal of Drive and Control
    • /
    • v.19 no.1
    • /
    • pp.16-25
    • /
    • 2022
  • The purpose of this study was to calculate and analyze the engine load factor of major agricultural operations using a 78 kW class agricultural tractor for estimating the emission of air pollutants and greenhouse. Engine load data were collected using controller area network (CAN) communication. Main agricultural operations were selected as plow tillage (PT), rotary tillage (RT), baler operation (BO), loader operation (LO), driving on soil (DS), and driving on concrete (DC). The engine power was calculated using the measured engine load data. A weight factor was applied to load factor for considering usage ratio according to agricultural operations. Weight factors for different agricultural operations were calculated to be 27.4%, 32.9%, 17.5%, 7.7%, 4.5%, and 10.0% for PT, RT, BO, LO, DS, and DC, respectively. As a result of the field test, load factors were 0.74, 0.93, 0.41, 0.23, 0.27, and 0.21 for PT, RT, BO, LO, DS, and DC, respectively. The engine load factor was the highest for RT. Finally, as a result of applying the weight factor for usage ratio of agricultural operations, the integrated engine load factor was estimated to be 0.63, which was about 1.31 times higher than the conventional applied load factor of 0.48. In future studies, we plan to analyze the engine load factor by considering various horsepower and working conditions of the tractor.