• Title/Summary/Keyword: magnitude

Search Result 8,049, Processing Time 0.038 seconds

Estimating urinary energy value of rat from the urinary nitrogen content (쥐의 뇨질소함량(尿窒素含量)으로부터 뇨(尿) Energy 가(價)의 산출법(算出法))

  • Han, In-K.
    • Applied Biological Chemistry
    • /
    • v.7
    • /
    • pp.29-33
    • /
    • 1966
  • This experiment was conducted to study the relationship between the energy value and the nitrogen content in the rat urine. Thirteen rats for ad libitum feeding group and 16 rats for two-meal group were employed in this experiment. The experimental period consisted of 22 days with a preliminary period of 10 days. During the last eight days of the experiment the urine was collected quantitatively. The rats fed two-meal per day excreted significantly (p<0.005) more nitrogen and energy in the urine than those fed ad libitum. A linear relationship between the energy concentration and nitrogen content was found. The urinary energy value was increased as the urinary nitrogen content was increased. A prediction equation was derived to compute the energy value from the content of nitrogen as follows: Y=8.924X+0.182 $S_{y{\cdot}x}=0.788$ where Y=urinary energy(kcal/100 ml) X=urinary nitrogen(gm/100 ml) Since the standard deviation of estimate is in small magnitude (0.788 kcal) when it is compared with the amount of intake of gross energy, digestible energy or metabolizable energy, this equation can be used safely to estimate the energy value from nitrogen content. Consequently, considerable amound of time and labor for the actual determination of energy can be saved. The ratio of energy to nitrogen was found to be 9.4 for ad adlibitum group and 8.6 for two-meal group. No significant difference between two group in this respect was observed.

  • PDF

A Study on the Interpretalion of the Synthetic Unit Hydrograph According to the Characteristics of catchment Area and Runoff Routing (유역 특성과 유출추적에 의한 단위도 해석에 관한 고찰)

  • 서승덕
    • Magazine of the Korean Society of Agricultural Engineers
    • /
    • v.8 no.1
    • /
    • pp.1088-1096
    • /
    • 1966
  • The following is a method of synthetic unitgraph derivation based on the routing of a time area diagram through channel storage, studied by Clark-Jonstone and Laurenson. Unithy drograph (or unitgraph) is the hydrograph that would result from unit rainfall\ulcorner excess occuring uniformly with respect to both time and area over a catchment in unit time. By thus standarzing rainfall characteristics and ignoring loss, the unitgraph represents only the effects of catchment characteristics on the time distribution of runoff from a catchment The situation abten arises where it is desirable to derive a unitgraph for the design of dams, large bridge, and flood mitigation works such as levees, floodways and other flood control structures, and are also used in flood forecasting, and the necessary hydrologie records are not available. In such cases, if time and funds permit, it may be desirable to install the necessary raingauges, pruviometers, and stream gaging stations, and collect the necessary data over a period of years. On the otherhand, this procedure may be found either uneconomic or impossible on the grounds of time required, and it then becomes necessary to synthesise a unitgraph from a knowledge of the physical charcteristics of the catchment. In the preparing the approach to the solution of the problem we must select a number of catchment characteristic(shape, stream pattern, surface slope, and stream slope, etc.), a number of parameters that will define the magnitude and shape of the unit graph (e.g. peak discharge, time to peak, and base length, etc.), evaluate the catch-ment characteristics and unitgraph parameters selected, for a number of catchments having adequate rainfall and stream data and obtain Correlations between the two classes of data, and assume the relationships derived in just above question apply to other, ungaged, Catchments in the same region and, knowing the physical characteritics of these catchments, substitute for them in the relation\ulcorner ships to determine the corresponding unitgraph parameters. This method described in this note, based on the routing of a time area diagram through channel storage, appears to provide a logical line of research and they allow a readier correlation of unitgraph parameters with catchment characteristics. The main disadvantage of this method appears to be the error in routing all elements of rainfall excess through the same amount of storage. evertheless, it should be noted that the synthetic unitgraph method is more accurate than the rational method since it takes account of the shape and tophography of the catchment, channel storage, and temporal variation of rainfall excess, all of which are neglected in rational method.

  • PDF

An Experimental Study for Longitudinal Resistance of Ballast Track on Bridge (교량 상 자갈궤도의 종저항력 측정을 위한 실험 연구)

  • Min, Kyung-Hwan;Yun, Kyung-Min
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.17 no.5
    • /
    • pp.173-178
    • /
    • 2016
  • When a ballast track of a high-speed train is constructed on a bridge, the displacement of the bridge decks can occur because they are not fixed to the rails. Moreover, relative displacements occur between the bridge and rails caused by temperature changes and external loads. The current longitudinal resistance criteria (UIC Code 774-3, KR C-08080) on ballast tracks with continuous welded rails (CWRs) do not take into account the longitudinal movement of the bridge and the frictional force between the ballast and slabs. In addition, the magnitude of the longitudinal resistance, k, is calculated somewhat conservatively and, (therefore?) it acts as an unfavorable element in the design of long span and continuous railway bridges. Thus, in order to replicate the actual behavior more effectively, the longitudinal resistance of CWRs should take into account the additional rigidity between the slab and track. In this study, the longitudinal resistances of the ballasted track on the bridge were analyzed by carrying out an experimental study with a test setup designed to simulate the deck and bed track. In the test results, the maximum longitudinal resistances of the tests were similar to the resistances of the current codes, however, the measured longitudinal stiffness designed to limit the displacement of the tests were much smaller in comparison with the longitudinal stiffness on the codes.

Modeling and Strategic Startup Scheme for Large-Scaled Induction Motors (대용량 유도기 기동 특성 모델링 및 전략적 기동 방법에 관한 연구)

  • Jung, Won-Wook;Shin, Dong-Yeol;Lee, Hak-Ju;Yoon, Gi-Gab
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.8 no.4
    • /
    • pp.748-757
    • /
    • 2007
  • This paper is intended to solve the technical problem that fails in large-capacity induction motor starting due to serious voltage drop during starting period. One induction motor that is established already can reach in steady-state using reactor starting method but the voltage magnitude of PCC (point of common coupling) has dropped down a little. When the same capacity induction motor is installed additionally in the PCC, where the existing induction motor is operating, voltage drop becomes more serious by starting of additional induction motor. As a result, the additional induction motor fails in starting. Therefore, voltage compensation method is proposed so that all of two induction motors can be started completely. First, modeling technique is described in order to implement starting characteristics of large induction motor. And then, this paper proposes strategic starting scheme by proper voltage compensation that use no-load transformer tap control (NLTC) and step voltage regulator (SVR) for starting of two large induction motors successfully and improving the feeding network voltage profile during the starting period. The induction motor discussed in this paper is the pumped induction motor of 2500kVA capacity that is operating by KOWACO (Korea Water Resources Corporation). Modeling and simulation is conducted using PSCAD/EMTDC software.

  • PDF

Performance Evaluation of Hash Join Algorithm on Flash Memory SSDs (플래쉬 메모리 SSD 기반 해쉬 조인 알고리즘의 성능 평가)

  • Park, Jang-Woo;Park, Sang-Shin;Lee, Sang-Won;Park, Chan-Ik
    • Journal of KIISE:Computing Practices and Letters
    • /
    • v.16 no.11
    • /
    • pp.1031-1040
    • /
    • 2010
  • Hash join is one of the core algorithms in databases management systems. If a hash join cannot complete in one-pass because the available memory is insufficient (i.e., hash table overflow), however, it may incur a few sequential writes and excessive random reads. With harddisk as the tempoary storage for hash joins, the I/O time would be dominated by slow random reads in its probing phase. Meanwhile, flash memory based SSDs (flash SSDs) are becoming popular, and we will witness in the foreseeable future that flash SSDs replace harddisks in enterprise databases. In contrast to harddisk, flash SSD without any mechanical component has fast latency in random reads, and thus it can boost hash join performance. In this paper, we investigate several important and practical issues when flash SSD is used as tempoary storage for hash join. First, we reveal the va patterns of hash join in detail and explain why flash SSD can outperform harddisk by more than an order of magnitude. Second, we present and analyze the impact of cluster size (i.e., va unit in hash join) on performance. Finally, we emperically demonstrate that, while a commerical query optimizer is error-prone in predicting the execution time with harddisk as temporary storage, it can precisely estimate the execution time with flash SSD. In summary, we show that, when used as temporary storage for hash join, flash SSD will provide more reliable cost estimation as well as fast performance.

A Study of Evaluation Indices for Selecting Castle Remains Maintenance and Restoration Sections (성곽유적의 정비복원(整備復元) 대상구간 선정을 위한 평가지표 연구)

  • Kim, Hong-Gon;Choi, Key-Soo
    • Journal of the Korean Institute of Traditional Landscape Architecture
    • /
    • v.30 no.1
    • /
    • pp.1-13
    • /
    • 2012
  • Most of all Castle Remains in Korea were built on an axis of development with a scale of great magnitude. Because of its characteristics, the restoration and conservation plans should be phased in over medium and long term. There is no standards for evaluating the value of Castle Remains to set up the restoration and conservation sections. Some plans were set up through the value evaluation of its Castle Remains but those plans didn't have Evaluation System and different weight depending on different environment between Sanseong(mountain fortress) and Eupsung(fortress built in villages). To solve the limitation of Evaluation System of Castle Remains, this study try to approach in the Evaluation System methodology for selecting restoration sections. The results of its study follow below. First, this study drew the Evaluation Indices for selecting restoration sections of Castle Remains. There are three kinds of Elements(upper Index) and nine kinds of Evaluations(low Index). Second, Calculation of weight index by index on the questionnaire survey from expers through the relative importance analysis of AHP. Third, This study suggests the specific Evaluation System according to types; Sanseong(mountain fortress) and Eupsung(fortress built in villages);. Therefore, this study suggests standards to select the priority list for the restoration and conservation plan process and it can be used one of important standards in future plans.

Operation Analysis of Resonant DC/DC Converter able to Harvest Thermoelectric Energy (열전에너지 수확이 가능한 공진형 DC/DC 컨버터의 동작 해석)

  • Kim, Hyeok-Jin;Chung, Gyo-Bum;Cho, Kwan-Youl;Choi, Jae-Ho
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.15 no.2
    • /
    • pp.150-158
    • /
    • 2010
  • The operational characteristics of a resonant DC/DC converter, which can harvest thermoelectric energy, is analyzed, depending on the relative magnitudes of the input voltage and the load voltage. The resonant converter consists of LC resonant circuit connected to DC input source and a resonant pulse converter in which the input energy is transferred to the load as the resonant capacitor voltage is peak. The resonant capacitor doubles the input voltage by the resonance phenomenon. By the relative magnitude between the input voltage and the output voltage, the resonant DC/DC converter operates in three different modes. For boost mode, the peak voltage of the resonant capacitor is smaller than the load voltage. For hybrid mode, the peak voltage of the resonant capacitor is bigger than the load voltage and every switching period has both the boost mode and the direct mode. For the direct mode, the input voltage is bigger than the load voltage and the converter transfers directly the input energy to the load without the switching operation. Operation principles and the feasibility of the converter for the thermoelectric energy harvesting are verified with PSPICE simulation and experiment.

Elimination of Redundant Input Information and Parameters during Neural Network Training (신경망 학습 과정중 불필요한 입력 정보 및 파라미터들의 제거)

  • Won, Yong-Gwan;Park, Gwang-Gyu
    • The Transactions of the Korea Information Processing Society
    • /
    • v.3 no.3
    • /
    • pp.439-448
    • /
    • 1996
  • Extraction and selection of the informative features play a central role in pattern recognition. This paper describes a modified back-propagation algorithm that performs selection of the informative features and trains a neural network simultaneously. The algorithm is mainly composed of three repetitive steps : training, connection pruning, and input unit elimination. Afer initial training, the connections that have small magnitude are first pruned. Any unit that has a small number of connections to the hidden units is deleted,which is equivalent to excluding the feature corresponding to that unit.If the error increases,the network is retraned,again followed by connection pruning and input unit elimination.As a result,the algorithm selects the most im-portant features in the measurement space without a transformation to another space.Also,the selected features are the most-informative ones for the classification,because feature selection is tightly coupled with the classifi-cation performance.This algorithm helps avoid measurement of redundant or less informative features,which may be expensive.Furthermore,the final network does not include redundant parameters,i.e.,weights and biases,that may cause degradation of classification performance.In applications,the algorithm preserves the most informative features and significantly reduces the dimension of the feature vectors whiout performance degradation.

  • PDF

Evaluation of Pollutants Concentrations and Runoff Characteristics in Highway Rest Area (국내 고속도로 휴게소지역 비점오염원 유출특성 분석)

  • Kim, Jeong-Hyun;Kang, Hee-Man;Ko, Seok-Oh
    • International Journal of Highway Engineering
    • /
    • v.12 no.4
    • /
    • pp.131-137
    • /
    • 2010
  • The stormwater runoff from rest areas in highways are known as more polluted compared to highways because of more vehicle activities. This study is performed to find pollutant characteristics in the rest areas in the magnitude of statistical pollutant concentrations during storms. Washoff characteristics of pollutants from rest areas by monitoring of rainfall, runoff rate and runoff samples were evaluated. High concentrations of pollutants in runoff were observed at the beginning of runoff and rapid decrease thereafter, indicating that first-flush effects are clearly occurred. Event Mean Concentrations(EMCs) of TSS, COD, TN, and TP are estimated to be in the range of 31.04-127.11mg/L, 35.5-369.5mg/L, 2.62-9.86 mg/L, and 0.53-1.96mg/L, respectively. Heavy metals in runoff showed relatively high values, possibly due to the abrasion of brake pad or tire while cars are slowly moving for parking. EMCs of total Pb, total Cu, and total Ni are in the range of $1206-16293{\mu}g/L$, $237-7906{\mu}g/L$, and $53-6372{\mu}g/L$, respectively. Pollutant loading per rest area calculated by using EMC, flowrate and target area is also described for each pollutant.

Design of High-Speed Multi-Layer PCB for Ultra High Definition Video Signals (UHD급 영상구현을 위한 다층인쇄회로기판의 특성 임피던스 분석에 관한 연구)

  • Jin, Jong-Ho;Son, Hui-Bae;Rhee, Young-Chul
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.19 no.7
    • /
    • pp.1639-1645
    • /
    • 2015
  • In UHD high-speed video transmission system, when a signal within certain frequency region coincides electrically and structurally, the system becomes unstable because the energy is concentrated, and signal flux is interfered and distorted. For the instability, power integrity analysis should be conducted. To remove the signal distortion for MLB, using a high-frequency design technique for EMI phenomenon, EMI which radiates electromagnetic energy fluxed into power layer was analyzed considering system stabilization. In this paper, we proposed an adaptive MLB design method which minimizes high-frequency noise in MLB structure, enhances signal integrity and power integrity, and suppresses EMI. The characteristic impedance for multi-layer circuit board proposed in this study were High-Speed Video Differential Signaling(HSVDS) line width w = 0.203, line gap d = 0.203, beta layer height h = 0.145, line thickness t = 0.0175, dielectric constant εr = 4.3, and characteristic impedance Zdiff = 100.186Ω. When high-speed video differential signal interface board was tested with optimized parameters, the magnitude of Eye diagram output was 672mV, jittering was 6.593ps, transmission frequency was 1.322GHz, signal to noise was 29.62dB showing transmission quality improvement of 10dB compared to previous system.