• Title/Summary/Keyword: magneto-current

Search Result 158, Processing Time 0.03 seconds

First-principles studies on mechanical, electronic, magnetic and optical properties of new multiferroic members BiLaFe2O6 and Bi2FeMnO6: Originated from BiFeO3

  • Tuersun, Yisimayili;Rouzhahong, Yilimiranmu;Maimaiti, Maihemuti;Salamu, Abidiguli;Xiaerding, Fuerkaiti;Mamat, Mamatrishat;Jing, Qun
    • Current Applied Physics
    • /
    • v.18 no.12
    • /
    • pp.1473-1479
    • /
    • 2018
  • Recently multiferroic materials have attract great interest for the applications on memorial, spintronic and magneto-electric sensor devices for their spontaneous magneto-electric coupling properties. Research and development of the various kinds of multiferroics are indispensable factor for a new generation multifunctional materials. In this research, mechanical, electronic, magnetic and nonlinear optical properties of La modified $BiLaFe_2O_6$ (BLFO) and Mn modified $Bi_2FeMnO_6$ (BFMO) were studied as new members of multiferroic $BiFeO_3$ (BFO) series by first-principles calculations, and compared with the pure BFO to discover the optimized properties. Our results show that BLFO and BFMO have good mechanical stability as revealed by elastic constants that satisfy the stability criteria. All these compounds exhibit anisotropic and ductile nature. The enhanced properties by La and Mn substitution, such as increased hardness, improved magnetism, decreased band gap and comparable second harmonic generation responses reveal that the new multiferroic members of BLFO and BFMO would get wider application than their BFO counterpart. Our study is expected to providing an appropriate mechanical reference data as guidance for engineering of high efficiency multifunctional devices with the BFO series.

SPACE WEATHER RESEARCH BASED ON GROUND GEOMAGNETIC DISTURBANCE DATA (지상지자기변화기록을 이용한 우주천기연구)

  • AHN BYUNG-HO
    • Publications of The Korean Astronomical Society
    • /
    • v.15 no.spc2
    • /
    • pp.1-13
    • /
    • 2000
  • Through the coupling between the near-earth space environment and the polar ionosphere via geomagnetic field lines, the variations occurred in the magnetosphere are transferred to the polar region. According to recent studies, however, the polar ionosphere reacts not only passively to such variations, but also plays active roles in modifying the near-earth space environment. So the study of the polar ionosphere in terms of geomagnetic disturbance becomes one of the major elements in space weather research. Although it is an indirect method, ground magnetic disturbance data can be used in estimating the ionospheric current distribution. By employing a realistic ionospheric conductivity model, it is further possible to obtain the distributions of electric potential, field-aligned current, Joule heating rate and energy injection rate associated with precipitating auroral particles and their energy spectra in a global scale with a high time resolution. Considering that the ground magnetic disturbances are recorded simultaneously over the entire polar region wherever magnetic station is located, we are able to separate temporal disturbances from spatial ones. On the other hand, satellite measurements are indispensible in the space weather research, since they provide us with in situ measurements. Unfortunately it is not easy to separate temporal variations from spatial ones specifically measured by a single satellite. To demonstrate the usefulness of ground magnetic disturbance data in space weather research, various ionospheric quantities are calculated through the KRM method, one of the magneto gram inversion methods. In particular, we attempt to show how these quantities depend on the ionospheric conductivity model employed.

  • PDF

A Study on the Current Measurement Using Spun Fiber (Spun 광섬유를 이용한 전류 측정에 관한 연구)

  • Kwon, Won-Hyun;Jeon, Suk-Hee;Kim, Young-Soo;Kim, Yo-Hee;Park, Han-Kyu
    • Journal of the Korean Institute of Telematics and Electronics
    • /
    • v.25 no.10
    • /
    • pp.1158-1165
    • /
    • 1988
  • In this paper, the polarization properties of spun fiber due to intrinsic birefringence and magneto-optic effects are theoretically analyzed and experimented. The degree of polarization which indicates the intrinsic birefrigence is measured over 0.818, and the variation of output polarization angle with input polarization angle is measured within 9$^{\circ}$. Compared with single mode fiber, spun fiber is found to have very excellent polarization-maintaining property. Implemented current measurement system using spun fiber can linearly measure the magnetic field up to 20,000 A/m generated by solenoid.

  • PDF

The controllable fluid dash pot damper performance

  • Samali, Bijan;Widjaja, Joko;Reizes, John
    • Smart Structures and Systems
    • /
    • v.2 no.3
    • /
    • pp.209-224
    • /
    • 2006
  • The use of smart dampers to optimally control the response of structures is on the increase. To maximize the potential use of such damper systems, their accurate modeling and assessment of their performance is of vital interest. In this study, the performance of a controllable fluid dashpot damper, in terms of damper forces, damper dynamic range and damping force hysteretic loops, respectively, is studied mathematically. The study employs a damper Bingham-Maxwell (BingMax) model whose mathematical formulation is developed using a Fourier series technique. The technique treats this one-dimensional Navier-Stokes's momentum equation as a linear superposition of initial-boundary value problems (IBVPs): boundary conditions, viscous term, constant Direct Current (DC) induced fluid plug and fluid inertial term. To hold the formulation applicable, the DC current level to the damper is supplied as discrete constants. The formulation and subsequent simulation are validated with experimental results of a commercially available magneto rheological (MR) dashpot damper (Lord model No's RD-1005-3) subjected to a sinusoidal stroke motion using a 'SCHENK' material testing machine in the Materials Laboratory at the University of Technology, Sydney.

A Study of the Hydraulic Circuit Model for a Magnetorheological Damper Analysis (MR 댐퍼 해석을 위한 유압회로 모델에 대한 연구)

  • Chang, Moon Suk;Byeon, Woo Jin;Kim, Soo Tae;An, Chae Hean
    • Journal of Drive and Control
    • /
    • v.14 no.1
    • /
    • pp.8-13
    • /
    • 2017
  • This paper proposes a hydraulic circuit for a Magnetorheological (MR) damper that can be used for semi-active and active controls. Methods are presented for obtaining reliable damping force displacement and velocity data, and hysteresis loop data corresponding to applied current. In order to get reliable data, analysis using electric and electronic software, a series of tests. and comparative evaluations are required. A hydraulic circuit model is proposed that can be applied to analyze a MR damper without any assumptions where the yield stress data according to the applied current are known. Analysis results of the proposed hydraulic circuit are confirmed by experimental results within acceptable tolerance. This hydraulic circuit model can be applied to various MR dampers and systems.

Design and Dynamic Analysis of Air-core Coil type Linear DC Motor (공심 코일형 리니어 DC 모터의 설계 및 동특성 해석)

  • Gang, Gyu-Hong;Hong, Jeong-Pyo;Kim, Gyu-Tak;Ha, Geun-Su;Jeong, Jung-Gi;Im, Tae-Bin
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.49 no.3
    • /
    • pp.165-171
    • /
    • 2000
  • This paper proposes a technique to design of air-core type Linear DC Motor(LDM) by using Equivalent Magnetizing Current(EMC) method and has performed its dynamic analysis. The magnetic flux density differ in accordance with airgap position due to difference of mechanical and magnetic air gap length and the coil shape has an influence on the thrust. Therefore, the analysis of magnetic field due to the magnets is carried out by EMC. The phenomena according to the various coil various coil shape under the same Magneto Motive Force(MMF) has been analyzed and its result is applied to the design process. The appropriateness of the proposed technique is confirmed by Finite Element Method(FEM) and its dynamic analysis is carried out from the coupling of the electrical circuit equation and mechanical kinetic equation.

  • PDF

Electromagnetic Analysis on the Torque Motor of Servo Valve for the Fuel Supply System of Auxiliary Power Unit (보조 동력 장치 연료 공급용 서보밸브의 토크모터 전자기 해석)

  • Chang, Se-Myong;Jang, Gang-Won;Jeong, Heon-Sul;Rhee, Dong-Ho
    • Journal of Aerospace System Engineering
    • /
    • v.1 no.3
    • /
    • pp.7-12
    • /
    • 2007
  • As a main part of an utility helicopter, the APU(Auxiliary Power Unit) has a solenoid valve system operated with a torque motor, which controls the flow rate in the fuel supply system. In this paper, we solved the Maxwell potential equations to analyze the electromagnetic force in the torque motor, and some additional analytic methods are used to compute the quantity of torque produced by the torque motor for the given circuit current. For the convenience, small displacement is assumed, and only magneto-static problem is considered for the two-dimensional cross section. The result will be compared with the three-dimensional analysis that will be studied in the near future.

  • PDF

Characterization of step-edge dc SQUID magnetometer fabricated on sapphire substrate (사파이어 기판 위에 제작된 step-edge dc SQUID magnetometer의 특성)

  • 임해용;박종혁;정구락;한택상;김인선;박용기
    • Proceedings of the Korea Institute of Applied Superconductivity and Cryogenics Conference
    • /
    • 2002.02a
    • /
    • pp.127-130
    • /
    • 2002
  • Step-edge dc SQUID magnetometers have been fabricated on sapphire substrate. Ce$O_{2}$ buffer layer and $YBa_{2}$$Cu_{3}$ $O_{7}$(YBCO) films were deposited in-situ on the low angle (~$35^{\circ}$)steps formed on the substrates. Typical 5-$\mu$m-wide junction has $R_{N}$ of 4 $\Omega$ and $I_{c}$ of 60 $\mu$A with $I_{c}$$R_{N}$ product of 240 $\mu$V at 77 K. According to applied bias current, depth of voltage modulation was changed and maximum voltage was measured 100~300 fT/$\checkmark$ Hz at 100 Hz, and about 1.5 pT/$\checkmark$ Hz at 1 Hz. For ac bias reversal method, field noise was decreased in the 1/f region. The QRS peak of magneto-cardiogram was measured 50 pT in the magnetically shielded room.

  • PDF

Consideration the Writing and Reproducting Pattern of Isolated Transition of Magnetization in Perpendicular Magnetic Recording System by using F.E.M. (유한요소법에 의한 수직자기기록장치의 단일자화반전기록 및 재생에 관한 고찰)

  • Lee, Hyang-Beom;Park, Gwan-Soo;Hahn, Song-Yop
    • Proceedings of the KIEE Conference
    • /
    • 1990.11a
    • /
    • pp.28-31
    • /
    • 1990
  • In perpendicular magnetic recording system, the magnetic recording and reproduction characteristics of isolated transition of magnetization is simulated in this paper. The recording system which is magneto-static system is analyzed using two-dimensional finite element method and the characteristics of hysteresis of recording media is considered. The results show that the optimizing current is exist in magnetic recording system.

  • PDF

Development of control algorism and magnetic analysis of a MR damper (작동기 구조해석 및 제어알고리즘 개발)

  • Park, C.S.;Song, S.S.;Lee, H.J.;Lee, J.J.;Hong, S.H.;Jo, H.M.
    • Proceedings of the KIEE Conference
    • /
    • 2008.04c
    • /
    • pp.254-256
    • /
    • 2008
  • In recent Year were many devices and facilities developed and manufactured. For guarantee of the property of the devices and facilities needs Vibration protecting Technique and the Technique will be developed more and more. Magneto-Rheological damper is one of the nice devices for reducing of Vibration. In this paper magnetic properties of a MR-damper which is developed for reducing of vibration in display manufacture devices will be analysed at variation different air-gap length and current.

  • PDF