• 제목/요약/키워드: magnetic treatment

검색결과 1,514건 처리시간 0.039초

Two Cases of Plantar Fasciitis Treated with Magnetic Acupuncture

  • Yun, Gee Won;Kang, Jae Hui;Oh, Seo Young;Park, Jung Hwan;Lee, Hyun
    • Journal of Acupuncture Research
    • /
    • 제34권1호
    • /
    • pp.89-96
    • /
    • 2017
  • Objectives : The aim of the study was to ascertain the effectiveness of magnetic acupuncture in patients with plantar fasciitis. Methods : The patients were treated with magnetic acupuncture using a magnetic therapy stimulator (Whata 153), as well as with moxibustion therapy. Acupuncture treatment was conducted on the acupoints of Ashi-as well as on 太谿 (KI3), 崑崙 (BL60), and 委中 (BL40)-for 15 minutes. The intensity of pain was evaluated using the visual analogue scale (VAS), and the tenderness threshold (TT) was measured at each visit using an algometer. Results : After treatment, evaluation using the VAS had improved, as had the TT; furthermore, plantar fasciitis pain was reduced. Conclusion : Magnetic acupuncture relieved pain in plantar fasciitis. In further clinical study, more research on magnetic acupuncture is required.

Development of Pocket Insertion style Magnetic Curer that Apply $2^{loop}\;3^{pulsed}$ Variable Magnetic type Probe for Urinary Treatment

  • Kim, Whi-Young
    • Journal of information and communication convergence engineering
    • /
    • 제6권1호
    • /
    • pp.73-79
    • /
    • 2008
  • Result that study magnet nerve curer for treatment induced current generation and current of ion for development in main point incontinence, prostate, sphincter, nervous system, rigidity, headache, retrogression arthritis, ligament damage, Rheumatism arthritis, peripheral nerve etc., can classify by 4. Embodied do first, full bridge magnet occurrence chapter, and communication with PC is available, confirmed various action loops an experiment. Could confirm correct treatment probe second, woman and man disease person. Third, derived so that healing may be possible naturally by addition of apron form according to disease. Because composition of finally, treatment probe composes by act of negative plate form, manufacture is easy and cooling designed for easy direction. More superior result of cooling appeared than existing in incidental and ingredients, cooling efficiency, composition, complexity, convenience etc. that expense and composition manufacture very straightforwardly and experimental by 2 - Tank ways.

신경계 치료를 위한 루프 프로브형 자기자극기의 시뮬레이터 (The simulator loop probe style magnetic stimulation design for a nervous system treatment)

  • 김휘영
    • 디지털산업정보학회논문지
    • /
    • 제5권3호
    • /
    • pp.29-37
    • /
    • 2009
  • It is as result that study to apply mini magnet nerve curer in peripheral nervous system disease treatment. Simulator and embodied action power and Control Unit in cylinder form of magnet roof object firstly. Yielded service area about special quality of probe of loop object cylinder style and treatment area dimension and distance of treatment pulse secondly. Embody pulse forming course energy value by Probe's form by third, could embody treatment pulse by disease. Specially, through a special quality experiment, saved Damping pulse form and treatment digital forming etc. variously. Lately, embodied this to aid a little in disease treatment that follow that there is no invasion that there is no stimulation by medicine development. Neuralgia, muscular disease and Altzheimer, with stroke etc. is becoming the matter of concern and interest which disease of adult etc. it is same is important. And the melancholia in compliance with the modern direction of a ceremony which is complicated and garrulous, trillion it will cry and symptoms, it is a tendency where the emotional obstacle etc. nervous psychiatric disorder patient is increasing at class speed. But currently the applicator it will be able to treat like this disease almost it is a condition which is wholly lacking. Consequently like this disease it used magnetic stimulation and it diagnosed and the equipment it will be able to treat plan and it embodied.

전기와 자기장의 침 자극을 포함한 복합치료가 말초성 안면신경마비에 미치는 영향에 대한 관찰 연구 (Clinical Observations of Complex Therapy, including Electroacupuncture and Magnetic-acupuncture, for Treating Peripheral Facial Nerve Palsy)

  • 오서영;이현;강재희
    • Journal of Acupuncture Research
    • /
    • 제33권3호
    • /
    • pp.117-127
    • /
    • 2016
  • Objectives : This study was performed to observe the effect of complex therapy, including electro-acupuncture and magnetic-acupuncture, on peripheral facial nerve palsy. Methods : Nine patients with peripheral facial nerve palsy were treated with acupuncture using electrical and magnetic stimulation. Acupoints in the face were stimulated with an electromagnetic field, as widely and as evenly as possible. To evaluate the effects before and after treatment we used Yanagihara's unweighted grading system, House-Brackmann scale, and Sunnybrook facial grading system and image once a week. Results : After treatment, the scores of Yanagihara's unweighted grading system, House-Brackmann scale and Sunnybrook facial grading system each improved (p-value < 0.05). Conclusion : Complex therapy using electro-acupuncture and magnetic-acupuncture might be an effective treatment to improve symptoms of peripheral facial nerve palsy. Further randomized-controlled trials are required to verify the efficacy and results of this study.

Evaluation of Neuronal Dysfunction in Schizophrenia before and after Neuroleptic Treatment by ??H MRS

  • C, Bo-Young;Paik, In-Ho;Lee, Chang-Uk;Lee, Hyoung-Koo;Suh, Tae-Suk
    • 한국자기공명학회논문지
    • /
    • 제5권1호
    • /
    • pp.56-65
    • /
    • 2001
  • Localized in vivo proton magnetic resonance spectroscopy (MRS) was performed to evaluate metabolic alterations in the right and left frontal lobe before and after neuroleptic treatment of schizophrenic patients (n=24) and a group of healthy normal subjects (n=20). Proton metabolic ratios obtained from the 8㎤ yokels in the right and left frontal lobe were compared with the clinical assessment of PANSS for each subject. There was no significant difference in the metabolic ratios between the right and the left frontal lobes in either the schizophrenic group or the control group, indicating no laterality. Compared with those of the normal control group, NAA/Cr and (GABA+Glu)/Cr ratios of the schizophrenic patients showed significantly lower (p=0.023) and higher (p=0.005) value, respectively. The (GABA+Glu)/Cr ratio of the schizophrenic patients was generally decreased after neuroleptic treatment, while the NAA/Cr ratio was not changed. Significant correlation between the (GABA+Glu)/Cr ratio and the clinical symptom scores assessed by PANSS was established. The present study supports the “hypofrontality” hypothesis of schizophrenia on the basis of the altered metabolic ratios before and after neuroleptic treatment.

  • PDF

$Ni_{0.5}Cu_{0.1}Zn_{0.4}Fe_2O_4$ Ferrite-Rubber Composite의 전파흡수특성에 미치는 열처리 온도의 영향 및 Carbon 첨가효과 (Effect of Carbon Addition and Influence of Heat-treatment Temperature on Electromagnetic Wave Absorbing Properties of $Ni_{0.5}Cu_{0.1}Zn_{0.4}Fe_2O_4$-Rubber Composite)

  • 윤국태;이찬규;박연준
    • 한국자기학회지
    • /
    • 제11권1호
    • /
    • pp.14-20
    • /
    • 2001
  • The structure, shape, size, and magnetic properties of Ni$_{0.5}$Cu$_{0.1}$Zn$_{0.4}$Fe$_2$O$_4$ have been investigated as a function of annealing temperatures. In order to control the microwave absorbing properties of ferrite-rubber composite and the complex losses (magnetic loss and conduction loss), the effect of carbon addition was also studied. It was found that the coercive force decreased with increasing heat-treatment temperatures. Relative complex permeability and reflection loss were measured by the network analyzer. As a result, the natural resonance occurred in the low frequency tinge, and the matching frequency of the ferrite-rubber composite prepared at 130$0^{\circ}C$ was found to be lower. As heat-treatment temperatures were increased, the magnetic loss ($\mu$$_{r}$", $\mu$$_{r}$′) and the dielectric loss ($\varepsilon$$_{r}$"/$\varepsilon$$_{r}$′) were increased. It was caused that the absorption characteristics of the absorber were improved. The conduction loss and magnetic loss were expected to be occurred together because two matching frequencies were shown with carbon addition. It was confirmed that the matching frequency of the microwave absorber could be controlled by controlling heat-treatment temperatures and carbon additions.ons.tions.

  • PDF

The treatment of coolant wastewater of rolling plate process by High Gradient Magnetic Separation

  • Kim, Tae-Hyung;Ha, Dong-Woo;Kwon, Jun-Mo;Sohn, Myung-Hwan;Baik, Seung-Kyu;Oh, Sang-Soo;Ko, Rock-Kil;Kim, Ho-Sup;Kim, Young-Hun;Park, Seong-Kuk
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제11권4호
    • /
    • pp.8-11
    • /
    • 2009
  • This study introduced wastewater treatment method by High Gradient Magnetic Separation (HGMS). HGMS treatment was high efficient method for various industrial wastewaters. The system is currently research state, but we have surveyed commercialize the technology for industry. In rolling plate process, coolant wastewater was recycled by sedimentation and sand filter system. It needs several large reservoirs and long time to remove suspended solid (SS) like metal fines and iron oxide in hot rolling plate making process. If removing rate of suspended solid in rolling coolant wastewater is improved by using HGMS system, the productivity of working process can be increased and the area of reservoir can be reduced. We manufactured high temperature superconducting HGMS system that had a purpose to treatment of coolant wastewater in rolling plate process. We fabricated the prototypes of magnetic matrix filter consisting of stainless steel 430 mesh, which is a core component in the magnetic separation system, In our basic preliminary experiment using HGMS system, it has been clear that the fine paramagnetic particles in the coolant wastewater obtained from rolling plate process of POSCO can be separated with high efficiency.

초전도 자기분리에 의한 냉연공정 폐수처리 (Treatment of rolling cooling waste water by superconductor HGMS method)

  • 김태형;하동우;오상수;김영훈;하태욱
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2008년도 하계학술대회 논문집 Vol.9
    • /
    • pp.295-295
    • /
    • 2008
  • This study introduced waste water treatment method applied superconductor HGMS(High Gradient Magnetic Separation). HGMS method treat high efficient method for various waste water. we have surveyed superconducting magnetic separation technology and reviewed the status of related industries using applied superconductivity. We fabricated the prototypes of magnetic matrix filter consisting of stainless steel mesh, which is a core component in the magnetic separation system. In our basic preliminary experiment using HGMS, it was made clear that the fine para-magnetic particles in the rolling colling wasted water obtained from rolling process of POSCO can be separated with high efficiency.

  • PDF

Superconductivity for HTS GdBCO CC with heat treatment

  • You, Jong Su;Yang, Jeong Hun;Song, Kyu Jeong
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제23권1호
    • /
    • pp.12-16
    • /
    • 2021
  • The magnetic properties of heat treated O-series high temperature superconducting (HTS) GdBCO coated conductor (CC) tapes which were formed of Ag/GdBCO/Buffer-layers/Stainless Steel (SS), were investigated by employing a Quantum Design PPMS-14. Using a modified Bean model, the critical current density Jc values have been estimated from the 𝚫mirr(H) data, which are obtained by measuring the magnetic moment m(H) loops. For a range of intermediate fields, which are interacting or collective flux pinning area, the magnetic flux behaviors were investigated from the relationship Jc ∝ H. In addition, the changes of irreversibility magnetic field Hirr line of heat-treated O-series HTS GdBCO CC tapes were analyzed, according as the annealing temperature under oxygen flowing increases. Both weak and strong break-downs were found by examining the changes of irreversibility magnetic field Hirr lines.