• 제목/요약/키워드: magnetic transducer

검색결과 82건 처리시간 0.024초

3차원 의료영상진단기기를 이용한 가상 전립선 용적 측정 (Measurement of Prostate Phantom Volume Using Three-Dimensional Medical Imaging Modalities)

  • 성열훈;주용현;최보영
    • 대한의용생체공학회:의공학회지
    • /
    • 제31권4호
    • /
    • pp.285-291
    • /
    • 2010
  • Recently, advance on various modalities of diagnosing, prostate volume estimation became possible not only by the existing two-dimension medical images data but also by the three-dimensional medical images data. In this study, magnetic resonance image (MRI), computer tomography (CT) and ultrasound (US) were employed to evaluate prostate phantom volume measurements for estimation, comparison and analysis. For the prostate phantoms aimed at estimating the volume, total of 17 models were developed by using devils-tongue jelly and changing each of the 5ml of capacity from 20ml to 100ml. For the volume estimation through 2D US, the calculation of the diameter with C9-5Mhz transducer was conducted by ellipsoid formula. For the volume estimation through 3D US, the Qlab software (Philips Medical) was used to calculate the volume data estimated by 3D9-3Mhz transducer. Moreover, the images by 16 channels CT and 1.5 Tesla MRI were added by the method of continuous cross-section addition and each of imaginary prostate model's volume was yielded. In the statistical analysis for comparing the availability of volume estimation, the correlation coefficient (r) was more than 0.9 for all indicating that there were highly correlated, and there were not statistically significant difference between each of the correlation coefficient (p=0.001). Therefore, the estimation of prostate phantom volume using three-dimensional modalities of diagnosing was quite closed to the actual estimation.

MODE CONTROL OF GUIDED WAVE IN MAGNETIC HOLLOW CYLINDER USING ELECTROMAGNETIC ACOUSTIC TRANSDUCER ARRAY

  • FURUSAWA, AKINORI;KOJIMA, FUMIO;MORIKAWA, ATSUSHI
    • Nuclear Engineering and Technology
    • /
    • 제47권2호
    • /
    • pp.196-203
    • /
    • 2015
  • The aim of this work is to demonstrate a method for exciting and receiving torsional and longitudinal mode guided waves with an electromagnetic acoustic transducer (EMAT) ring array. First of all, a three-dimensional guided wave simulator is developed in order to numerically analyze the propagation of the guided wave. The finite difference time domain method is used for the simulator. Second, two guided wave testing systems using an EMAT ring array are provided: one is for torsional mode (T-mode) guided wave and the other is for longitudinal mode (L-mode). The EMATs used in the both systems are the same in design. A method to generate and receive the T- and L-mode guided waves with the same EMAT is proposed. Finally, experimental and numerical results are compared and discussed. The results of experiments and simulation agree well, showing the potential of the EMAT ring array as a mode controllable guided wave transmitter and receiver.

일렉트로어쿠스틱 기타용 광 픽업의 개발 (Development of Optical Pickup for ElectroAcoustic Guitar)

  • 신봉희;박영우
    • 한국정밀공학회지
    • /
    • 제31권5호
    • /
    • pp.417-422
    • /
    • 2014
  • A guitar pickup is a transducer that converts string vibration to an electrical signal. The magnetic and piezo pickups are the most commonly used for the respective electric and electroacoustic guitars. The magnetic pickups are prone to magnetic interference between the steel strings and permanent magnets, while the piezo ones are not free from signal inference between the strings. Thus, this paper presents the development of an optical pickup for the electroacoustic guitar. The proposed optical pickup has the top-to-bottom structure. It uses two of Infrared (IR) Light Emitting Diode (LED) and one photodetector. The developed optical pickup is subjected to the evaluation with commonly used piezoelectric pickup. It becomes obvious that SNR with the optical pickup is increased by 45 percent in average, compared with the piezoelectric pickup. It can be concluded that the developed optical pickup has a potential to be applied to the acoustic guitar.

광 CT용 자성 가넷 막의 에피택시 육성 및 평가 (Epitaxial Growth and Evaluation of Magnetic Garnet Films for Optical Current Transducers)

  • 조재경
    • 한국자기학회지
    • /
    • 제17권6호
    • /
    • pp.246-252
    • /
    • 2007
  • 본 논문에서는 출발원료 배합비 및 육성 파라미터가 LPE(Liquid Phase Epitaxy)법으로 육성된 자성 가넷 막의 특성에 미치는 영향을 조사하며, 광 CT의 페러데이 회전자용으로서 적합한 막의 육성 조건을 제시한다. 막을 평가하기 위하여 조사한 특성은 막후, 표면 모폴로지, X선 회절, 격자상수, 막과 기판(단결정 비자성 가넷 웨이퍼)사이의 격자상수의 부정합, 페러데이 회전각 등이었다. 또한, 육성된 자성 가넷 막을 이용하여 광 CT를 제작하고, 성능을 평가했다.

Magnetic Resonance-Guided Focused Ultrasound : Current Status and Future Perspectives in Thermal Ablation and Blood-Brain Barrier Opening

  • Lee, Eun Jung;Fomenko, Anton;Lozano, Andres M.
    • Journal of Korean Neurosurgical Society
    • /
    • 제62권1호
    • /
    • pp.10-26
    • /
    • 2019
  • Magnetic resonance-guided focused ultrasound (MRgFUS) is an emerging new technology with considerable potential to treat various neurological diseases. With refinement of ultrasound transducer technology and integration with magnetic resonance imaging guidance, transcranial sonication of precise cerebral targets has become a therapeutic option. Intensity is a key determinant of ultrasound effects. High-intensity focused ultrasound can produce targeted lesions via thermal ablation of tissue. MRgFUS-mediated stereotactic ablation is non-invasive, incision-free, and confers immediate therapeutic effects. Since the US Food and Drug Administration approval of MRgFUS in 2016 for unilateral thalamotomy in medication-refractory essential tremor, studies on novel indications such as Parkinson's disease, psychiatric disease, and brain tumors are underway. MRgFUS is also used in the context of blood-brain barrier (BBB) opening at low intensities, in combination with intravenously-administered microbubbles. Preclinical studies show that MRgFUS-mediated BBB opening safely enhances the delivery of targeted chemotherapeutic agents to the brain and improves tumor control as well as survival. In addition, BBB opening has been shown to activate the innate immune system in animal models of Alzheimer's disease. Amyloid plaque clearance and promotion of neurogenesis in these studies suggest that MRgFUS-mediated BBB opening may be a new paradigm for neurodegenerative disease treatment in the future. Here, we review the current status of preclinical and clinical trials of MRgFUS-mediated thermal ablation and BBB opening, described their mechanisms of action, and discuss future prospects.

Rosen형 압전 변압기 구조를 적용한 자기-전기 복합체의 특성 (Characteristics of Magnetoelectric Composite with Rosen Type Piezoelectric Transducer Structure)

  • 박성훈;윤운하;;류정호
    • 한국전기전자재료학회논문지
    • /
    • 제34권6호
    • /
    • pp.480-486
    • /
    • 2021
  • Magnetoelectric (ME) composite is composed of a piezoelectric material and a magnetostrictive material. Among various ME structures, 2-2 type layered ME composites are anticipated to be used as high-sensitivity magnetic field sensors and energy harvesting devices especially operating at its resonance modes. Rosen type piezoelectric transducer using piezoelectric material is known to amplify a small electrical input voltage to a large electrical output voltage. The output voltage of these Rosen type piezoelectric transducers can be further enhanced by modifying them into ME composite structures. Herein, we fabricated Rosen type ME composites by sandwiching Rosen type PMN-PZT single crystal between two Ni layers and studied their ME coupling. However, the voltage step-up ratio at the resonance frequency was found to be smaller than the value calculated with αME value. The ATILA FEA (Finite Elements Analysis) simulation results showed that the position of the nodal point was changed with the presence of a magnetostrictive layer. Thus, while designing a Rosen type ME composite with high performance in a resonant driving situation, it is necessary to optimize the position of the nodal point by optimizing the thickness or length of the magnetostrictive layer.

초음파 영상을 이용한 고강도 집중 초음파 빔 시각화 (High-intensity focused ultrasound beam path visualization using ultrasound imaging)

  • 송재희;장진호;유양모
    • 한국음향학회지
    • /
    • 제39권1호
    • /
    • pp.16-23
    • /
    • 2020
  • 고강도 집중 초음파(High-Intensity Focused Ultrasound, HIFU) 치료에서 HIFU 초점의 효과적인 위치 파악은 안전한 치료 계획을 개발하는 데 중요하다. 자기 공명 영상 유도 HIFU(Magnetic Resonance Imaging guided HIFU, MRIgHIFU)는 HIFU 초점을 영상화하여 치료 중에 초음파 경로를 시각화 할 수 있지만 초음파 이미징 유도 HIFU(Ultrasound imaging guided HIFU, USIgHIFU)에서는 어려움이 있다. 본 연구에서는 USIgHIFU에 대해 HIFU 초점을 영상화할 수 있는 실시간 초음파 빔 시각화 기법을 제시 하였다. 제안 된 방법에서, 음향 강도(Ispta < 720 mW/㎠) 아래의 이미징 초음파 변환자의 동일한 중심 주파수를 갖는 짧은 펄스가 HIFU 변환기를 통해 전송되고, HIFU 빔 경로를 시각화하기 위해 수신 신호는 동적 수신 포커싱 및 후속 에코 처리를 거쳤다. 소 혈청 알부민 젤 팬텀을 이용한 생체외 실험으로부터, HIFU 빔 경로는 낮은 음향 강도 (Ispta = 94.8 mW/㎠)에서도 명확히 영상화 할 수 있었고 HIFU 초점은 손상이 생성되기 전에 성공적으로 시각화하였다. 이 결과는 제안 된 초음파 빔 경로 시각화 방법이 USIgHIFU 치료에서 원치 않는 조직 손상을 최소화하면서 실시간으로 HIFU 초점을 영상화하는 데 사용될 수 있음을 나타낸다.

자기장을 이용한 컨베이어 벨트 파손 감지장치 개발 (The Development of Detection System of Conveyer Belt Damage using Magnetic Flux)

  • 양근호;민병운
    • 한국전자통신학회논문지
    • /
    • 제8권6호
    • /
    • pp.815-822
    • /
    • 2013
  • 본 논문에서는 물류 시스템에서 원료의 운송 작업에 필요한 컨베이어 고무벨트의 파손을 감지할 수 있는 시스템 개발에 대한 연구이다. 벨트의 내부에 전기 유도가 가능한 재료를 삽입하여 벨트의 파손이 발생했을 경우 전자 시스템에 의한 벨트의 파손을 감지할 수 있는 시스템을 개발하여 벨트의 파손을 최소화하도록 하였다. 따라서 벨트의 수리비용이나 운송 중인 물류의 재정리 단계의 시간을 줄일 수 있다. 벨트의 파손을 감지하기 위한 방법으로 송신 신호를 벨트 내에 삽입된 코일에 유도하고, 수신 측에서 코일에서 유도되는 전기 현상을 감지하여 벨트의 파손을 감지하도록 하였다.

SAW 여기를 위한 EMAT의 설계 및 제작에 관한 연구 (Design and Fabrication of EMAT for Excitation of SAW)

  • 김흥기;이재승;전계석
    • 한국음향학회지
    • /
    • 제9권3호
    • /
    • pp.24-30
    • /
    • 1990
  • 본 연구에서는 표면에서 한파장 깊이 이내에 존재하는 결함 검출에 우수한 특성을 나타내는 meander line형 EMAT를 설계, 제작하고 그 특성을 연구분석하였다. 효율적인 동 자기장을 위하여 간격 0.72mm와 폭 0.65mm의 코일을 구성하였으며 정 자기장을 위하여 1500 가우스의 자석군을 구성하였다. 제작된 EMAT는 중심 주파수 2MHz, 비대역폭 36%를 가지며 임펄스응답 특성은 0.15 mm의 비접촉 방법으로 측정되어 이론과 비교되었고 중심 주파수에서의 삽입손실은 45.46 dB로 측정되었다.

  • PDF

위치 검출기가 없는 영구자석 동기 전동기의 제어 PART1 - 표면부착형 영구자석 전동기 (Vector Control of PM Motor without any Rotational Transducer PART 1 - Surface Mounted Permanent Magnet Motor)

  • 장지훈;하정익;설승기
    • 대한전기학회논문지:전기기기및에너지변환시스템부문B
    • /
    • 제50권9호
    • /
    • pp.453-458
    • /
    • 2001
  • This paper presents a new vector control algorithm of the surface mounted permanent magnet motor (SMPMM) without any rotational tranceducer. Originally, SMPMM does not have any magnetic saliency in structure, but it has a little magnetic saliency due to the saturation by the flux of the permanent magnet. Moreover, it varies according to the load conditions and the control performance of schematics using the saliency can be easily degraded. To prevent it and to improve the performance of the proposed algorithm, the saliency of a SMPMM under various load conditions is analyzed. In the proposed algorithm, the saliency or the impedance difference related to the saliency is utilized in order to estimate the position and speed of the rotor. And the high frequency signal is injected into the motor to measure the impedance difference and also to enhance the control performance of the system. The experimental results verify the performance of the proposed sensorless algorithm.

  • PDF