• Title/Summary/Keyword: magnetic susceptibility

Search Result 402, Processing Time 0.027 seconds

Evaluation of the Usefulness of PROPELLER (periodically rotated overlapping parallel lines with enhanced reconstruction) Technique to Reduce the Magnetic susceptibility artifact (Magnetic susceptibility artifact를 줄이기 위한 PROPELLER 확산강조영상기법의 유용성에 대한 평가)

  • Cho, Jae-Hwan
    • Journal of Digital Contents Society
    • /
    • v.11 no.1
    • /
    • pp.73-78
    • /
    • 2010
  • This study attempted to examine whether the propeller diffusion weighted image method may remove magnetic susceptibility artifacts caused by metallic materials. A comparison of occurrence rates of magnetic susceptibility artifacts in the four regions, both temporal lobes, pons, and orbit, between b = 0 and b = 1,000 s/mm2 images was made after obtaining echo-planar diffusion weighted image, propeller diffusion weighted image, and ADC map images, respectively, from a total of 20 patients who had MRI shots taken of their brain and were found to be with retained metallic foreign bodies within their teeth using a 3.0T MR scanner. In the case of echo-planar diffusion weighted image technique, the presence of metallic materials may bring in some limits on accurate diagnosis due to magnetic susceptibility artifacts, while the propeller diffusion weighted image technique where magnetic susceptibility artifacts decrease is expected to be more useful in ensuring accurate diagnosis in the clinical context.

Efficient Experimental Design for Measuring Magnetic Susceptibility of Arbitrarily Shaped Materials by MRI

  • Hwang, Seon-ha;Lee, Seung-Kyun
    • Investigative Magnetic Resonance Imaging
    • /
    • v.22 no.3
    • /
    • pp.141-149
    • /
    • 2018
  • Purpose: The purpose of this study is to develop a simple method to measure magnetic susceptibility of arbitrarily shaped materials through MR imaging and numerical modeling. Materials and Methods: Our 3D printed phantom consists of a lower compartment filled with a gel (gel part) and an upper compartment for placing a susceptibility object (object part). The $B_0$ maps of the gel with and without the object were reconstructed from phase images obtained in a 3T MRI scanner. Then, their difference was compared with a numerically modeled $B_0$ map based on the geometry of the object, obtained by a separate MRI scan of the object possibly immersed in an MR-visible liquid. The susceptibility of the object was determined by a least-squares fit. Results: A total of 18 solid and liquid samples were tested, with measured susceptibility values in the range of -12.6 to 28.28 ppm. To confirm accuracy of the method, independently obtained reference values were compared with measured susceptibility when possible. The comparison revealed that our method can determine susceptibility within approximately 5%, likely limited by the object shape modeling error. Conclusion: The proposed gel-phantom-based susceptibility measurement may be used to effectively measure magnetic susceptibility of MR-compatible samples with an arbitrary shape, and can enable development of various MR engineering parts as well as test biological tissue specimens.

Proposing a low-frequency radiated magnetic field susceptibility (RS101) test exemption criterion for NPPs

  • Min, Moon-Gi;Lee, Jae-Ki;Lee, Kwang-Hyun;Lee, Dongil
    • Nuclear Engineering and Technology
    • /
    • v.51 no.4
    • /
    • pp.1032-1036
    • /
    • 2019
  • When the equipment which is related to safety or important to power production is installed in nuclear power plant units (NPPs), verification of equipment Electromagnetic Susceptibility (EMS) must be performed. The low-frequency radiated magnetic field susceptibility (RS101) test is one of the EMS tests specified in U.S NRC (Nuclear Regulatory Commission) Regulatory Guide (RG) 1.180 revision 1. The RS101 test verifies the ability of equipment installed in close proximity to sources of large radiated magnetic fields to withstand them. However, RG 1.180 revision 1 allows for an exemption of the low-frequency radiated magnetic susceptibility (RS101) test if the safety-related equipment will not be installed in areas with strong sources of magnetic fields. There is no specific exemption criterion in RG 1.180 revision 1. EPRI TR-102323 revision 4 specifically provides a guide that the low-frequency radiated magnetic field susceptibility (RS101) test can be conservatively exempted for equipment installed at least 1 m away from the sources of large magnetic fields (>300 A/m). But there is no exemption criterion for equipment installed within 1 m of the sources of smaller magnetic fields (<300 A/m). Since some types of equipment radiating magnetic flux are often installed near safety related equipment in an electrical equipment room (EER) and main control room (MCR), the RS101 test exemption criterion needs to be reasonably defined for the cases of installation within 1 m. There is also insufficient data regarding the strength of magnetic fields that can be used in NPPs. In order to ensure confidence in the RS101 test exemption criterion, we measured the strength of low-frequency radiated magnetic fields by distance. This study is expected to provide an insight into the RS101 test exemption criterion that meets the RG 1.180 revision 1. It also provides a margin analysis that can be used to mitigate the influence of low-frequency radiated magnetic field sources in NPPs.

Study of the ageing of hollow fibers in an industrial module for drinking water production

  • Wang, S.;Wyart, Y.;Perot, J.;Nauleau, F.;Moulin, P.
    • Membrane and Water Treatment
    • /
    • v.4 no.1
    • /
    • pp.53-67
    • /
    • 2013
  • In this study, ageing characteristics of an industrial hollow-fiber membrane module were investigated after 50 months of drinking water production. For this purpose, the industrial module was opened to make 18 smaller modules with hollow-fibers taken from different parts of the industrial module. These modules were probed by the use of a magnetic nanoparticle (NP) challenge test based on magnetic susceptibility (K) measurement of permeate. No magnetic susceptibility was detected in permeate when the challenge test was performed on an intact membrane module, indicating the complete retention of nanoparticles by the membrane. The compromised membrane module can be successfully detected by means of magnetic susceptibility measurement in permeate. So, this study clearly demonstrates that ageing of ultrafiltration membranes can be monitored by measuring the magnetic susceptibility of permeate from an ultrafiltration membrane module. These results showed that the hollow fibers in the center zones of the bundle would age faster than those in the outer zones around the bundle. This result is in agreement with numerical simulation (Daurelle et al. 2011).

SSFP Interferometry (SSFPI) Technique Applied to functional MRI - A Fast and Direct Measurement of Magnetic Susceptibility Effect (SSFPI 기법을 이용한 MR 뇌기능 영상 -고 속의 자화율 효과의 직접적인 측정)

  • 정준영
    • Journal of Biomedical Engineering Research
    • /
    • v.17 no.4
    • /
    • pp.525-534
    • /
    • 1996
  • We have developed a fast steady state free precession interferometry (SSFPI) technique which is useful for the fMRl (functional Magnetic Resonance Imaging). As is known, SSFP sequence with a suitable adjustment of Vadient (readeut) allows us to measure precession angle 6 which in tw relates to the field inhomogeneity. Combining the two pulses (known as FID and Echo) in FADE (Fast Acquisition Double Echo) sequence, for example, one can obtain the interference term which is directly related to the precession angle It has been known that a fast high resolution magnetic field mapping is possible by use of the modified FADE sequence or SSFPI, and we have attempted to use the SSFPI technique for the susceptibility-induced fMRl. When the method is applied to the susceptibility effect based functional magnetic resonance imaging (fMRl), it was found that the direct susceptibility effect measurement was possible without perturbations such as the backgrounds and inflow effect. In this paper, simulation results and experimental results obtained with 2.0 Tesla MRI system are presented.

  • PDF

Zr-7Cu Alloy Design According to Sn Content for Bio-Metallic Materials (금속 생체재료를 위한 Sn 함량에 따른 Zr-7Cu 합금설계)

  • Kim, Min-Suk;Kim, Chung-Seok
    • Korean Journal of Materials Research
    • /
    • v.31 no.12
    • /
    • pp.690-696
    • /
    • 2021
  • The purpose of this study is to develop a zirconium-based alloy with low modulus and magnetic susceptibility to prevent the stress-shielding effect and the generation of artifacts. Zr-7Cu-xSn (x = 1, 5, 10, 15 mass%) alloys are prepared by an arc melting process. Microstructure characterization is performed by microscopy and X-ray diffraction. Mechanical properties are evaluated using micro Vickers hardness and compression test. The magnetic susceptibility is evaluated using a SQUID-VSM. The average magnetic susceptibility value of the Zr-7Cu-xSn alloy is 1.176 × 10-8 cm3g-1. Corrosion tests of zirconium-based alloys are conducted through polarization test. The average Icorr value of the Zr-7Cu-xSn alloy is 0.1912 ㎂/cm2. The elastic modulus value of 14 ~ 18 GPa of the zirconium-based alloy is very similar to the elastic modulus value of 15 ~ 30 GPa of the human bone. Consequently, the Sn added zirconium alloy, Zr-7Cu-xSn, is very interesting and attractive as a biomaterial that reduces the stress-shielding effect caused by differences of elastic modulus between human bone and metallic implants. In addition, this material has the potential to be used in metallic dental implants to effectively eliminate artifacts in MRI images due to low magnetic susceptibility.

Arterial Spin Labelling Perfusion, Proton MR Spectroscopy and Susceptibility-Weighted MR Findings of Acute Necrotizing Encephalopathy: a Case Report

  • Kwon, Hwanwoong;Choi, Dae Seob;Jang, Jungho
    • Investigative Magnetic Resonance Imaging
    • /
    • v.23 no.2
    • /
    • pp.157-161
    • /
    • 2019
  • In this study, we report arterial spin labelling perfusion, proton MR spectroscopy and susceptibility-weighted MR findings of acute necrotizing encephalopathy in a child with rotavirus infection.

3D Inversion of Aeromagnetic Data In an Area of Geumsan (금산지구 항공 자력탐사 자료의 3차원 역산)

  • Ko, Kwang-Beom;You, Young-Jun
    • Geophysics and Geophysical Exploration
    • /
    • v.17 no.2
    • /
    • pp.49-57
    • /
    • 2014
  • 3D magnetic inversion, based on the assemblage of 2D forward modeling and inversion as a practical technique to reflect the a priori information, was conducted to investigate the spatial distribution features of black-shale related and pyrometamorphic uranium deposit and several lithological units of Ogcheon Super Group in an area of Geumsan. By using the 3D visualization technique with suitable susceptibility interval and horizontal slice map, the spatial distribution of magnetic susceptibility corresponded to the black shale related uranium bearing lithological units, Black Slate member was well coincided with a information of uranium deposit. Also, even though it is indirect indicator for the detetction of uranium deposits interbedded in Gray Hornfels member, spatial susceptibility distribution which shows the south-east magnetic linearment corresponding to the Majeon-ri formation and Dark Gray Slate were matched well. From this investigation, we inferred that maximum depth extension which Black Slate member can be separately recognized with respect to adjacent Dark Gray Slate with strong magnetic susceptibility anomaly is about 150m with reference elevation level of 306m. In addition, Majeon-ri formation located south of Black Slate member revels relatively high magnetic susceptibility range but shows high spatial susceptibility fluctation. And, as an intrusive rocks, Jurassic Biotite Granite shows relatively low magnetic susceptibility characteristics. On the contrary, Cretaceous granite distributed in soutthern part of the study area shows the relatively high susceptibility distribution.

The Properties of Pusan Clay : Magnetic Susceptibility of Deltaic sediments in Gadeok-do Area (부산점토의 특성: 가덕도 지역 조간대 퇴적물의 대자율)

  • 김성욱;김인수;이선갑;김무겸;정성교
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2003.03a
    • /
    • pp.747-752
    • /
    • 2003
  • This study was carried out to understand the stratigraphy and depositional environment of clayey soils that distributed in the Gadeok-do area, Kimhae plain (Nakdong estuary). For the study, SPT core sampling and magnetic susceptibility analysis were conducted. Soils in study area is classified into five sedimentary facies ascending order; sand/gravel. clay, sand/gravel, clay, interbedded sand and silty clay. Analysis of magnetic susceptibility for Gadeok-do clayey soil reveals that depositional process and environment can be divided into upper, middle and lower layer, and they are closely related to the sea level change since late Quaternary.

  • PDF

The Relationship between Climate Change and Magnetic Susceptibility of Estuarine Sediments (하구역 퇴적물의 대자율 변화와 기후변화의 연관성)

  • Shin, Young-Ho
    • Journal of the Korean association of regional geographers
    • /
    • v.17 no.5
    • /
    • pp.521-535
    • /
    • 2011
  • This study intended to explain the relationship between climate change and magnetic susceptibility of estuarine sediment. Data of OSL dating and magnetic susceptibility from estuarine tidal sediment were compared with various climate change data. During the last Holocene, the intense of magnetic susceptibility related with weaker Siberian High and stronger Asian Summer Monsoon. It is explained that high precipitation and runoff made much fluvial sediment input to the estuary. From the early to mid Holocene, there is no clear relationship between climate change and MS because of the much coastal sediment input caused by rapid sea level rise and the formation of upland soil and coastal marsh. These results contribute to reconstruct paleo-environmental changes of west coast of Korea, in the way of using benefit of ubiquitous estuarine tidal flats and relatively useful magnetic susceptibility methodoloy.

  • PDF