• Title/Summary/Keyword: magnetic resonance imaging contrast media

Search Result 29, Processing Time 0.026 seconds

A Study on Utility of Magnetic Resonance Imaging for Female Pelvic Cavity using Enteral MRI Contrast Media (Enteral MRI contrast media를 이용한 여성골반 자기공명영상의 유용성)

  • Kim, Ham-Gyum
    • Journal of radiological science and technology
    • /
    • v.20 no.1
    • /
    • pp.29-34
    • /
    • 1997
  • For radiological test in soft tissue or neighboring part with same signal intensity, proper test method and equipment shall be selected as needed. In case of female pelvic cavity, ultrasonography or computed tomography alternatively used, but MRI can be more usefully applied to design treatment method or operation plan by improving the diagnostic accuracy and careful observation of lesion characteristics. Magnetic Resonance Imaging using recently developed Enteral MRI contrast media can acquire more diagnostic information than using only intravenous contrast media. Thus this study attempted to examine the utility of anatomic structure and diagnostic acquisition by imaging the female pelvic cavity using Enteral MRI contrast media. As a result of analyzing magnetic resonance Imaging after administering Enteral MRI contrast media to pelvic cavity suspect patients, more diagnostic information media could be acquired than only using Intravenous contrast. Expecially, in the diagnosis of lesion position, shape, distinction from neighboring tissues it is thought that external Enteral MRI contrast media should be used.

  • PDF

How Computed Tomography Contrast Media and Magnetic Resonance Imaging Contrast Media Affect the Changes of Uptake Counts of 201Tl

  • Lee, Jin-Hyeok;Lee, Hae-Kag;Cho, Jae-Hwan;Cheon, Miju
    • Journal of Magnetics
    • /
    • v.19 no.4
    • /
    • pp.372-377
    • /
    • 2014
  • The purpose of the study is to investigate how uptake counts of $^{201}Tl$ of radioisotopes in the human body could change, when taking computed tomography and magnetic resonance imaging right after injecting contrast media. $^{201}Tl$ radioisotope substances of iodine contrast medium, which is a computed tomography contrast medium, and paramagnetic contrast medium, which is an magnetic resonance imaging contrast medium, were used as study materials. First, $^{201}Tl$ was put into 4 cc of normal saline in test tube, and then a computed tomography contrast medium of Iopamidol$^{(R)}$ or Dotarem$^{(R)}$, was put into 2 cc of normal saline in test tube. An magnetic resonance imaging contrast medium of Primovist$^{(R)}$ or Gadovist$^{(R)}$ was also put into 2 cc of normal saline in test tube. Each contrast medium was distributed to make $^{201}Tl$ as 3 mCi, with a total of 4 cc. Gamma camera, low energy high resolution collimator, and pinhole collimator were used to obtain images. The uptake count of $^{201}Tl$ was measured with 1000 frames of images, and obtained after 10 times of repetition. This study revealed that the use of Gadovist$^{(R)}$, which is an magnetic resonance imaging contrast medium, showed the smallest number of uptake count, after measuring $^{201}Tl$ uptake count by low energy high resolution collimator. On the other hand, the use of Iopamidol$^{(R)}$, which is a computed tomography contrast medium, showed the biggest difference in uptake count, when measuring $^{99m}Tc$ uptake count by Pinhole collimator. When examining with gamma camera, using contrast medium and $^{201}Tl$, identifying the changes of uptake count is very important for improving the value of diagnosis.

Influence of Iodinated Magnetic Resonance Contrast Media and Isotope 99mTc on Changes of Computed Tomography Number

  • Kim, Sang-Beom;Lee, Jin-Hyeok;Ahn, Jae-Ouk;Cho, Jae-Hwan
    • Journal of Magnetics
    • /
    • v.20 no.3
    • /
    • pp.302-307
    • /
    • 2015
  • The purpose of the study was to identify how isotope and magnetic resonance imaging (MRI) contrast media impact on noise to computed tomography (CT) examination. For the study, divide the phantoms to two groups: 1) saline, saline + different kinds of contrast agent without $^{99m}Tc$ administration; 2) $^{99m}Tc$ administration: saline, saline + different kinds of contrast agent with $^{99m}Tc$ administration. CT contrast agent was used for Iopamidol$^{(R)}$ and Dotarem. And MRI contrast agent was used for Primovist$^{(R)}$ and Gadovist$^{(R)}$. To obtain an image, we used CT scanner. With an obtained image, we set the $1cm^2$ region of interest in the middle of bottle to measure the noise and CT number. As a result, there was no difference in CT number before and after inserting $^{99m}Tc$ into all contrast media including Normal Saline. However, when it comes to Noise, there was a difference before and after inserting $^{99m}Tc$ into every contrast media except MRI contrast media such as Primovist$^{(R)}$ and Gadovist$^{(R)}$.

Emerging Role of Hepatobiliary Magnetic Resonance Contrast Media and Contrast-Enhanced Ultrasound for Noninvasive Diagnosis of Hepatocellular Carcinoma: Emphasis on Recent Updates in Major Guidelines

  • Tae-Hyung Kim;Jeong Hee Yoon;Jeong Min Lee
    • Korean Journal of Radiology
    • /
    • v.20 no.6
    • /
    • pp.863-879
    • /
    • 2019
  • Hepatocellular carcinoma (HCC) can be noninvasively diagnosed on the basis of its characteristic imaging findings of arterial phase enhancement and portal/delayed "washout" on computed tomography (CT) and magnetic resonance imaging (MRI) in cirrhotic patients. However, different specific diagnostic criteria have been proposed by several countries and major academic societies. In 2018, major guideline updates were proposed by the Association for the Study of Liver Diseases, European Association for the Study of the Liver (EASL), Korean Liver Cancer Association and National Cancer Center (KLCA-NCC) of Korea. In addition to dynamic CT and MRI using extracellular contrast media, these new guidelines now include magnetic resonance imaging (MRI) using hepatobiliary contrast media as the first-line diagnostic test, while the KLCA-NCC and EASL guidelines also include contrast-enhanced ultrasound (CEUS) as the second-line diagnostic test. Therefore, hepatobiliary MR contrast media and CEUS will be increasingly used for the noninvasive diagnosis and staging of HCC. In this review, we discuss the emerging role of hepatobiliary phase MRI and CEUS for the diagnosis of HCC and also review the changes in the HCC diagnostic criteria in major guidelines, including the KLCA-NCC practice guidelines version 2018. In addition, we aimed to pay particular attention to some remaining issues in the noninvasive diagnosis of HCC.

Optimal Cardiac Magnetic Resonance Contrast-Enhanced Timing Robust Angiography (CMR-CENTRA) for the Three-Dimensional Reconstruction of the Bilateral Atria in the Electroanatomic Mapping (EAM) of Atrial Fibrillation

  • Kim, Jun Seong;Oh, Yu-Whan;Shim, Jaemin;Kim, Young-Hoon;Hwang, Sung Ho
    • Investigative Magnetic Resonance Imaging
    • /
    • v.21 no.3
    • /
    • pp.131-138
    • /
    • 2017
  • Purpose: To optimize the timing of scans using cardiac magnetic resonance contrast-enhanced timing robust angiography (CMR-CENTRA) for electroanatomic mapping (EAM) of the right atrium (RA) and left atrium (LA) in patients with atrial fibrillation (AF). Materials and Methods: Fifty patients with AF (38 men; mean age, $59.6{\pm}9.3years$) underwent CMR-CENTRA in preparation for EAM. The CMR-CENTRA data were acquired at five different scan times: 0 seconds, 5 seconds, 10 seconds, 15 seconds, and 20 seconds after an intravenous injection of contrast media. To evaluate the degree of contrast enhancement, right atrial relative contrast (RA-RC) and left atrial relative contrast (LA-RC) on the CMR-CENTRA scans were assessed at each time point. The three-dimensional (3D) reconstruction of the RA and LA for the EAM system was performed using the CMR-CENTRA data. Results: A CMR-CENTRA at a scan time of 10 seconds showed significantly greater LA-RC (P < 0.05) compared with all other scan times. A CMR-CENTRA at a scan time of 15 seconds showed significantly greater RA-RC (P < 0.05) compared with all other scan times. In the 3D reconstruction of the RA, the success rates of CMR-CENTRA at scan times of 10 seconds and 15 seconds were 18% and 100%, respectively. In the 3D reconstruction of the LA, the success rates of CMR-CENTRA at 10- and 15-second scan times were 100%. Conclusion: The CMR-CENTRA data acquired at 15 seconds after the injection of contrast media is appropriate for the preparation of an EAM system that is focused on the RA and LA in patients with AF.

Benefit of Using Early Contrast-Enhanced 2D T2-Weighted Fluid-Attenuated Inversion Recovery Image to Detect Leptomeningeal Metastasis in Lung-Cancer Staging

  • Kim, Han Joon;Lee, Jungbin;Lee, A Leum;Lee, Jae-Wook;Kim, Chan-Kyu;Kim, Jung Youn;Park, Sung-Tae;Chang, Kee-Hyun
    • Investigative Magnetic Resonance Imaging
    • /
    • v.26 no.1
    • /
    • pp.32-42
    • /
    • 2022
  • Purpose: To evaluate the clinical benefit of 2D contrast-enhanced T2 fluid-attenuated inversion recovery (CE-T2 FLAIR) image for detecting leptomeningeal metastasis (LM) in the brain metastasis work-up for lung cancer. Materials and Methods: From June 2017 to July 2019, we collected all consecutive patients with lung cancer who underwent brain magnetic resonance image (MRI), including contrast-enhanced 3D fast spin echo T1 black-blood image (CE-T1WI) and CE-T2 FLAIR; we recruited clinico-radiologically suspected LM cases. Two independent readers analyzed the images for LM in three sessions: CE-T1WI, CE-T2 FLAIR, and their combination. Results: We recruited 526 patients with suspected lung cancer who underwent brain MRI; of these, we excluded 77 (insufficient image protocol, unclear pathology, different contrast media, poor image quality). Of the 449 patients, 34 were clinico-radiologically suspected to have LM; among them, 23 were diagnosed with true LM. The calculated detection performance of CE-T1WI, CE-T2 FLAIR, and combined analysis obtained from the 34 suspected LM were highest in the combined analysis (AUC: 0.80, 0.82, and 0.89, respectively). The inter-observer agreement was also the highest in the combined analysis (0.68, 0.72, and 0.86, respectively). In quantitative analyses, CNR of CE-T2 FLAIR was significantly higher than that of CE-T1WI (Wilcoxon signed rank test, P < 0.05). Conclusion: Adding CE-T2 FLAIR might provide better detection for LM in the brain-metastasis screening for lung cancer.

Magnetic Resonance Imaging in Thoracic Disease (흉부질환의 자기공명영상)

  • Song, Koun-Sik
    • Tuberculosis and Respiratory Diseases
    • /
    • v.40 no.4
    • /
    • pp.345-352
    • /
    • 1993
  • The role of magnetic resonance(MR) imaging in the evaluation of thoracic disease has been limited Nontheless, MR has inherent properties of better contrast resolution than CT allowing tissue-specific diagnosis. MR has capability of direct imaging in sagittal, coronal, and oblique planes which provide better anatomic information than axial images of CT such as lesions in the pulmonary apex, aorticopulmonary window, peridiaphragmatic region, and subcarinal region. MR is sensitive to blood flow making it an ideal imaging modality for the evaluation of cardiovascular system of the thorax without the need for intravenous contrast media. Technical developments and better control of motion artifacts have resulted in improved image quality, and clinical applications of MR imaging in thoracic diseases have been expanded. Although MR imaging is considered as a problem-solving tool in patients with equivocal CT findings, MR should be used as the primary imaging modality in the following situations: 1) Evaluation of the cardiovascular abnormalities of the thorax 2) Evaluation of the superior sulcus tumors 3) Evaluation of the chest wall invasion or mediastinal invasion by tumor 4) Evaluation of the posterior mediastinal mass, especially neurogenic tumor 5) Differentiation of fibrosis and residual or recurrent tumor, especially in lymphoma 6) Evaluation of brachial plexopathy With technical developments and fast scan capabilities, clinical indications for MR imaging in thorax will increase in the area of pulmonary parenchymal and pulmonary vascular imaging.

  • PDF

Comparison Between Contrast-Enhanced Computed Tomography and Contrast-Enhanced Magnetic Resonance Imaging With Magnetic Resonance Cholangiopancreatography for Resectability Assessment in Extrahepatic Cholangiocarcinoma

  • Jeongin Yoo;Jeong Min Lee;Hyo-Jin Kang;Jae Seok Bae;Sun Kyung Jeon;Jeong Hee Yoon
    • Korean Journal of Radiology
    • /
    • v.24 no.10
    • /
    • pp.983-995
    • /
    • 2023
  • Objective: To compare the diagnostic performance and interobserver agreement between contrast-enhanced computed tomography (CECT) and contrast-enhanced magnetic resonance imaging (CE-MRI) with magnetic resonance cholangiopancreatography (MRCP) for evaluating the resectability in patients with extrahepatic cholangiocarcinoma (eCCA). Materials and Methods: This retrospective study included treatment-naïve patients with pathologically confirmed eCCA, who underwent both CECT and CE-MRI with MRCP using extracellular contrast media between January 2015 and December 2020. Among the 214 patients (146 males; mean age ± standard deviation, 68 ± 9 years) included, 121 (56.5%) had perihilar cholangiocarcinoma. R0 resection was achieved in 108 of the 153 (70.6%) patients who underwent curative-intent surgery. Four fellowship-trained radiologists independently reviewed the findings of both CECT and CE-MRI with MRCP to assess the local tumor extent and distant metastasis for determining resectability. The pooled area under the receiver operating characteristic curve (AUC), sensitivity, and specificity of CECT and CE-MRI with MRCP were compared using clinical, surgical, and pathological findings as reference standards. The interobserver agreement of resectability was evaluated using Fleiss kappa (κ). Results: No significant differences were observed between CECT and CE-MRI with MRCP in the pooled AUC (0.753 vs. 0.767), sensitivity (84.7% [366/432] vs. 90.3% [390/432]), and specificity (52.6% [223/424] vs. 51.4% [218/424]) (P > 0.05 for all). The AUC for determining resectability was higher when CECT and CE-MRI with MRCP were reviewed together than when CECT was reviewed alone in patients with discrepancies between the imaging modalities or with indeterminate resectability (0.798 [0.754-0.841] vs. 0.753 [0.697-0.808], P = 0.014). The interobserver agreement for overall resectability was fair for both CECT (κ = 0.323) and CE-MRI with MRCP (κ = 0.320), without a significant difference (P = 0.884). Conclusion: CECT and CE-MRI with MRCP showed no significant differences in the diagnostic performance and interobserver agreement in determining the resectability in patients with eCCA.

Radiological Diagnosis for Posttraumatic Olfactory Dysfunction (외상 후 후각이상에 대한 방사선학적 진단)

  • Ahn, Jung Yong;Joo, Jin Yang;Chung, Tae Sub
    • Journal of Korean Neurosurgical Society
    • /
    • v.29 no.12
    • /
    • pp.1570-1576
    • /
    • 2000
  • Objective : To evaluate objectively the sites of injury in patients with posttraumatic olfactory deficits and to suggest the diagnostic procedure for evaluation of posttraumatic anosmia. Methods : Ten patients with posttraumatic olfactory dysfunction were examined by means of olfactory testing, sinoscopy, contrast filled paranasal sinus computed tomography(contrast filled PNS CT) and magnetic resonance imaging(MRI). Five normal persons without olfactory dysfunction were also evauluated. The aerodynamic patency of olfactory cleft was examined by contrast filled PNS CT. The olfactory system(oflactory bulbs, olfactory tracts, inferior frontal region, hippocampi, or temporal lobes) was investigated in detail with MRI. The difference in the size of the olfactory bulb between normal volunteers and anosmic patients was evaluated by Student's t test. Results : Contrast filled dynamic CT scan was useful method for the evaluation of dynamic patency of the olfactory cleft. Paranasal CT scan of the all anosmic patients showed dynamic reflux of contrast media in olfactory cleft on valsalva maneuver. For the largest cross-sectional area and great height, the difference in olfactory bulb size between normal volunteers and patients was statistically significant(p<0.001) in MRI study. Conclusion : Posttraumatic anosmia was completely evaluated by olfactory testing, sinoscopy, and contrast filled CT scan for differentiation between conductive type and neurogenic type. Neurogenic anosmia was confirmed by perfect localization with MRI study.

  • PDF

Syringe Reuse Issues in Automated Contrast Injection System in Dynamic Magnetic Resonance Imaging (조영제 자동주입기를 활용한 자기공명영상 동적검사 시 실린지 재사용의 문제)

  • Son, Soon-Yong
    • The Journal of the Korea Contents Association
    • /
    • v.19 no.11
    • /
    • pp.445-450
    • /
    • 2019
  • This study proves that syringe reuse of automated injection system entails a risk of contrast media reflux and saline solution contamination which are pumped by a piston into the patients' venous cannula in the dynamic MR images, we will be aware of the serious problem. To quantify the contrast media contamination effect on the saline solution, identical volume of the saline solution was collected before and after the contrast injection to the patients' venous cannula following T1 weighted image scanning to verify whether signal intensities differences are observed. The signal intensity of saline solution after the contrast injection was significantly higher than that of saline before injection by 523.43%. This result is due to the backflow that contaminates the saline solution on the opposite side when the contrast agent is injected. In conclusion, the syringe used to inject contrast medium. causes cross-contamination due to contrast reflux. Therefore, even if the same patient's examination is used for quantitative analysis, the error should be avoided by changing the acquisition sequence or replacing the syringe.