• Title/Summary/Keyword: magnetic field variation

Search Result 316, Processing Time 0.034 seconds

The AC loss of 22.9kV/50MVA High-Tc Superconducting Power Cable (22.9kV/50MVA급 고온초전도 전력케이블의 교류손실)

  • Choi, Suk-Jin;Lee, Sang-Jin;Sim, Ki-Deok;Cho, Jeon-Wook;Lee, Soo-Gil;Yang, Byeong-Mo;Yoon, Hyung-Hee
    • Progress in Superconductivity and Cryogenics
    • /
    • v.11 no.3
    • /
    • pp.31-34
    • /
    • 2009
  • An HTS power cable is generally composed of 2 layers for conducting and 1 layer for shielding. For the analysis of AC loss of an HTS power cable, 2-dimensional magnetic field analysis is carried out. The magnetization loss in HTS cable core was calculated, and the transport current loss was obtained from the monoblock equation and the elliptical Norris Equation. And the total AC loss of the cable was expected by the sum of magnetization loss and transport current loss. The variation of ac loss with respect to the gap and uncertain factor between the superconducting tapes was investigated, and the ac loss of 22.9kV/50MVA high-Tc superconducting power cable was calculated. These results well agree with those of experiment.

Monitoring of Gamma-ray Bright Quasars 3C279 and 1510-089 at 22, 43 and 86GHz using KVN Single Dish Telescopes

  • Baek, Jun-Hyun;Lee, Sang-Sung;Byun, Do-Young;Yang, Jee-Hye;Han, Myoung-Hee;Sohn, Bong-Won
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.37 no.2
    • /
    • pp.240.2-240.2
    • /
    • 2012
  • AGN(Active Galactic Nucleus) consists of a supermassive black hole located at its center, an accretion disk around the black hole, and bipolar jets. Since May 2011, we have performed the MOGABA(Monitoring Of GAmma-ray Bright AGN) project for observing gamma-ray bright AGN once a week at multifrequencies using KVN(Korean VLBI Network) 21m radio telescopes. The MOGABA project is the observations for measuring the degree of polarization, polarization angle, and total flux of about 20 AGN at 22, 43 and 86GHz. By this project, we are able to investigate polarization characteristics, spectral index, and variation of rotation measure at radio wavelengths of gamma-ray bright AGN and to study possible relation between gamma-ray flares and magnetic field structure change in AGN. According to previous research, gamma-ray flares of some AGN are coincident with large changes in angle of linear polarization. In this paper we report the preliminary results of linear polarization and total flux at 22, 43, 86GHz of gamma-ray bright quasars 3C279 and 1510-089 showing noticeable variation of total flux at 22GHz in late 2011, and discuss possible correlation with gamma ray light curves.

  • PDF

Characteristics of Mineral Mg Dissolving Sensor in Edible Water using GMR-SV Device (거대자기저항 스핀밸브 소자를 이용한 음용수 미네랄 Mg 용해센서 특성 연구)

  • Lee, Ju-Hee;Kim, Da-Woon;Kim, Min-Ji;Park, Kwang-Seo;Kang, Joon-Ho;Lee, Sang-Suk
    • Journal of the Korean Magnetics Society
    • /
    • v.18 no.5
    • /
    • pp.174-179
    • /
    • 2008
  • The measurement dissolution sensor system using GMR-SV device with magnetic sensitivity of 0.8 %/Oe and Mg-film thick of 200 nm and Mg-foil thick of 50 mm was fabricated and characterized. During the water dissolving process of Mg-film and Mg-foil, the subtle variation of magnetic field by the decrease of current in solenoid was detected by the GMR-SV sensor. The variations of Mg bubble number and ORP as a function of time for three different kinds of edible, tap, and distilled water, are measured and compared. A After 45 min, the speed of fast dissolving Mg was shown the order of edible > tap > DI water. The variation of output magnetoresistance as a function of dissolved time of Mg-film and Mg-foil for edible water, which is composed of mineral content of $0.8{\sim}5.4\;mg/l$ was investigated. The response times for the dissolution in edible water were 5 min and 20 min, respectively. From the measurement of dissolving time and speed for Mg-film and Mg-foil using GMR-SV device, the mineral Mg sensor system in edible water can be possible to develop.

Geomagnetic Paleosecular Variation in the Korean Peninsula during the First Six Centuries (기원후 600년간 한반도 지구 자기장 고영년변화)

  • Park, Jong kyu;Park, Yong-Hee
    • The Journal of Engineering Geology
    • /
    • v.32 no.4
    • /
    • pp.611-625
    • /
    • 2022
  • One of the applications of geomagnetic paleo-secular variation (PSV) is the age dating of archeological remains (i.e., the archeomagnetic dating technique). This application requires the local model of PSV that reflects non-dipole fields with regional differences. Until now, the tentative Korean paleosecular variation (t-KPSV) calculated based on JPSV (SW Japanese PSV) has been applied as a reference curve for individual archeomagnetic directions in Korea. However, it is less reliable due to regional differences in the non-dipole magnetic field. Here, we present PSV curves for AD 1 to 600, corresponding to the Korean Three Kingdoms (including the Proto Three Kingdoms) Period, using the results of archeomagnetic studies in the Korean Peninsula and published research data. Then we compare our PSV with the global geomagnetic prediction model and t-KPSV. A total of 49 reliable archeomagnetic directional data from 16 regions were compiled for our PSV. In detail, each data showed statistical consistency (N > 6, 𝛼95 < 7.8°, and k > 57.8) and had radiocarbon or archeological ages in the range of AD 1 to 600 years with less than ±200 years error range. The compiled PSV for the initial six centuries (KPSV0.6k) showed declination and inclination in the range of 341.7° to 20.1° and 43.5° to 60.3°, respectively. Compared to the t-KPSV, our curve revealed different variation patterns both in declination and inclination. On the other hand, KPSV0.6k and global geomagnetic prediction models (ARCH3K.1, CALS3K.4, and SED3K.1) revealed consistent variation trends during the first six centennials. In particular, the ARCH3K.1 showed the best fitting with our KPSV0.6k. These results indicate that contribution of the non-dipole field to Korea and Japan is quite different, despite their geographical proximity. Moreover, the compilation of archeomagnetic data from the Korea territory is essential to build a reliable PSV curve for an age dating tool. Lastly, we double-check the reliability of our KPSV0.6k by showing a good fitting of newly acquired age-controlled archeomagnetic data on our curve.

LOCAL TIMES OF GALACTIC COSMIC RAY INTENSITY MAXIMUM AND MINIMUM IN THE DIURNAL VARIATION (우주선 세기 일변화 최대 및 최소 지방시)

  • Oh Su-Yeon;Yi Yu
    • Journal of Astronomy and Space Sciences
    • /
    • v.23 no.2
    • /
    • pp.117-126
    • /
    • 2006
  • The Diurnal variation of galactic cosmic ray (GCR) flux intensity observed by the ground Neutron Monitor (NM) shows a sinusoidal pattern with the amplitude of $1{\sim}2%$ of daily mean. We carried out a statistical study on tendencies of the local times of GCR intensity daily maximum aad minimum. To test the influences of the solar activity and the location (cut-off rigidity) on the distribution in the local times of maximum and minimum GCR intensity, we have examined the data of 1996 (solar minimum) and 2000 (solar maximum) at the low-latitude Haleakala (latitude: 20.72 N, cut-off rigidity: 12.91 GeV) and the high-latitude Oulu (latitude: 65.05 N, cut-off rigidity: 0.81 GeV) NM stations. The most frequent local times of the GCR intensity daily maximum and minimum come later about $2{\sim}3$ hours in the solar activity maximum year 2000 than in the solar activity minimum you 1996. Oulu NM station whose cut-off rigidity is smaller has the most frequent local times of the GCR intensity maximum and minimum later by $2{\sim}3$ hours from those of Haleakala station. This feature is more evident at the solar maximum. The phase of the daily variation in GCR is dependent upon the interplanetary magnetic field varying with the solar activity and the cut-off rigidity varying with the geographic latitude.

Development of Performance Analysis 80 kW High-efficiency Permanent Magnet Generator for Radar System Power Supply (레이더 체계 전원공급용 80 kW급 고효율 영구자석형 발전기 개발 및 성능분석)

  • Ryu, Ji-Ho;Cho, Chong-Hyeon;Chong, Min-Kil;Park, Sung-Jin;Kang, Kwang-Hee
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.22 no.1
    • /
    • pp.60-71
    • /
    • 2019
  • Electrical power supply is needed to operate the radar system in the field. In addition, it should not cause performance deterioration under the environmental factors due to characteristics of military equipment, and should not cause malfunction due to electromagnetic waves generated in radar, and then should not cause malfunction in radar equipment. Therefore, By applying a permanent magnet to the rotor of the generator, light weighting and high efficiency of generator were achieved. As a result, electrical performance test of the generator, the rated output power was 80.8 kW, the maximum output power was 88.1 kW, and the output power efficiency was 98.1 % under the full load condition. When the load capacity of the generator was changed from no load to full load, the maximum voltage variation was 3.6 % and the frequency variation was 0.3 %. As a result of the transient response test for measuring the output power of the generator according to the load characteristics change, the maximum voltage variation of 7.9 %, frequency variation of 0.5 % were confirmed, and the transient response time was 2.1 seconds. Environmental tests were conducted in accordance with MIL-STD-810G and MIL-STD-461F to evaluate the operability of the generator groups. Normal operation of radar system generator group was confirmed under high temperature and low temperature environment conditions. Electromagnetic tests were conducted to check if electromagnetic wave generated from both radar system and generator group in operation caused any performance deterioration to each other. As a result, it was confirmed that the performance deterioration due to electromagnetic wave inflow, radiation, and conduction did not occur. It is expected that it should be possible to provide high efficiency power supply and stable power supply by applying to various military system as well as radar system.

Buckling behavior of smart MEE-FG porous plate with various boundary conditions based on refined theory

  • Ebrahimi, Farzad;Jafari, Ali
    • Advances in materials Research
    • /
    • v.5 no.4
    • /
    • pp.279-298
    • /
    • 2016
  • Present disquisition proposes an analytical solution method for exploring the buckling characteristics of porous magneto-electro-elastic functionally graded (MEE-FG) plates with various boundary conditions for the first time. Magneto electro mechanical properties of FGM plate are supposed to change through the thickness direction of plate. The rule of power-law is modified to consider influence of porosity according to two types of distribution namely even and uneven. Pores possibly occur inside FGMs due the result of technical problems that lead to creation of micro-voids in these materials. The variation of pores along the thickness direction influences the mechanical and physical properties. Four-variable tangential-exponential refined theory is employed to derive the governing equations and boundary conditions of porous FGM plate under magneto-electrical field via Hamilton's principle. An analytical solution procedure is exploited to achieve the non-dimensional buckling load of porous FG plate exposed to magneto-electrical field with various boundary condition. A parametric study is led to assess the efficacy of material graduation exponent, coefficient of porosity, porosity distribution, magnetic potential, electric voltage, boundary conditions, aspect ratio and side-to-thickness ratio on the non-dimensional buckling load of the plate made of magneto electro elastic FG materials with porosities. It is concluded that these parameters play remarkable roles on the dynamic behavior of porous MEE-FG plates. The results for simpler states are confirmed with known data in the literature. Presented numerical results can serve as benchmarks for future analyses of MEE-FG plates with porosity phases.

An Analysis of Geomagnetic Variations Related to Earthquakes Location which Occurred in and around the Korean Peninsula from 2012 to 2014 (지진 위치와 관련된 지자기장 변동성 분석: 2012년부터 2014년까지 한반도 지역 발생 지진을 중심으로)

  • Min, Dongmin;Oh, Seokhoon;Ji, Yoonsoo
    • Journal of the Korean earth science society
    • /
    • v.36 no.7
    • /
    • pp.649-660
    • /
    • 2015
  • This study aimed at the correlation analysis of geomagnetic variations related to earthquakes which occurred in and around the Korean Peninsula from 2012 to 2014. The wavelet-based semblance technique was used to confirm the geomagnetic variations related to earthquakes. As a result, a pattern of consistent geomagnetic variations in total magnetic has been found from the earthquakes occurred within 100 km radius around the observation site. A similar correlation between earthquake location and Z-field geomagnetic data was also confirmed by the wavelet-based semblance analysis. We mainly used the high quality geomagnetic measurements from the Cheongyang Observatory and additionally used the data from the Bohyunsan Observatory in order to validate the correlation between earthquake and Z-field geomagnetic data.

Tunnel Magnetoresistance with Plasma Oxidation Time in Double Oxidized Barrier Process (2단계 AlOx 절연층 공정에서 하부절연층의 산화시간에 따른 터널자기저항 특성연구)

  • Lee, Young-Min;Song, Oh-Sung
    • Korean Journal of Materials Research
    • /
    • v.12 no.3
    • /
    • pp.200-204
    • /
    • 2002
  • We fabricated TMR devices which have double oxidized tunnel barrier using plasma oxidation method to form homogeneously oxidized AlO tunnel barrier. We sputtered 10 $\AA$-bottom Al layer and oxidized it by varying oxidation time for 5, 10, 20 sec. Subsequent sputtering of 13 $\AA$ - Al was performed and the matallic layer was oxidized for 120 sec. The electrical resistance changed from 700$\Omega$ to 2700$\Omega$ with increase of oxidation time, while variation of MR ratio was little spreading 27~31% which is larger than that of TMR device of ordinary single tunnel barrier. We calculated effective barrier height and width by measuring I-V curves, from which we found the barrier height was 1.3~1.5 eV, sufficient for tunnel barrier, and the barrier width(<16.2 $\AA$) was smaller than that of directly measured value by the tunneling electron microscopy. Our results may be caused by insufficient oxidation of Al precursor into $Al_2O_3$. However, double oxidized tunnel barriers were superior to conventional single tunnel barrier in uniformity and density. We found that the external magnetic field to switch spin direction of ferromagnetic layer of pinned layer breaking ferro-antiferro exchange coupling was increased as bottom layer oxidation time increased. Our results imply that we were able to improve MR ratio and tune switching field by employing double oxidized tunnel barrier process.

A Study on Analysis Technique for Solenoid Valve Applicable to Military Vehicle Transmission (군용차량 변속기에 적용할 수 있는 솔레노이드밸브 해석기술에 관한 연구)

  • Choi, Yun-Yong;Hong, Jung-Pyo
    • Journal of the Korea Society for Simulation
    • /
    • v.24 no.4
    • /
    • pp.29-34
    • /
    • 2015
  • Electronic of military vehicle that had relied on pure machinery system is ongoing. A large part of electronic of small-sized military vehicle has been already commercialized, which will expand to large-sized military vehicle field. Design of solenoid valve for automatic transmission is significantly important for stable driving performance of military vehicle. This research aims to develop simulation method which is capable of predicting performance of solenoid valve quantitatively according to its variation of ATF temperature. The research has been conducted in line with Maxwell, a magnetic field analysis program, and AMESim, a hydraulic analysis program. After simulation, it turned out to have been very similar to the test result in temperature range which excludes high temperature (over $120^{\circ}C$) and extremely low temperature (below $-20^{\circ}C$).