Effective of Body Temperature Increasing during Brain MRI scan (MRI 검사 시 체온상승 효과: 1.5 T vs 3.0 T)

  • Kim, Myeong Seong;Lee, Jongwoong;Jung, Jaeeun
    • Journal of the Korean Society of Radiology
    • /
    • v.11 no.1
    • /
    • pp.49-54
    • /
    • 2017
  • As the Radiofrequency(RF) increases with the magnetic field strength, the wavelength of the RF excitation field becomes smaller, which leads to more the thermal effect in the human-body placed in the electric field. MRI scanner used was GE signa 1.5T, HDx 3.0T and Philips 3.0T with same routine clinical sequence protocol. Therefore temperature was measured before and after each scan. Taken the temperatures in the ear with ear infra-red type thermometer(Braun co). 3.0T were temperature increases more than $0.15^{\circ}C$ and GE 3.0T MRI equipment about $0.14^{\circ}C$ higher than the Philips 3.0T MRI(p<0.012). Psychogenic status was investigated by the survey respondents about their status can not just answer therefore, a little different from the expected. In our study of Thermal effect of clinical MRI with clinical protocol sequence, we found that the 3.0T in the body-temperature rise was greater than the 1.5T. Therefore, in clinical 3.0T examine the dangerous situation caused by the temperature rise occurred (burns, impaired thermoregulatory mechanism in patients with high-temperature damage, exhaustion occurs due to excessive sweating), not to appear the more watched the patient's condition with procedure.

Development of Semi-active Damper by Magneto-Rheological Fluid (자기 유변 유체를 이용한 반능동 감쇠기의 개발)

  • 정병보;권순우;김상화;박영진
    • The Korean Journal of Rheology
    • /
    • v.11 no.2
    • /
    • pp.105-111
    • /
    • 1999
  • Dampers have been used to dissipate energy in mechanical systems. There are several types of dampers such as passive, active, and semi-active damper. Semi-active dampers have higher performance than passive ones and require less power to operate than active ones. Their damping characteristics can be changed properly for varying conditions. In this paper, we investigated the semi-active damper using Magneto-Rheological fluid. Magneto-Rheological fluid, which is one of controllable fluids, changes its damping and rheological characteristics from Newtonian fluid to Bingham fluid as the magnetic field is applied. It has several advantages such as high yield strength, low viscosity, robustness to impurities and wide temperature range of stability. If we designe a semi-active damper by using this material, we can not only design a simply structured damper but also expect rapid response. In this study, we propose several types of semi-active dampers which are designed and manufactured using Magneto-Rheological fluid and some problems encountered during their applications.

  • PDF

COSMIC RAY SPECTRUM IN SUPERNOVA REMNANT SHOCKS

  • Kang, Hye-Sung
    • Journal of The Korean Astronomical Society
    • /
    • v.43 no.2
    • /
    • pp.25-39
    • /
    • 2010
  • We perform kinetic simulations of diffusive shock acceleration (DSA) in Type Ia supernova remnants (SNRs) expanding into a uniform interstellar medium (ISM). Bohm-like diffusion due to self-excited $Alfv\acute{e}n$ waves is assumed, and simple models for $Alfv\acute{e}nic$ drift and dissipation are adopted. Phenomenological models for thermal leakage injection are considered as well. We find that the preshock gas temperature is the primary parameter that governs the cosmic ray (CR) acceleration efficiency and energy spectrum, while the CR injection rate is a secondary parameter. For SNRs in the warm ISM of $T_0\lesssim10^5K$, if the injection fraction is $\xi\gtrsim10^{-4}K$, the DSA is efficient enough to convert more than 20% of the SN explosion energy into CRs and the accelerated CR spectrum exhibits a concave curvature flattening to $E^{-1.6}$, which is characteristic of CR modified shocks. Such a flat source spectrum near the knee energy, however, may not be reconciled with the CR spectrum observed at Earth. On the other hand, SNRs in the hot ISM of$T_{0}\approx10^{6}K$ with a small injection fraction, $\xi$<$10^{-4}$, are inefficient accelerators with less than 10% of the explosion energy getting converted to CRs. Also the shock structure is almost test-particle like and the ensuing CR spectrum can be steeper than $E^{-2}$. With amplified magnetic field strength of order of $30{\mu}G$ $Alfv\acute{e}n$ waves generated by the streaming instability may drift upstream fast enough to make the modified test-particle power-law as steep as $E^{-2.3}$, which is more consistent with the observed CR spectrum.

Design of Speed-Variable Driving System and Tester for Electric Forklift Truck (전동지게차용 변속 구동부 및 시험기 설계)

  • Shim, J.H.;Kang, H.K.;Ham, S.H.;Oh, S.H.
    • Journal of Power System Engineering
    • /
    • v.12 no.3
    • /
    • pp.38-43
    • /
    • 2008
  • The usage of electric forklift truck is gradually increasing due to the convenience at conveying and arranging the materials in the industrial field. In this study, the author designed and suggested the optimum driving system and load tester which both of them are the most important part of the forklift truck. The planetary gear is chose to driving system because it makes big power even though the motor size is small. The gear teeth of planetary gear were designed and the designed planetary gear was tested considering the yield strength and the abrasion of gear teeth. The B-Type electric brake which consists of multiple plates and operates with non-magnetic type was connected with a single shaft in the driving system. So, it can be applied at the sudden braking situation which has the torque increment. And it has the compact size and excellent durability Load tester can give the various levels of load to the planetary gear of driving system in the electric forklift truck and it can also measure the levels of the load which were applied. Therefore, we can measure the noise, torque and perform the durability, vibration tests using load tester. It will be economical because many kinds of test can be performed using reasonable priced load tester The driving system of electric forklift truck which has sufficient competitive can be manufactured using our designed planetary gear reducer with reasonable price. The designed load tester can use for checking the performance of other reducers, as well.

  • PDF

Spatial and Directional Sensation Prosthesis for the Blind (시각장애인을 위한 공간 및 방향감각 보조시스템)

  • 노세현;박우찬;신현철;김상호;김영곤;김광년;정동근
    • Journal of Biomedical Engineering Research
    • /
    • v.25 no.2
    • /
    • pp.145-150
    • /
    • 2004
  • In this study for the prosthesis of the spatial and directional sensation for the blind, an ultrasonic scale system and an electronic compass system were developed. The ultrasonic scale utilizes 40 ㎑ sound for the detection of distance to the barrier and the spatial information is transferred to the blind by various sound interval, which is proportional to the distance. The electronic compass utilizes a magnetoresistor bridge for the detection of the magnetic field strength of earth in horizontal plane. The information for the direction of the earth's north is transferred by tactile stimuli by a vibrating motor band around upper head. Detection distance of the ultrasonic scale is ranged from 0.065 to 3.26 meters, and the detection angle resolution of the electronic compass is about 22.5 degrees. The integrated system of the ultrasonic scale and the electronic compass was developed. Distance information is converted to the location of the tactile stimulation along the clockwise direction by a vibrating motor according to the distance installed around upper head of the blind. The intent of this article is to provide an practical prosthetic tool of spatial and directional sensation for the blind. Daily practice of this system will improve the usefulness of this system.

Effect of weak interlayer coupling on critical fluctuation in high $T_c$ superconductors

  • Kim, Jin-Tae;Kang, W.N.;Chung, S.H.;Ha, D.H.;Yoo, K.H.;Kim, M.S.;Lee, Sung-Ik;Park, Y.K.;Park, J.C.
    • Progress in Superconductivity
    • /
    • v.1 no.1
    • /
    • pp.1-8
    • /
    • 1999
  • The magnetization and/or resistivity of high $T_c$ superconductors ($YBa_2Cu_3O_{7-\delta}$(YBCO) single crystal, $Bi_2Sr_2CaCu_2O_8$ (Bi-2212) single crystal, $Tl_2Ba_2CaCu_2O_8$ (Tl-2212) film, $HgBa_2Ca_2Cu_3O_8$ (Hg-1223) film) have been measured as a function of magnetic field H and temperature T. The extracted fluctuation part of the magnetization and conductivity exhibits a critical behavior consistent with the three-dimensional XY model. The dynamic critical exponent z does not sensitively vary with a type of the superconductors. The value of z ranges from 1.5 to $1.8{\pm}0.1$. However, the static critical exponent ${\nu}$ is the most largely increased in Tl-2212 that has a weaker interlayer coupling strength than YBCO; the value of ${\nu}$ is 0.669, 0.909, 1.19, and 1.338 for YBCO, Bi-2212, Hg-1223, and Tl-2212 respectively. The results indicate that the weak interlayer coupling along the c-axis of high $T_c$ superconductors near $T_c$ does not influence the dynamic critical exponent z (the same value of superfluid $^4He$), but significantly increases the static critical exponent ${\nu}$.

  • PDF

Study on EMI Elimination and PLN Application in ELF Band for Romote Sensing with Electric Potentiometer (전위계차 센서를 이용한 원격센싱을 위한 ELF 대역 EMI 제거 및 PLN 응용 연구)

  • Jang, Jin Soo;Kim, Young Chul
    • Smart Media Journal
    • /
    • v.4 no.1
    • /
    • pp.33-38
    • /
    • 2015
  • In this paper, we propose the methods not only to eliminate ELF(Extremely Low Frequency) EMI(Electro-Magnetic Interference) noice for extending recognition distance, but also to utilize the the PLN for detecting starting instance of a hand gesture using electric potential sensor. First, we measure strength of electric field generated in the smart devices such as TV and phone, and minimize EMI through efficient arrangement of the sensors. Meanwhile, we utilize the 60 Hz PLN to extract the starting point of hand gesture. Thereafter, we eliminate the PLN generated in the smart device and circuit of sensors. And then, we shield the sensors from an electric noise generated from devices. Finally, through analyzing the frequency components according to the gesture of target, we use the low pass filter and the Kalman filter for elimination of remaining electric noise. We analyze and evaluate the proposed ELF-band EMI eliminating method for non-contact remote sensing of the EPS(Electric Potential Sensor). Combined with a detecting technique of gesture starting point, the recognition distance for gestures has been proven to be extended to more than 3m, which is critical for real application.

RADIO EMISSION FROM WEAK SPHERICAL SHOCKS IN THE OUTSKIRTS OF GALAXY CLUSTERS

  • Kang, Hyesung
    • Journal of The Korean Astronomical Society
    • /
    • v.48 no.2
    • /
    • pp.155-164
    • /
    • 2015
  • In Kang (2015) we calculated the acceleration of cosmic-ray electrons at weak spherical shocks that are expected to form in the cluster outskirts, and estimated the diffuse synchrotron radiation emitted by those electrons. There we demonstrated that, at decelerating spherical shocks, the volume integrated spectra of both electrons and radiation deviate significantly from the test-particle power-laws predicted for constant planar shocks, because the shock compression ratio and the flux of inject electrons decrease in time. In this study, we consider spherical blast waves propagating through a constant density core surrounded by an isothermal halo with ρ ∝ r−n in order to explore how the deceleration of the shock affects the radio emission from accelerated electrons. The surface brightness profile and the volumeintegrated radio spectrum of the model shocks are calculated by assuming a ribbon-like shock surface on a spherical shell and the associated downstream region of relativistic electrons. If the postshock magnetic field strength is about 0.7 or 7 µG, at the shock age of ∼ 50 Myr, the volume-integrated radio spectrum steepens gradually with the spectral index from αinj to αinj + 0.5 over 0.1–10 GHz, where αinj is the injection index at the shock position expected from the diffusive shock acceleration theory. Such gradual steepening could explain the curved radio spectrum of the radio relic in cluster A2266, which was interpreted as a broken power-law by Trasatti et al. (2015), if the relic shock is young enough so that the break frequency is around 1 GHz.

A Study on the Electronic Properties and Electrochemical Behavior of Rare Earch Metal(Ⅲ) Complexes (Ⅲ) (희토류금속(Ⅲ) 착물들의 전자적 성질과 전기화학적 거동에 관한 연구 (Ⅲ))

  • Choe, Chil Nam;Son, Hyo Yeol
    • Journal of the Korean Chemical Society
    • /
    • v.38 no.8
    • /
    • pp.590-597
    • /
    • 1994
  • The chemical behavior of the trivalent lanthanide$(Pr^{3+}, Eu^{3+}, Gd^{3+} 그리고 Yb^{3+})$complexes with organo-ligand (2,2,6,6-tetramethyl-3,5-heptanedione) has been investigated by the use of UV/Vis-spectrophotometric, magnetics, and electrochemical method. The two or three energy absorption bands are observed by the spectra of these complexes. The magnetitude of crystal field splitting energy, the spin pairing energy and bond stength was obtained from the spectra of the complexes. These are found to be localization, low-spin (or high-spin state, and strong bonding strength. The magnetic dipole moment are found to be diamagnetic complexes (or paramagnetic). The electrochemical behavior of complexes was observed by the use of cyclic voltammetry in aprotic media. These reduction peaks were irreversible two and three step reduction processes by electron transfer.

  • PDF

Design of a Non-Invasive Blood Glucose Sensor Using a Magneto-Resonance Absorption Method (자기공명흡수법에 의한 무혈혈당측정기의 디자인)

  • Kim Dong-Kyun;Won Jong-Hwa;Potapov Sergey N.;Protasov Evgeniy A.
    • Journal of the Institute of Electronics Engineers of Korea SC
    • /
    • v.42 no.2 s.302
    • /
    • pp.33-38
    • /
    • 2005
  • In this paper, the sensing unit of a non-invasive blood glucose sensor for home users, using a magneto-resonance absorption method, have been designed and manufactured. The sensor is capable of non-invasively determining blood glucose levels through measuring the 1H spin-lattice relaxation time in human body, The comparison of initial models, with different dimensions and shapes, for the sensing unit has led us to select the materials of the final model, which has adequate size and weight for home use. Through the design optimization using the FEM model, the dimension of final model has been determined to satisfy the required strength and uniformity of the magnetic field in the detecting area.