• Title/Summary/Keyword: magnetic field interference

Search Result 99, Processing Time 0.025 seconds

Magnetic Properties of Transition Metal-implanted ZnO Nanotips Grown on Sapphire and Quartz

  • Raley, Jeremy A.;Yeo, Yung-Kee;Hengehold, Robert L.;Ryu, Mee-Yi;Lu, Yicheng;Wu, Pan
    • Journal of Magnetics
    • /
    • v.13 no.1
    • /
    • pp.19-22
    • /
    • 2008
  • ZnO nanotips, grown on c-$Al_2O_3$ and quartz, were implanted variously with 200 keV Fe or Mn ions to a dose level of $5{\times}10^{16}cm^{-2}$. The magnetic properties of these samples were measured using a superconducting quantum interference device (SQUID) magnetometer. Fe-implanted ZnO nanotips grown on c-$Al_2O_3$ showed a coercive field width of 209 Oe and a remanent field of 12% of the saturation magnetization ($2.3{\times}10^{-5}emu$) at 300K for a sample annealed at $700^{\circ}C$ for 20 minutes. The field-cooled and the zero-field-cooled magnetization measurements also showed evidence of ferromagnetism in this sample with an estimated Curie temperature of around 350 K. The Mn-implanted ZnO nanotips grown on c-$Al_2O_3$ showed superparamagnetism resulting from the dominance of a spin-glass phase. The ZnO nanotips grown on quartz and implanted with Fe or Mn showed signs of ferromagnetism, but neither was consistent.

Analysis of Electromagnetic Wave Absorbers for Applying Magnetic Levitation (자기부상체 적용을 위한 전자파 흡수체의 특성 분석)

  • Seo, Yong-beom;Kang, Hyun-il
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.65 no.1
    • /
    • pp.13-17
    • /
    • 2016
  • EMC (Electro Magnetic Compatibility) of the electrical railway must be ensured for safety of passenger. Maglev trains has not friction between the wheels and the rails because levitation by an permanent magnets, electromagnets and superconducting magnets etc. So, it is advantageous to maintain a high speed without noise and vibrations. In this paper, we investigated that the magnetic field of the before and after installation electromagnetic waves absorber in order to analyze the effects of electromagnetic waves. The theoretical analysis of the electromagnetic wave absorber was simulated using finite element method. The magnetic field properties of electromagnetic waves absorber were measured by EMI (Electro Magnetic Interference) test receiver.

Magnetic Interaction in FeCo Alloy Nanotube Array

  • Zhou, D.;Wang, T.;Zhu, M.G.;Guo, Z.H.;Li, W.;Li, F.S.
    • Journal of Magnetics
    • /
    • v.16 no.4
    • /
    • pp.413-416
    • /
    • 2011
  • An array of FeCo nanotubes has been successfully fabricated in the pores of porous anodic aluminum oxide (AAO) templates by wetting templates method. The morphology and structure of the nanotube array were characterized by scanning electron microscopy, transmission electron microscopy and x-ray diffraction. The average diameter of the nanotubes was about 200 nm, and the length was more than 10 ${\mu}m$. Vibrating sample magnetometer and superconducting quantum interference device were used to investigate the magnetic properties of the nanotube array. Interaction between the nanotubes has been found to be demagnetizing as expected and the switching field distribution is broad.

Emulator Circuit for a Flux Locked Loop for Detection of Magnetocardiography Signal (심자도 신호 검출을 위한 Flux Locked Loop (FLL) Emulation 회로)

  • 안창범;이동훈;김인기;장경섭;김기태;정동현;최중필
    • Proceedings of the IEEK Conference
    • /
    • 2003.07c
    • /
    • pp.2749-2752
    • /
    • 2003
  • Magnetocardiography is a very weak biomagnetic field generated from the heart. Since the magnitude of the biomagnetic field is in the order of a few pico Tesla, it is measured with a superconducting quantum interference device (SQUID). SQUID is a transducer converting magnetic flux to voltage, however, its range of linear conversion is very restricted. In order to overcome the narrow dynamic range. a flux locked loop is used to feedback the output field with opposite polarity to the input field so that the total Held becomes zero. This prevents the operating point of the SQUID from moving too far away from the null point thereby escape from the linear region. In this paper, an emulator for the SQUID sensor and feedback coil is proposed. Magnetic courting between the original field and the generated field by the feedback coil is emulated by electronic circuits. By using the emulator, FLL circuits are analyzed and optimized without SQUID sensors. The emulator may be used as a test signal for multi-channel gain calibration and system maintenance.

  • PDF

Fused Navigation of Unmanned Surface Vehicle and Detection of GPS Abnormality (무인 수상정의 융합 항법 및 GPS 이상 검출)

  • Ko, Nak Yong;Jeong, Seokki
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.22 no.9
    • /
    • pp.723-732
    • /
    • 2016
  • This paper proposes an approach to fused navigation of an unmanned surface vehicle(USV) and to detection of the outlier or interference of global positioning system(GPS). The method fuses available sensor measurements through extended Kalman filter(EKF) to find the location and attitude of the USV. The method uses error covariance of EKF for detection of GPS outlier or interference. When outlier or interference of the GPS is detected, the method excludes GPS data from navigation process. The measurements to be fused for the navigation are GPS, acceleration, angular rate, magnetic field, linear velocity, range and bearing to acoustic beacons. The method is tested through simulated data and measurement data produced through ground navigation. The results show that the method detects GPS outlier or interference as well as the GPS recovery, which frees navigation from the problem of GPS abnormality.

The Electro-Magnetic Susceptibility Test Method of a Road Vehicle Considering the Field Uniformity (전계의 균일성을 고려한 자동차의 전자파 내성시험 방법에 관한 연구)

  • Bae, Min-Gwan;Shin, Jae-Kon;Yong, Gee-Joong;Woo, Hyun-Gu
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.18 no.4
    • /
    • pp.84-91
    • /
    • 2010
  • Owing to revolutionary developments in automobile technologies, a variety of advanced vehicles - hybrid vehicle, hydrogen fuel-cell vehicle, electric vehicle, etc. - emerges recently. The safety is getting more important for developing automobiles. The electro-magnetic compatibility has to be assured, since those advanced vehicles are equipped with various new electronic systems. Electro-magnetic compatibility tests, in general, consist of an EMI(electro-magnetic interference) test and an EMS (electro-magnetic susceptibility) test. We investigated the susceptibility test method suggested in KMVSS (Korean Motor Vehicle Safety Standard) as the EMS test method. A series of experiments results that the above test method should be partially revised to comply with a Korean governmental standard method. In this paper, the some directions of modifications are presented to enhance the quality of the above EMS test method.

Analysis of a CubeSat Magnetic Cleanliness for the Space Science Mission (우주과학임무를 위한 큐브위성 자기장 청결도 분석)

  • Jo, Hye Jeong;Jin, Ho;Park, Hyeonhu;Kim, Khan-Hyuk;Jang, Yunho;Jo, Woohyun
    • Journal of Space Technology and Applications
    • /
    • v.2 no.1
    • /
    • pp.41-51
    • /
    • 2022
  • CubeSat is a satellite platform that is widely used not only for earth observation but also for space exploration. CubeSat is also used in magnetic field investigation missions to observe space physics phenomena with various shape configurations of magnetometer instrument unit. In case of magnetic field measurement, the magnetometer instrument should be far away from the satellite body to minimize the magnetic disturbances from satellites. But the accommodation setting of the magnetometer instrument is limited due to the volume constraint of small satellites like a CubeSat. In this paper, we investigated that the magnetic field interference generated by the cube satellite was analyzed how much it can affect the reliability of magnetic field measurement. For this analysis, we used a reaction wheel and Torque rods which have relatively high-power consumption as major noise sources. The magnetic dipole moment of these parts was derived by the data sheet of the manufacturer. We have been confirmed that the effect of the residual moment of the magnetic torque located in the middle of the 3U cube satellite can reach 36,000 nT from the outermost end of the body of the CubeSat in a space without an external magnetic field. In the case of accurate magnetic field measurements of less than 1 nT, we found that the magnetometer should be at least 0.6 m away from the CubeSat body. We expect that this analysis method will be an important role of a magnetic cleanliness analysis when designing a CubeSat to carry out a magnetic field measurement.

A Study on the MEG Imaging (MEG 영상진단 검사에 관한 연구)

  • Kim, Jong-Gyu
    • Korean Journal of Clinical Laboratory Science
    • /
    • v.37 no.2
    • /
    • pp.123-128
    • /
    • 2005
  • Magnetoencephalography (MEG) is the measurement of the magnetic fields produced by electrical activity in the brain, usually conducted externally, using extremely sensitive devices such as Superconducting Quantum Interference Device (SQUID). MEG needs complex and expensive measurement settings. Because the magnetic signals emitted by the brain are on the order of a few femtoteslas (1 fT = 10-15T), shielding from external magnetic signals, including the Earth's magnetic field, is necessary. An appropriate magnetically shielded room is very expensive, and constitutes the bulk of the expense of an MEG system. MEG is a relatively new technique that promises good spatial resolution and extremely high temporal resolution, thus complementing other brain activity measurement techniques such as electroencephalography (EEG), positron emission tomography (PET), single-photon emission computed tomography (SPECT) and functional magnetic resonance imaging (fMRI). MEG combines functional information from magnetic field recordings with structural information from MRI. The clinical uses of MEG are in detecting and localizing epileptic form spiking activity in patients with epilepsy, and in localizing eloquent cortex for surgical planning in patients with brain tumors. Magnetoencephalography may be used alone or together with electroencephalography, for the measurement of spontaneous or evoked activity, and for research or clinical purposes.

  • PDF

Electromagnetic Fields in General Hospital (의료기관 내 전자파 환경)

  • Shin, Sei-One;Yun, Sang-Mo;Shin, Hyoun-Jin;Ahn, Hyun-Soo;Ahn, Hee-Deok
    • Journal of Yeungnam Medical Science
    • /
    • v.21 no.2
    • /
    • pp.167-176
    • /
    • 2004
  • Background: Electromagnetic fields (EMF) are ubiquitous in modern society including medical field. As the technology of medical instruments and telecommunications has developed rapidly, it has influenced on our lives in many ways. Modern medical practice requires high quality medical equipments, which have a great deal of electromagnetic interference and susceptibility. The purpose of this study were to evaluate electromagnetic condition under usual clinical condition and to suggest a practical guideline in general hospital. Materials and Methods: The actual state of the electromagnetic interference in the medical field was studied under usual clinical conditions including operating rooms, intensive care units, magnetic resonance imaging unit, and hyperthermia unit. Results: There was considerable noise as a result of electromagnetic fields from medical equipments including electrosurgical units and hyperthermia unit, and cellular phones, which could induce serious functional derangements of functioning medical devices. Conclusion: It will be necessary to evaluate the individual electromagnetic situations under various medical conditions and to define a limited zone for cellular phone as well as reposition medical equipments to secure a safer medical practice and to minimize electromagnetic interference.

  • PDF

Decision of Optimal Magnetic Field Shielding Location around Power System Using Evolution Strategy Algorithm (Evolution Strategy 알고리즘을 이용한 송진선로 주변에서의 최적 자계차폐 위치선정)

  • Choe, Se-Yong;Na, Wan-Su;Kim, Dong-Hun;Kim, Dong-Su;Lee, Jun-Ho;Park, Il-Han;Sin, Myeong-Cheol;Kim, Byeong-Seong
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.51 no.1
    • /
    • pp.5-14
    • /
    • 2002
  • In this paper, we analyze inductive interference in conductive material around 345 kV power transmission line, and evaluate the effects of mitigation wires. Finite element method (FEM) is used to numerically compute induced eddy currents as well as magnetic fields around powder transmission lines. In the analysis model, geometries and electrical properties of various elements such as power transmission line, buried pipe lines, overhead ground wire, and conducting earth are taken into accounts. The calculation shows that mitigation wire reduces fairly good amount of eddy currents in buried pipe line. To find the optimum magnetic field shielding location of mitigation wire, we applied evolution strategy algorithm, a kind of stochastic approach, to the analysis model. Finally, it was shown that we can find more effective shielding effects with optimum location of one mitigation wire than with arbitrary location of multi-mitigation wires around the buried pipe lines.