• Title/Summary/Keyword: magnetic field interference

검색결과 99건 처리시간 0.022초

송전선에서 발생되는 자계에 의한 유도장해 해석 (Analysis of the influence of magnetic field generated from power transmission on the inductance interference)

  • 최세용;나완수;최명준;이세희;김동수;박일한;신명철
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2000년도 하계학술대회 논문집 C
    • /
    • pp.1993-1995
    • /
    • 2000
  • In this paper, we calculate the magnetic field and analyze the inductive interference in conductive material around power transmission line. To compute induced eddy currents as well as magnetic fields, finite element method(FEM) is used for numerical calculation. The characteristics, transmission line height, conductive earth and mitigation wire are taken account of FEM analysis. This research also shows that mitigation wire reduces amount of eddy current in buried pipe line.

  • PDF

과전류 계측을 위한 광자계센서의 구현 (Implementation of Optical Magnetic Field Sensor for Measurement of Over Current)

  • 박해수;노종대;김요희;박병석;안성준;조홍근
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1997년도 하계학술대회 논문집 E
    • /
    • pp.1871-1873
    • /
    • 1997
  • The conventional current transformers are often take faults and out of order that for detect to over current of electric power lines because electromagnetic interference. But, it is possible to implement protection relay of high reliability using optical magnetic field sensor which are immunity and small size. The optical magnetic field sensor is possible to rapidly detect to over current and recover when electric power line have fault. And it is not necessary to make with capacitance of electric power lines as optical magnetic field sensor is have linearity from 0 to about 20kA. In this study, we designed and constructed compensative feedback circuit in order to minimize of optical power intensity variation with environ- mental variations(temperature, drive current) of light source. And this system have highest optical advantages and reliability.

  • PDF

The latest trend in magnetocardiogram measurement system technology

  • Lee, Y.H.;Kwon, H.;Kim, J.M.;Yu, K.K.
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제22권4호
    • /
    • pp.1-5
    • /
    • 2020
  • Heart consists of myocardium cells and the electrophysiological activity of the cells generate magnetic fields. By measuring this magnetic field, magnetocardiogram (MCG), functional diagnosis of the heart diseases is possible. Since the strength of the MCG signals is weak, typically in the range of 1-10 pT, we need sensitive magnetic sensors. Conventionally, superconducting quantum interference devices (SQUID)s were used for the detection of MCG signals due to its superior sensitivity to other magnetic sensors. However, drawback of the SQUID is the need for regular refill of a cryogenic liquid, typically liquid helium for cooling low-temperature SQUIDs. Efforts to eliminate the need for the refill in the SQUID system have been done by using cryocooler-based conduction cooling or use of non-cryogenic sensors, or room-temperature sensors. Each sensor has advantage and disadvantage, in terms of magnetic field sensitivity and complexity of the system, and we review the recent trend of MCG technology.

Interference Issuses of Radio Frequency Identification Devices in Magnetic Resonance Imaging Systems and Computed Tomography Scan

  • Periyasamy, M.;Dhanasekaran, R.
    • Journal of Magnetics
    • /
    • 제20권3호
    • /
    • pp.295-301
    • /
    • 2015
  • We evaluated certain issues related to magnetic resonance imaging (MRI) coupled with the use of active 2.5 GHz radio frequency identification (RFID) tags for patient identification using low field (0.3 T) MRI and computed tomography (CT) scans. We also investigated the performance of the RFID reader located outside the MRI room by considering several factors. A total of ten active RFID tags were exposed to several MRI sequences and X-rays of CT scan. We found that only card type active RFID tags are suitable for patient identification purpose in MRI environment and both wristbands as well as card tags were suitable for the same in CT environment. Severe artifacts were found in the captured MRI and CT images when the area of the imaging was in proximity to the tags. No external factors affected the performance of active RFID reader stationed outside the MRI scan room.

Magnetic Anisotropy Energy Distribution and Magnetization of CoPt Nanoparticles Encaged in Protein Shell

  • Lee, T.H.;Suh, B.J.;Jang, Z.H.
    • Journal of Magnetics
    • /
    • 제22권1호
    • /
    • pp.1-6
    • /
    • 2017
  • Magnetic properties of CoPt nanoparticles (average size = 2.1 nm) encapsulated in synthesized protein shell have been investigated with SQUID (Superconducting Quantum Interference Device) magnetometer and analyzed by the recently developed non-equilibrium magnetization calculation by our group [T. H. Lee et al., Phys. Rev. B 90, 184411 (2014)]. Field dependence of magnetization measured at 2 K was successfully analyzed with modified Langevin function. In addition, small hysteresis loops having the coercive field of 890 Oe were observed at 2 K. Temperature dependence of magnetization has been measured with zero field cooled (ZFC) and field cooled (FC) protocol with slightly modified sequence in accordance with non-equilibrium magnetization calculation. The analysis on the M vs. T data revealed that the anisotropy energy barrier distribution is found to be very different from the log-normal distribution found in a size distribution. Zero temperature coercive field and Bloch coefficient have also been extracted from the analysis and the validity of those values is checked.

고감도 단금속 및 쌍금속 표면 플라즈몬 공명 센서 설계를 위한 수치해석 연구 (Numerical Investigation on Surface Plasmon Resonance Sensor Design with High Sensitivity Using Single and Bimetallic Film Structures)

  • 권혁록;이성혁
    • 전기학회논문지
    • /
    • 제58권4호
    • /
    • pp.795-800
    • /
    • 2009
  • Surface plasmon resonance (SPR) has been widely used for biological and chemical sensing applications. The present study investigates numerically the optical characteristics for the single Au film and bimetallic Ag/Au film SPR configurations by using the multiple beam interference matrix (MBIM) method. We use the prism coupling method, especially Kretschmann configuration for excitation of surface plasmon wave (SPW). The estimated results of reflectance, phase shift and magnetic field intensity enhancement factor are provided for finding out the optimum configuration with high sensitivity for SPR measurement. As a result, the optimum thicknesses are found to be 52 nm for a single Au film and 5 nm to 36 nm for bimetallic Ag-Au film. From the comparison of full width half maximum (FWHM) values for reflectance, phase shift, and enhancement of magnetic field intensity, it is concluded that the highest sensitivity can be obtained when using the phase shift for SPR sensor.

가선전류에 의한 자기장 형성과 수동루프를 이용한 전기철도차량내 자기장 유도 감쇄 분석 (Analysis of Magnetic Field by Catenary Current and Magnetic Field Mitigation in Electric Railway using Passive Loop)

  • 윤여근;나완수;한인수;이태형;박춘수
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2011년도 춘계학술대회 논문집
    • /
    • pp.384-389
    • /
    • 2011
  • The electric railway cars are operated by high voltage supply through the catenary wire. Also, numerous electric equipments operated by electric signal are distributed in the electric railway cars. Such electric equipments are exposed to EMI/EMC problems, and there is the possibility that the magnetic field due to the catenary wire current takes effect on the electromagnetic field in the electric railway cars which move under the catenary wire. There is the possibility that the electromagnetic interference generates in view of the operation of many electric equipments in the electric railway cars. There is the possibility that the communication device faults generate, and that the hazards on the human beings generate. In this paper, we predict the magnetic field around the catenary wire, and obtain the exact magnetic field distribution by comparing the analytic results and the numerical results. Finally, we confirmed the possibility of the passive loop mitigation by comparing the analytic results and the numerical results through the passive loop mitigation technique.

  • PDF

SSFPI 기법을 이용한 MR 뇌기능 영상 -고 속의 자화율 효과의 직접적인 측정 (SSFP Interferometry (SSFPI) Technique Applied to functional MRI - A Fast and Direct Measurement of Magnetic Susceptibility Effect)

  • 정준영
    • 대한의용생체공학회:의공학회지
    • /
    • 제17권4호
    • /
    • pp.525-534
    • /
    • 1996
  • We have developed a fast steady state free precession interferometry (SSFPI) technique which is useful for the fMRl (functional Magnetic Resonance Imaging). As is known, SSFP sequence with a suitable adjustment of Vadient (readeut) allows us to measure precession angle 6 which in tw relates to the field inhomogeneity. Combining the two pulses (known as FID and Echo) in FADE (Fast Acquisition Double Echo) sequence, for example, one can obtain the interference term which is directly related to the precession angle It has been known that a fast high resolution magnetic field mapping is possible by use of the modified FADE sequence or SSFPI, and we have attempted to use the SSFPI technique for the susceptibility-induced fMRl. When the method is applied to the susceptibility effect based functional magnetic resonance imaging (fMRl), it was found that the direct susceptibility effect measurement was possible without perturbations such as the backgrounds and inflow effect. In this paper, simulation results and experimental results obtained with 2.0 Tesla MRI system are presented.

  • PDF

동력 분산형 고속철도용 변압기의 출력 간섭현상을 저감시키기 위한 권선 배치 방법 (Winding Disposition to Minimize the Output Interference of Transformers for the High-Speed EMU)

  • 박병건;안성국;현동석
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2010년도 춘계학술대회 논문집
    • /
    • pp.1873-1877
    • /
    • 2010
  • In the high-speed EMU, the modularized traction converter produces the significant harmonic currents caused from the switching behavior of a power converter. These harmonic currents bring the interference among the traction equipment. One way to minimize the interference is to design the secondary windings of a power transformer decoupled magnetically as possible. This paper presents a magnetic field analysis on a winding disposition to clarify an impact on magnetic decoupling between secondary windings, under a limited height of a train. Two winding dispositions for a single-phase shell-type transformer are constructed and simulated by a three-dimensional finite elements method (FEM) model. Two different winding dispositions are constructed and simulated by three-dimensional FEM model using Maxwell3D.

  • PDF

Gain characteristics of SQUID-based RF amplifiers depending on device parameters

  • Lee, Y.H.;Yu, K.K.;Kim, J.M.;Lee, S.K.;Chong, Y.;Oh, S.J.;Semertzidis, Y.K.
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제21권1호
    • /
    • pp.10-14
    • /
    • 2019
  • Radio-frequency (RF) amplifiers based on direct current (DC) superconducting quantum interference device (SQUID) have low-noise performance for precision physics experiments. Gain curves of SQUID RF amplifiers depend on several parameters of the SQUID and operation conditions. We are developing SQUID RF amplifiers for application to measure very weak RF signals from ultra-low-temperature high-magnetic-field microwave cavity in axion search experiments. In this study, we designed, fabricated and characterized SQUID RF amplifiers with different SQUID parameters, such as number of input coil turn, shunt resistance value of the junction and coupling capacitance in the input coil, and compared the results.