• Title/Summary/Keyword: magnetic core

Search Result 963, Processing Time 0.026 seconds

Electromagnetic Properties of Magnetic Core Materials and Attenuation of Blocking Filter (Blocking filter용 자심 재료의 전자기 특성 및 신호 감쇄율)

  • 오영우;이해연;김현식
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.16 no.6
    • /
    • pp.490-495
    • /
    • 2003
  • The electromagnetic properties and thermal behavior of Mn-Zn ferrite cores for the blocking filter of Power Line Communication(PLC) application were investigated as a function of additives. The highest density and permeability were 4.98 g/$\textrm{cm}^2$ and 8,221, respectively and were obtained to the specimen with composition of MnO 24 mol%, ZnO 25 mol% and Fe$_2$O$_3$ mol%, added MoO$_3$ of 400 ppm, SiO$_2$ of 100 ppm, and CaO of 200 ppm. The uniform grains were organized, and the microstructures were densified due to reduction of pores in the specimen. The permeability was increased up to 13,904 as the temperature of specimen increased to 110$^{\circ}C$. However, it was decreased precipitously under 100 over 110$^{\circ}C$. The exothermic behavior was observed in the frequency range from 1 kHz to 1 MHz, and the maximum temperature of specimen was 102$^{\circ}C$ at 1 MHz. In the consequence, the Mn-Zn ferrite core developed in this research will maintain the stable electromagnetic properties since the temperature of ferrite core rose to 93$^{\circ}C$ in the range of 100 kHz to 450 kHz bandwidth qualified for PLC. The blocking filters were designed for single phase and three phases using the in-line and non-contact core. The best attenuation ratios of -46.46 dB and -73.9 dB were measured in the range of 100 kHz to 450 kHz bandwidth, respectively.

Spin Wave Interference in Magnetic Nanostructures

  • Yang, Hyun-Soo;Kwon, Jae-Hyun;Mukherjee, Sankha Subhra;Jamali, Mahdi;Hayashi, Masamitsu
    • Proceedings of the Korean Magnestics Society Conference
    • /
    • 2011.12a
    • /
    • pp.7-8
    • /
    • 2011
  • Although yttrium iron garnet (YIG) has provided a great vehicle for the study of spin waves in the past, associated difficulties in film deposition and device fabrication using YIG had limited the applicability of spin waves to practical devices. However, microfabrication techniques have made it possible to characterize both the resonant as well as the travelling characteristics of spin waves in permalloy (Py). A variety of methods have been used for measuring spin waves, including Brillouin light scattering (BLS), magneto-optic Kerr effect (MOKE), vector network analyzer ferromagnetic resonance (VNA-FMR), and pulse inductive microwave magnetometry (PIMM). PIMM is one of the most preferred methodologies of measuring travelling spin waves. In this method, an electrical impulse is applied at one of two coplanar waveguides patterned on top of oxide-insulated Py, producing a local disturbance in the magnetization of the Py. The resulting disturbance travels down the Py in the form of waves, and is inductively picked up by the other coplanar waveguide. We investigate the effect of the pulse width of excitation pulses on the generated spin wave packets using both experimental results and micromagnetic simulations. We show that spin wave packets generated from electrical pulses are a superposition of two separate spin wave packets, one generated from the rising edge and the other from the falling edge, which interfere either constructively or destructively with one another, depending upon the magnitude and direction of the field bias conditions. A method of spin wave amplitude modulation is also presented by the linear superposition of spin waves. We use interfering spin waves resulting from two closely spaced voltage impulses for the modulation of the magnitude of the resultant spin wave packets.

  • PDF

Design and Fabrication of Digital 3-axis Magnetometer for Magnetic Signal from Warship (함정 자기신호 측정용 3-축 디지털 자기센서 설계 및 제작에 관한 연구)

  • Kim, Eunae;Son, Derac
    • Journal of the Korean Magnetics Society
    • /
    • v.24 no.4
    • /
    • pp.123-127
    • /
    • 2014
  • We developed a digital 3-axis flux-gate magnetometer for magnetic field signal measurement from warship during demagnetizing and degaussing processes. For the magnetometer design, we considered following points; the distance between magnetic field measurement station and magnetometer located under sea is about several 100 m, the magnetometer is exposed to magnetic field of ${\pm}1mT$ during demagnetizing process, and magnetometer is located under the sea about 30 m depth. To overcome long distance problem, magnetometer could be operated on wide input supply voltage range of 16~36 V using DC/DC converter, and for the data communication between the magnetometer and measurement station a RS422 serial interface was employed. To improve perming effect due to the ${\pm}1mT$ during demagnetizing process, magnetometer could be compensated external magnetic field up to ${\pm}1mT$ but magnetic field measuring rang is only ${\pm}100{\mu}T$. The perming effect was about ${\pm}2nT$ under ${\pm}1mT$ external magnetic field. The magnetometer was tested water vessel with air pressure up to 6 bar for the sea water pressure problems. Linearity of the magnetometer was better than 0.01 % in the measuring range of ${\pm}0.1mT$ and noise level was $30pT/\sqrt{Hz}$ at 1 Hz.

Implementation of Levitation Controller for Toroidally-Wound Self-Bearing BLDC Motor Using Continuously Invertible Force Model (연속적 역변환이 가능한 힘 모델을 이용한 환형권선 셀프베어링 BLDC 모터의 부상 제어기 구현)

  • Choi, Won-Yeong;Choi, Jung-Kyu;Noh, Myounggyu
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.37 no.7
    • /
    • pp.899-903
    • /
    • 2013
  • A self-bearing is an electric machine that achieves both rotational actuation and magnetic levitation using a single magnetic structure. To be able to stably levitate the rotor in a self-bearing, one needs to have an inverse of the force-current model. However, the force-current model in a self-bearing motor is typically not square. Furthermore, the elements of the matrix vary with respect to the rotational angle, resulting in singularities of the pseudo-inverse at various angles. In this paper, we propose a new force-current model that eliminates the singularities by adding a constraint in coil currents. This constraint eliminates the flux density in the stator core so that the saturation problem in the previous study is avoided. By implementing this force-current model, we are able to implement a levitation controller for a toroidally-wound self-bearing BLDC motor. The model inversion and levitation are validated experimentally.

Preparation and characterization of magnetic nanoparticles with two kinds of core/shell structures (핵/껍질 구조를 가진 두 종류의 자기 나노입자의 제조와 특성비교)

  • 고영재;손인호;김영국;동성용;이근진;박규섭
    • Journal of the Korean Vacuum Society
    • /
    • v.10 no.1
    • /
    • pp.87-92
    • /
    • 2001
  • Magnetic Fe-Co(C) nanocapsules and Fe-Co nanoparticles were prepared by arc-discharge in two kinds of atmospheres, i.e. methane and a mixture of ($H_2$+Ar), respectively. Characterization and magnetic properties of this two kinds of ultrafine particles were investigated systematically by means of X-ray diffraction, Mssbauer spectroscopy, X-ray photoelectron spectroscopy, transmission electron microscopy, energy disperse spectroscopy analysis, chemical analysis, oxygen determination and magnetization measurement. Effects of carbon element, decomposed from a methane atmosphere in carbon arc process, on phase structures, magnetic states and surface characterization were studied in comparison to that of Ar element. Two ultrafine particles showed a little difference in the weight ratio of (Fe/co) and the size for Fe-Co nanoparticles was about two times bigger than Fe-Co(C) nanocapsules. The saturation magnetization of Fe-Co (C) nanocapsules was about 8% higher than that of Fe-Co nanoparticles while their phase constitutions were similar. Although no carbon could be detected by XRD measurement because of extremely thin shells on the surfaces of the cores, it is still believed that they are carbon and oxygen layers.

  • PDF

An Experimental Study on the Design Parameters of the Dashpot type MR fluid mount (대시포트형 MR유체 마운트의 설계 인자에 대한 실험적 고찰)

  • Park, Woo-Cheul;Kim, Il-Gyoum;Lee, Hyun-Chang
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.10 no.12
    • /
    • pp.3567-3573
    • /
    • 2009
  • This research proposed a dashpot type mount design using MR fluids, and investigated experimentally the influence of the design parameters of the dashpot MR fluid mount, which affect the damping forces of the dashpot MR fluid mount. In order to observe the influence, the dashpot MR fluid mount which have the different effective length and the core structure is manufactured. The variations of the resistance forces according to different effective lengths of the magnetic pole of MR fluid mount, along which magnetic field is defined, was investigated. It was founded that the resistance forces from the MR mount decreased with increased input frequencies, while increased with increased applied electric current intensities. Nevertheless, there is no appreciable change in the resistance forces with respect to the effective length variations of the magnetic pole of MR fluid mount.

Development of an Ultra-Violet Lamp and a Ballast for Ship's Ballast Water Treatment (선박평형수 처리용 자외선 램프 및 안정기 개발)

  • Cheon, Sang-Gyu;Park, Dae-Won;Kil, Gyung-Suk
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.35 no.5
    • /
    • pp.675-681
    • /
    • 2011
  • In this paper, we dealt with the design and fabrication of a medium pressure ultra-violet (UV) lamp and a magnetic ballast which are main components for ballast water treatment systems (BWTS). To acquire an optimal discharge condition of UV lamp, electrical and optical characteristics depending on the argon gas volume and the amount of mercury were experimentally analyzed. Rated voltage, current and power consumption of a prototype lamp were 490 [V], 8.6 [A] and 4.0 [kW], respectively. UV intensity of the lamp was 15 [%] higher than that of an equivalent lamp which is used in a BWTS. The magnetic ballast was designed in a UI core type through theoretical analysis and simulation. The open voltage and the rated power consumption of the ballast were 920 [V] and 8.5 [kVA] respectively. The disinfection efficacy which is carried out in a BWTS equipped with the UV lamp and magnetic ballast was over 99.99 [%], and this satisfy the IMO regulations.

A Study on Metal Surface Thickness Detection Using Indsctive Proximity Sensor (유도성 근접센서를 통한 금속표면 두께 검출에 관한 연구)

  • Park, Hwa-Beom;Lee, Seung-Jae;Kim, Young-Kil
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2007.10a
    • /
    • pp.231-234
    • /
    • 2007
  • The magnetic sensor using electromagnetic principle. which transfers magnatic into electric. is the electric component.It has been widely applied to the industry, university and the reseach. However there are some problems. Not only the korean domestic sensor manufacture skills are still lower then the advanced manufacture's but also production of sensor is not well organized yet. Due to cahnging excitation cvurrent, excitation freq and the rate magnetic permeability core, there sometimes would be distorted phenomena or loaded phenomena which result in limited measurment range. Therefore, the signal conversion device should support to receive undistorted and nice output. This paper focuses on both the design of signal transform circuit using inductive proximity sensor and the signal transfer equipment (Z device) which detects thickness of painted material.

  • PDF

A Study on the Removal Method of Radioactive Corrosion Product using its Magnetic Property (방사성 부식생성물의 자기적 성질을 이용한 제거방법에 대한 연구)

  • 송민철;공태영;이건재
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.1 no.1
    • /
    • pp.73-79
    • /
    • 2003
  • In a pressurized water reactor, radioactive corrosion products (CRUD) in primary coolant system are one of the major sources for the occupational radiation exposure of the personnel in a nuclear power plant. Through the recent trend of long term fuel cycle in a nuclear power Plant, radioactive corrosion products deposited in reactor core for a long time are also the cause of Axial Offset Anomaly (AOA) having m effect on reactor power by the hideout of boron. CRUD consist primarily of magnetite, nickel ferrite, cobalt ferrite, and so on. They have the characteristic of strong magnetism. Therefore it is performed the conceptual design to develop the filter which removes the CRUD by magnetic field that is generated by an arrangement of permanent and electric magnets. Contrary to the conventional filter, the proposed filter does not interrupt the fluid flow, so there is little pressure drop and it can be used continuously. It is expected to be applied as one of the technologies for removal of the CRUB.

  • PDF

Synthesis of TiO2-Fe2O3 Nanocomposite Powders for Magnetic Photocatalyst (자성광촉매용 TiO2-Fe2O3 나노복합분말의 합성)

  • Lee Chang-Woo;Kim Soon-Gil;Yun Sung-Hee;Lee Jai-Sung;Choa Yong-Ho
    • Korean Journal of Materials Research
    • /
    • v.15 no.8
    • /
    • pp.508-513
    • /
    • 2005
  • [ $TiO_2-Fe_2O_3$ ] nanocomposite powders for magnetic photocatalyst were synthesized by sol-gel process, in which $TiO_2$ photocatalytic layer was formed on the surface of $\gamma-Fe_2O_3$ magnetic core. Transmission electron microscopy (TEM) observation and X-ray diffractometry (XRD) analysis revealed that$\gamma-Fe_2O_3$ nanoparticles, $10\~20nm$ in diameter, were coated by $TiO_2$ shell of 5nm in thickness and $TiO_2$ was anatase phase. Also hydroxyl group (-OH) used to decompose organic compounds was detected by Fourier transformation infrared spectrometry(FT-IR) analysis. UV-Visible spectrophotometry results showed that light absorption occurred in the wavelength range of $400\~700 nm$, and the band gap energy $(E_g)$ of powder was 1.8 eV. Finally it was found that the coercivity $(H({ci})$ and saturation magnetization $(M_s)$ of the powder were 79 Oe and 14.8 emu/g, respectively as experimental vibrating sample magnetometer (VSM) measurements.