• 제목/요약/키워드: magnetic core

검색결과 963건 처리시간 0.037초

고속으로 회전하는 표면부착형 영구자석 동기발전기의 마그넷 이탈방지 시스템 설계 (Design of Preventing Deviation System of Magnet for high Speed Rotated Surface Mounted Permanent Magnet Synchronous Generator)

  • 김영민;김정수;박선호;임민수;방조혁;류지윤
    • 풍력에너지저널
    • /
    • 제5권1호
    • /
    • pp.50-55
    • /
    • 2014
  • Surface Permanent-Magnetic-Synchronous-Generator (SPMSG) discussed in the present study has operational characteristics such as high rotational speed over 1,000 rpm and centrifugal force of 12 kN·m for each magnet. Structure-development analysis for the minimization of rotor-core weights and the maximization of thermal emission is performed by applying the aluminum-laminated cap which combines the advantages of IPM and SPM in order to overcome the difficulty that attaching the magnet to rotor-core only with an adhesive. In this study, the simulations in terms of structure and electromagnetic were performed with the variable parameters such as shape and thickness of laminated-cap and division method of magnet. As a result, condition for minimized centrifugal force with minimum loss is derived.

홀소자와 자기코어를 이용한 하이브리드 및 전기자동차용 전류센서 제작 (Construction of Current Sensor Using Hall Sensor and Magnetic Core for the Electric and Hybrid Vehicle)

  • 연교흠;김시동;손대락
    • 한국자기학회지
    • /
    • 제23권2호
    • /
    • pp.49-53
    • /
    • 2013
  • 전류센서는 하이브리드 및 전기자동차의 배터리 충 방전과 모터컨트롤러의 모니터링 시스템에 적용되는 중요한 부품이다. 본 연구에서는 자기코어의 공극에 홀센서를 위치시켜 측정전류에 의해 생성된 자기장을 감지하는 구조를 가진 open loop type의 전류센서를 개발하였다. 코어는 방향성규소강판을 사용하여 제작한 후 공극이 3 mm되게 절단하였다. 공극에서의 자기장 측정을 위하여 GaAs 홀센서를 적용하였다. 개발한 전류센서는 측정범위가 -400~+400 A에서 선형도 0.03 %를 확보하였으며, 온도보상회로를 적용하여 동작온도영역인 $-40{\sim}+105^{\circ}C$에서 전류센서의 온도특성을 향상시켰다. 전류센서의 동특성 향상을 위하여 공기자속를 제어하였다. 주파수대역폭 측정은 $40A{\cdot}turn$, 100 Hz~100 kHz의 사인파형으로 측정하여 100 kHz의 대역폭을 갖는 것으로 평가되었으며, 반응속도는 $40A{\cdot}turn$의 5 kHz 구형파로 측정하여 $2{\mu}s$ 이하의 성능을 갖는 것으로 측정되었다.

역동적 유방 자기공명 영상 및 확산 강조영상을 이용한 관상피내암종 저평가 수술전 예측 (Preoperative Prediction of Ductal Carcinoma in situ Underestimation of the Breast using Dynamic Contrast Enhanced and Diffusion-weighted Imaging)

  • 박미나;김은경;김민정;문희정
    • Investigative Magnetic Resonance Imaging
    • /
    • 제17권2호
    • /
    • pp.101-109
    • /
    • 2013
  • 목적: 초음파 유도 하 중심부 침생검으로 진단된 2 cm 이상의 관상피내암종 저평가 수술 전 예측에 역동적 유방 자기공명 영상 및 확산강조영상의 역할을 규명하고자 한다. 대상과 방법: 14 gauge침을 이용한 초음파 유도 하 중심부 침생검을 통해 관상피내암종으로 진단된 22명의 환자를 대상으로 하였다. 환자는 조직병리 결과에 의거하여 관상피내암종 저평가 유무에 따라 두 군으로 나뉘었다. 모든 환자에서 역동적 유방 자기공명 영상 및 확산강조영상을 포함한 3 테슬라 유방 자기공명 영상을 획득하였다. 생검으로 확인된 악성 종괴에 대해, 병변의 형태 (종괴 혹은 비종괴), 조영 증강 형태, 조영 증강 최고점, 및 현성 확산 계수를 CADstream 소프트웨어를 이용하여 획득 하였으며, Fisher's exact test및 Mann Whitney test 이용하여 이 항목을 비교, 분석하였다. 결과: 총 22명의 환자 중 8명의 환자가 저평가 군으로 분류되었다. 병변의 형태 및 조영증강 형태는 두 군의 통계학적 차이가 없었다 (P values = 1.000 및 0.613). 조영 증강 최고점의 중앙값은 저평가 군에서 159.5% 로 저평가 되지 않은 군의 133.5% 보다 높았으나 통계학적 유의한 차이를 보이지 않았다 (P value = 0.413). 저평가 군의 현성 확산 계수는 $1.26{\times}10^{-3}mm^2/sec$로 저평가 되지 않은 군의 $1.35{\times}10^{-3}mm^2/sec$ 보다 낮았다 (P value = 0.094). 결론: 현성 확산 계수는 초음파 유도한 중심부 침생검에 의한 관상피내암종 저평가 수술 전 예측에 도움이 될 가능성 있으며 추후 전향적 연구를 통해 이 연구 결과를 확인하는 것이 필요하겠다.

Core Material Design of a High Performance Rotating Machine Considering Magnetic Anisotropy

  • Ikariga Atsushi;Enokizono Masato;Shimoji Hiroyasu;Yamashiro Hirofumi
    • KIEE International Transaction on Electrical Machinery and Energy Conversion Systems
    • /
    • 제5B권3호
    • /
    • pp.248-252
    • /
    • 2005
  • This paper deals with a new design method for a small-size rotating machine with high power. In order to achieve high performance, secondary excitation by Nd-Fe-B magnets and the grain oriented electrical steel sheets were selected and a new design using dual rotors is proposed. The outline of the high-performance rotating machine will be presented and the results of the finite element analysis by using this method combined with the E&SS modeling will be shown in the paper.

AC 솔레노이드 밸브의 설계 및 특성 (Design and Characteristic of the AC Solenoid Valve)

  • 김동수;전용식
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2007년도 춘계학술대회B
    • /
    • pp.3056-3061
    • /
    • 2007
  • The technology of AC solenoid valves is now considered as a core technology in the fields of the production line of semi-conductor chips and the micro fluid chips for medical applications. And AC solenoid valves, which operate by compressed air, are characterized by high speed response, great repeatability and that the pressure on the cross sectional area of poppet is kept constant regardless of the fluctuation of the pressure exerted on the ports. In this study, AC solenoid valves that posses the high-speed responsibility and the high rate of flow have designed and analyzed through the law of equivalent magnetic circuit and Finite Element Method (FEM) respectively. In case of poppet, Flow field characteristic was analyzed by the variation of poppet and it was able to display flow field by changing the location of the poppet. Also, we verified possibility of the design through the static and dynamic pressure and the 3D distribution curve of the force by working the front poppet.

  • PDF

고응력장의 해석을 위한 대자율 비등방성 연구 (Interpretation of Palaeostress Using Anisotrophy of Magnetic Susceptibility)

  • 김성욱;김인수;이동호;윤운상;정의진;양홍영;전영길
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2003년도 봄 학술발표회 논문집
    • /
    • pp.369-374
    • /
    • 2003
  • A study of anisotropy of magnetic susceptibility (AMS) have been carried out to understand the tectonic stress field of late Cretaceous-Tertiary strata in Yangsan area. A total of 119 independently oriented core samples were collected from 9 sites throughout the area. The study results show that 5 sites are characterized by load foliation, and 4 sites by tectonic foliation. Load foliations caused by the weight of the overlying strata occur in the central part of the study area. Tectonic foliations created by compressional tectonic force show a regional variation in direction: Direction of compression axes derived from tectonic foliation in the southern part of the study area is approximately WNW-ESE, while it changes into NE-SW northern part of the study area. Such compressional directions are compatible with the lineament directions in each area.

  • PDF

유한요소법을 이용한 유도형 고온 초전도 한류기용 DC Reactor의 설계 파라미터 결정법에 관한 연구 (The Study of Designing the Parameters of DC Reactor for Inductive Superconducting Fault Current Limiter By Using Finite Element Method)

  • 김용구;강형구;김태중;윤용수;고태국
    • 한국초전도저온공학회:학술대회논문집
    • /
    • 한국초전도저온공학회 2002년도 학술대회 논문집
    • /
    • pp.326-329
    • /
    • 2002
  • The dc reactor type superconducting fault current limiter is composed of a power converter, magnetic core reactors and a do reactor that is a superconducting coil. When a fault occurs, the dc reactor maintains the stability of system by limiting its fault current. In this study, we focus on the design of the dc reactor using FEM(Finite Element Method). In order to design it, various elements should be considered such as magnetic field intensity, Lorentz's force, its inductance and so forth. Firstly, we forecast the values of those elements from the simulation of FEM and then measured with a copper wire magnet. Finally, verify the reliability of this FEM method by comparing with two results.

  • PDF

푸시 풀 포워드 컨버터의 주파수 변화, 변압기의 권선비와 1차측 권선 변화에 대한 효율 특성 (Push Pull Forward Converter Efficiency Quility)

  • 전준석;김창선;김태식;임범선;우승훈
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2003년도 춘계전력전자학술대회 논문집(1)
    • /
    • pp.36-39
    • /
    • 2003
  • The push pull forward converter is a very suitable circuit for low output voltage, high output current applications with a wide input voltage range. All the magnetic components (output inductor, transformer, input filter) can be integrated into a single core. The integrated magnetics can reduce the number of the magnetic components. Developed the push pull forward converter rating are of 36 $\~$72V input and 3.3V/30A output. In this converter, the efficiency was measured by $76.4\%$ at full load and 82.95$\%$ at full load. The maximum efficiency is up to 83.$\%$ at 200kHz switching frequency, l1A output.

  • PDF

초절전형 마이크로 밸브 특성해석 및 실험 (Characteristic Analysis and experiment of the Low Power Consumption type Micro Valve)

  • 김동수;박상운;김현섭;류재섭;이원희
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2004년도 추계학술대회
    • /
    • pp.876-881
    • /
    • 2004
  • In this study, A special quality analysis and experiment for low power consumption type pneumatic on-off micro valve was performed. And flow characteristics of the micro valve by stroke change was numerically investigated. As a result, it is shown that magnetic force(2.4N) is exerted enough to move poppet with 0.3mm stroke with 0.01 seconds of response time, and that there is no magnetic force emitted by yoke. Under the condition of poppet stroke smaller than about 0.8mm, dynamic pressure acts to poppet wall up to supply pressure level. But, that is decreasing to 40% when poppet stroke is 0.8mm.

  • PDF