• 제목/요약/키워드: magnetic attachment

검색결과 77건 처리시간 0.028초

The influence of the number and the type of magnetic attachment on the retention of mandibular mini implant overdenture

  • Lee, Eunjee;Shin, Soo-Yeon
    • The Journal of Advanced Prosthodontics
    • /
    • 제9권1호
    • /
    • pp.14-21
    • /
    • 2017
  • PURPOSE. The aim of this study was to compare the retention of mini implant overdenture by the number, the type of magnetic attachment, and the directions of applied dislodging force. MATERIALS AND METHODS. The experimental groups were designed by the number and type of magnetic attachment. Twenty samples were tested with Magden implants. Each attachment was composed of the magnet assembly in overdenture sample and the abutment keeper in a mandibular model. Dislodging forces were applied to the overdenture samples (50.0 mm/min) in 3 directions. The loading was repeated 10 times in each direction. The values of dislodging force were analyzed statistically using SPSS at 95% level of confidence. RESULTS. The retentive force of group 2 was greater than that of group 1 in both types of attachment in every direction (P < .05). Oblique retentive force of flat type magnetic attachment was higher than that of cushion type attachment in both groups (P < .05). In group 1, oblique retentive force showed the highest and anterior-posterior retentive force showed the lowest value in both attachment types (P < .05). In group 2, both types of attachment showed the lowest retentive force with anterior-posterior direction of dislodging force (P <.05). CONCLUSION. Proper retentive properties for implant overdenture were obtained, regardless of the number and type of magnetic attachment. In both types of magnetic attachment, the greater retentive force was attained with more implants. Oblique retentive force of flat type magnetic attachment was greater than that of cushion type. Among all subgroups, anterior-posterior retentive force was the lowest among three different directions of dislodging force.

A study on the changes in attractive force of magnetic attachments for overdenture

  • Leem, Han-Wool;Cho, In-Ho;Lee, Jong-Hyuk;Choi, Yu-Sung
    • The Journal of Advanced Prosthodontics
    • /
    • 제8권1호
    • /
    • pp.9-15
    • /
    • 2016
  • PURPOSE. Although magnetic attachment is used frequently for overdenture, it is reported that attractive force can be decreased by abrasion and corrosion. The purpose of this study was to establish the clinical basis about considerations and long term prognosis of overdenture using magnetic attachments by investigating the change in attractive force of magnetic attachment applied to the patients. MATERIALS AND METHODS. Among the patients treated with overdenture using magnetic attachments in Dankook University Dental Hospital, attractive force records of 61 magnetic attachments of 20 subjects who re-visited from July 2013 to June 2014 were analyzed. Dental magnet tester (Aichi Micro Intelligent Co., Aichi, Japan) was used for measurement. The magnetic attachments used in this study were Magfit IP-B Flat, Magfit DX400, Magfit DX600 and Magfit DX800 (Aichi Steel Co., Aichi, Japan) filled with Neodymium (NdFeB), a rare-earth magnet. RESULTS. Reduction ratio of attractive force had no significant correlation with conditional variables to which attachments were applied, and was higher when the maintenance period was longer (P<.05, r=.361). Reduction ratio of attractive force was significantly higher in the subject group in which attachments were used over 9 years than within 9 years (P<.05). Furthermore, 16.39% of total magnetic attachments showed detachment of keeper or assembly. CONCLUSION. Attractive force of magnetic attachment is maintained regardless of conditional variables and reduction ratio increased as the maintenance period became longer. Further study on adhesive material, attachment method and design improvement to prevent detachment of magnetic attachment is needed.

치과용 자석부착장치의 물리적, 생물학적 특성에 관한 연구 (A STUDY ON THE PHYSICAL PROPERTIES AND BIOLOGICAL CHARACTERISTICS OF DENTAL MAGNETIC ATTACHMENTS)

  • 임용식;김영수;김창회;김용호
    • 대한치과보철학회지
    • /
    • 제37권1호
    • /
    • pp.1-22
    • /
    • 1999
  • In order to investigate various physical and biological properties of dental magnetic attachments studies on retentive characteristics, corrosion properties, cytotoxicity of different magnetic systems for dental applications were done. For the study of retentive characteristics changes of retentive force by increasing air gap, wear properties of various attachment systems and loss of magnetic force by heat treatment were measured. Forte study of corrosion property of magnet covering metal electrochemical corrosion was done in artificial saliva and 0.9% NaCl solution between $-1,000mV_{SCE}\;and\;+1,000mV_{SCE}$. Anodic polarization curves are obtained about 6 types of samples and 2 types of solution. Corroded surfaces were examined with metallurgical microscope, scanning electron microscope and surface profilometer. For the study of cytotoxicity of magnetic attachment and its field cell growth and agar overlay test were done. The results of this study were as follows. 1. In Magnetic attachments using closed circuit retentive force at zero air gap was greater than magnets using open circuit, but decrease of retentive force by increasing air gap was also greater than open systems. 2. After 40,000 cycles of wear test all mechanical attachment resulted in varing degree of retention loss but in magnetic attachments no loss of retentive force was observed. 3. The magnetic attachment using Neodymium magnet showed early loss of retentive force about $200^{\circ}C$ but attachment using Samarium magnet showed some resistance to heat treatment and complete retention loss was observed about $500^{\circ}C$. The keeper was not influenced by heat treatment in retention. 4. In electrochemical corrosion test Dyna magnetic attachment covering metal showed the highiest corrosion resistance and Shiner magnet covering metal showed the least corrosion resistance and examination of corroded surface with metallurgical microscope, scanning electron micro-scope and surface profilometer also showed same results with anodic polarization corves. 5. The result of cell culture tests on the magnet covered with metal showed least recognizable cytotoxicity.

  • PDF

측두하악관절 내장 환자의 관절원판과 관절원판 후조직의 자기공명영상 신호강도 (Magnetic resonance imaging signal intensity of temporomandibular joint disk and posterior attachment in patients with internal derangement)

  • 정연화;조봉혜
    • Imaging Science in Dentistry
    • /
    • 제31권2호
    • /
    • pp.93-99
    • /
    • 2001
  • Purpose: To analyze the possible association between magnetic resonance imaging signal intensity of temporomandibular joint disk and posterior attachment, and the type and extent of disk displacement, disk configuration, effusion and clinical signs in patients with internal derangement. Materials and Methods: Magnetic resonance images of the 132 temporomandibular joints of 66 patients with temporomandibular joint displacement were analyzed. The clinical findings were obtained by retrospective review of the patients' records. The type and extent of disk displacement, disk configuration and effusion were evaluated on the proton density MR images. The signal intensity from the anterior band, posterior band and posterior attachment were measured on MR images. The associations between the type and extent of disk displacement, disk configuration, effusion and clinical signs and the MR signal intensity of disk and posterior attachment were statistically analyzed by student's t-test. Results: Of 132 joints, 87 (65.9%) showed anterior disk displacement with reduction (ADR) and 45 (34.1%) showed anterior disk displacement without reduction (ADnR). The signals from posterior attachments were lower in joints with ADnR than those of ADR (p<0.05). The results showed statistically significant (p<0.05) association between the type and extent of disk displacement and disk configuration, and decreased signal intensity of posterior attachment. There were no statistical associations between pain, noise and limited mouth opening, and signal intensity of disk and posterior attachment. Conclusions: The average signal from posterior attachment was lower in joints with ADnR than that of ADR. The type and extent of disk displacement and disk configuration appeared to be correlated with the signal intensity from posterior attachment.

  • PDF

구강 환경에서 사용된 자성 Dyna 어태치먼트의 부식현상 (CORROSION PHENOMENA OF MAGNETIC ATTACHMENT USED IN ORAL ENVIRONMENT)

  • 곽종하;정재헌;최한철
    • 대한치과보철학회지
    • /
    • 제40권5호
    • /
    • pp.470-483
    • /
    • 2002
  • The purpose of this study was to investigate further the mechanics of failure of magnets used for denture retention. Dyna magnets were retrived from denture that had failed after 34 months of clinical use. The magnets were observed and sectioned in order to analyse with high resolution scanning electron microscope. From this study, corrosion behaviors of used magnetic attachment were analysed. The results were as follows ; 1. In Nd-Fe-B based magnetic materials, the erosion-corrosion was started at ununiformed part of stainless steel cover. 2. Corrosion was initiated at weared stainless steel surface and then magnetic materials were spalled by corrosive solution. 3. Spatting was occurred in Nd-Fe-B magnet materials due to corrosion products and then corrosion rate was increased drastically. 4. Corrosion started from ununiformed stainless steel surface as well as welded zone. In conclusion, the failure of magnets may occur by either breakdown of the welding or breakdown of the encapsulating material. So, it is considered that the corrosion problem of dental magnetic materials could be solved to some extent with surface treatment of dental magnetic materials.

영구 자석 바퀴를 이용한 벽면 이동 로봇의 설계시의 설계지침 (Guideline for the Design of Wall-Climbing Mobile Robot Using Permanent Magnetic Wheels)

  • 이화조;김은찬;한승철
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 2002년도 추계학술대회 논문집
    • /
    • pp.548-553
    • /
    • 2002
  • Most tasks of the large vertical or ceiling structures have been carried out by human power. Those tasks require us much operation costs and times, safety devices, etc. So the need of automation for those tasks have been rising. That automation needs a wall-climbing mobile vehicle. Most former researches are things about attachment devices and moving mechanisms. A wall-climbing mobile vehicle must be designed by a method different from the case of the vehicle of the horizontal environment. That is because gravity acts as a negative role on the stability of a wall-climbing vehicle. In this thesis, the particular shape characteristics of a wall-climbing mobile vehicle are derived by the wall-environment modeling. In addition, some design constraints of the permanent magnetic wheel as an attachment device was studied. According to those requirements and constraints, one specific wall-climbing mobile vehicle was designed and some experiments were made on the attachment ability of that vehicle.

  • PDF

하악에서 완압형 자성 어태치먼트를 부착한 임플란트-자연치 피개 의치: 10년 증례보고 (Mandibular implant-natural tooth retained overdenture using magnetic attachment with stress breaker)

  • 박은철;이수연;김희중
    • 구강회복응용과학지
    • /
    • 제31권4호
    • /
    • pp.378-386
    • /
    • 2015
  • 피개 의치는 의치의 안정과 유지력 증가라는 장점을 갖지만 지대치가 우식 또는 치주질환에 이환되기 쉬우며 의치의 두께가 얇아짐으로써 의치가 파절되기 쉽다는 단점도 갖고 있다. 자성 어태치먼트 피개 의치는 수직적 유지력은 크지만 수평적 유지력은 작으므로 지대치나 임플란트에 덜 위해한 힘을 가하며, 다른 기계적 유지장치에 비해 마모나 파손 등이 적다는 장점이 있다. 피개 의치에서 나타나는 의치의 파절은 의치상의 두께가 얇아져서 발생하기도 하지만, 연조직과 경조직, 임플란트와 자연치의 압하량 차이로 인해 발생하기도 한다. 이를 보상하기 위해 silicone ball이 자석 안에 삽입되어있는 자성 어태치먼트가 개발되었으며, 이를 이용해 피개 의치를 제작한 증례에서 우수한 결과가 나타나 보고하고자 한다.

자석 유지장치를 이용한 Overdenture 수복에 관한 임상적 연구 (CASE REPORTS ON THE MAGNETIC RETAINED OVERDENTURES)

  • 방몽숙;최창환;김영이
    • 대한치과보철학회지
    • /
    • 제40권1호
    • /
    • pp.88-97
    • /
    • 2002
  • The purpose of this study was to evaluate a cases which was treated with magnetic attachments on the patients in edentulous mandible and maxilla. Author made magnetic overdenture for two patients and then clinical examination were used for evaluation of the function and change in retention during 30months. Patients showed difficulty in oral hygiene care at the beginning but they go used to it soon. It was effective in promotion of denture retention and stability and also gave patient emotionally uplifting psychologic state. This study suggest that magnetic attachment was effective for the treatment of patients presenting a few remaining teeth or teeth under severe caries or mobility.

외배엽 이형성증 어린이에서 magnetic attachment를 이용한 보철치료 (USE OF MAGNETS IN THE TREATMENT OF ECTODERMAL DYSPLASIA)

  • 주진형;이광희;김대업;이종선
    • 대한소아치과학회지
    • /
    • 제28권4호
    • /
    • pp.626-632
    • /
    • 2001
  • 외배엽 이형성증은 무한증, 감모증, 무치증 등의 한가지 이상의 외배엽기관의 선천적 이상소견이 특징인 유전성 질환이다. 이런 증상을 가진 어린이들은 치조골 발육의 부족으로 수직고경이 감소하여 노인과 같은 안모를 가지게 되며 저작, 발음, 심미적 장애와 그로 인한 정서적 문제가 있다. 이런 어린이에게 보철적 치료를 통해 수직고경을 회복하고 기능과 심미를 개선하는 것은 중요한 의의를 가진다고 할 수 있다. Magnetic attachment는 자성의 힘을 이용하여 가철성 의치를 지대치로 연결해 유지와 안정을 얻어내는 장치로 유지안정은 물론 심미적으로도 우수하다. 본 증례에서는 원광의료원 치과병원 소아치과에 내원한, 부분적 무치증을 동반한 외배엽 이형성증 어린이에서 magnetic attachment를 이용한 보철치료를 시행하여 양호한 결과를 얻었기에 보고하는 바이다.

  • PDF