Assessment of Internal Dose by $^3H\;&\;^{14}C$ of Total Diet for Inhabitants near Wolsung Nuclear Power Plants

  • Park, G.;Lin, X.J.;Kim, W.;Kang, H.D.;Doh, S.H.;Kim, D.S.;Kim, C.K.
    • Journal of Radiation Protection and Research
    • /
    • 제28권1호
    • /
    • pp.51-57
    • /
    • 2003
  • To assess the internal dose by $^3H\;&\;^{14}C$ in total diet of inhabitants near Wolsung Nuclear Power Plants, TFWT, OBT and $^{14}C$ concentration in total diet was analyzed for collection region and time. TFWT, OBT and $^{14}C$ concentrations were in the range of 3.19-42.2 Bq/L, 1.00-39.4 Bq/L, and 0.230-0.855 Bq/gC, respectively. The calculated annual effective dose with TFWT, OBT and $^{14}C$ is $6.10{\times}10^{-5}mSv/y,\;3.71{\times}10^{-5}mSv/y\;and\;7.08{\times}10^{-3}mSv/y$, respectively. And then annual internal dose with total diet for inhabitants near Wolsung NPPs is about $7.18{\times}10^{-3}mSv/y$, which is about 0.72% of annual effective dose limit 1 mSv/y.

전신 PET/CT 영상 획득 프로토콜을 이용한 유효선량 평가 (Effective Dose Evaluation using Clinical PET/CT Acquisition Protocols)

  • 남소라;손혜경;이상훈;이창래;조효민;김희중
    • 한국의학물리학회지:의학물리
    • /
    • 제17권3호
    • /
    • pp.173-178
    • /
    • 2006
  • 본 연구는 임상 환경에서의 전신 PET/CT 영상 획득방식 조건에서 환자가 받는 피폭선량을 Alderson 팬텀과 TLD를 이용하여 측정하는 것이었다. Philips GEMINI PET/CT에서는 $^{137}Cs$ 투과 스캔과 이와의 비교를 위한 고화질 CT 투과 스캔 및 토포그램을 각각 수행하여 각 인체 장기별 선량을 측정하였다. GE DSTe PET/CT에서는 감쇄 보정용 CT투과 스캔과 진단용 전신 CT스캔 및 토포그램 그램을 각각 수행하여 인체 내 장기별 선량을 측정하였다. 여기서 각 인체 장기는 ICRP 60에서 추천하는 장기를 참고로 선택하였다. 또한 실험에 사용한 TLD는 10 MV X선을 사용하여 교정한 후 5% 이내의 정확도를 가지는 것만 사용하였다. 그 결과 Philips GEMINI PET/CT에서의 $^{137}Cs$ 선원을 이용한 투과 스캔의 유효선량은 $0.14{\pm}0.950mSv$, 고화질 CT투과 스캔에서의 유효선량은 $29.49{\pm}1.508mSv$, 토포그램에서의 유효선량은 $0.72{\pm}0.032mSv$로 나타났다. 또한 GE DSTe PET/CT에서 감쇄보정용 CT투과 스캔의 유효선량은 $20.06{\pm}1.003mSv$, 진단용 전신 CT스캔의 유효선량은 $24.83{\pm}0.805mSv$, 토포그램의 유효선량은 $0.27{\pm}0.008mSv$로 나타났다. 임상 환경에서의 PET/CT 영상을 획득했을 시 종합 피폭은 PET영상을 획득했을 때의 유효선량을 더함으로써 평가할 수 있었다. 그 결과 Philips GEMINI PET/CT (Topogram+$^{137}Cs$ transmission scan + PET, Topogram +high Quality CT+ PET)와 GE DSTe PET/CT (Topogram+CT attenuation map+PET, Topogram+CT for diagnosis+PET)에서 환자가 받는 총 유효선량들은 각각($7.65{\pm}0.951mSv$$37.00{\pm}1.508mSv$), ($27.12{\pm}1.003mSv,\;31.89{\pm}0.805mSv$)로 나타났다. PET/CT 영상 획득 시에 가능한 한 피폭은 적게 하면서도 진단이 가능한 화질을 유지할 수 있는 최적의 프로토콜 마련이 시급한 것으로 생각된다.

  • PDF

엉덩관절 정면 검사 시 환자 피폭 감소 (Reducing Radiation Exposure During X-ray Imaging of Both Hip AP)

  • 신성규;이효영
    • 한국방사선학회논문지
    • /
    • 제10권5호
    • /
    • pp.313-320
    • /
    • 2016
  • 본 연구는 엉덩관절 정면 검사 시 격자 제거와 관전압, Cu Filter의 조합을 이용하여 환자의 피폭을 감소하고자 시행하였다. 엉덩관절 정면 검사법을 대상으로 격자의 사용과 제거 상태에 따라 각각 관전압을 60~90 kV로 변화시키고 Cu Filter를 0.1~0.3 mm로 추가시켜 입사선량, 유효선량을 측정하고 영상의 진단적 가치를 평가하였다. 격자를 사용하고 관전압 60 kV, none filter에서 입사선량은 4.77 mGy로 가장 높은 측정치를 나타냈고 격자를 사용하지 않고 90 kV, 0.3 mm Cu filter 조건에서의 입사선량은 0.14 mGy로 가장 낮았으며 약 34배의 차이를 나타냈다. ICRP Pub. 60을 기준으로 70 kV에서 고환, 난소의 유효선량은 격자를 사용 했을 경우 0.255 mSv, 격자를 제거하였을 경우에는 0.049 mSv로 약 5.2배의 차이를 나타냈다. ICRP Pub. 103을 기준으로 70 kV에서 고환, 난소의 유효선량은 격자를 사용했을 경우 0.090 mSv 격자를 제거하였을 경우에는 0.020 mSv로 약 4.5배의 차이를 나타냈다. 격자를 사용하였을 경우의 노광지수는 671~782, 격자를 제거하였을 경우에는 513~606 사이로 적정 노출조건이었으며 영상평가결과 모두 진단적 가치가 있는 영상으로 나타났다. 따라서 엉덩관절 정면 검사 시 격자를 제거하고 관전압을 높이고 Cu Filter를 추가시켜 촬영하면 환자의 피폭을 줄일 수 있을 것이다.

폐암 고에너지 방사선치료 시 갑상선 피폭에 관한 연구 (A Study on the Thyroid dose high-energy Radiation Therapy of Lung Cancer)

  • 양오남;임청환
    • 한국콘텐츠학회:학술대회논문집
    • /
    • 한국콘텐츠학회 2015년도 춘계 종합학술대회 논문집
    • /
    • pp.167-168
    • /
    • 2015
  • 고에너지 의료용 선형가속기를 이용한 폐암 방사선치료 시 갑상선에 미치는 선량을 평가하였다. 산란광자의 영향은 3DCRT 시 평균 27.9mSv, IMRT에 있어서는 43.6mSv로 평가 되었다. 광중성자의 영향은 3DCRT 시 평균 3.2mSv, IMRT에 있어서는 평균 4.7mSv로 평가 되었다. 산란광자와 광중성자 모두 3DCRT 보다 IMRT가 높은 것으로 평가 되었다. 본 연구를 통하여 고에너지를 이용한 방사선치료 시 인접한 정상조직에 상당한 양의 산란선량이 영향을 주는 것으로 평가된 바와 같이 방사선을 이용한 암 치료 종사자는 이러한 내용을 충분히 인지하여 피폭 저감화를 위한 노력이 필요할 것으로 사료된다.

  • PDF

폐암 고에너지 방사선치료 시 갑상선 피폭에 관한 연구 (A Study on the Thyroid dose high-energy Radiation Therapy of Lung Cancer)

  • 양오남;임청환
    • 한국콘텐츠학회:학술대회논문집
    • /
    • 한국콘텐츠학회 2014년도 추계 종합학술대회 논문집
    • /
    • pp.181-182
    • /
    • 2014
  • 고에너지 의료용 선형가속기를 이용한 폐암 방사선치료 시 갑상선에 미치는 선량을 평가하였다. 산란광자의 영향은 3DCRT 시평균 27.9mSv, IMRT에 있어서는 43.6mSv로 평가 되었다. 광중성자의 영향은 3DCRT 시 평균 3.2mSv, IMRT에 있어서는 평균 4.7mSv로 평가 되었다. 산란광자와 광중성자 모두 3DCRT 보다 IMRT가 높은 것으로 평가 되었다. 본 연구를 통하여 고에너지를 이용한 방사선치료 시 인접한 정상조직에 상당한 양의 산란선량이 영향을 주는 것으로 평가된 바와 같이 방사선을 이용한 암치료 종사자는 이러한 내용을 충분히 인지하여 피폭 저감화를 위한 노력이 필요할 것으로 사료된다.

  • PDF

연구용 원자로 2호기의 로심 집합체 제염$\cdot$해체 경험 (Experience for The Decontamination & Decommissioning of The Core Assembly of KRR-2 Research Reactor)

  • 정경환;정기정;박진호
    • 한국방사성폐기물학회:학술대회논문집
    • /
    • 한국방사성폐기물학회 2003년도 가을 학술논문집
    • /
    • pp.655-659
    • /
    • 2003
  • 1972년 TRIGA Mark - III(KRR-2) 연구용 원자로가 건설 운영되어 왔다. 대전 하나로의 가동으로 1999년 방사성 동위원소 생산을 중단한 후 모든 시설은 안전 저장 형태로 유지되어 왔으나, 해체 프로그램에 따라 2003년 로심 집합체를 제염$\cdot$해체하게 되었다. 로심 집합체와 회전시료 조사대의 표면 방사능 선량은 300mSv/h - 700mSv/h으로 측정되었다. 이 보고서는 로심 집합체의 제염$\cdot$해체, 방사선 안전관리, 그리고 폐기물 관리 등의 과정을 서술하였다.

  • PDF

원자력발전소 주변 표층해역에 출현하는 해양생물의 계절별 음향산란 분포 (Seasonal distribution of marine organisms in the surface layer around nuclear power plants using acoustic)

  • 민은비;강태종;손영태;황두진
    • 수산해양기술연구
    • /
    • 제60권1호
    • /
    • pp.9-17
    • /
    • 2024
  • In this study, the seasonal distribution was surveyed using acoustic in the coastal waters around nuclear power plants. Acoustic surveys were conducted in June, September, December 2022, and March 2023 in the coastal waters of Uljin-gun. According to the results of this study, zooplankton were distributed at the depths from 0 m to 50 m in the waters around nuclear power plants. Zooplankton appeared in summer (June), autumn (September), and spring (March). In the survey area, fish were distributed at the depths from 25 m to 190 m, appearing in the summer (June), autumn (September), winter (December) and spring (March). The SV of zooplankton appearing in the survey area ranged from -98.0 dB to -78.0 dB, and it exhibited a one-class in the frequency distribution of SV. The SV of fish appearing in the survey area ranged from -36.0 dB to -35.0 dB and -98.0 dB to -53.0 dB, and it exhibited two-class in the frequency distribution of SV.

식도암의 방사선치료 성적 (Treatment Results of Esophageal Carcinoma Treated by Radiation Therapy)

  • 김미숙;류성렬;조철구;유헝준;양광모;강진오;지영훈;이동한;류백렬
    • Radiation Oncology Journal
    • /
    • 제18권3호
    • /
    • pp.182-186
    • /
    • 2000
  • 목적 : 수술을 시행하지 않은 식도암 환자에서 방사선치료 후 생존율 및 예후 인자를 파악하여 향후 치료 방침 결정에 도움이 되고자 한다. 대상 및 방법 : 1992년부터 1996년까지 원자력병원 방사선종양학과에서 근치적 또는 고식적 목적으로 치료를 받은 식도암 환자를 대상으로 하여 후향적 분석을 시행 하였다. 수술 또는 방사선치료 후 재발한 환자 및 방사선조사를 40 Gy 미만으로 받은 환자를 제외한 40명의 환자를 대상으로 하였다. 이 중 남자는 35명, 여자는 5명이었다. 2 명의 환자는 생검을 시행하지 않았고 그 외 환자는 모두 편평 상피암이었다. AJCC 1997 병기별 분포는 I 1명, IIA 6명, IIB 6명, III 10명, IVA 12명, IVB 4명 이고 병기를 알 수 혀는 경우가 1명이었다. 보조 항암화학요법을 시행한 환자는 모두 10명이었다. 조사선량의 범위는 $40\~60$ Gy이고 중앙선량은 59.4 Gy 였다. 결과 : 전체 환자의 중앙생존기간은 6.5개월이고 1년 생존율은 $28.3\%$이다. 연령 및 병변위치, 방사선량, 항암화학요법 추가에 관한 생존율의 차이는 관찰되지 않았다. 각각의 병기에 따라 생존율의 차이는 관찰되지 않아 임상병기는 예후에 큰 도움이 되지 않았다. 그러나 병기 III이내의 환자와 병기 tV이상의 환자 사이에는 통계학적으로 의미있지는 않았지만 중앙생존기간이 각각 7.6개월 및 6.2개월로 차이를 보였다. 결론 : 식도암의 생존율은 극히 불량하였다. 환자의 전신 상태 등을 고려하여 완치 및 고식적 목적을 구별하고 항암화학요법의 추가 및 스텐트(Stent), 또는 근접 조사치료를 추가 함으로 생존율의 증가 및 고식적 치료 목적을 달성하여야 할 것이다.본 연구에서는 근치적 수술 등 국소조절의 중요성이 강조되었다.모양이 불규칙한 병변에 대하여도 정위방사선치료를 확대 적용할 수 있겠다.m$1.35 mSv 였으며 법적 선량한도인 50mSv보다 훨씬 적은 량이지만 그 중 125명(36$\%$)은 방사선과 관련 없는 일반인의 방사선 피폭의 선량한도인 1년간 1 mSv 보다 많은 양의 피폭을 받고 있었다 연령에 따른 방사선 피폭은 30세이하에서 평균 1.87$\pm$1.01 mSV, 31세에서 40세 사이가 평균 1.22$\pm$0.69 mSV, 41세 이상에서 평균 0.97$\pm$0.43 mSV로 연령이 적을수록 많은 양의 피폭을 받고 있었다(p<0.01). 병원 내에서 방사선 피폭을 많이 받는 장소가 한정되어 있었다. 방사선을 취급하는 과별로 받는 년간 평균 피폭 선량은 진단방사선과 1.65$\pm$1.54mSv, 치료방사선과 1.17$\pm$0.82 mSv, 핵의학과 1.79$\pm$1.42 mSv, 기타 0.99$\pm$0.51 mSv였으며 상대적으로 저선량율 에너지를 사용하는 핵의학과에서 다른 과와 비교해서 방사선 피폭이 높게 나타났으며(p<0.05), 핵의학과 내에서는 특히 동위원소 조작실과 주입실의 년간 평균 피폭량이 3.69$\pm$1.81 mSv으로 많은 피폭을 받고 있었다(p<0.01). 진단방사선과 내에서는 대장 촬영실 근무자의 연평균 피폭량이 3.74$\pm$1.74 mSv로 가장 많이받고 있으며(p<0.01) 그외 투시진단법(Fluoroscopy) 등 직접 투시를 요하는 촬영실,

  • PDF

Reconstruction of Radiation Dose Received by Diagnostic Radiologic Technologists in Korea

  • Choi, Yeongchull;Kim, Jaeyoung;Lee, Jung Jeung;Jun, Jae Kwan;Lee, Won Jin
    • Journal of Preventive Medicine and Public Health
    • /
    • 제49권5호
    • /
    • pp.288-300
    • /
    • 2016
  • Objectives: Diagnostic medical radiation workers in Korea have been officially monitored for their occupational radiation doses since 1996. The purpose of this study was to design models for reconstructing unknown individual radiation doses to which diagnostic radiation technologists were exposed before 1996. Methods: Radiation dose reconstruction models were developed by using cross-sectional survey data and the personal badge doses of 8167 radiologic technologists. The models included calendar year and age as predictors, and the participants were grouped into six categories according to their sex and facility type. The annual doses between 1971 and 1995 for those who were employed before 1996 were estimated using these models. Results: The calendar year and age were inversely related to the estimated radiation doses in the models of all six groups. The annual median estimated doses decreased from 9.45 mSv in 1971 to 1.26 mSv in 1995, and the associated dose variation also decreased with time. The estimated median badge doses from 1996 (1.22 mSv) to 2011 (0.30 mSv) were similar to the measured doses (1.68 mSv to 0.21 mSv) for the same years. Similar results were observed for all six groups. Conclusions: The reconstruction models developed in this study may be useful for estimating historical occupational radiation doses received by medical radiologic technologists in Korea.

의료용 선형가속기의 Flattening Filter Mode와 Flattening Filter Free Mode 간에 광중성자 선량 평가 (A Study on the Photoneutron Dose Estimation in Flattening Filter Mode and Flattening Filter Free Mode for Medical Linear Accelerator)

  • 양오남;임청환
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제40권2호
    • /
    • pp.297-302
    • /
    • 2017
  • 본 연구에서는 최신형 선형가속기 TrueBeam을 대상으로 10 MV FF mode와 FFF mode간 광중성자의 발생량을 평가하였고, FFF mode에서 10 MV, 15 MV 에너지 변화에 따라 발생되는 광중성자의 발생량을 평가하였다. 발생된 광중성자는 13개 측정점에서 평가하였으며, 발생된 광중성자 수집을 위해서는 한국천문연구원에서 개발한 조직등가비례계수기(KTEPC)를 이용하였다. 10 MV FF mode와 FFF mode 간 측정결과에서 10 MV FF mode가 모든 측정 점에서 높게 측정되었으며, Superior 방향에서 0.455 mSv와 0.152 mSv로 가장 많은 차이를 보였으며, FF에서 33% 이상 많은 광중성자가 발생하였다. FFF mode에서 10 MV, 15 MV 에너지에 따라서는 15 MV에서 모든 방향에서 높게 평가되었고, 방향 기준으로는 Superior 방향에서 0.402 mSv로 가장 높게 평가되었으며, 전체 평균 6.9%로 높게 측정되었다.