• Title/Summary/Keyword: mSv

Search Result 562, Processing Time 0.027 seconds

A Study on the Application of Two-dosimeter Algorithm to Estimate the Effective Dose in an Inhomogeneous Radiation Field at Korean Nuclear Power Plants (원전 불균일 방사선장하에서 유효선량 평가를 위한 복수선량계 알고리즘 적용방안 연구)

  • Kim, Hee-Geun;Kong, Tae-Young
    • Journal of Radiation Protection and Research
    • /
    • v.33 no.4
    • /
    • pp.151-160
    • /
    • 2008
  • In Korean nuclear power plants (NPPs), two thermoluminescent dosimeters (TLD) were provided to workers who work in an inhomogeneous radiation field; one on the chest and the other on the head. In this way, the effective dose for radiation workers at NPPs was determined by the high deep dose between two radiation dose from these TLDs. This represented a conservative method of evaluating the degree of exposure to radiation. In this study, to prevent the overestimation of the effective dose, field application experiments were implemented using two-dosimeter algorithms developed by several international institutes for the selection of an optimal algorithm. The algorithms used by the Canadian Ontario Power Generation (OPG) and American ANSI HPS N13.41, NCRP (55/50), NCRP (70/30), EPRI (NRC), Lakslumanan, and Kim (Texas A&M University) were extensively analyzed as two-dosimeter algorithms. In particular, three additional TLDs were provided to radiation workers who wore them on the head, chest, and back during maintenance periods, and the measured value were analyzed. The results found no significant differences among the calculated effective doses, apart from Lakshmanan's algorithm. Thus, this paper recommends the NCRP(55/50) algorithm as an optimal two-dosimeter algorithm in consideration of the solid technical background of NCRP and the convenience of radiation works. In addition, it was determined that a two-dosimeter is provided to a single task which is expected to produce a dose rate of more than 1 mSv/hr, a difference of dose rates depending on specific parts of the body of more than 30%, and an exposure dose of more than 2 mSv.

Outpatient Radioablation Therapy for Thyroid Cancer Patients with Minimal Radiation Exposure to the Family Members (갑상선암 환자의 방사선옥소 외래치료시 가족 구성원의 방사선량 측정)

  • Park, Hee-Myung;Jang, Jung-Woong;Yang, Hee-Chul;Kim, Young-Gook
    • Nuclear Medicine and Molecular Imaging
    • /
    • v.41 no.3
    • /
    • pp.218-225
    • /
    • 2007
  • Purpose: Postoperative thyroid remnant radioablation therapy is necessary to reduce the recurrence and mortality rates as well as to prepare the patients for a proper long term surveillance of well-differentiated thyroid cancers. The radiation safety rules of the government require the patient to be isolated in a hospital if the expected radiation exposure to the family members would be greater than 5 mSv (500 mRem). The purpose was to measure the radiation received by the family members of patients who received large doses of NaI-131. Material and Methods: We have administered 12 therapy doses ranging from 3.70-5.55 GBq (100 to 150 mCi) to 11 patients, and released them immediately if they met the radiation safety criteria. Informed consent was obtained from the subjects prior to the therapy, and each of them agreed to follow written radiation safety instructions. TLD badges were used to measure the radiation dose received by the family members and the room adjacent to the patient's bed room during the first 72 hours. Results: The average dose received by the family members who spent the most time in the closest distance with the patients was 0.04 mSv with a range of 0.01-0.17 mSv. Even the highest dose was only about 3% of the limit set by the government. The average radiation dose to the outer wall of the patient's room was 0.15 mSv. Conclusion: It is concluded that I-131 ablation therapy can be administered to outpatients safely to thyroid cancer patients who meet the established radiation safety criteria and follow the instructions.

Differences in Gene Expression Profiles Reflecting Differences in Drug Sensitivity to Acetaminophen in Normal and Transformed Hepatic Cell Lines In vitro

  • Jeong, Youn-Kyoung;Kang, Jin-Seok;Kim, Joo-Whan;Suh, Soo-Kyung;Lee, Michael;Kim, Seung-Hee;Lee, Sang-Kook;Park, Sue-Nie
    • Molecular & Cellular Toxicology
    • /
    • v.5 no.1
    • /
    • pp.32-43
    • /
    • 2009
  • Acetaminophen (APAP) overdose is known to cause severe hepatotoxicity mainly through the depletion of glutathione. In this study, we compared the cytotoxic effects of APAP on both a normal murine hepatic cell line, BNL CL.2, and its SV40-transformed cell line, BNL SV A.8. Gene expression profiles for APAP-treated cells were also obtained using microarray and analyzed to identify differences in genes or profiles that may explain the differences of susceptibility to APAP in these cell lines. These two cell lines exhibited different susceptibilities to APAP (0-$5,000{\mu}M$); BNL SV A.8 cells were more susceptible to APAP treatment compared to BNL CL.2 cells. A dose of $625{\mu}M$ APAP, which produced significant differences in cytotoxicity in these cell lines, was tested. Microarray analysis was performed to identify significant differentially expressed genes (DEGs) irrespective of APAP treatment. Genes up-regulated in BNL SV A.8 cells were associated with immune response, defense response, and apoptosis, while down-regulated genes were associated with catalytic activity, cell adhesion and the cytochrome P450 family. Consistent with the cytotoxicity data, no significant DEGs were found in BNL CL.2 cells after treatment with $625{\mu}M$ APAP, while cell cycle arrest and apoptosis-related genes were up-regulated in BNL SV A.8 cells. Based on the significant fold-changes in their expression, a genes were selected and their expressions were confirmed by quantitative real-time RT-PCR; there was a high correlation between them. These results suggest that gene expression profiles may provide a useful method for evaluating drug sensitivity of cell lines and eliciting the underlying molecular mechanism. We further compared the genes identified from our current in vitro studies to the genes previously identified in our lab as regulated by APAP in both C57BL/6 and ICR mice in vivo. We found that a few genes are regulated in a similar pattern both in vivo and in vitro. These genes might be useful to develop as in vitro biomarkers for predicting in vivo hepatotoxicity. Based on our results, we suggest that gene expression profiles may provide useful information for elucidating the underlying molecular mechanisms of drug susceptibility and for evaluating drug sensitivity in vitro for extrapolation to in vivo.

Shape Magnetic Anisotropy on Magnetic Easy Axis of NiFe/Cu/NiFe/IrMn Spin Valve Thin Film (NiFe/Cu/NiFe/IrMn 스핀밸브 박막소자의 자화 용이축에 따른 형상 자기이방성)

  • Choi, Jong-Gu;Kwak, Tae-Joon;Lee, Sang-Suk;Sim, Jung-Taek
    • Journal of the Korean Magnetics Society
    • /
    • v.20 no.2
    • /
    • pp.35-40
    • /
    • 2010
  • The GMR-SV (giant magnetoresistance-spin valve) device depending on the micro patterned features according to two easy directions of longitudinal and transversal axes has been studied. The GMR-SV multilayer structure was Ta(5 nm)/NiFe(8 nm)/Cu(2.3 nm)/NiFe(4 nm)/IrMn(8 nm)/Ta(2.5 nm). The applied anisotropy direction of the GMR-SV thin film was performed under the magnitude of 300 Oe using by permanent magnet during the deposition. The size of micro patterned device was a $1\;{\times}\;18\;{\mu}m^2$ after the photo lithography process. In the aspects of the shape magnetic anisotropy effect, there are two conditions of fabrication for GMR-SV device. Firstly, the direction of sensing current was perpendicular to the magnetic easy axis of the pinned NiFe/IrMn bilayer with the transversal direction of device. Secondly, the direction of shape magnetic anisotropy was same to the magnetic easy axis of the free NiFe layer with the longitudinal direction of device.

Calculation of Route Doses for Korean-based International Airline Routes using CARI-6 and Estimation of Aircrew Exposure (CARI-6를 이용한 국제선 노선별 선량 및 항공승무원의 피폭선량 평가)

  • Hong, J.H.;Kwon, J.W.;Jung, J.H.;Lee, J.K.
    • Journal of Radiation Protection and Research
    • /
    • v.29 no.2
    • /
    • pp.141-150
    • /
    • 2004
  • Dose rate characteristics of cosmic radiation field at flight altitudes were analyzed and the route doses to the personnels on board due to cosmic-ray were calculated for Korean-based commercial international airline routes using CARI-6. Annual individual doses to aircrew and the collective effective dose of passengers were estimated by applying the calculated route doses to the flight schedules of aircrew and the air travel statistics of Korea. The result shows that the annual doses to aircrew, around 2.62 mSv, exceed the annual dose limit of public and are comparable to doses of the group of workers occupationally exposed. Therefore it is necessary to consider the frequent flyers as well as the aircrew as the occupational exposure group. The annual collective dose to 11 million Korean passengers in 2001 appeared to be 136 man-Sv. The results should be modified when the dose rates of cosmic radiation at high altitude are revised by taking into account the changes in the radiation weighting factors for protons and neutrons as given in ICRP 92.

Determination of Rhodium by Inverted Catalytic Hydrogen peak as Analytical peak (뒤집힌 촉매수소 전류 봉우리를 이용한 로듐의 정량)

  • Kwon, Young-Soon;Lim, Kyong-Hee
    • Analytical Science and Technology
    • /
    • v.16 no.4
    • /
    • pp.269-276
    • /
    • 2003
  • A new type of stripping voltammetry, inverted catalytic stripping voltammetry $IC_tSV$, is introduced. The rhodium-formaldehyde complex in hydrochloric acid gives an inverted catalytic hydrogen peak (reduction current peak during positive-going scan). The characteristics of the inverted peak were studied. By using the peak as analytical peak the detection limit of $1.2{\times}10^{-10}M$ Rh (50s preconcentration) can be reached at the optimal conditions: 0.015% (W/V) HCHO-0.42 M HCl; accumulation potential, -1.1 V; scan rate, 100 mV/s.

The Radiation Exposure of Radiographer Related to the Location in C-arm Fluoroscopy-guided Pain Interventions

  • Chang, Young Jae;Kim, Ah Na;Oh, In Su;Woo, Nam Sik;Kim, Hae Kyoung;Kim, Jae Hun
    • The Korean Journal of Pain
    • /
    • v.27 no.2
    • /
    • pp.162-167
    • /
    • 2014
  • Background: Although a physician may be the nearest to the radiation source during C-arm fluoroscope-guided interventions, the radiographer is also near the fluoroscope. We prospectively investigated the radiation exposure of radiographers relative to their location. Methods: The effective dose (ED) was measured with a digital dosimeter on the radiographers' left chest and the side of the table. We observed the location of the radiographers in each procedure related to the mobile support structure of the fluoroscope (Groups A, M and P). Data about age, height, weight, sex, exposure time, radiation absorbed dose (RAD), and the ED at the radiographer's chest and the side of the table was collected. Results: There were 51 cases for Group A, 116 cases for Group M and 144 cases for Group P. No significant differences were noted in the demographic data such as age, height, weight, and male to female ratio, and exposure time, RAD and ED at the side of the table. Group P had the lowest ED ($0.5{\pm}0.8{\mu}Sv$) of all the groups (Group A, $1.6{\pm}2.3{\mu}Sv$; Group M, $1.3{\pm}1.9{\mu}Sv$; P < 0.001). The ED ratio (ED on the radiographer's chest/ED at the side of the table) of Group A was the highest, and the ED radio of Group P was the lowest of all the groups (Group A, $12.2{\pm}21.5%$; Group M, $5.7{\pm}6.5%$; Group P, $2.5{\pm}6.7%$; P < 0.001). Conclusions: Radiographers can easily reduce their radiation exposure by changing their position. Two steps behind the mobile support structure can effectively decrease the exposure of radiographers by about 80%.

Evolving live load criteria in bridge design code guidelines - A case study of India based on IRC 6

  • Karthik, P.;Sharma, Shashi Kant;Akbar, M. Abdul
    • Structural Monitoring and Maintenance
    • /
    • v.9 no.1
    • /
    • pp.43-57
    • /
    • 2022
  • One of the instances which demand structural engineer's greatest attention and upgradation is the changing live load requirement in bridge design code. The challenge increases in developing countries as the pace of infrastructural growth is being catered by the respective country codes with bigger and heavier vehicles to be considered in the design. This paper presents the case study of India where Indian Roads Congress (IRC) codes in its revised version from 2014 to 2017 introduced massive Special vehicle (SV) around 40 m long and weighing 3850 kN to be considered in the design of road bridges. The code does not specify the minimum distance between successive special vehicles unlike other loading classes and hence the consequences of it form the motivation for this study. The effect of SV in comparison with Class 70R, Class AA, Class A, and Class B loading is studied based on the maximum bending moment with moving load applied in Autodesk Robot Structural Analysis. The spans considered in the analysis varied from 10 m to 1991 m corresponding to the span of Akashi Kaikyo Bridge (longest bridge span in the world). A total of 182 analyses for 7 types of vehicles (class B, class A, class 70R tracked, class 70R wheeled, class AA tracked, AA wheeled, and Special vehicle) on 26 different span lengths is carried out. The span corresponding to other vehicles which would equal the bending moment of a single SV is presented along with a comparison relative to Standard Uniformly Distributed Load. Further, the results are presented by introducing a new parameter named Intensity Factor which is proven to relate the effect of axle spacing of vehicle on the normalized bending moment developed.

An Assessment of the Secondary Neutron Dose in the Passive Scattering Proton Beam Facility of the National Cancer Center

  • Han, Sang-Eun;Cho, Gyuseong;Lee, Se Byeong
    • Nuclear Engineering and Technology
    • /
    • v.49 no.4
    • /
    • pp.801-809
    • /
    • 2017
  • The purpose of this study is to assess the additional neutron effective dose during passive scattering proton therapy. Monte Carlo code (Monte Carlo N-Particle 6) simulation was conducted based on a precise modeling of the National Cancer Center's proton therapy facility. A three-dimensional neutron effective dose profile of the interior of the treatment room was acquired via a computer simulation of the 217.8-MeV proton beam. Measurements were taken with a $^3He$ neutron detector to support the simulation results, which were lower than the simulation results by 16% on average. The secondary photon dose was about 0.8% of the neutron dose. The dominant neutron source was deduced based on flux calculation. The secondary neutron effective dose per proton absorbed dose ranged from $4.942{\pm}0.031mSv/Gy$ at the end of the field to $0.324{\pm}0.006mSv/Gy$ at 150 cm in axial distance.

Electrochemical Behavior and Differential Pulse Polarographic Determination of Rifampicin in the Pharmaceutical Preparations

  • Hahn, Young-Hee;Shin, Sun-Mi
    • Archives of Pharmacal Research
    • /
    • v.24 no.2
    • /
    • pp.100-104
    • /
    • 2001
  • Differential pulse polarographic(DPP) analytical procedure for the rifampicin antibiotic, which can be applied to monitor its synthetic process from the starting antibiotic of rifamycin B or rifamycin SV has been developed based on the electrochemical reduction of an azomethine group. Rifampicin exhibited a cathodic peak due to the azomethine group in the side chain of 3-[(4-methyl-1-piperazinyl)imino]methyl moiety and another cathodic peak due to the carbonyl group in rifamycin SV by DPP. The experimental peak potential shift of an azomethine reduction was -73 mV/pH in the pH range between 3.0 and 7.5, agreeing with involvement of 4 e-and 5 $H^5$ in its reduction. By the cyclic voltammetric(CV) studies, the azomethine and the carbonyl reductions in rifampicin were processed irreversibly on the mercury electrode. The plot of peak currents vs. concentrations of rifampicin ranging $1.0{\times}10^{-7} M~$1.0{\times}10^{-5} M yielded a straight line with a correlation coefficient of 0.9996. The detection limit was $1.0{\times}10^{-8} M with a modulation amplitude of 50 mV DPP has been successfully applied for the determination of rifampicin in the pharmaceutical preparations.

  • PDF