방사선 진단영역에서 방사선사의 부서별 의료피폭의 분석 (An Analysis of the Radiation Exposure of Radiologic Technologists in the Field of Diagnostic Radiology according to Duty Station)

  • 한재진;김승국
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제20권1호
    • /
    • pp.71-75
    • /
    • 1997
  • This study was Investigation that we will become aware of the scattering dose of duty station and TLD value of the radiation exposure by the radiation technologists based on the university hospital located in Kwang ju. The results are followings ; 1. The air of scattering dose in chest, when the number of objects are large, is 2.0 mR in P-A and 4.6 mR in Lat. at the back of X-ray tube 2. Radiologists, radiation exposure in duty station Is 0.22 mSv to 1.96 mSv in general examination, 0.22 mSv to 1.12 mSv in contrast and special examination, 0.26 mSv to 30.96 mSv in angiography, and 0.22 mSv to 0.40 mSv in C.T 3. The value of workig condition reveals 85.5% in general examination, 6% in contrast and special examination, and 5.8% in C.T. When the annual exposure is over 20 mSv, it must be measured again according to ICRP public 60.

  • PDF

광자극발광선량계와 열형광선량계를 이용한 핵의학과 선량 측정비교 (Comparison on the Dosimetry of TLD and OSLD Used in Nuclear Medicine)

  • 이왕희;김성철;안성민
    • 한국콘텐츠학회논문지
    • /
    • 제12권12호
    • /
    • pp.329-334
    • /
    • 2012
  • 방사선작업종사자의 개인피폭선량 측정에는 필름뱃지, 열형광선량계, 유리선량계 등이 이용되고 있었으며, 최근 들어 전 세계적으로 광자극발광선량계의 사용이 증가되고 있는 추세이다. 하지만 우리나라에서는 아직 일부에만 적용되고 있으며, 연구도 거의 없는 실정이다. 이에 기존에 가장 많이 사용되고 있던 열형광선량계와 광자극발광선량계를 핵의학과 작업종사자 및 작업구역에서 3개월간 누적선량을 비교해 보았으며, 그 결과 평균 표층선량은 열형광선량계가 1.27mSv, 광자극발광선량계가 2.12mSv로 0.85mSv의 차이가 있었으며, 평균 심부선량은 열형광선량계가 1.33mSv, 광자극발광선량계가 2.06mSv로 0.73mSv의 차이를 보였다. 광자극발광선량계가 표층선량 및 심부선량 모두에서 통계적으로 유의하게(p<0.05) 높게 측정하는 것으로 나타났다.

10MV X선 방사선 치료 시 중성자 선량 분포에 관한 연구 (A Study on the Neutron Dose Distribution in Case of 10 MV X-rays Radiotherapy)

  • 박철수;임청환;정홍량;신성수
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제31권4호
    • /
    • pp.415-417
    • /
    • 2008
  • 현재 방사선치료는 선형가속기에 의하여 대다수 이루어지고 있으며 사용되는 방사선인 광자도 의학의 발전에 의해 고에너지화 고선량화 되고 있다. 본 연구에서는 방사선치료 조사면에서 중성자 측정이 가능한 CR-39를 이용한 중성자 검출법을 이용하였다. 선형가속기에서 발생되는 X선(광자)치료 시 발생 되는 중성자의 선량을 CR-39를 이용한 중성자 검출법을 이용하여 측정하고, 임상적 응용으로 고에너지 광자를 이용하여 암 치료에 사용할 때 중성자의 발생이 환자치료 선량과 연관되는 어떤 문제를 발생시키는지를 연구한 결과는 다음과 같다. 속중성자의 경우 광자 1Gy 조사 시 평균 0.35mSv, 2Gy 조사 시 평균 0.65mSv, 5Gy 조사 시 평균 1.82mSv, 열중성자의 경우 광자 1Gy 조사 시 평균 0.26mSv, 2Gy 조사 시 평균 0.56mSv, 5Gy 조사 시평균 1.23mSv의 중성자 발생하였다. Wedge Filter를 사용하여 중성자의 발생을 측정한 결과 Wedge Filter를 사용했을 때 중성자의 발생이 증가하였다. 고선량을 요구하는 SRS Cone을 사용했을 때에는 기존의 실험결과 보다 많은 중성자가 검출되었다. 속중성자의 경우 광자 5Gy 조사 시 평균 2.85mSv, 열중성자의 경우 광자 5Gy 조사 시 평균 1.37mSv의 중성자가 발생하였다. 일반 치료 시 광자 5Gy 조사했을 때 보다 속중성자의 경우 약 1.6배, 열중성자의 경우 약 1.12배 정도의 중성자가 더 발생하는 것으로 나타났다.

  • PDF

파노라마 촬영시 눈과 갑상선에 미치는 표면선량에 관한 연구 - TLD, PLD 중심으로 - (A study on the effects of scattering dose on eyes and thyroid for panoramagraphy - Focus on TLD and PLD -)

  • 동경래
    • 한국콘텐츠학회:학술대회논문집
    • /
    • 한국콘텐츠학회 2009년도 춘계 종합학술대회 논문집
    • /
    • pp.1118-1123
    • /
    • 2009
  • 파노라마 촬영 시 눈과 갑상선의 표면선량 실험은 광주지역 10개 병원을 대상으로 열형광선량계(Thermoluminescent dosimeter, TLD)와 형광유리선량계(Photoluminescent dosimeter, PLD)를 이용하여 각각 병원에서 사용하는 조건으로 측정(measurement)하였다. ICRP 60과 ICRP 73에서 권고한 눈에 대한 허용기준은 15mSv, 갑상선에 대한 허용기준은 연간 1mSv이다. 왼쪽 눈(Left Eye)의 TLD와 PLD값은 각각 0.19mSv와 0.24mSv, 오른쪽 눈(Right Eye)의 TLD와 PLD의 값은 0.23mSv와 0.25mSv, 갑상선의 TLD와 PLD의 값은 0.08mSv와 0.25mSv로 허용기준치를 초과하지 않았다. 또한 각 장기에 대한 TLD와 PLD의 비교에서는 왼쪽 눈과 갑상선이 유의한 차이가 있다고 볼 수 있고(p<0.01), 오른쪽 눈은 유의한 차이가 없다고 볼 수 있다(p>0.05). 각 병원에서 사용하는 파노라마 기기로 눈과 갑상선에 미치는 선량을 TLD와 PLD로 측정 하였을 때 눈과 갑상선의 표면선량은 ICRP 60에서 권고한 선량을 넘지 않았지만, 확률적 영향이 일어날 수 있으므로 모든 준위의 선량에 대해서 고려되어야 한다.

  • PDF

환자에게 주입된 18F-FDG 의한 선량 평가에 대한 연구 (A Study on Dose Assessment by 18F-FDG injected into Patients)

  • 김창주;김장오;정근우;신지혜;이지은;전찬희;민병인
    • 한국방사선학회논문지
    • /
    • 제14권4호
    • /
    • pp.467-475
    • /
    • 2020
  • 본 연구는 PET 검사 중 방사성의약품인 18F-FDG에 대한 선량을 평가하여 환자와 보호자의 방사선에 대한 불안감을 완화하고, 의료기관 인력 및 공간 확보 문제, 건강검진으로 인한 무분별한 검사 진행을 최소화하는 데 그 목적이 있다. 선량평가는 방사선조직가중치 중 높은 조직 세 부위인 경부(갑상선), 흉부(심장), 하복부(생식선) 위치에 열형광선량계(TLD)와 전자개인선량계(EPD)를 이용하여 측정하였다. 또한, GM 계수기와 전리함을 이용하여 공간선량률과 소변에서의 방사능을 측정하였다. 그 결과는 다음과 같다. 첫째, 개인선량계인 TLD는 경부에서 0.0425±0.0277 mSv, 흉부에서 0.0485±0.0386 mSv, 하복부에서 0.0485±0.0436 mSv 측정되었고 방사선 민감도에 따른 심부선량 차이는 거의 없었다. EPD는 경부 위치에서 직후 0.942±0.141 mSv/h, 120분 후 0.192±0.031 mSv/h로 측정되었다. 흉부 위치에서 직후 0.516±0.085 mSv/h, 120분 후 0.128±0.040 mSv/h로 측정되었다. 하복부 위치에서 직후 0.468±0.091 mSv/h, 120분 후 0.105±0.021 mSv/h로 측정되었다. GM 계수기에서 공간선량률은 직후 0.041±0.005 mSv/h, 120분 후 0.014±0.002 mSv/h로 측정되었다. 전리함을 이용한 소변 내 방사능은 60분 후 0.113±0.24 MBq/cc, 120분 후 0.063±0.13 MBq/cc로 측정되었다. 이러한 결과로 볼 때 18F-FDG를 투여하고 PET 검사가 끝나는 2시간 후 선량 재평가를 하고 귀가 시점을 정하도록 해야 하며 보호자와의 접촉도 피해야 한다. 또한, 환자와 보호자에게 충분한 설명과 함께 피폭선량 예상 값을 제공하여 무분별한 검사를 지양해야 하도록 할 필요가 있을 것으로 판단된다. 본 연구에서 실측 실험한 데이터를 통해 환자와 가족들이 방사선에 대한 불안감을 해소하기를 바라며, 방사선 종사자의 피폭관리 시스템과 제도적 개선을 통해 의료방사선 발전에 힘이 되리라 기대한다.

Radiological safety assessment of lead shielded spent resin treatment facility with the treatment capacity of 1 ton/day

  • Byun, Jaehoon;Choi, Woo Nyun;Kim, Hee Reyoung
    • Nuclear Engineering and Technology
    • /
    • 제53권1호
    • /
    • pp.273-281
    • /
    • 2021
  • The radiological safety of the spent resin treatment facility with a14C treatment capacity of 1 ton/day was evaluated in terms of the external and internal exposure of worker according to operation scenario. In terms of external dose, the annual dose for close work for 1 h/day at a distance of more than 1 m (19.8 mSv) satisfied the annual dose limit. For 8 h of close work per day, the annual dose exceeded the dose limit. For remote work of 2000 h/year, the annual dose was 14.4 mSv. Lead shielding was considered to reduce exposure dose, and the highest annual dose during close work for 1 h/day corresponded to 6.75 mSv. For close work of 2000 h/year and lead thickness exceeding 1.5 cm, the highest value of annual dose was derived as 13.2 mSv. In terms of internal exposure, the initial year dose was estimated to be 1.14E+03 mSv when conservatively 100% of the nuclides were assumed to leak. The allowable outflow rate was derived as 7.77E-02% and 2.00E-01% for the average limit of 20 mSv and the maximum limit of 50 mSv, respectively, where the annual replacement of the worker was required for 50 mSv.

광주광역시 광산구 소재 초등학교 라돈가스 농도 계측 (Elementary School in Gwangju Gwangsan Radon gas Density Measurement)

  • 안병주;오지훈
    • 한국방사선학회논문지
    • /
    • 제8권4호
    • /
    • pp.211-216
    • /
    • 2014
  • 자연방사선 물질인 라돈($^{222}Rn$)은 암석이나 토양 또는 건축자재 중에 들어있는 우라늄($^{238}U$)이 몇 단계의 방사성 붕괴 과정을 거친 후 생성되는 무색무취의 불활성기체로 지하 근무지나 밀폐된 공간과 같은 곳에서 잘 축적된다. 호흡기를 통하여 허파로 유입되고 라돈의 딸핵종이 허파나 기관지에 침적되어 폐암을 일으키는 원인이 된다. 본 연구에서는 초등학교 교실내의 공기 중 라돈가스농도을 비교하였으며 계측된 값을 이용하여 연간내부피폭량을 계산하였다. 초등학교 교실에서 측정된 라돈가스 피폭은 최소 5개교에서 층별 평균치가 창문을 닫을 때의 경우 1층 0.56mSv, 2층 0.48mSv, 3층 0.384mSv의 평균치가 나왔으며, 창문을 열었을 때의 경우 1층과 2층은 0.31mSv 수치로 같고 3층은 0.296mSv로평균치가 나왔다. 라돈에 대한 인체 피폭은 1층에서 피폭이 많고 3층에서는 피폭이 적었다. 창문을 닫았을 때의 경우 최대 0.56mSv 최소 0.384mSv로 자연방사선에 의한 연간피폭량에 2.4mSv 16%에서 23.3%를 차지하고 있다. 창문을 열었을 때의 경우 최대 0.31mSv 최소 0.296mSv로 연간피폭량 2.4mSv의 12.3%에서 12.91%를 차지한다. 결과로 보아 라돈가스 계측을 실시한 5개 초등학교의 경우 국내의 라돈기준치 이하로 나왔으며 내부피폭 역시 정상범위 내에 속한다. 사람에게 있어서 방사선피폭이 적으면 적을수록 인체에 대한 영향이 줄어들기 때문에 초등학교 교실 내에서 창문을 자주 환기한다면 즉, 공기 중 라돈농도를 최대한 줄인다면 라돈가스에 대한 피폭량을 줄일 수 있을 것이며 면역력이 약한 초등학생에게 도움이 될 것이다. 실험에 있어서 향후 더 많은 초등학교 기관에 대해 라돈가스 조사가 이루어지고 그에 따른 조치를 행한다면 보다 더 안전한 초등학교 건물시설 확립에 도움이 될 것이라 생각된다.

Dose analysis of nearby residents and workers due to the emission accident of gaseous radioactive material at the spent resin mixture treatment facility

  • Jaehoon Byun;Seungbin Yoon;Hee Reyoung Kim
    • Nuclear Engineering and Technology
    • /
    • 제55권12호
    • /
    • pp.4543-4553
    • /
    • 2023
  • The dose from a possible accident at a microwave-based spent resin mixture treatment facility that was to be installed and operated at the Wolsong nuclear power plant was analyzed to evaluate the radiological safety prior to its installation and operation. The dose to which workers and nearby residents are likely to be exposed was calculated based on the atmospheric dispersion and deposition factors using the XOQDOQ code. The highest atmospheric dispersion factors were 1.349E-05 s/m3 (workers) and 1.534E-06 s/m3 (residents). The highest doses due to emissions from the mock-up tank before operation were 1.91E-06 mSv (workers) and 1.78E-07 mSv (residents). Even after 3 h of operation, emissions from the mock-up tank had the greatest impact ranging from 4.63E-08 to 1.24E-06 mSv (workers) and 2.74E-10 to 1.16E-07 mSv (residents), respectively. The doses were 7.09E-09-4.55E-07 mSv and 4.18E-11-4.25E-08 mSv at 4-5 h of operation, and the maximum doses after operation reached 5.69E-07 mSv and 5.31E-08 mSv for the workers and residents, respectively. Even at the exclusion area boundary (EAB), 4.76E-08-9.51E-07 mSv (annual dose:9.52E-05–1.90E-03 mSv/y) was below the dose limit of the EAB, and the safety of the facility installation inside the NPP was confirmed.

Conversion coefficients for the estimation of effective dose in cone-beam CT

  • Kim, Dong-Soo;Rashsuren, Oyuntugs;Kim, Eun-Kyung
    • Imaging Science in Dentistry
    • /
    • 제44권1호
    • /
    • pp.21-29
    • /
    • 2014
  • Purpose: To determine the conversion coefficients (CCs) from the dose-area product (DAP) value to effective dose in cone-beam CT. Materials and Methods: A CBCT scanner with four fields of view (FOV) was used. Using two exposure settings of the adult standard and low dose exposure, DAP values were measured with a DAP meter in C mode ($200mm{\times}179mm$), P mode ($154mm{\times}154mm$), I mode ($102mm{\times}102mm$), and D mode ($51mm{\times}51mm$). The effective doses were also investigated at each mode using an adult male head and neck phantom and thermoluminescent chips. Linear regressive analysis of the DAP and effective dose values was used to calculate the CCs for each CBCT examination. Results: For the C mode, the P mode at the maxilla, and the P mode at the mandible, the CCs were 0.049 ${\mu}Sv/mGycm^2$, 0.067 ${\mu}Sv/mGycm^2$, and 0.064 ${\mu}Sv/mGycm^2$, respectively. For the I mode, the CCs at the maxilla and mandible were 0.076 ${\mu}Sv/mGycm^2$ and 0.095 ${\mu}Sv/mGycm^2$, respectively. For the D mode at the maxillary incisors, molars, and mandibular molars, the CCs were 0.038 ${\mu}Sv/mGycm^2$, 0.041 ${\mu}Sv/mGycm^2$, and 0.146 ${\mu}Sv/mGycm^2$, respectively. Conclusion: The CCs in one CBCT device with fixed 80 kV ranged from 0.038 ${\mu}Sv/mGycm^2$ to 0.146 ${\mu}Sv/mGycm^2$ according to the imaging modes and irradiated region and were highest for the D mode at the mandibular molar.

GEANT4를 이용한 $^{99m}Tc$ 주입시 손가락 선량계산 (Finger Doses Received during $^{99m}Tc$ Injections Calculated with GEANT4)

  • 한동현;강상구;김종일
    • Journal of Radiation Protection and Research
    • /
    • 제33권1호
    • /
    • pp.41-46
    • /
    • 2008
  • [ $^{99m}Tc$ ]를 주사할 때 시술자의 손가락에 흡수되는 방사선량을 예측하기 위해, GEANT4를 이용하여 초당 370 MBq의 방사능량을 가지는 0.4 mL 체적의 $^{99m}Tc$ 선원을 대상으로 각 손가락에 대한 등가선량을 구하였다. 시뮬레이션 결과, 오른손 엄지($0.29\;{\mu}Sv{\cdot}sec^{-1}$), 검지($1.19\;{\mu}Sv{\cdot}sec^{-1}$), 중지($1.07\;{\mu}Sv{\cdot}sec^{-1}$), 왼손 엄지($4.36\;{\mu}Sv{\cdot}sec^{-1}$), 검지($3.37\;{\mu}Sv{\cdot}sec^{-1}$)의 등가선량을 얻을 수 있었다. 이와 같은 계산 결과는 $^{99m}$Tc 주입시 시술자의 손가락에 흡수되는 선량을 예측할 수 있는 유용한 기초자료로 활용될 수 있을 것이다.