• Title/Summary/Keyword: lumbar spine measurement

Search Result 74, Processing Time 0.026 seconds

Development of Bib Pants Design and Pattern for Cycling Smart Wear (사이클링 스마트웨어 제작을 위한 빕 팬츠 디자인 및 패턴 개발)

  • Yunyoung, Kim;Byeongha, Ryu;Woojae, Lee;Kikwang, Lee;Rira, Kim
    • Journal of Fashion Business
    • /
    • v.26 no.5
    • /
    • pp.91-104
    • /
    • 2022
  • In this study, a cycling smart wear for measuring cycling posture and motion was developed using a three-dimensional motion analysis camera and an IMU inertial sensor. Results were compared according to parts to derive the optimal smart device attachment location, enabling correct posture measurement and cycle motion analysis to design a pattern. Conclusions were as follows: 1) 'S-T8' > 'S-T10' > 'S-L4' was the most significant area for each lumbar spine using a 3D motion analysis system with representative posture change (90°, 60°, 30°) to derive incisions and size specifications; 2) the part with the smallest relative angle change among significant section reference points during pattern design was applied as a reference point for attaching a cycling smart device to secure detachable safety of the device. Optimal locations for attaching the cycling device were the "S-L4" hip bone (Sacrum) and lumbar spine No. 4 (Lumbar 4th); 3) the most suitable sensor attachment location for monitoring knee induction-abduction was the anatomical location of the rectus femoris; 4) a cycling smart wear pattern was developed without incision in the part where the sensor and electrode passed. The wearing was confirmed with 3D CLO. This study aims to provide basic research on exercise analysis smart wear, to expand the smart cycling area that could only be realized with smart devices and smart watches attached to current cycles, and to provide an opportunity to commercialize it as cycling smart wear.

The Effect of Flexion-distraction Technique and Drop Technique on Pain and Sacral Angle of Patients with Lumbar Spine Herniated Intervertebral Disc (굴곡-신연기법과 낙차 교정법이 허리 척추사이원반 탈출증 환자의 시각적 상사 척도 및 엉치뼈 각에 미치는 영향)

  • Oh, Hyun-Ju;Choi, Seok-Joo;Lee, Kwan-Sub;Choi, Ji-Oun
    • Journal of Korean Physical Therapy Science
    • /
    • v.25 no.3
    • /
    • pp.9-16
    • /
    • 2018
  • Background: In order to find out the effect of therapy methods through Flexion-distraction technique and drop technique on pain, sacral angle of patients with lumbar herniated intervertebral disc targeting patients with lumbar herniated intervertebral disc due to L5-S1. Method: This study was to present the directivity of the therapy method for lumbar herniated intervertebral disc by comparing and analyzing the spinal decompression therapy and provide an effective treatment method to patients with lumbar herniated intervertebral disc by identifying the therapeutic effect of Flexion-distraction technique and drop technique. The research period is March 1, 2018 to June 30, 2018 and subjects are the patients diagnosed as lumbar herniated intervertebral disc due to L5-S1 by their doctor through clinical findings and medical equipment such as X-ray, CT, MRI etc. Among patients who visited and hospitalized in S Orthopaedics located in Daegu and 30 female patients with sacral angle of more than $30^{\circ}$ were randomly classified into 15 people and we carried out treatment three times a week for 8 weeks for 15 people in the experimental group applying Flexion-distraction technique and drop technique and 15 people in the control group applying spinal decompression therapy to compare and analyze the changes in pain, sacral angle of patients with lumbar herniated intervertebral disc. Result: According to the results of this study, changes in the Visual Analogue Scale showed statistically significant differences in both the experimental group and control group(p<.05), while there was statistically significant difference in the comparison between groups before and after measurement of experimental group (p<.05). In the comparison within two groups of sacral angle, both groups showed statistically significant difference(p<.05) but there was no statistically significant difference in the comparison of scores between groups before and after measurement of each group(p>.05). Discussion: All those results the above proved that we need to confirm various benefits of the therapy with the flexion-distraction technique and drop technique, and the findings of the concerned study will possibly become useful information when doctors actually work on a therapy to treat patients with the lumbar herniated intervertebral disc.

Usefulness of volumetric BMD measurement by using low dose CT image acquired on L-spine Bone SPECT/CT (L-spine Bone SPECT/CT에서 획득된 저선량 CT 영상을 이용한 용적 골밀도 결과의 유용성)

  • Hyunsoo Ko;Soonki Park;Eunhye Kim;Jongsook Choi;Wooyoung Jung;Dongyun Lee
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.27 no.2
    • /
    • pp.99-109
    • /
    • 2023
  • Purpose: CT scan makes up for the weak point of the nuclear medicine image having a low resolution and also were used for attenuation correction on image reconstruction. Recently, many studies try to make use of CT images additionally, one of them is to measure the bone mineral density(BMD) using Quantitative CT(QCT) software. BMD exams are performed to scan lumbar and femur with DXA(Dual-Energy X-Ray Absorptiometry) in order to diagnose bone disease such as osteopenia, osteoporosis. The purpose of this study is to identify the usefulness of QCT_BMD analyzed with low dose CT images on L-spine Bone SPECT/CT comparing with DXA_BMD. Materials and Methods: Fifty five women over 50 years old (mean 66.4 ± 9.1) who took the both examinations(L-spine Bone SPECT/CT with SIEMENS Intevo 16 and DXA scan with GE Lunar prodigy advance) within 90 days from April 2017 to July 2022, BMD, T-score and disease classification were analyzed. Three-dimensional BMD was analyzed with low dose CT images acquired on L-spine Bone SPECT/CT scan on Mindways QCT PROTM software and two-dimensional BMD was analyzed on DXA scan. Basically, Lumbar 1-4 were analyzed and the patients who has lesion or spine implants on L-spine were excluded for this study. Pearson's correlation analysis was performed in BMD and T-score, chi-square test was performed in disease classification between QCT and DXA. Results: On 55 patients, the minimum of QCT_BMD was 18.10, maximum was 166.50, average was 82.71 ± 31.5 mg/cm3. And the minimum of DXA-BMD was 0.540, maximum was 1.302, average was 0.902 ± 0.201 g/cm2, respectively. The result shows a strong statistical correlation between QCT_BMD and DXA_BMD(p<0.001, r=0.76). The minimum of QCT_T-score was -5.7, maximum was -0.1, average was -3.2 ± 1.3 and the minimum of DXA_T-score was -5.0, maximum was 1.7, average was -2.0 ± 1.3, respectively. The result shows a statistical correlation between QCT T-score and DXA T-score (p<0.001, r=0.66). On the disease classification, normal was 5, osteopenia was 25, osteoporosis was 25 in QCT and normal was 10, osteopenia was 25, osteoporosis was 20 in DXA. There was under-estimation of bone decrease relatively on DXA than QCT, but there was no significant differences statistically by chi-square test between QCT and DXA. Conclusion: Through this study, we could identify that the QCT measurement with low dose CT images QCT from L-Spine Bone SPECT/CT was reliable because of a strong statistical correlation between QCT_BMD and DXA_BMD. Bone SPECT/CT scan can provide three-dimensional information also BMD measurement with CT images. In the future, rather than various exams such as CT, BMD, Bone scan are performed, it will be possible to provide multipurpose information via only SPECT/CT scan. In addition, it will be very helpful clinically in the sense that we can provide a diagnosis of potential osteoporosis, especially in middle-aged patients.

Correlation Analysis of Factors Affecting the Collimator Size used during Lumbar Spine Lateral Examination in Digital Radiography System (디지털 방사선 장비에서 요추 측면 검사 시 사용되는 조사야 크기에 영향을 미치는 요인의 상관관계 분석)

  • Young-Cheol Joo;Sin-Young Yu
    • Journal of the Korean Society of Radiology
    • /
    • v.18 no.4
    • /
    • pp.345-353
    • /
    • 2024
  • The purpose of this study was to suggest an appropriate collimation size and central X-ray incidence point by analyzing the correlation between the collimation size used in lumbar lateral examination and factors affecting the collimation size. the lumbar lateral examination results of 148 patients suitable for the purpose of this study were analyzed. The measurement method was to set the total horizontal width shown in the image to the size of the irradiation field(collimation) used during the examination. The distance connected vertically from the end of the dorsal field to the apophyseal joint of the third lumbar vertebra(AJD), the distance from the dorsal end of the image field to the center of the body of the third lumbar vertebra(BD), and the distance from the end of the dorsal field of the image to the center of the pedicle of the third lumbar vertebra(PD). The distance was measured. For comparative analysis of the mean values of dependent variables according to gender, age, height, weight, and body mass index, the mean values were compared using the independent samples t test and one-way ANOVA. For post hoc analysis, duncan was used. The correlation between independent and dependent variables was analyzed using Pearson correlation analysis. In this study, statistical significance was set at a p value of 0.05 or lower. The average value of the collimation size during the lumbar spine lateral examination was 252.45 mm, AJD was 102.11 mm, BD was 141.17 mm, and PD was 119.73 mm. The mean values of collimation size, AJD, BD, and PD were larger in men than in women, but statistical significance for the difference in mean values by gender was found only in BD (p<0.05). There was a slight difference in the mean value of each group according to age, but there was no statistical significance (p>0.05). The collimation size and mean values of AJD, BD, and PD according to height, weight, and body mass index differed depending on the independent variables, and the differences were all statistically significant (p<0.05). As a result of the correlation analysis, field size and AJD, BD, and PD showed no correlation with gender and age, a weak positive correlation with height, and a medium positive correlation with weight and body mass index. The results of this study showed that CS was correlated with height, weight, and BMI during lumbar lateral examination. If the entrance point of the central X-ray is moved to the appophyseal joint by considering weight and BMI when adjusting the collimation size in clinical practice, it is expected that the collimation size can be reduced bu about 5%.

Effects of Abdominal Muscle and Pressure on the Spine Stability during Upright Stance Posture - For the Case where Intervertebral Disc Plays the Role of Mechanoreceptor (추간판이 물리적 자극의 수용기 역할을 하는 경우 기립 상태에서 복압 및 복근의 역할이 척추 안전성에 미치는 영향)

  • Choi, Hae-Won;Kim, Young-Eun
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.28 no.1
    • /
    • pp.115-122
    • /
    • 2011
  • Recently, we have proposed a hypothesis that spinal structures have a stress sensor driving feedback mechanism, In the human spine, spinal structure could react to modify muscular action in such a way so as to equalize stress at the disc, therefore reduce the risk of injury, In this analysis, abdominal muscle and abdominal pressure, which were not included in the previous study, were added to identify those effects in spine stability during upright stance posture for the case where the intervertebral disc plays the role of mechanoreceptor, The musculoskeletal FE model was consisted with detailed whole lumbar spine, pelvis, sacrum, coccyx and simplified trunk model. Muscle architecture with 46 local muscles containing paraspinal muscle and 6 rectus abdominal muscles were assigned according to the acting directions. The magnitude of 4kPa was considered for abdominal pressure. Minimization of the nucleus pressure deviation and annulus fiber average tension stress deviation was chosen for cost function. Developed model provide nice coincidence with in-vivo measurement (nucleus pressure). Analysis was conducted according to existence of co-activation of abdominal muscle and abdominal pressure. Antagonistic activity of abdominal muscle produced stability of spinal column with relatively small amount of total muscle force. In contrast to the abdominal muscle, effect of abdominal pressure was not clear that was partly depending on the assumption of constant abdominal pressure.

Correlations of Lumbar and Femoral Bone Mineral Densities with Calcaneal Speed of Sound in Osteoporotic Woman (골다공증 여성에서 요추골 밑 대퇴골 부위의 골밀도와 종골 음속 사이의 상관관계)

  • Lee, Kang-Il;Choi, Min-Joo
    • The Journal of the Acoustical Society of Korea
    • /
    • v.28 no.6
    • /
    • pp.542-547
    • /
    • 2009
  • In this in vivo study, correlations of lumbar and femoral bone mineral densities (BMDs) with calcaneal speed of sound (SOS) were investigated in 36 osteoporotic women. Areal BMDs of the L2-L4 lumbar spine and the right femoral neck were measured by using dual energy X-ray absorptiometry (DEXA). SOS of the right calcaneus was measured by using ultrasound bone densitometry. Pearson's correlation coefficient (r) and level of significance (p) were used to evaluate the correlations between measurements. Lumbar BMD was highly correlated with femoral BMD (r=0.81). Lumbar and femoral BMDs exhibited similar comparable negative correlations with age (r=-0.52 and r=-0.55). A moderate negative correlation was found between calcaneal SOS and age (r=-0.45). Calcaneal SOS was significantly correlated with lumbar and femoral BMDs, with a higher correlation with femoral BMD rather than with lumbar BMD (r=0.54 and r=0.62). However, calcaneal SOS may not be an optimum index for the estimation of BMD of the most important fracture sites, such as the lumbar and the femur, because it showed lower correlations with lumbar and femoral BMDs compared to that with calcaneal BMD. Therefore, the development of a quantitative ultrasound technology for the direct measurement of acoustic properties at the lumbar and the femur is required to estimate BMD of these sites more accurately.

Evaluation of Organ and Effective Dose using A PC-Based Monte Carlo Program in AEC Mode and Fix Mode for the whole spine antero-posterior radiography (전 척추 전.후 방향 검사 시 AEC Mode와 Fix Mode에서 PC-Based Monte Carlo Program을 이용한 장기선량 및 유효선량 평가)

  • Kim, Jeong Jin;Jang, Seong Won;Park, Jang Heum;Lee, Kwan Seob;Ha, Dong Yoon
    • Korean Journal of Digital Imaging in Medicine
    • /
    • v.14 no.2
    • /
    • pp.23-31
    • /
    • 2012
  • There are AEC mode and fix mode to exposure when the whole spine antero-posterior radiography is done by using DR equipment. This study compared the utility of fix mode to AEC mode, by evaluating organ dose and effective dose and by examining the quality of radiographic image. GE DEFINIUM 8000 and ART-200X Rando Phantom manufactured by Flukebiometical were used for this study. The Rando phantom was set in front of wall detector of X-rays equipment. AEC mode was set at 80kVp and Fix mode was set at 80kVp, 25mAs, 32mAs, 40mAs, and 50mAs. Whole spine AP image were aquired by combining C, T-L and L-S spine images obtained through 3 exposures. When obtaining C, T-L and L-S spine images, were checked for Air kerma (mGy) value calculated by UNFORS Xi meter attached at the phantom surface of center of radiation field. The effective and organ doses were compared by PCXMC program (PC-Based Monte Carlo Program). The quality of obtained radiographic image was evaluated visually by 3 radiologists using resolution chart. When the effective doses was calculated based on tissue weighting factor of ICRP-103, 1.278mSv was measured by AEC mode, and Fix mode measured 0.405mSv at 25mAs, 0.518mSv at 32mAs, 0.649mSv at 40mAs, and 0.810mSv at 50mAS. In addition, the organ dose measured with esposure at 25mAs by Fix mode was almost equivalent to the organ dose by AEC mode, at the esophagus, thyroid, oral mucosa, salivaly glands located at the cervical spine part, while the organ dose by Fix mode was in general lower than the organ dose by AEC mode at the other organs. When Fix mode at 32mAs, 40mAs, and 50mAs was compared to AEC mode for organ dose in 26 organs, AEC mode had higher measurement in 21 organs but not for than brain, trachea, thyroid, oral mucosa, and salivaly glands which are located at the cervical spine part. The image quality evaluated by resolution test chart was much higher with AEC mode than the quality with Fix mode at all exposure conditions. However, while the image quality of cervical spine exposured at 50mAs by Fix mode was lower than the quality of AEC mode, thoraco-lumbar spine and lumbo-sacral spine were calculated and the quality was similar to AEC mode. Scoliosis occurs mainly at thoraco-lumbar and lumbo-sacral spine, not at cervical spine. Compared to AEC mode, Using the appropriate protocol (80kVp, 50mAs) of fix mode for whole spine AP radiography was thought to be useful because the image quality of the thoraco-lumar and lumbo-sacral spine was similar on AEC mode, Also organ and effective doses can be decreased with Fix mode. Therefore, It is considered that fix mode can be used properly with AEC mode for whole spine AP radiography when considering patient's body posture.

  • PDF

A Clinical Study on the correlation between Bone Mineral Density (BMD) and Obesity in 480 normal adults (성인남녀 480명에서의 골밀도와 비만의 상관관계에 관한 임상적 연구)

  • Jang Soo-Jin;Kim Jeoung-Yeun;Yook Tae-Han
    • Journal of Acupuncture Research
    • /
    • v.15 no.2
    • /
    • pp.383-392
    • /
    • 1998
  • Osteoporosis is the most common metabolic disease of the bone, and constitutes one of the most important major pubulic health problems world wide. Therefore, in order to be helped early diagnosis, treatment and prevention of osteoporosis, measurement of Bone Mineral Density (BMD) is to be needed. Authors has analysed Bone Mineral Density (BMD) of 480 normal adults who visited woo suk unoversity Oriental Meclical Center from April 1998 to July 1998. The aims of this study is to investigate correlation between Bone Mineral Density (BMD) and age distribution, to examine the correlation between Bone Mineral Density (BMD) and Obesity. The results were as follows. 1. In distribution of age, the peak bone density of lumbar spine was noted around 30 years, and the peak bone density of the femoral neck was noted around 20 years. The age related loss of bone density follows soon after peak density. And the signifficant difference was revealed between lumbar spine and femoral neck bone density (p<0.001) 2. In distribution of sex, the bone density in male was signifficantly higher than in female (p<0.001). 3. In the correlation between Bone Mineral Density (BMD) and Obesity, Bone Mineral Density (BMD) in obese group was signifficantly higher than in non-obese group. Especially, in female from 50 up to 69 years, BMD had a positive correlation with Body mass index(BMI).

  • PDF

The association of potassium intake with bone mineral density and the prevalence of osteoporosis among older Korean adults

  • Ha, Jinwoo;Kim, Seong-Ah;Lim, Kyungjoon;Shin, Sangah
    • Nutrition Research and Practice
    • /
    • v.14 no.1
    • /
    • pp.55-61
    • /
    • 2020
  • BACKGROUND/OBJECTIVES: Osteoporosis is characterized by low bone mass and results in vulnerability to fracture. Calcium and vitamin D are known to play an important role in bone health. Recently, potassium has been identified as another important factor in skeletal health. We examined the link between potassium intake and bone health among the Korean older adult population. SUBJECTS/METHODS: This retrospective, cross-sectional study included 8,732 men and postmenopausal women over 50 years old who completed the Korean National Health and Nutrition Survey (KNHANES) between 2008 and 2011. Potassium consumption was evaluated using a 24-hour recall method. Bone mineral density (BMD) was measured at three sites (total hip, femur neck, and lumbar spine) by dual-energy X-ray absorptiometry (DEXA). Multinomial logistic regression was used to examine the link between potassium intake and prevalence of osteoporosis and osteopenia, after controlling for potential confounding variables. RESULTS: The BMD of the total femur and Ward's triangle were significantly different according to the potassium intake among men (P = 0.031 and P = 0.010, respectively). Women in the top tertile for potassium intake showed higher BMD than those in the bottom tertile at all measurement sites (all P < 0.05). Daily potassium intake was significantly related to a decreased risk of osteoporosis at the lumbar spine in postmenopausal women (odds ratios: 0.68, 95% confidence interval: 0.48-0.96, P trend = 0.031). However, the dietary potassium level was not related to the risk of osteoporosis in men. CONCLUSION: Current findings indicate that higher dietary potassium levels have a favorable effect on bone health and preventing osteoporosis in older Korean women.

Comparison of Lumbar Joint Reposition Error When Sitting in Upright and Slouched Positions for Five Minutes (5분 동안 바로 앉은 자세와 구부린 앉은 자세 시 허리 관절재위치 오류의 비교)

  • Ji, Myung-Ki;Choung, Sung-Dae;Park, Kyue-Nam;Kwon, Oh-Yun
    • Physical Therapy Korea
    • /
    • v.20 no.2
    • /
    • pp.20-27
    • /
    • 2013
  • The purpose of this study was to compare the slouched and upright sitting positions on lumbar joint reposition error (LJRE). Twenty subjects without low back pain were recruited for this study and, using a random number table, were randomly assigned to two groups; the upright sitting position group (UP group) and the slouched sitting position group (SP group). UP group was first asked to sit in an upright position and the SP group to sit in a slouched position as an intervention, and then the LJRE of both groups was measured at the neutral sitting position (lumbar flexion $0^{\circ}$). The measurement of the LJRE was repeated after one day. The sitting positions were performed for five minutes each and the LJRE was measured using an electronic goniometer. An independent t-test was used to compare the LJRE of both groups after each sitting position and after one day. The results of this study showed that the LJRE after an intervention in the UP group was lower than in the SP group (p<.05) and the LJRE after one day in the UP group was lower than in the SP group (p<.05). The findings of this study indicate that the upright sitting position can be applied to decrease LJRE, compared with the slouched sitting position. These findings also support that the upright sitting position reduces the potential for proprioceptive loss.