• Title/Summary/Keyword: lower tester

Search Result 275, Processing Time 0.023 seconds

A Study for Improvement of the Testing Methods for Quality Control of Recycled Aggregate (순환골재의 품질평가를 위한 시험방법 개선에 관한 실험적 연구)

  • Jaung, Jae-Dong;Lee, Do-Heun
    • Journal of the Korea Institute of Building Construction
    • /
    • v.8 no.4
    • /
    • pp.105-114
    • /
    • 2008
  • This study investigates the saturation level of surface dryness, quantity of adhesive mortar, and the alien substance content of recycled aggregates for concrete to develop an adequate quality testing method for understanding the properties of recycled aggregates, which differ greatly from preexisting aggregates. For tests that measure the saturation level of surface dryness, where detail methods are applied differently according to the tester, various testing methods from across world were compared and analyzed. This study revealed that when measuring the saturation level of surface dryness of a certain sample, aggregates must be supplemented immediately whenever the height of the sample becomes lower than the measuring mold, and allowing the tamper to free fall on the sample will provide the most accurate results. When measuring the quantity of adhesive mortar of recycled aggregates for concrete, an acid solution was used, and since the quantity of adhesive mortar increases as the particle sizes gets smaller, the sample for testing should represent the entire granularity. Sulfuric acid solution is adequate for immersion, and the concentration should be 20% for best results. According to the alien substance content measurement, which was examined by the naked eye, the error range caused by the difference in particle size was neglectable, and therefore the sample should be $2.5{\sim}5.0mm$ in size concerning the accuracy and measuring time. Also, for coarse recycled aggregates, the sample should amount to 1kg for measuring alien substance content by the naked eye, which proves that assortment by the naked eye is the most adequate method for measuring the alien substance content of a recycled aggregate.

THE INFLUENCE OF WATTAGE AND CURING TIME OF MICROWAVE ENERGY ON PHYSICAL PROPERTIES OF THE DENTURE BASE RESIN (극초단파의 출력과 적용시간이 의치상용 레진의 물리적 성질에 미치는 영향)

  • Jeong, Dae-Sung;Lim, Jang-Seop;Jeong, Chang-Mo;Jeon, Young-Chan
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.37 no.6
    • /
    • pp.767-775
    • /
    • 1999
  • The purpose of this study was to evaluate the effect of wattage and curing time on surface hard-ness, three-point bending strength and internal porosity of microwave curing denture base resin. Two sizes of resin specimens were made of Acron $MC^{(R)}\;;\;3.5{\times}10{\times}60mm$ for surface hardness and three-point bending strength measurement and $5{\times}12{\times}60mm$ for internal porosity measurement. They were cured by microwave energy at varing wattages(500W, 700W) and curing times(2min., 3min., 4min.) to determine if a certain wattage/curing time combination would improve physical properties. Surface hardness was measured with Vikers hardness tester, three-point bend-ing strength with universal testing machine and internal porosity was calculated by measuring the weight in air and in water. The results obtained were as follows: 1. There was no significant difference in percent porosity among experimental groups(p>0.05). 2. 500W/3min. group showed the higher surface hardness than 700W/2, 3, 4min. groups(p<0.05), and 700W/4 min. group showed the lower surface hardness than 500W/2, 3, 4min. groups(p<0.05), but there was no significant difference among others(p>0.05). 3. 500W/3min. group yielded the higher value of bending strength than 500W/2min., 700W/3, 4min. groups(p<0.05), but there was no significant difference among others(p>0.05).

  • PDF

A Comparison of Vastus Medialis Oblique and Vastus Lateralis Electromyography Activities According to Different Tibial Rotation Taping Methods in Healthy People (건강한 성인의 경골 회전 테이핑 방법에 따른 내측사광근과 외측광근의 근활성도 비교)

  • Sung, Gi-Uk;Oh, Yun-Jae;Kim, Suhn-Yeop
    • Journal of the Korean Society of Physical Medicine
    • /
    • v.13 no.2
    • /
    • pp.33-41
    • /
    • 2018
  • PURPOSE: Femur and tibia alignment in the knee joint is important to the biomechanics of lower limb movement. The purpose of this study was to compare vastus medialis oblique (VMO) and vastus lateralis electromyographic muscle activities according to tibial rotation taping methods. METHODS: Twenty-nine healthy subjects (13 males and 16 females) in the 20s, without knee joint-related diseases or disorders, participated in our study. After identifying each subject's dominant foot, the maximal voluntary isometric contraction (MVIC) was determined using a manual muscle tester. The activity of each target muscle was measured at 50% MVIC in isometric muscle contraction and at a $30^{\circ}$ knee flexion position before and after applying internal and external rotation taping by the Mulligan concept and in the neutral position. Non-elastic tape was used to stabilize the tibia rotation position. RESULTS: In the males, VMO muscle activity was significantly increased in the tibia internal rotation position ($47.2{\pm}14.6$, $mean{\pm}SD$) than in the neutral position ($39.3{\pm}14.9$) (p<.05). CONCLUSION: The results of this study indicate that when applying tibia internal rotation taping in healthy males, VMO muscle activity significantly increases during isometric extension of the knee. Therefore, this study provides a basis for selecting the appropriate taping method, in consideration of the available treatments in clinical practice for patients with knee problems.

The Ignition Characteristics of Tree Branches, Barks, Living Leaves and Dead Leaves in Pinus Densiflora and Quercus Dentata (소나무와 떡갈나무의 주요 부위별 착화특성에 관한 연구)

  • Park, Young-Ju;Lee, Si-Young;Sin, Young-Ju;Kim, Su-Young;Kim, Young-Tak;Lee, Hae-Pyeong
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 2008.04a
    • /
    • pp.308-312
    • /
    • 2008
  • In this study, we have carried out test to examine the ignition characteristics, such as a relation of moisture content and combustibility, and ignition temperature using KRS-RG-9000 tester, of significant part of above trees which are representative species of Young Dong Province of Korea. After rainfall, the percentage of moisture content of living leaves and branches was between 52 and 70%. But it was just between 17 and 33% after 144 hours drying at normal temperature. For dead leaves, it was 10% lower than of first. There was a significant difference on ignition characteristics. The hazard of ignition is highest on dead leaves. The ignition temperature of barks and branches is higher so a retard time is long than of living and dead leaves at normal temperature.

  • PDF

Effects of In on the Precipitation Phenomena of Al-2.1Li-2.9Cu Alloy by Differential Scanning Calorimetry (열분석법에 의한 Al-2.1Li-2.9Cu합금이 석출현상에 미치는 In 첨가의 영향)

  • Park, Tae-Won;Song, Young-Beum;Lee, Yong-Yun
    • Journal of the Korean Society for Heat Treatment
    • /
    • v.10 no.4
    • /
    • pp.237-245
    • /
    • 1997
  • A study was conducted to examine the effects of In addition on the precipitation behaviors of Al-2.1Li-2.9Cu alloy by differential scanning calorimetry, transmission electron microscopy and micro-hardness tester. DSC analysis was measured over the temperature range of $25{\sim}550^{\circ}C$ at a heating rate of $2{\sim}20^{\circ}C$/min. The heat evolution peaks due to the formation of GP zone and ${\delta}$'phase shift to higher temperature and the peaks to $T_1$ and ${\theta}$'phases shift to lower temperature by In addition. From this result, it was proved that the formation of GP zone and ${\delta}$'phase is suppresed whereas that of $T_1$ and ${\theta}$'phases are accelerated by the In addition of 0.15wt%. The age hardening curve aged at $190^{\circ}C$ showed that the In bearing alloy(alloy B) has more faster age hardening response and a higher peak hardness than In-free alloy(alloy A), attributed to the fine and homogeneous distribution of $T_1$ and ${\theta}$'phases. The activation energies for the formation of ${\delta}$'phase in In-free and In-bearing alloys are 22.3kcal/mol and 18.6kcal/mol, respectively. Those for $T_1(+{\theta}^{\prime})$ phase of In-free and In-bearing alloys are 24.3 and 37.5kcal/mol, respectively. Quenched-in excess vacancies play an important role to the formation of precipitates.

  • PDF

STUDIES ON THE MICROHARDNESS OF CENTRAL AND LATERAL INCISORS OF THE KOREAN (한국인(韓國人)의 중(中)·측절치(側切齒) 경조직(硬組織) 미소경도(微小硬度)에 관(關)한 연구(硏究))

  • Chung, Jae-Kyoo
    • Restorative Dentistry and Endodontics
    • /
    • v.2 no.1
    • /
    • pp.38-49
    • /
    • 1976
  • Central and lateral incisors of 20, 40 and 60 age groups were bisected pararelly to long axis and middle portion of mesio-distal of teeth. And author measured the hardness of various areas in enamel and dentin with vickers hardness tester. Measured levels were divided into the labio-middle portion, middle portion of incisal edge and linguo-middle portion in enamel and dentin of all age groups. The results were as follows; 1) Total average hardness of enamel for 20, 40 and 60 age groups were respectively Hv. 366.5${\pm}$5.75, Hv. 372.9${\pm}$8.16 and Hv. 389.8${\pm}$10.27. 2) Total average hardness of dentin for 20, 40 and 60 age groups were respectively Hv. 51.0${\pm}$2.14, Hv. 54.0${\pm}$1.87 and Hv. 55.3${\pm}$2.23. 3) Total microhardness values in enamel and dentin of 60 age group was highered than 20 and 40 age groups. 4) The hardness values of enamel and dentin in all age groups were detected lower value on the middle portion of incisal edge than the labio-middle portion and linguo-middle portion. 5) Microhardness values of enamel was highered gradually from the dentinoenamel junction to the outer surface and it lowered at the outermost surface in all age groups. The microhardness values of dentin were the highest values at 600${\mu}$ from dentino-enamel junction and the lowest values at near the pulp chamber in all age groups.

  • PDF

PULPAL ANESTHETIC EFFECT OF INFERIOR ALVEOLAR NERVE BLOCK AND GOW-GATES TECHNIQUE (하악공 전달마취법과 Gow-Gates법의 치수마취 효과)

  • Ahn, Sik-Hwan;Kim, Sung-Kyo
    • Restorative Dentistry and Endodontics
    • /
    • v.22 no.1
    • /
    • pp.278-290
    • /
    • 1997
  • The purposes of this study were to evaluate and compare the pulpal anesthesia induced by an inferior alveolar nerve block and that by Gow-Gates technique, and to investigate the relationship between pulpal anesthesia and intraoral soft tissue responses. After one side of mandibule was anesthetized with inferior alveolar nerve block or Gow-Gates technique using 2 % lidocaine with 1 : 100,000 epinephrine in 19 volunteers of ages between 24 and 29 (16 males and 3 females, average age 25.9 yrs.), electric pulp tests were done on the canine teeth of the anesthetized side and contralateral one before, at 1 min, continued at every 5 minutes until 60 min, and every 10 minutes until 100 min after completion of local anesthetic injection. Degree of pulpal anesthesia was classified as anesthetic failure, possible anesthesia and complete anesthesia by the criteria based on the thresholds to electric pulp test of contralateral canine and the currents of the electric pulp tester. Subjective signs on the lower lip and tongue were checked and prick-pin tests were done on the buccal gingiva of the first molar, buccal and lingual gingiva of the canine tooth at 5, 10 and 20 min after the completion of anesthetic injection. Thresholds to electric pulp test, degree of pulpal anesthesia and relationship between the pulpal anesthesia and soft tissue responses were analyzed with SPSS, paired t-test, Wilcoxon matched-pairs signed-ranks test and correlation analysis. The results were as follows : No significant differences were found in the peak thresholds to electric pulp test, in the induction time to it and in the depth of pulpal anesthesia between inferior alveolar nerve block and Gow-Gates technique (p>0.05). There was no significant relationship between pulpal anesthesia and soft tissue responses in both inferior nerve block and Gow-Gates technique.

  • PDF

Mechanical Properties of Aminosilane-Treated Wood Flour/PVC/Nanoclay Composites (아미노실란으로 개질된 목분/PVC/나노점토 복합재의 기계적 특성)

  • Park, Sol-Mon;Kim, Dae-Su
    • Polymer(Korea)
    • /
    • v.36 no.5
    • /
    • pp.573-578
    • /
    • 2012
  • In general, most physical properties of wood/polyvinyl chloride (PVC) composites are lower than those of corresponding neat PVC resin because of poor interfacial adhesion between the hydrophilic wood flour and hydrophobic PVC. Therefore, in this study, we treated wood flour with three aminosilanes to improve wood/PVC interfacial adhesion strength, and eco-friendly wood/PVC/nanoclay composites were prepared by melt blending the aminosilane-treated wood flour, a heavy metal free PVC compound, and a type of nanoclay. The effects of treating wood flour with the aminosilanes and adding the nanoclay on the mechanical properties of the composites were investigated. Mechanical properties of the composites were investigated by universal testing machine (UTM), izod impact tester, dynamic mechanical analyzer (DMA), and thermomechanical analyzer (TMA). The tensile properties of the composites with the aminosilane-treated wood flour were considerably higher than those of the composites with neat wood flour. Furthermore, a small amount of the nanoclay improved mechanical properties of the composites. The performance of the wood/PVC composites was considerably improved by using the aminosilane-treated wood flour and the nanoclay.

AN EXPERIMENTAL STUDY ON PHYSICAL PROPERTIES OF VARIOUS POSTERIOR RESTORATIVE COMPOSITE RESINS (수종(數種) 구치부(臼齒部) 충전용(充塡用) 복합(複合)레진의 물리적(物理的) 성질(性質)에 관(關)한 실험적(實驗的) 연구(硏究))

  • Park, Sun-Jae;Park, Sang-Jin;Min, Byang-Soon;Choi, Ho-Young
    • Restorative Dentistry and Endodontics
    • /
    • v.12 no.1
    • /
    • pp.7-24
    • /
    • 1986
  • The purpose of this study was to observe the compressive strength, compressive fatigue strength, surface hardness, water sorption and solubility of eight different posterior restorative composite resins. Eight composite resins were tested for their strength of the compressive and compressive fatigue with prepared two different types of specimens (I and T-type) using a Instron universal testing machine (model No. 1332). The hardness was measured with a Knoop hardness tester (MVH-2, Tokyo) for each cylindrical specimen, 7mm in diameter and 5mm thick. The water sorption and solubility were evaluated with the prepared composite resin disks, 20mm in diameter and 1mm thick. The results were as follows: 1. The compressive strength, compressive fatigue strength and hardness were noticed to be Increased by increasing the volume content of filler. 2. The compressive strength was appeared to be independent on the type of specimen, but the compressive fatigue strength was found to be greatly influenced by the type of specimens. 3. The composite resins having higher compressive strength had also higher compressive fatigue limits. 4. The compressive fatigue limits at $10^5$ stress cycles were about 50-80% of the compressive strength and were showen to be dependent on the materials and type of specimens. 5. The larger the filler particle size was, the lower was the water sorption. And the water sorption of BIS-GMA resin was higher than that of urethane resin. 6. The visible light-cured composite resin had a higher value of solubility than the chemically- cured composite resin. And the solubility tended to decrease by increasing the volume content of filler.

  • PDF

AN IN-VITRO WEAR STUDY OF CEROMER AND HUMAN ENAMEL (Ceromer (Targis)에 의한 법랑질 마모에 관한 연구)

  • Kim, Jeong-Min;Lee, Sun-Hyung;Yang, Jae-Ho
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.38 no.4
    • /
    • pp.438-445
    • /
    • 2000
  • The ideal restorative material should mimic the properties of the tissues it replaces. Dental composite resins have been used widely as restorative materials due to its advantages such as excellent esthetics and ease of manipulation. But inadequate wear resistance has been a major factor limiting the use of composite restorative materials. Improved manufacturing techniques have allowed the development of hybrid composites, with a greater percentage volume filler loading, which have improved physical and mechanical properties. However they are lacking in the study of wear resistance. The purpose of this study was to evaluate the wear of human enamel against ceromer by the use of a pin-on-disk type wear testers. Discs of ceromer(Targis ; lvoclar Vivadent, Amherst. NY) and discs of type III gold alloy as a control were used f9r test specimens. Intact cusp of premolar and molar were used for enamel specimens. The wear of enamel was determined by weigh-ing the cusp before and after each test, and the weight converted to volumes by average densi-ty of enamel. Surface profilometer was used to quantify wear of the ceromer and gold specimens. Vicker's hardness tester was used to evaluate the surface hardness of test specimens. The SEM was used to evaluate the wear surfaces The results were as follows; 1. Ceromer produced less enamel wear than gold(p<0.05) 2. The wear volume of ceromer was greater than that of gold(p<0.01) 3. The hardess of ceromer was lower than that of gold, but there was no correlation between the hardness and wear of the ceromer and gold. 4. SEM analysis revealed that there were many voids and microcracks in the wear tract of ceromer In gold group, many minute V-shaped grooves were examined.

  • PDF