• Title/Summary/Keyword: low-noise field measurement

Search Result 59, Processing Time 0.026 seconds

Improvements of Reverberation Chamber's Performance by using Active Noise Control (능동 소음제어를 이용한 잔향실의 저주파 특성 개선 가능성)

  • K. Kim, Young-Key;Oh, Shi-Whan;Moon, Sang-Mu;Im, Jong-Min;Kim, Hong-Bae
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2004.11a
    • /
    • pp.857-861
    • /
    • 2004
  • An active method that improves low frequency characteristics of a reverberation chamber has been proposed. Spatial uniformity of sound pressure at low frequency has been increased by applying active noise control system. The system acts as frequency selective damping materials, which decreases resonance at low frequency and leave high frequency sound field as it is. Linearity of the chamber, which is essential for sound power measurement in the chamber, is guaranteed since fixed control logic has been adopted. Simple application and tests have been done in a small sized rectangular reverberation chamber which has 400Hz cutoff, Loud speakers were used to simulate a noise source and to construct an active noise control system. The spatial distribution of a sound field at 250Hz, 315Hz and 400Hz bands has been measured before and after control. The standard deviation of sound field has been decreased from 3.4dB to 2.5dB. The results show the possibility of active control system as a sound diffuser.

  • PDF

Measurement method for valve noise (밸브의 소음 측정 방법)

  • Lee, Y. B.;Yoon, B. R.;Kwon, H. S.;Park, K. A.;Yoo, S. H.
    • 유체기계공업학회:학술대회논문집
    • /
    • 2001.11a
    • /
    • pp.433-438
    • /
    • 2001
  • Noise is one of the major environmental problems in human life. To reduce the noise emitted from the control valve it is necessary to develop the measurement method, measurement system, analysis method applicable to the field. In this study IEC and ISO standards were investigated and measurement method for the valve noise was proposed. Noise from the valve was measured in the reverberation room and sound power level was calculated. The sound power level increased as the flow rate and pressure difference increased. The noise characteristics are useful to predict valve noise for given conditions, to compare the performance of different valves and to develope low-noise valves.

  • PDF

Development of a HTS SQUID gradiometer system for the measurement of very weak magnetic field in an unshielded environment (비자기차폐환경에서 미세 자기장 측정을 위한 고온초전도 gradiometer 시스템의 개발)

  • Kim, In-Seon;Kim, Jin-Mok;Park, Yong-Ki
    • 한국초전도학회:학술대회논문집
    • /
    • v.10
    • /
    • pp.151-154
    • /
    • 2000
  • We have developed a YBCO SQUID gradiometer system for the measurement of a very weak magnetic field in an unshielded environment. The system consists of a SQUID gradiometer sensor, low noise pre-amp, and FLL(fluxlocked loop) control electronics. The gradiometer sensors have been fabricated on STO bicrystal substrates, and exhibit a magnetic noise of 300 fT/${\surd}$ Hz/cm at 100 Hz. The overall magnetic field noise of the SQUID gradiometer system was about 10 pT/${\surd}$ Hz/cm at 10 Hz without any magnetic shield. The system demonstrated a high stability for a long time, and real-time measurement resolution ${\le}$ 100 pT/cm in the unshielded environments.

  • PDF

Investigation of the heavy-weight floor impact sound field in a testing building with bearing wall structure (벽식구조 표준시험동에서 중량충격음장에 관한 연구)

  • Yoo, Seung-Yup;Lee, Sin-Young;Jeon, Jin-Yong
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2007.05a
    • /
    • pp.969-973
    • /
    • 2007
  • The heavy-weight floor impact sound field of the receiving room in a testing building with bearing wall structure was investigated using bang machine and impact ball. The sound field was investigated through the impact sound pressure level distribution by the field measurement and computational analysis. Predicted sound field using the computational analysis agree with measurement result in the low frequency band. Result shows that standard deviations of the single number rating value are about 2dB in each impact source. Particularly, impact sound pressure level at 120cm height in 63Hz octave band was 5dB lower than spatial averaging value. It was found that receiving positions in the ministry of construction and transportation notice should be reconsidered.

  • PDF

Experimental investigation into infrasound and low-frequency noise radiation characteristics from large wind turbines (중대형 풍력터빈의 저주파 및 초저주파 소음 방사 특성에 대한 실험적 고찰)

  • Lee, Seung-Yub;Cheong, Cheol-Ung;Shin, Su-Hyun;Jung, Sung-Soo;Cheung, Wan-Sup
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2007.11a
    • /
    • pp.1482-1489
    • /
    • 2007
  • In this paper, characteristics of infrasound and low-frequency noise emission from large modern wind turbines are experimentally investigated. The sound measurement procedures of IEC 61400-11 and ISO 7196 are utilized to field test and evaluation of noise emission from each of 1.5 MW and 660 kW wind turbines using the stall regulation and the pitch control for the power regulation, respectively. It was found that the G-weighted SPLs of low-frequency noise including infrasound shows positive correlation with the wind speeds, irrespective of methods of power regulation. This highlights the potential complaint of local community against the infrasound and low-frequency noise of wind turbines. The comparison of measured data with the existing hearing thresholds and criteria curves shows that it is highly probable that the low-frequency noise from the 1.5 MW and 660 kW wind turbines in the frequency range over 30 Hz leads to the psychological complaint of ordinary adults, and that the infrasound in the frequency range from 5 Hz to 8 Hz causes the complaint by rattling the house fitting such as doors and windows.

  • PDF

A Study on the reduction effect of noise and vibraton using auger-drilled piling (매입 말뚝공법의 항타공해 저감효과)

  • 박찬국;박용부
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 1995.10a
    • /
    • pp.1031-1040
    • /
    • 1995
  • Recently, a more strict regulation has become effective on ground vibration and noise induced by construction activities. Consequently the demand for the most widely used method of installing precast piles, i.e. driven piles, is declining. At the same time the demand for low noise and low vibration piling method increased sharply. Currently there are several different low noise and low vibration methods of installing precast piles, mostly preboring method. However, the actual level of ground vibration and noise of these method of construction has not yet been clearly understood. In this paper, through field measurement, suggestion has been made to meet the requirements of the revised regulation.

  • PDF

Interior noise characteristic and contribution analysis for rolling stocks (전동차 실내소음특성 및 기여도 분석)

  • 정승원;이용관;박석태;김경환
    • Proceedings of the KSR Conference
    • /
    • 1999.05a
    • /
    • pp.200-207
    • /
    • 1999
  • The purpose of this research is to setup the design procedure of low noise rolling stocks. Noise sources are identified at a field test, and the contribution of noise sources to each part of car interior is ensured by sound intensity measurement technique. Added material to each section of the carbody makes it possible to identify absorption or reflection performance of each part to the anterior random noise. Such experimental tests to the exterior noise intruding through the floor represent that the best countermeasure on the floor is to implement reflecting material which can properly interfere noise. Design procedure of low noise rolling stocks is set through several experiments.

  • PDF

FEASIBILITY STUDY OF SOUND POWER BASED ACTIVE NOISE CONTROL STRATEGIES FOR GLOBAL NOISE REDUCTION

  • Kang, Seong-Woo;Kim, Yang-Hann
    • Proceedings of the Acoustical Society of Korea Conference
    • /
    • 1994.06a
    • /
    • pp.785-790
    • /
    • 1994
  • The active noise control which regards the acoustic power as a target function to be minimized, is analyzed to test its feasibility of which simplifies the measurement system compared with the global acoustic energy based active noise control system. In fact, it is found that the acoustic power based active noise control strategy is equally likely as good as the global acoustic energy based active noise control method if the acoustic field of interest is diffusive or very low model density one. In the intermediate model density field, we also demonstrate that the power based control gives the similar results as the energy based control in terms of global sound energy reduction for the lightly damped enclosure which might be most important system in practical application. From all the theoretical and power based control strategy is dependent on the characteristics of the acoustic field to be controlled; i.e., the model density distribution, the degree of reverberation, and on the strength of modal interaction of the control source with the primary source; i.e., the location of control source.

  • PDF

So, You Need Reliable Magnetic Measurements You Can Use With Confidence? How the Magnetic Measurement Capabilities at NPL Can Help

  • Hall, Michael;Harmon, Stuart;Thomas, Owen
    • Journal of Magnetics
    • /
    • v.18 no.3
    • /
    • pp.339-341
    • /
    • 2013
  • The magnetic field standards, facilities and capabilities available at NPL for the calibration of magnetometers and gradiometers and the measurement of the magnetic properties of materials will be introduced. The details of the low magnetic field facility will be explained and the capabilities this facility enables for the characterisation and calibration of ultra-sensitive room temperature magnetic sensors will be presented. Building on core material capabilities that are compliant with the IEC 60404 series of written standards, the example of a standard permeameter that has been modified for the measurement of strips for real world conditions is discussed. This was incorporated into a stress machine to measure the DC properties of the soft magnetic materials used by the partners of a collaborative industry led R&D project at stress levels of up to 700 MPa. The results for three materials are presented and the changes in the properties with applied stress compared to establish which material exhibits favourable properties.

Effects of the Facade of the Buildings on the Sound Characteristics in an Apartment Complex (공동주택 입면 변화에 따른 단지 내 소음특성)

  • Kim, Yong-Hee;Lee, Pyoung-Jik;Jeon, Jin-Yong;Lee, Byung-Kwon
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2005.11a
    • /
    • pp.367-370
    • /
    • 2005
  • This paper investigated the sound characteristics in an apartment complex. The field measurement was conducted in order to examine the acoustical characteristics of the apartment complex in situ. As a result, it shows that there are around 3 sec. reverberation time and the additional sound reinforcements at the area of high height due to the surrounded buildings. Thus, 1:50 Scale model measurement and Raynoise computer simulation were carried out with insertion of the parapet and the canopy on the balcony. In case of a single building, the parapet was effective to reduce noise level at low floor levels, and the canopy was effective to reduce noise level at high floor levels. But it also shows that both the parapet and the canopy were not effective to reduce noise level at middle floor levels. In case of an apartment complex, the canopy was less effective to reduce noise level at each floor in comparison with case of the single building.

  • PDF