• 제목/요약/키워드: low-mass

검색결과 4,473건 처리시간 0.032초

Pressure Effects o]n Critical Heat Flux under Low Pressure and Low Flow Conditions

  • Kim, Hong-Chae;Park, Jae-Wook;Baek, Won-Pil;Chang, Soon-Heung
    • 한국원자력학회:학술대회논문집
    • /
    • 한국원자력학회 1996년도 춘계학술발표회논문집(2)
    • /
    • pp.82-87
    • /
    • 1996
  • To find the effects of pressure on critical heat flux (CHF) for the conditions of low pressures (especially up to 10 bar) and low mass flux (~300 kg/$m^2$s), a series of experiments have been accomplished by using uniformly heated Inconel-625 tube. The experimental ranges are as follows: pressure (from 1.2 to 8 bar). mass velocities (from 100 to 250 kg/$m^2$s) and the inlet subcooling ($\Delta$h$_{i}$ = 350 kJ/kg). According to the experimental data, it is found that the CHF is nearly independent of the pressure and increases with mass flux. From the results of the CHF correlation assessment for this experimental data, we could find somewhat different tendency of CHF behavior from every other CHF prediction correlation and table.ation and table.

  • PDF

Some Aspects of Experimental in-Tube Evaporation

  • Ha, Sam-Chul
    • Journal of Mechanical Science and Technology
    • /
    • 제14권5호
    • /
    • pp.537-546
    • /
    • 2000
  • The heat transfer characteristics of refrigerant-oil mixture for horizontal in-tube evaporator have been investigated experimentally. A smooth copper tube and a micro-fin tube with nominal 9.5 mm outer diameter and 1500 mm length were tested. For the pure refrigerant flow, the dependence of the axial heat transfer coefficient on quality was weak in the smooth tube, but in the micro-fin tube, the coefficients were 3 to 10 times greater as quality increases. Oil addition to pure refrigerant in the smooth tube altered the flow pattern dramatically at low mass fluxes, with a resultant enhancement of the wetting area by vigorous foaming. The heat transfer coefficients of the mixture for low and medium qualities were increased at low mass fluxes. In the micro-fin tube, however, the addition of oil deteriorates the local heat transfer performance for most of the quality range, except for low quality. The micro-fin tube consequently loses its advantage of high heat transfer performance for an oil fraction of 5%. Results are presented as plots of local heat transfer coefficient versus quality.

  • PDF

Body Mass Index, Body Weight Perception, and Depressed Mood in Korean Adolescents

  • Lim, Yooli;Kim, Bongseog
    • Journal of the Korean Academy of Child and Adolescent Psychiatry
    • /
    • 제28권1호
    • /
    • pp.31-37
    • /
    • 2017
  • Objectives: We examined the relationships between the body mass index, body weight perception, and depressed mood in a nationally representative sample of Korean adolescents. Methods: We analyzed the data from the 2013 Korean Youth Risk Behavior Web-based Survey and evaluated the relationships between the body mass index, body weight perception, and depressed mood by gender (36655 boys and 35780 girls). Results: For boys, a low body mass index and perceiving oneself as underweight were related to depressed mood. For girls, both low and high body mass indices were negatively related to depressed mood. In addition, self-perceptions of being underweight or overweight were positively related to depressed mood. Body weight perception was not a significant mediator in the relationship between body mass index and depressed mood. Conclusion: These results suggest that both body mass index and body weight perception significantly contribute to Korean adolescents' depressed mood. Thus, research and clinical attention needs to be given to underweight as well as overweight adolescents, because those who perceive their weight as not normal are at risk for depression.

동위원소희석 유도결합플라스마질량분석법에 의한 저 합금강 표준시료중의 Ni, Cr, Mo의 분석 (Determination of Ni, Cr, Mo in Low Alloy Steel Reference Materials by Isotope Dilution Inductively Coupled Plasma Mass Spectrometry)

  • 서정기;우진춘;민형식;임명철
    • 분석과학
    • /
    • 제16권1호
    • /
    • pp.82-89
    • /
    • 2003
  • Isotope dilution mass spectrometry (IDMS) was applied to the determination of Ni, Cr, Mo in low alloy steel reference materials. The Mo isotope ratio measurement was performed by dynamic reaction cell inductively coupled plasma mass spectrometry (DRC-ICP/MS) using ammonia as a reaction cell gas. In the case of Ni and Cr measurement, all data were obtained at medium resolution mode (m/${\Delta}m=3000$) of double focusing sector field high resolution inductively coupled plasma mass spectrometry (HR-ICP/MS). For the method validation of the technique was assessed using the certified reference materials such as NIST SRM 361, NIST SRM 362, NIST SRM 363, NIST SRM 364, NIST SRM 36b. This method was applied to the determination of Ni, Cr and Mo in low alloy steel sample (CCQM-P25) provided by NMIJ for international comparison study.

Critical Heat Flux for Low Flow in Vertical Annulus under Various Pressure Conditions

  • Chun, Se-Young;Jun, Hyung-Gil;Chung, Heung-June;Moon, Sang-Ki;Chung, Moon-Ki
    • 한국원자력학회:학술대회논문집
    • /
    • 한국원자력학회 1997년도 춘계학술발표회논문집(1)
    • /
    • pp.386-391
    • /
    • 1997
  • It is important to understand correctly a CHF under low flow condition for the purpose of enhancing the reactor safety and performance in the LWRs. The CHF experiments have been carried out for an internally heated vertical annulus in RCS loop facility. The experimental conditions cover ranges of pressure from 1.82 to 12.08 MPa, mass flux from 300 to 550kg/$m^2$. s and inlet subcooling of 210kJ/kg. The CHF data decrease with increasing pressure at high value of mass flux. For mass flux of about 300kg/$m^2$. s, the CHF rue little influenced by pressure. The CHF data are correlated well by using the dimensionless heat flux and dimensionless mass flux for a fixed inlet subcooling except the data group of 12.08 MPa. It seems that the Doerffer correlation and Katto correlation overestimate the CHF for low pressure and lower value of mass flux within this experimental ranges. The Bowling correlation gives a better prediction than the other two correlations.

  • PDF

The Evolution of the Mass-Metallicity Relation at 0.20 < z < 0.35

  • Chung, Jiwon;Rey, Soo-Chang;Sung, Eon-Chang
    • Journal of Astronomy and Space Sciences
    • /
    • 제30권1호
    • /
    • pp.59-67
    • /
    • 2013
  • We present a spectroscopic study of 343 blue compact galaxies (BCGs) at 0.20 < z < 0.35 from the Sloan Digital Sky Survey (SDSS) DR7 data. We derive gas phase oxygen abundance using the empirical and direct method. Stellar masses of galaxies are derived from the STARLIGHT code. We also derive star formation rates of galaxies based on $H{\alpha}$ emission line from the SDSS as well as far-ultraviolet (FUV) flux from the Galaxy Evolution Explorer GR6 data. Evolution of the luminosity-metallicity and mass-metallicity (M-Z) relations with redshift is observed. At a given luminosity and mass, galaxies at higher redshifts appear to be biased to low metallicities relative to the lower redshift counterparts. Furthermore, low mass galaxies show higher specific star formation rates (SSFRs) than more massive ones and galaxies at higher redshifts are biased to higher SSFRs compared to the lower redshift sample. By visual inspection of the SDSS images, we classify galaxy morphology into disturbed or undisturbed. In the M-Z relation, we find a hint that morphologically disturbed BCGs appear to exhibit low metallicities and high SSFRs compared to undisturbed counterparts. We suggest that our results support downsizing galaxy formation scenario and star formation histories of BCGs are closely related with their morphologies.

성인의 악하부에 발생한 낭성 림프관종 (Cystic lymphangioma in the submandibular triangle in the adult)

  • 김은경;한원정;김상준
    • Imaging Science in Dentistry
    • /
    • 제31권3호
    • /
    • pp.175-179
    • /
    • 2001
  • Cystic lymphangioma is an uncommon benign developmental tumor of the lymphatic system, seen rarely in adults. A 23-year-old man visited DKUDH complaining of the painless swelling in the right submandibular area. It was reported that swelling had increased since 5 months ago. Clinically, fltriangle uctuant and mobile mass was palpated at the right submandibular area. CT scan showed a large, well-defined, homogenous low density mass, measuring 5.0 × 2.5 × 4.0 cm. T1W MRI scan demonstrated a large, multiseptated homogenous low signal mass with septum and rim enhancement. Proton-density and T2W MRI scan showed mass of high signal intensity. MRI scan was able to delineate better the enhanced multi septation and extent of the lesion. Histopathologically, a lobulated cystic mass lined by a layer of flattened endothelium was observed.

  • PDF

수직흡수기의 열 및 물질전달 촉진 (Enhancement of Heat and Mass Transfer for a Vertical Type Absorber)

  • 권오경
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제22권3호
    • /
    • pp.362-370
    • /
    • 1998
  • Absorption systems require a heat source for working but they have a great merit in that relatively low-temperature and low-quality types of thermal energy such as solar heat and exhaust heat can be effectively utilized as heat source. However details research related to absorbers which have a great effect on performances has been rarely done and thus there has been a strong hope for positive developments to improve their efficiencies. This paper describes absorption experiments made with different inside tube diameters and shapes. The purpose of this study is to acquire basic knowledge about heat and mass transfer in a falling film type absorber with vertical inner tubes. Heat and mass transfer were measured for water vapor absorption into a water/LiBr solution flowing down an absorber of vertical inner tubes. As a result absorption acceleration tube compares bare tube and heat transfer improved by order of insert spring tube corrugated tube grooved tube. And the acceleration that is good provided in inserting spring tube for both sides of heat and mass transfer.

  • PDF

물유동층 열교환기의 열회수성능 연구 (A Study on the Heat Recovery Performance of Water Fludized-Bed Heat Exchanger)

  • 김한덕;박상일;이세균
    • 설비공학논문집
    • /
    • 제15권8호
    • /
    • pp.690-696
    • /
    • 2003
  • This paper presents the heat recovery performance of water fluidized-bed heat exchanger. Temperature and humidity ratio of waste gas are considered as important parameters in this study. Therefore, the heat recovery rate through water fluidized-bed heat exchanger for exhaust gases with various temperatures and humidity ratios can be estimated from the results of this study. Mass flow ratio (the ratio of mass flow rate of water to that of gas) and temperature of inlet water are also considered as important operating variables. Increase of heat recovery rate can be obtained through either high mass flow ratio or low temperature of inlet water with resultant low recovered temperature. The heat recovery performance with the mass flow ratio of about up to 10 has been investigated. The effect of number of stages of water fluidized-bed on the heat recovery performance has been also examined in this study.

1996년 제주도에 나타난 대형저서동물의 대량폐사: 물리해양학적 요인의 역할 (The 1996 Mass Mortality of Macrobenthic Animals in Cheju Island: A Possible Role of Physical Oceanographic Factor)

  • 서해립;조양기;서호영;김대환
    • 환경생물
    • /
    • 제17권2호
    • /
    • pp.175-182
    • /
    • 1999
  • 1996년 여름 제주도 서쪽 해안에서 전에 볼 수 없을 정도로 유용 대형저서동물이 대량으로 죽어, 전복, 오분자기, 소라, 해삼, 말똥성게에 큰 피해를 주었다. 제주도 해안에서 식물플랑크톤 대발생은 없었고, 대량폐사가 일어나기 전에 해안에서 표층 저염수가 나타났기 때문에 저염분 스트레스가 대량폐사에 결정적인 영향을 미쳤을 것으로 여겨진다. 같은 기간 관측된 강수량이 적어, 강수량으로 저염화를 설명하지 못한다. 국립수산진흥원(1997)이 관측한 자료는 1996년 8월 제주도와 중국 사이 해역에 표충 저염수가 나타난 것을 확실히 보여준다. 제주도 서쪽 해안에 나타난 표층 저염수는 다량으로 유출된 강물이 그 기원일 가능성이 가장 높다. 해류와 양자강에서 제주도까지 거리등도 표층 저염수가 양자강에서 방류된 강물에서 기원한 것이라는 가설을 지지한다.

  • PDF