• Title/Summary/Keyword: low-loss

Search Result 5,103, Processing Time 0.035 seconds

An Effective Training Pattern Processing Method for ATM Connection Admission Control Using the Neural Network (신경회로망을 이용한 ATM 연결 수락 제어를 위한 효율적인 학습패턴 처리 기법)

  • Kwon, Oh-Jun;Jeon, Hyoung-Goo;Kwon, Soon-Kak;Kim, Tai-Suk;Lee, Jeong-Bae
    • The KIPS Transactions:PartB
    • /
    • v.9B no.2
    • /
    • pp.173-180
    • /
    • 2002
  • The virtual cell loss rate was introduced for the training pattern of the neural network in the VOB(Virtual Output Buffer) model. The VOB model shows that the neural network can find the connection admission boundary without the real cell loss rate. But the VOB model tends to overestimate the cell loss rate, so the utilization of network is low. In this paper, we uses the reference curve of the cell loss rate, which contains the information about the cell loss rate at the connection admission boundary. We process the patterns of the virtual cell loss rate using the reference curve, We performed the simulation with two major ATM traffic classes. One is On-Off traffic class that has the traffic characteristic of LAN data and other is Auto-Regressive traffic class that has the traffic characteristic of a video image communication.

The Effect of an Energy Restriction Program on the Weight Loss and the Change of Biochemical nutritional Status in Obese Women

  • Son, Sook-Mee;Kim, Hee-Jun;Lee, Yoon-Na;Lee, Hong-Sup
    • Korean Journal of Community Nutrition
    • /
    • v.2 no.5
    • /
    • pp.695-700
    • /
    • 1997
  • This study was conducted to investigate the effect of an energy restriction program on the weight loss and changes of the biochemical nutritional status for 35 obese women. The energy restriction program took place over a 3-week period that was devided into two parts. The first part consisted of 750-800kcal diet and the second part of 800-1000kcal. Subjects were provided a low energy formula and a menu for the recommended diet. Anthropometric and biochemical measurement before and after the energy restriction program were estimated. Mean weight loss was 3.0kg, accordingly the obestiy rate was lowered from 40.2 to 34.4, BMI from 29.2 to 28.9 and fat weight from 23.3kg to 21.0kg( <0.01. <0.05). Waist circumference loss was most prominent(4.4%) compared to triceps(21% loss)and hip circumference(2.2%loss). Mean RBC count, hemoglobin and hematocrit were significantly lowered( <0.01) but they were in the normal range. Systolic blood pressure was significantly decreased from 124.1mmHg to 113.1mmHg . Mean SGOT and SGPT were lowered from 29.3u/L to 20.0u/L and from 28.7u/L to 16.6u/L, respectively. It seems that the 3 weeks of energy restriction program used in this study was effective in improving anthropometric measurements without producing deficiency of iron or other susceptible nutrients.(Korean J community Nutrition 2(5) : 695-700,1997)

  • PDF

Studies on the Physical Properties of Synthetic Rubber Blends Containing Rein-forcing Fillers (보강성 충전제를 함유한 합성고무 블렌드의 물리적 특성에 관한 연구)

  • Go, Jin-Hwan;Lee, Seog
    • Elastomers and Composites
    • /
    • v.33 no.4
    • /
    • pp.231-237
    • /
    • 1998
  • In order to investigate the physical properties of rubber blend compound, this experiment was carried out on the cure rate, loss tangent, reinforcement and abrasion properties of S-SBR (solution styrene-butadiene rubber) blends containing silane coupled silica and E-SBR (emulsion styrene-butadiene rubber) blends containing carbon black as a model compound. E-SBR blend showed the highest total bound rubber(TBR), while S-SBR blends showed constant TBR level regardless of rubber type. Rapid cure rate was achieved when the styrene and vinyl content of rubber microstructure decreased and TBR content of rubber compounds increased. The modulus as the index of rubber reinforcement showed the linear relation with TBR content. The large amount of PICO loss was observed when the styrene and vinyl content of rubber microstructure increased, while the small amount of PICO loss was observed when the ratio of bu-tadiene increased in the S-SBR blends with silane copuled silica. The high loss tangent at $0^{\circ}C$, the low loss tangent at $60^{\circ}C$, and the large difference of loss tangent were shown in the S-SBR blends with high styrene content compared to E-SBR blend.

  • PDF

A study on the friction head loss in flat aluminum micro multi tubes with nonazeotropic refrigerant mixtures R-410A (비공비 혼합냉매 R-410A를 적용한 납작한 알루미늄 마이크로 멀티 튜브에서의 마찰손실에 관한 연구)

  • Lee, Jeong-Kun;Min, Kyung-Ho
    • Design & Manufacturing
    • /
    • v.13 no.2
    • /
    • pp.37-43
    • /
    • 2019
  • This study conducted a research as to condensation heat transfer friction loss headby using three types of flat micro multi-channel tubes with different processing of micro-fin and number of channels inside the pipes and different sizes of appearances. In addition, identical studies were conducted by using smoothing circular tubes with 5mm external diameter to study heat enhancement factor and pressure drop penalty factor. 1) The friction head loss showed an increase as the vapor quality and mass flux increased. In case of saturation temperature, it shows an increase as it gets lower. These factors are the reason occurring as the lower the saturation temperature is, the higher the density of refrigerant vapor gets. The influence of heat flux is similar as the dryness is low, but as it gets higher, it lowers in heat flux, and as the high temperature of high heat flux, it is a factor that occurs as the density gets lower. 2) RMS error of the in case of friction head loss, it showed to be predicted as 0.45~0.67 by Chisholm, Friedel, Lockhart and Martinelli. 3) As forfriction head loss penalty factor, the smaller the aspect ratio is, the larger the penalty factor gets, and as for the effect of micro-fin, the penalty factor increased because it decreases to the gas fluid the way groove for the refrigerant's flow.

Comparison for Loss Rate of Low Concentration Nitrous Oxide in Tedlar Bag and Aluminium-Polyester Bag (테들러백과 알루미늄-폴리에스터백에 보관된 저농도 아산화질소의 유실율 비교)

  • Lee, Woo Chan;Park, Sung Bin;Ko, Young Hwan;Hyun, Seung Min;Yoon, Kyoon Duk
    • Journal of Climate Change Research
    • /
    • v.8 no.1
    • /
    • pp.31-39
    • /
    • 2017
  • The emission quantity of nitrous oxide is second largest among non-$CO_2$ greenhouse gas in Korea. In this study, we investigated loss rate of nitrous oxide which was filled in PVF and Al-PE bag as time goes on. Concentrations of tested samples were about 25 ppmv, 50 ppmv, 75 ppmv prepared by standard reference gas. In case of all experiments, loss rate of PVF bag was higher than Al-PE bag. After 18 days, loss rate of PVF bag was from 29.7% to 38.6% while Al-PE bag was from 21.7% to 23.7%. Especially the differential growed bigger when initial concentration of $N_2O$ in PVF bag was lower. And we also studied the effect of cock opening/closing procedures on loss rate. Prepared samples in experimental group were analyzed several times for 20 days and samples in control group were analysed only 1 time after 20 days. The experimental results showed that cock opening/closing procedures appeared to have little impact on loss rate.

The Characteristics Analysis of Low Profile Meander 2-Layer Monopole Antenna (소형 미앤더 2-층 모노폴 안테나의 특성분석)

  • Jang, Yong-Woong;Lee, Sang-Woo;Shin, Ho-Sub
    • Journal of Broadcast Engineering
    • /
    • v.19 no.6
    • /
    • pp.934-941
    • /
    • 2014
  • In this paper, we present a low profile 2-layered meander built-in monopole antenna for portable RFID reader using FDTD(Finite Difference Time Domain) method. The input impedance, return loss, and VSWR in the frequency domain are calculated by Fourier transforming the time domain results. The double meander 2-layer structure is used to enhance the impedance matching and increase the antenna gain. The measured bandwidth of the antenna is 0.895 GHz ~ 0.930 GHz for a S11 of less than -10dB. The measured peak gain of proposed low profile RFID built-in antenna is 2.3 dBi. And the proposed built-in antenna for portable RFID reader can offers relatively wide-bandwidth and high-gain characteristics, in respectively. Experimental data for the return loss and the gain of the antenna are also presented, and they are relatively in good agreement with the FDTD results. This antenna can be also applied to mobile communication field, energy fields, RFID, and home-network operations, broadcasting, and other low profile mobile systems.

A case of Bartter syndrome type I with atypical presentations

  • Lee, Eun-Hye;Heo, Ju-Sun;Lee, Hyun-Kyung;Han, Kyung-Hee;Kang, Hee-Gyung;Ha, Il-Soo;Choi, Yong;Cheong, Hae-Il
    • Clinical and Experimental Pediatrics
    • /
    • v.53 no.8
    • /
    • pp.809-813
    • /
    • 2010
  • Bartter syndrome (BS) is an autosomal recessively inherited rare renal tubular disorder characterized by hypokalemic metabolic alkalosis and hyperreninemic hyperaldosteronism with normal to low blood pressure due to a renal loss of sodium. Genetically, BS is classified into 5 subtypes according to the underlying genetic defects, and BS is clinically categorized into antenatal BS and classical BS according to onset age. BS type I is caused by loss-of-function mutations in the $SLC12A1$ gene and usually manifests as antenatal BS. This report concerns a male patient with compound heterozygous missense mutations on $SLC12A1$ (p.C436Y and p.L560P) and atypical clinical and laboratory features. The patient had low urinary sodium and chloride levels without definite metabolic alkalosis until the age of 32 months, which led to confusion between BS and nephrogenic diabetes insipidus (NDI). In addition, the clinical onset of the patient was far beyond the neonatal period. Genetic study eventually led to the diagnosis of BS type I. The low urinary sodium and chloride concentrations may be caused by secondary NDI, and the later onset may suggest the existence of a genotype-phenotype correlation. In summary, BS type I may have phenotype variability including low urine sodium and chloride levels and later onset. A definitive diagnosis can be confirmed by genetic testing.

Triple-band Multiplexer for a Low Power Portable Base Station (이동통신 기지국용 삼중대역 멀티플렉서)

  • Seo, Soo-Duk;Cho, Hak-Rea;Yang, Doo-Yeong
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.15 no.12
    • /
    • pp.7309-7316
    • /
    • 2014
  • In this paper, a triple-band multiplexer using a microstrip transmission line was designed and fabricated to make use of a low power portable base station. This multiplexer was used in the triple-band including the cellular, WCDMA and LTE mobile frequency band, and designed to have an insertion loss of 0.8 dB, low SWR of 1.5 in the passband and a band rejection of 15 dB in the stopband. From the measured results obtained by a confidence test for the fabricated multiplexer samples, the maximum insertion loss and SWR of the fabricated multiplexer samples in all passbands of 824-894MHz, 1920-2170 MHz and 2500-2600 MHz were below 0.71 dB and 1.38, and the attenuations in the stopbands were better than 15 dB. Therefore, the triple-band multiplexer has good performance and satisfies the design specifications.

Low Dose Yeast Hydrolysate in Treatment of Obesity and Weight Loss

  • Jung, Eun Young;Lee, Jong Woo;Hong, Yang Hee;Chang, Un Jae;Suh, Hyung Joo
    • Preventive Nutrition and Food Science
    • /
    • v.22 no.1
    • /
    • pp.45-49
    • /
    • 2017
  • The anti-obesity effects of yeast hydrolysate (YH) supplementation (1.0 g/d) have already been demonstrated. We investigated whether a low dose of YH (0.5 g/d, YH-500) also has the anti-obesity effects. Thirty obese women were randomly assigned to the control or YH-500 groups. After 8 weeks, weight and body mass index were significantly reduced by the YH treatment (0.5 g/d) (P<0.05). The YH-500 group lost a significant amount of body fat after the 8-week treatment: fat mass 25.9 kg (baseline) versus 23.8 kg (8th week), P<0.01; fat mass ratio 38.8% (baseline) versus 36.5% (8th week), P<0.05. The YH-500 group showed a significant reduction in calorie intake during the 8-week treatment (P<0.001). The control group wanted to eat much more food (P<0.05) and sometimes thought about eating more often compared with the YH-500 group (P<0.05). Whereas the control group showed a slightly increased sweet preference, the YH-500 group showed a significant reduction in sweet preference (P<0.05). In conclusion, low dose YH supplementation (0.5 g/d) may induce a reductions in weight and body fat in obese women via the reduction of calorie intake.

Implementation of High-Quality Si Integrated Passive Devices using Thick Oxidation/Cu-BCB Process and Their RF Performance (실리콘 산화후막 공정과 Cu-BCB 공정을 이용한 고성능 수동 집적회로의 구현과 성능 측정)

  • 김동욱;정인호
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.15 no.5
    • /
    • pp.509-516
    • /
    • 2004
  • High-performance Si integrated passive process was developed using thick oxidation process and Cu-BCB process. This passive process leads to low-cost and high-quality RF module with a small form factor. The fabricated spiral inductor with 225 um inner diameter and 2.5 turns showed the inductance of 2.7 nH and the quality factor more than 30 in the frequency region of 1 ㎓ and above. Also WLCSP-type integrated passive devices were fabricated using the high-performance spiral inductors. The fabricated low pass filter had a parallel-resonance circuit inside the spiral inductor to suppress 2nd harmonics and showed about 0.5 ㏈ insertion loss at 2.45 ㎓. And also the high/low-pass balun had the insertion loss less than 0.5 ㏈ and the phase difference of 182 degrees at 2.45 ㎓.