• Title/Summary/Keyword: low-k materials

Search Result 8,596, Processing Time 0.043 seconds

Malacological Studies on Parafossarulus manchouricus(Gastropoda: Prosobranchia) in Korea (한국산(韓國産) 왜우렁(Parafossarulus manchouricus)의 패류학적(貝類學的) 연구(硏究))

  • Chung, Pyung-Rim
    • The Korean Journal of Malacology
    • /
    • v.1 no.1
    • /
    • pp.24-50
    • /
    • 1985
  • Five different populations of Parafossarulus manchouricus (Chongpyung, Chinju and Kunsan, Korea; and Japan and Taiwan), a population of Bitbynia (Gabbia) misella (Gongju, Korea) and two different populations of Bithynta tentaculata (Michigan, U.S.A. and Bodensee, Germany) were compared in regard to eff-laying characteristics, morphology, chromosome cytology, natural infections of parasites and ecology of habitats. A satisfactory culture method was devised for laboratory rearing of the snails. Tropical fish food (Terra SML) and powdered green leaves (Ceralife) were used as the main food sources for the snails. Benthic diatoms such as Navicula and Gomphonema from the periphyton were also essential for satisfactory growth, especially for the baby snails. The aquaria were stabilized with small stones from a local stream. Young P. manchouricus snails grew to adult size in about 54 days after hatching. They laid eggs 150-156 days after hatching. The whole cycle (birth to egg-laying) took approximately 5 months. The three species of bithyniid snails are iteroparous and lay eggs once a year. There were no major morphological differences in the shells of genera or subgenera studied here. They did exhibit the following rather minor differences. The shell of Parafossarulus has spirally raised ridges, and its apex is usually eroded; the other two genera lack these characteristics. The shell of B. (Gabbia) misella is small, nor exceeding 7.5 mm in length, while the shells of the other two species are larger, being more than 10 mm in length. Scanning electron microscopy (SEM) of the protoconch of P. manchouricus reveals nearly smooth sculpture with small, low, spiral wrinkles. This sculpture is quite different from that of the Hydrobiidae, a family to which the bithyniids are frequently assigned. Scanning electron microscopy of the radulae of the three bithyniid species showed that their radular morphologies are very similar, but there are some small differences, which may be species-specific. There were some statistical differences in shell heights between the Korean and the other populations of P. manchouricus, and between this species and the other two bithyniids as well. The shell differences between the several populations of Korean P. manchouricus may be related to environment. Edtails of the chromosome cycle of these bithyniid snails are similar to those reported for other snails. No specific differences were observed in the chromosome cycle between the various species and populations of snails employed in this study. Reporred for the first time in molluscs are two darkly stained "nucleolar organizers" during pachyterne stages of meiosis. Two different chromosome numbers were observed in the three bithyniid species: n=17 in B. tentaculata and P. manchouricus, and n=18 in B. (G.) misella. no sex chromosomes or supernumerary chromosomes were seen. There were no morphological differences in karyotypes of three Korean strains of P. manchouricus. The infection rates of cercariae of Clonorchis sinensis in Chinju and Kunsan strains of P. manchouricus were 0.14% and 1.25%, respectively. However, Clonorchis cercariae were found in Chongpyung strain of P. manchouriceu and Gongju strain of B. (G.) misella. The habitats of P. manchouricus around Jinyang Lake were relatively clean without any heavy pollution of aquatic microorganisms and organic materials during the period of this study. The levels of dissolved oxygen (D.O.) and biochemical oxygen demand (B.O.D.) of the water specimens sampled from the study areas ranged from 6.0 to 9.6 ppm and from 0.4 to 1.6 ppm, respectively. Eight metalic constituents from the water samples were also assayed, and all metalic ions detercted were remarkably low below the legal criteria. However, calcium ion in the water samples from the habitats of P. manchouricus was considerably higher than others.

  • PDF

A Study on Personal hygiene of Primary School Students (초등학교 아동의 개인위생에 대한 조사)

  • Kim, Jae-Sam;Nam, Cbul-Hyun;Kang, Hae-Yang
    • Journal of the Korean Society of School Health
    • /
    • v.9 no.1
    • /
    • pp.109-123
    • /
    • 1996
  • The study was designed to gain necessary basic data, in order to grasp the actual condition on personal hygiene of primary school students and to help school health education and child health education data development of parents of students, the survery was carried out through this reporter's interview for mothers who have primary school pupil in KyungBug area during the period of a month from 14 the April to 30 the April 1994. The results of this study can be summarized as follows. 1. As for general characteristics, the percent of answer mothers with 30~34 years 44.9%, and the percent of answer mothers with 35~39 years was 37.6%, 14.6% of answer mother was 40 years and over. The most house types was apartment house, that is 64.8% and independence house was 18.9%, 13.7% of answer mothers was multivalent house residents. As for level of school career, the percent of high school was 64.2% and the percent of university was 20.5%, 10.1% of answer mothers was finishment of middle school. As for religion a lack of religion was 38.4% and a Buddhist was 36.8%, a christian was 13.4%, 10.4% of answer mothers was a catholic. As for jobs, the percent of office was 33.9%, specialist and expert skiller was 17.3%, self-management was 16.0%, fishing and agrarian villiages was 11.6%, public service personnel and shool personnel was 9.1%. As for the number of sons and daughters, the percent of two was 70.5%, the percent of one was 16.0%, and the percent of male students was 54.1%. As for level of economic life middle level was 59.9%. 2. The percentage of washing hand after school hours was 66.8% and not washing hand after school hours was 33.2%. In washing hand after school hours family of independence house, mothers that have schoolcareer of university, female students, three and over of sons and daughters was high individually (p<0.05). 3. As for paring one's nails, once a ten days was 52.9% once a five days was 22.5% once a fifteen days was 19.0%, once a twenty and over was 5.6%. 4. 54.7% of primary school students of answer mother's take a bath once a few days and 31.6% take a bath once a week, 10.1% take a bath once a tendays. 5. The percentage of changing of underwear once a day was 60.9%, once a few days was 37.1%, once a week was 2.0%, as for changing of underwear, sons and daughters that has mothers with 29 years and downward, one number of sons and daughters, females students was high individually (p<0.01). 6. The percentage of haircut once a 20~30 days was 59.9%, once a 31~40 days was 17.9%, once a 40 days and over was 16.6%. As for the percentage of haircut once a 20~30 days apartment house residents, male students was high (p<0.01). 7. The percentage of experience in taking nutrition was 79.8% and the percentage of experience in taking restorative was 72.3%. As for taking nutrition, apartment house residents, one number of sons and daughters, male students was high individually (p<0.01). As for taking restorative apartment house residents, on number of sons and daughters, male students was high individually (p<0.05). 8. The percentage of habit of unbalanced diet was 44.0%, sons and daughters that have mother with 40 years and over apartment house residents, male students, one number of sons and daughters was high indivdually (p<0.05). 9. As for hygiene condition of sons and daughters, the percentage of good state of health was 65.2%, middle state of health was 3.5% bad state of health was 11.4%. In good state of health sons and daughters that have mothers with 29 years and downward, multivalent house residents, three numbers of sons and daughters, female students, high birth was high individually. 10. As for fattness of sons and daughters, existence was 18.2%. No existence was 81.8%. in existence sons and daughters who have mothers with 40 years and downward, independence house resident, special job and expert skill job, three and over number of sons and daughters, female students, low birth was high individually. 11. As for use aspect of medical facilities of sons and daughters, hospital doctors was 53.1%, drugstore was 42.3%, chinese medicine hospitals or health organization was 4.6%. In usage of drugstore, sons and daughters of mothers with 29 years, 40 years and over was 55.6%, 61.4% individully, inusage of hospital doctors 30~34 years, 34~39 tears was 64.5%, 49.1% individully (p<0.01), apartment house residents, one or two numbers of sons and daughters, male students was high individually. In the percentage of using drugstore, school career of middle school and downward, in occupation, three and over numbers of sons and daughters, low birth was high individually (p<0.05). According to the results mentioned above. An actual condition and a related matters on personal hygiene of primary school students must be used as the basis data of a health education program and a health data of a health education program and a health data related, a teaching materials development and must be helped to the health life education of parents of students and childs.

  • PDF

The Analysis of Radiation Exposure of Hospital Radiation Workers (병원 방사선 작업 종사자의 방사선 피폭 분석 현황)

  • Jeong Tae Sik;Shin Byung Chul;Moon Chang Woo;Cho Yeong Duk;Lee Yong Hwan;Yum Ha Yong
    • Radiation Oncology Journal
    • /
    • v.18 no.2
    • /
    • pp.157-166
    • /
    • 2000
  • Purpose : This investigation was peformed in order to improve the health care of radiation workers, to predict a risk, to minimize the radiation exposure hazard to them and for them to realize radiation exposure danger when they work in radiation area in hospital. Methods and Materials : The documentations checked regularly for personal radiation exposure in four university hospitals in Pusan city in Korea between January 1, 1993 and December 31, 1997 were analyzed. There were 458 persons in this documented but 111 persons who worked less then one year were excluded and only 347 persons were included in this study. Results : The average of yearly radiation exposure of 347 persons was 1.52$\pm$1.35 mSv. Though it was less than 50mSv, the limitaion of radiation in law but 125 (36%) people received higher radiation exposure than non-radiation workers. Radiation workers under 30 year old have received radiation exposure of mean 1.87$\pm$1.01 mSv/year, mean 1.22$\pm$0.69 mSv between 31 and 40 year old and mean 0.97$\pm$0.43 mSv/year over 41year old (p<0.001). Men received mean 1.67$\pm$1.54 mSv/year were higher than women who received mean 1.13$\pm$0.61 mSv/year (p<0.01). Radiation exposure in the department of nuclear modicine department in spite of low energy sources is higher than other departments that use radiations in hospital (p<0.05). And the workers who received mean 3.59$\pm$1.81 msv/year in parts of management of radiation sources and injection of sources to patient receive high radiation exposure in nuclear medicine department (p<0.01). In department of diagnostic radiology high radiation exposure is in barium enema rooms where workers received mean 3.74$\pm$1.74 mSv/year and other parts where they all use fluoroscopy such as angiography room of mean 1.17$\pm$0.35 mSv/year and upper gastrointestinal room of mean 1.74$\pm$1.34 mSv/year represented higher radiation exposure than average radiation exposure in diagnostic radiology (p<0.01). Doctors and radiation technologists received higher radiation exposure of each mean 1.75$\pm$1.17 mSv/year and mean 1.50$\pm$1.39 mSv/year than other people who work in radiation area in hospital (p<0.05). Especially young doctors and technologists have the high opportunity to receive higher radiation exposure. Conclusions : The training and education of radiation workers for radiation exposure risks are important and it is necessary to rotate worker in short period in high risk area. The hospital management has to concern health of radiation workers more and to put an effort to reduce radiation exposure as low as possible in radiation areas in hospital.

  • PDF

The evaluation of contralateral breast's dose and shielding efficiency by breast size about breast implant patient for radiation therapy (인공 유방 확대술을 받은 환자의 유방암 치료 시 크기에 따른 반대 측 유방의 피폭 선량 및 차폐 효율 평가)

  • Kim, Jong Wook;Woo, Heon;Jeong, Hyeon Hak;Kim, Kyeong Ah;Kim, Chan Yong;Yoo, Suk Hyun
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.26 no.2
    • /
    • pp.329-336
    • /
    • 2014
  • Purpose : To evaluate the dose on a contralateral breast and the usefulness of shielding according to the distance between the contralateral breast and the side of the beam by breast size when patients who got breast implant receive radiation therapy. Materials and Methods : We equipped 200 cc, 300 cc, 400 cc, and 500 cc breast model on the human phantom (Rando-phantom), acquired CT images (philips 16channel, Netherlands) and established the radiation treatment plan, 180 cGy per day on the left breast (EclipseTM ver10.0.42, Varian Medical Systems, USA) by size. We set up each points, A, B, C, and D on the right(contralateral) breast model for measurement by size and by the distance from the beam and attached MOSFET at each points. The 6 MV, 10 MV and 15 MV X-ray were irradiated to the left(target) breast model and we measured exposure dose of contralateral breast model using MOSFET. Also, at the same condition, we acquired the dose value after shielding using only Pb 2 mm and bolus 3 mm under the Pb 2 mm together. Results : As the breast model is bigger from 200 cc to 500 cc, The surface of the contralateral breast is closer to the beam. As a result, from 200 cc to 500 cc, on 180 cGy basis, the measurement value of the scattered ray inclined by 3.22 ~ 4.17% at A point, 4.06 ~ 6.22% at B point, 0.4~0.5% at C point, and was under 0.4% at D point. As the X-ray energy is higher, from 6 MV to 15 MV, on 180 cGy basis, the measurement value of the scattered ray inclined by 4.06~5% at A point, 2.85~4.94% at B point, 0.74~1.65% at C point, and was under 0.4% at D point. As using Pb 2 mm for shield, scattered ray declined by average 9.74% at A and B point, 2.8% at C point, and is under 1% at D point. As using Pb 2 mm and bolus together for shield, scattered ray declined by average 9.76% at A and B point, 2.2% at C point, and is under 1% at D point. Conclusion : Commonly, in case of patients who got breast implant, there is a distance difference by breast size between the contralateral breast and the side of beam. As the distance is closer to the beam, the scattered ray inclined. At the same size of the breast, as the X-ray energy is higher, the exposure dose by scattered ray tends to incline. As a result, as low as possible energy wihtin the plan dose is good for reducing the exposure dose.

Comparison of Treatment Planning System(TPS) and actual Measurement on the surface under the electron beam therapy with bolus (전자선 치료 시 Bolus를 적용한 경우 표면선량의 Treatment Planning System(TPS) 계산 값과 실제 측정값의 비교)

  • Kim, Byeong Soo;Park, Ju Young;Park, Byoung Suk;Song, Yong Min;Park, Byung Soo;Song, Ki Weon
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.26 no.2
    • /
    • pp.163-170
    • /
    • 2014
  • Purpose : If electron, chosen for superficial oncotherapy, was applied with bolus, it could work as an important factor to a therapy result by showing a drastic change in surface dose. Hence the calculation value and the actual measurement value of surface dose of Treatment Planning System (TPS) according to four variables influencing surface dose when using bolus on an electron therapy were compared and analyzed in this paper. Materials and Methods : Four variables which frequently occur during the actual therapies (A: bolus thickness - 3, 5, 10 mm, B: field size - $6{\time}6$, $10{\time}10$, $15{\time}15cm2$, C: energy - 6, 9, 12 MeV, D: gantry angle - $0^{\circ}$, $15^{\circ}$) were set to compare the actual measurement value with TPS(Pinnacle 9.2, philips, USA). A computed tomography (lightspeed ultra 16, General Electric, USA) was performed using 16 cm-thick solid water phantom without bolus and total 54 beams where A, B, C, and D were combined after creating 3, 5 and 10 mm bolus on TPS were planned for a therapy. At this moment SSD 100 cm, 300 MU was investigated and measured twice repeatedly by placing it on iso-center by using EBT3 film(International Specialty Products, NJ, USA) to compare and analyze the actual measurement value and TPS. Measured film was analyzed with each average value and standard deviation value using digital flat bed scanner (Expression 10000XL, EPSON, USA) and dose density analyzing system (Complete Version 6.1, RIT, USA). Results : For the values according to the thickness of bolus, the actual measured values for 3, 5 and 10 mm were 101.41%, 99.58% and 101.28% higher respectively than the calculation values of TPS and the standard deviations were 0.0219, 0.0115 and 0.0190 respectively. The actual values according to the field size were $6{\time}6$, $10{\time}10$ and $15{\time}15cm2$ which were 99.63%, 101.40% and 101.24% higher respectively than the calculation values and the standard deviations were 0.0138, 0.0176 and 0.0220. The values according to energy were 6, 9, and 12 MeV which were 99.72%, 100.60% and 101.96% higher respectively and the standard deviations were 0.0200, 0.0160 and 0.0164. The actual measurement value according to beam angle were measured 100.45% and 101.07% higher at $0^{\circ}$ and $15^{\circ}$ respectively and standard deviations were 0.0199 and 0.0190 so they were measured 0.62% higher at $15^{\circ}$ than $0^{\circ}$. Conclusion : As a result of analyzing the calculation value of TPS and measurement value according to the used variables in this paper, the values calculated with TPS on 5 mm bolus, $6{\time}6cm2$ field size and low-energy electron at $0^{\circ}$ gantry angle were closer to the measured values, however, it showed a modest difference within the error bound of maximum 2%. If it was beyond the bounds of variables selected in this paper using electron and bolus simultaneously, the actual measurement value could differ from TPS according to each variable, therefore QA for the accurate surface dose would have to be performed.

Evaluation of Tangential Fields Technique Using TOMO Direct Radiation Therapy after Breast Partial Mastectomy (유방 부분 절제술 후 방사선 치료 시 TOMO Direct를 이용한 접선 조사의 선량적 유용성에 관한 고찰)

  • Kim, Mi-Jung;Kim, Joo-Ho;Kim, Hun-Kyum;Cho, Kang-Chul;Chun, Byeong-Chul;Cho, Jeong-Hee
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.23 no.1
    • /
    • pp.59-66
    • /
    • 2011
  • Purpose: Investigation of the clinical use of tangential fields technique using TOMO direct in comparison to conventional LINAC based radiation therapy after breast partial mastectomy. Materials and Methods: Treatment plans were created for 3 left-sided breast cancer patients who had radiation therapy after breast partial mastectomy by using wedged tangential fields technique, field in field technique (FIF), TOMO Direct, TOMO Direct intensity modulated radiation therapy (IMRT) under the normalized prescription condition ($D_{90%}$: 50.4 Gy/28 fx within CTV). Dose volume histogram (DVH) and isodose curve were used to evaluate the dose to the clinical target volume (CTV), organ at risk (OAR). We compared and analyzed dosimetric parameters of CTV and OAR. Dosimetric parameters of CTV are $D_{99}$, $D_{95}$, Dose homogeneity index (DHI: $D_{10}/D_{90}$) and $V_{105}$, $V_{110}$. And dosimetric parameters of OAR are $V_{10}$, $V_{20}$, $V_{30}$, $V_{40}$ of the heart and $V_{10}$, $V_{20}$, $V_{30}$ of left lung. Results: Dosimetric results of CTV, the average value of $D_{99}$, $D_{95}$ were $47.7{\pm}1.1Gy$, $49.4{\pm}0.1Gy$ from wedged tangential fields technique (W) and FIF (F) were $47.1{\pm}0.6Gy$, $49.2{\pm}0.4Gy$. And it was $49.2{\pm}0.4$ vs. $48.6{\pm}0.8Gy$, $49.9{\pm}0.4$ vs. $49.5{\pm}0.3Gy$ Gy for the TOMO Direct (D) and TOMO Direct IMRT (I). The average value of dose homogeneity index was W: $1.1{\pm}0.02$, F: $1.07{\pm}0.02$, D: $1.03{\pm}0.001$, I: $1.05{\pm}0.02$. When we compared the average value of $V_{105}$, $V_{110}$ using each technique, it was the highest as $34.6{\pm}9.3%$, $7.5{\pm}7.9%$ for wedged tangential fields technique and the value dropped for FIF as $16.5{\pm}14.8%$, $2.1{\pm}3.5%$, TOMO direct IMRT as $7.5{\pm}8.3%$, $0.1{\pm}0.1%$ and the TOMO direct showed the lowest values for both as 0%. Dosimetric results of OAR was no significant difference among each technique. Conclusion: TOMO direct provides improved target dose homogeneity over wedged tangential field technique. It is no increase the amount of normal tissue volumes receiving low doses, as oppose to IMRT or Helical TOMO IMRT. Also, it simply performs treatment plan procedure than FIF. TOMO Direct is a clinical useful technique for breast cancer patients after partial mastectomy.

  • PDF

Comparison and evaluation of volumetric modulated arc therapy and intensity modulated radiation therapy plans for postoperative radiation therapy of prostate cancer patient using a rectal balloon (직장풍선을 삽입한 전립선암 환자의 수술 후 방사선 치료 시 용적변조와 세기변조방사선치료계획 비교 평가)

  • Jung, hae youn;Seok, jin yong;Hong, joo wan;Chang, nam jun;Choi, byeong don;Park, jin hong
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.27 no.1
    • /
    • pp.45-52
    • /
    • 2015
  • Purpose : The dose distribution of organ at risk (OAR) and normal tissue is affected by treatment technique in postoperative radiation therapy for prostate cancer. The aim of this study was to compare dose distribution characteristic and to evaluate treatment efficiency by devising VMAT plans according to applying differed number of arc and IMRT plan for postoperative patient of prostate cancer radiation therapy using a rectal balloon. Materials and Methods : Ten patients who received postoperative prostate radiation therapy in our hospital were compared. CT images of patients who inserted rectal balloon were acquired with 3 mm thickness and 10 MV energy of HD120MLC equipped Truebeam STx (Varian, Palo Alto, USA) was applied by using Eclipse (Version 11.0, Varian, Palo Alto, USA). 1 Arc, 2 Arc VMAT plans and 7-field IMRT plan were devised for each patient and same values were applied for dose volume constraint and plan normalization. To evaluate these plans, PTV coverage, conformity index (CI) and homogeneity index (HI) were compared and $R_{50%}$ was calculated to assess low dose spillage as per treatment plan. $D_{25%}$ of rectum and bladder Dmean were compared on OAR. And to evaluate the treatment efficiency, total monitor units(MU) and delivery time were considered. Each assessed result was analyzed by average value of 10 patients. Additionally, portal dosimetry was carried out for accuracy verification of beam delivery. Results : There was no significant difference on PTV coverage and HI among 3 plans. Especially CI and $R_{50%}$ on 7F-IMRT were the highest as 1.230, 3.991 respectively(p=0.00). Rectum $D_{25%}$ was similar between 1A-VMAT and 2A-VMAT. But approximately 7% higher value was observed on 7F-IMRT compare to the others(p=0.02) and bladder Dmean were similar among the all plan(P>0.05). Total MU were 494.7, 479.7, 757.9 respectively(P=0.00) for 1A-VMAT, 2A-VMAT, 7F-IMRT and at the most on 7F-IMRT. The delivery time were 65.2sec, 133.1sec, 145.5sec respectively(p=0.00). The obvious shortest time was observed on 1A-VMAT. All plans indicated over 99.5%(p=0.00) of gamma pass rate (2 mm, 2%) in portal dosimetry quality assurance. Conclusion : As a result of study, postoperative prostate cancer radiation therapy for patient using a rectal balloon, there was no significant difference of PTV coverage but 1A-VMAT and 2A-VMAT were more efficient for dose reduction of normal tissue and OARs. Between VMAT plans. $R_{50%}$ and MU were little lower in 2A-VMAT but 1A-VMAT has the shortest delivery time. So it is regarded to be an effective plan and it can reduce intra-fractional motion of patient also.

  • PDF

Long-Term Results of 2-Dimensional Radiation Therapy in Patients with Nasopharyngeal Cancer (이차원방사선치료를 시행한 코인두암 환자의 장기 추적 결과 및 예후인자 분석)

  • Lee, Nam-Kwon;Park, Young-Je;Yang, Dae-Sik;Yoon, Won-Sup;Lee, Suk;Kim, Chul-Yong
    • Radiation Oncology Journal
    • /
    • v.28 no.4
    • /
    • pp.193-204
    • /
    • 2010
  • Purpose: To analyze the treatment outcomes, complications, prognostic factors after a long-term follow-up of patients with nasopharyngeal carcinoma treated with radiation therapy (RT) alone or concurrent chemoradiation therapy (CCRT). Materials and Methods: Between December 1981 and December 2006, 190 eligible patients with non-metastatic nasopharyngeal carcinoma were treated at our department with a curative intent. Of these patients, 103 were treated with RT alone and 87 patients received CCRT. The median age was 49 years (range, 8~78 years). The distributions of clinical stage according to the AJCC 6th edition included I: 7 (3.6%), IIA: 8 (4.2%), IIB: 33 (17.4%), III: 82 (43.2%), IVA: 31 (16.3%), IVB: 29 (15.3%). The accumulated radiation doses to the primary tumor ranged from 66.6~87.0 Gy (median, 72 Gy). Treatment outcomes and prognostic factors were retrospectively analyzed. Acute and late toxicities were assessed using the RTOG criteria. Results: A total of 96.8% (184/190) of patients completed the planned treatment. With a mean follow-up of 73 months (range, 2~278 months; median, 52 months), 93 (48.9%) patients had relapses that were local 44 (23.2%), nodal 13 (6.8%), or distant 49 (25.8%). The 5- and 10-year overall survival (OS), disease-free survival (DFS), and disease-specific survival (DSS) rates were 55.6% and 44.5%, 54.8% and 51.3%, in addition to 65.3% and 57.4%, respectively. Multivariate analyses revealed that CCRT, age, gender, and stage were significant prognostic factors for OS. The CCRT and gender were independent prognostic factors for both DFS and DSS. There was no grade 4 or 5 acute toxicity, but grade 3 mucositis and hematologic toxicity were present in 42 patients (22.1%) and 18 patients (9.5%), respectively. During follow-up, grade 3 hearing loss in 9 patients and trismus in 6 patients were reported. Conclusion: The results of our study were in accordance with findings of previous studies and we confirmed that CCRT, low stage, female gender, and young age were related to improvement in OS. However, there are limitations in the locoregional control that can be achieved by CCRT with 20 conventional radiation therapy. This observation has led to further studies on clarifying the efficacy of concurrent chemotherapy by intensity modulated radiation therapy.

Clinical Outcome after Breast Conserving Surgery and Radiation Therapy for Early Breast Cancer (초기 유방암의 유방 보존수술 후 방사선 치료 결과)

  • Cho, Heung-Lae;Kim, Cheol-Jin;Park, Sung-Kwang;Oh, Min-Kyung;Lee, Jin-Yong;Ahn, Ki-Jung
    • Radiation Oncology Journal
    • /
    • v.26 no.4
    • /
    • pp.204-212
    • /
    • 2008
  • Purpose: This study was performed to evaluate the disease-free survival and risk factors of recurrence in early breast cancer patients who have undergone breast conserving surgery and radiation therapy. Materials and Methods: From March 1997 to December 2002, 77 breast cancer patients who underwent breast conserving surgery and radiation therapy were reviewed retrospectively. The median follow-up time was 58.4 months (range $43.8{\sim}129.4$ months) and the mean subject age was 41 years. The frequency distribution of the different T stages, based on the tumor characteristics was 38 (49.3%) for T1, 28 (36.3%) for T2, 3 for T3, 7 for T is and 1 for an unidentified sized tumor. In addition, 52 patients (67.5%) did not have axillary lymph metastasis, whereas 14 patients (18.1%) had $1{\sim}3$ lymph node metastases and 3 (0.03%) had more than 4 lymph node metastases. The resection margin was negative in 59 patients, close (${\leq}2\;mm$) in 15, and positive in 4. All patients received radiation therapy at the intact breast using tangential fields with a subsequent electron beam boost to the tumor bed at a total dose ranging from 59.4 Gy to 66.4 Gy. Patients with more than four positive axillary lymph nodes received radiation therapy ($41.4{\sim}60.4\;Gy$) at the axillary and supraclavicular area. Chemotherapy was administered in 59 patients and tamoxifen or fareston was administered in 29 patients. Results: The 5 year overall survival and disease-free survival rates were 98.08% and 93.49%, respectively. Of the 77 patients, a total of 4 relapses (5.2%), including 1 isolated supraclavicular relapse, 1 supraclavicular relapse with synchronous multiple distant relapses, and 2 distant relapses were observed. No cases of local breast relapses were observed. Lymph node metastasis or number of metastatic lymph nodes was not found to be statistically related with a relapse (p=0.3289) nor disease-free survival (p=0.1430). Patients with positive margins had a significantly shorter disease-free survival period (p<0.0001) and higher relapse rates (p=0.0507). However, patients with close margins were at equal risk of relapse and disease-free survival as with negative margins (p=1.000). Patients younger than 40 years of age had higher relapse rates (9.3% vs. 0%) and lower disease-free survival periods, but the difference was not statistically significant (p=0.1255). The relapse rates for patients with tumors was 14% for tumor stage T2, compared to 0% for tumor stage T1 tumors (p=0.0284). A univariate analysis found that disease-free survival and relapse rates, T stage, positive resection margin and mutation of p53 were significant factors for clinical outcome. Conclusion: The results of this study have shown that breast conservation surgery and radiation therapy in early breast cancer patients has proven to be a safe treatment modality with a low relapse rate and high disease-free survival rate. The patients with a positive margin, T2 stage, and mutation of p53 are associated with statistically higher relapse rates and lower disease-free survival.

CComparative evaluation of the methods of producing planar image results by using Q-Metrix method of SPECT/CT in Lung Perfusion Scan (Lung Perfusion scan에서 SPECT-CT의 Q-Metrix방법과 평면영상 결과 산출방법에 대한 비교평가)

  • Ha, Tae Hwan;Lim, Jung Jin;Do, Yong Ho;Cho, Sung Wook;Noh, Gyeong Woon
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.22 no.1
    • /
    • pp.90-97
    • /
    • 2018
  • Purpose The lung segment ratio which is obtained through quantitative analyses of lung perfusion scan images is calculated to evaluate the lung function pre and post surgery. In this Study, the planar image production methods by using Q-Metrix (GE Healthcare, USA) program capable of not only quantitative analysis but also computation of the segment ratio after having performed SPECT/CT are comparatively evaluated. Materials and Methods Lung perfusion scan and SPECT/CT were performed on 50 lung cancer patients prior to surgery who visited our hospital from May 1, 2015 to September 13, 2016 by using Discovery 670(GE Healthcare, USA) equipment. AP(Anterior Posterior)method that uses planar image divided the frontal and rear images into three rectangular portions by means of ROI tool while PO(Posterior Oblique)method computed the segment ratio by dividing the right lobe into three parts and the left lobe into two parts on the oblique image. Segment ratio was computed by setting the ROI and VOI in the CT image by using Q-Metrix program and statistically analysis was performed with SPSS Ver. 23. Results Regarding the correlation concordance rate of Q-Metrix and AP methods, RUL(Right upper lobe), RML(Right middle lobe) and RLL(Right lower lobe) were 0.224, 0.035 and 0.447. LUL(Left upper lobe) and LLL(Left lower lobe) were found to be 0.643 and 0.456, respectively. In the PO method, the right lobe were 0.663, 0.623 and 0.702, respectively, while the left lobe were 0.754 and 0.823. When comparison was made by using the Paired sample T-test, Right lobe were $11.6{\pm}4.5$, $26.9{\pm}6.2$ and $17.8{\pm}4.2$, respectively in the AP method. Left lobe were $28.4{\pm}4.8$ and $15.4{\pm}5.6$. The right lobe of PO had values of $17.4{\pm}5.0$, $10.5{\pm}3.6$ and $27.3{\pm}6.0$, while the left lobe had values of $21.6{\pm}4.8$ and $23.1{\pm}6.6$, thereby having statistically significant difference in comparison to the Q-Metrix method for each of the lobes (P<0.05). However, there was no statistically significant difference in Right middle lobe (P>0.05). Conclusion The AP method showed low concordance rate in correlation with the Q-Metrix method. However, PO method displayed high concordance rate overall. although AP method had significant differences in all lobes, there was no significant difference in Right middle lobe of PO method. Therefore, at the time of production of lung perfusion scan results, utilization of Q-Metrix method of SPECT/CT would be useful in computation of accurate resultant values. Moreover, it is deemed possible to expect obtain more practical sectional computation result values by using PO method at the time of planar image acquisition.