• Title/Summary/Keyword: low-dose CT

검색결과 212건 처리시간 0.022초

Myocardial Blood Flow Quantified by Low-Dose Dynamic CT Myocardial Perfusion Imaging Is Associated with Peak Troponin Level and Impaired Left Ventricle Function in Patients with ST-Elevated Myocardial Infarction

  • Jingwei Pan;Mingyuan Yuan;Mengmeng Yu;Yajie Gao;Chengxing Shen;Yining Wang;Bin Lu;Jiayin Zhang
    • Korean Journal of Radiology
    • /
    • 제20권5호
    • /
    • pp.709-718
    • /
    • 2019
  • Objective: To investigate the association of myocardial blood flow (MBF) quantified by dynamic computed tomography (CT) myocardial perfusion imaging (MPI) with troponin level and left ventricle (LV) function in patients with ST-segment elevated myocardial infarction (STEMI). Materials and Methods: Thirty-five STEMI patients who successfully had undergone reperfusion treatment within 1 week of their infarction were consecutively enrolled. All patients were referred for dynamic CT-MPI. Serial high-sensitivity troponin T (hs-TnT) levels and left ventricular ejection fraction (LVEF) measured by echocardiography were recorded. Twenty-six patients with 427 segments were included for analysis. Various quantitative parameters derived from dynamic CT-MPI were analyzed to determine if there was a correlation between hs-TnT levels and LVEF on admission and again at the 6-month mark. Results: The mean radiation dose for dynamic CT-MPI was 3.2 ± 1.1 mSv. Infarcted territories had significantly lower MBF (30.5 ± 7.4 mL/min/100 mL versus 73.4 ± 8.1 mL/min/100 mL, p < 0.001) and myocardial blood volume (MBV) (2.8 ± 0.9 mL/100 mL versus 4.2 ± 1.1 mL/100 mL, p = 0.044) compared with those of reference territories. MBF showed the best correlation with the level of peak hs-TnT (r = -0.682, p < 0.001), and MBV showed a moderate correlation with the level of peak hs-TnT (r = -0.437, p = 0.026); however, the other parameters did not show any significant correlation with hs-TnT levels. As for the association with LV function, only MBF was significantly correlated with LVEF at the time of admission (r = 0.469, p = 0.016) and at 6 months (r = 0.585, p = 0.001). Conclusion: MBF quantified by dynamic CT-MPI is significantly inversely correlated with the level of peak hs-TnT. In addition, patients with lower MBF tended to have impaired LV function at the time of their admission and at 6 months.

비 상업용 3차원 치료계획시스템인 Plunc의 임상적용 가능성에 대한 연구 (A Study of a Non-commercial 3D Planning System, Plunc for Clinical Applicability)

  • 조병철;오도훈;배훈식
    • Radiation Oncology Journal
    • /
    • 제16권1호
    • /
    • pp.71-79
    • /
    • 1998
  • 목적 : 비 상업용 3차원 컴퓨터치료계획시스템인 Plunc의 구축 사례를 소개하고 이의 임상적용 가능성에 대하여 검증하고자 한다. 대상 및 방법 : 미국 North Carolina 대학에서 개발된 3차원 치료계획시스템인 Plunc의 소스코드를 제공받아, PC용 Unix인 Linux 환경의 Pentium Pro 200MHz(128MB RAM, Millennium VGA)에서 설치하였다. 본과의 6MV 광자선(Siemens MXE 6740)에 대한 출력인자, 최대산란비, 최대산란인자, 쐐기의 모양 및 감쇄인자 등의 빔데이터를 입력한 후, 일반적인 치료조건인 loom 깊이의 회전중심점에서의 심부선량백분율, 선량측면도, oblique 입사빔 및 공기간격 하에서의 선량계산 결과를 물팬톰에서의 측정치와 비교, 분석하였다. 결과 : Plunc는 원래 CT 영상데이터를 이용한 모의치료기로써 개발되어, 빔 설계가 매우 편리하도록 사용자 인터페이스가 구성되어 있으며, BEV, DRR 및 영상합성 등의 기능을 갖추고 있다. 선량계산은 10초 정도가 소요되는 3차원 선량분포나 선량체적히스토그람을 제외하고는 거의 실시간으로 실행되었다. Plunc에 의한 선량 계산 값을 측정값과 비교한 결과, 심부선량백분율의 경우, 선량증가영역을 제외하고는 $1\%$이내에서 일치하였다. 또한, 선량측면도의 경우, $5\%$가량의 선량감소를 나타내는 치료영역 크기 밖의 저선량 영역을 제외하고는 $2\%$ 이내에서 일치하였다. Oblique 입사 빔의 경우, 빔 중심축을 포함하는 평면상의 선량분포가 선량이 $30\%$ 이하인 영역을 제외하고는 비교적 잘 일치하였다. 공기간격을 통과한 빔에 대한 선량측면도의 비교 결과, 중심 축에서의 선량 값에 대해 $5\%$의 오차를 보였다. 결론 : Plunc의 광자선량계산의 정밀도는 일반적인 치료조건하에서 약 $2-5\%$ 내외의 오차로써, 측정치에 대한 보정에 근거한 알고리즘을 사용하는 일반 치료계획시스템과 비슷한 수준이라 사료된다. 현재로서는 전자선에 대한 선량계산이 불가능하기 때문에 완전한 형태의 치료계획시스템이 되기 위해서는 향후, 전자선에 대한 계산모듈의 개발과 광자선 선량계산 또한 보다 정밀한 선량계산이 가능한 컨벌루션 방법과 같은 3차원 선량계산모듈의 개발도 필요하다. Plunc는 상업용 3차원 치료계획 시스템의 사용이 현실적으로 어려운 여건의 병원에서 2차원 치료계획시스템과 상호 보완적으로 사용한다면 2차원 치료계획시스템이 갖는 많은 제약을 극복할 수 있을 것으로 사료된다.

  • PDF

다양한 팬텀 모양 및 재질에 따른 전산화단층촬영장치 선량 평가 (Estimation of Computed Tomography Dose in Various Phantom Shapes and Compositions)

  • 이창래
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제40권1호
    • /
    • pp.13-18
    • /
    • 2017
  • 본 논문은 GATE (geant4 application for tomographic emission) 시뮬레이션을 이용하여 다양한 모양과 재질의 팬텀에서 CTDI (computed tomography dose index)를 평가하였다. GATE 시뮬레이션은 실린더 기둥, 타원 기둥과 육각 기둥 형태와 물, PMMA (polymethyl methacrylate), polyethylene 그리고 polyoxymethylene 재질의 다양한 지름(1 ~ 50 cm)의 팬텀을 모사하여 $CTD_{I100center}$ 값을 비교하였다. 120 kV, 200 mAs에서 실린더 기둥, 타원 기둥과 육각 기둥의 $CTDI_{100center}$ 값은 각각 11.1, 13.4 그리고 12.2 mGy이었다. 이 결과는 동일 볼륨이지만 팬텀의 형태에 따라 $CTDI_{100center}$ 값의 차이가 있음을 알 수 있다. 그리고 물, PMMA 그리고 polyoxymethylene 팬텀의 $CTDI_{100center}$ 값을 비교했을 때 물질의 밀도가 높을수록 상대적으로 $CTDI_{100center}$ 값이 낮게 측정되었다. 하지만 polyethylene의 경우 지름이 15 cm ($CTDI_{100center}$ : 35.0 mGy) 이 상에서는 PMMA 보다 $CTDI_{100center}$ 값이 증가하였다. 그리고 30 cm ($CTDI_{100center}$ : 17.7 mGy) 이 상의 지름에서는 물 보다 더 높은 $CTDI_{100center}$ 값을 보였다. 본 실험을 통해 팬텀의 재질 및 모양에 따른 $CTDI_{100center}$ 값을 GATE 시뮬레이션을 이용하여 평가하였다. CT 선량 평가시 다양한 재질 및 인체에 가까운 모양의 팬텀을 사용함으로써 좀 더 정확한 환자선량을 평가할 수 있을 것이다.

Cell-Based IL-15:IL-15Rα Secreting Vaccine as an Effective Therapy for CT26 Colon Cancer in Mice

  • Thi, Van Anh Do;Jeon, Hyung Min;Park, Sang Min;Lee, Hayyoung;Kim, Young Sang
    • Molecules and Cells
    • /
    • 제42권12호
    • /
    • pp.869-883
    • /
    • 2019
  • Interleukin (IL)-15 is an essential immune-modulator with high potential for use in cancer treatment. Natural IL-15 has a low biological potency because of its short half-life and difficulties in mass-production. IL-15Rα, a member of the IL-15 receptor complex, is famous for its high affinity to IL-15 and its ability to lengthen the half-life of IL-15. We have double-transfected IL-15 and its truncated receptor IL-15Rα into CT26 colon cancer cells to target them for intracellular assembly. The secreted IL-15:IL-15Rα complexes were confirmed in ELISA and Co-IP experiments. IL-15:IL-15Rα secreting clones showed a higher anti-tumor effect than IL-15 secreting clones. Furthermore, we also evaluated the vaccine and therapeutic efficacy of the whole cancer-cell vaccine using mitomycin C (MMC)-treated IL-15:IL-15Rα secreting CT26 clones. Three sets of experiments were evaluated; (1) therapeutics, (2) vaccination, and (3) long-term protection. Wild-type CT26-bearing mice treated with a single dose of MMC-inactivated secreted IL-15:IL-15Rα clones prolonged survival compared to the control group. Survival of MMC-inactivated IL-15:IL-15Rα clone-vaccinated mice (without any further adjuvant) exceeded up to 100%. This protection effect even lasted for at least three months after the immunization. Secreted IL-15:IL-15Rα clones challenging trigger anti-tumor response via CD4+ T, CD8+ T, and natural killer (NK) cell-dependent cytotoxicity. Our result suggested that cell-based vaccine secreting IL-15:IL-15Rα, may offer the new tools for immunotherapy to treat cancer.

The Value of Computed Tomography Scan in Three-dimensional Planning and Intraoperative Navigation in Primary Total Hip Arthroplasty

  • Fabio Mancino;Andreas Fontalis;Ahmed Magan;Ricci Plastow;Fares S. Haddad
    • Hip & pelvis
    • /
    • 제36권1호
    • /
    • pp.26-36
    • /
    • 2024
  • Total hip arthroplasty (THA) is a frequently performed procedure; the objective is restoration of native hip biomechanics and achieving functional range of motion (ROM) through precise positioning of the prosthetic components. Advanced three-dimensional (3D) imaging and computed tomography (CT)-based navigation are valuable tools in both the preoperative planning and intraoperative execution. The aim of this study is to provide a thorough overview on the applications of CT scans in both the preoperative and intraoperative settings of primary THA. Preoperative planning using CT-based 3D imaging enables greater accuracy in prediction of implant sizes, leading to enhancement of surgical workflow with optimization of implant inventory. Surgeons can perform a more thorough assessment of posterior and anterior acetabular wall coverage, acetabular osteophytes, anatomical landmarks, and thus achieve more functional implant positioning. Intraoperative CT-based navigation can facilitate precise execution of the preoperative plan, to attain optimal positioning of the prosthetic components to avoid impingement. Medial reaming can be minimized preserving native bone stock, which can enable restoration of femoral, acetabular, and combined offsets. In addition, it is associated with greater accuracy in leg length adjustment, a critical factor in patients' postoperative satisfaction. Despite the higher costs and radiation exposure, which currently limits its widespread adoption, it offers many benefits, and the increasing interest in robotic surgery has facilitated its integration into routine practice. Conducting additional research on ultra-low-dose CT scans and examining the potential for translation of 3D imaging into improved clinical outcomes will be necessary to warrant its expanded application.

인형 모의피폭체내 MOSFET 선량계의 에너지 및 방향 의존도를 고려하기 위한 선량보정인자 결정 (Determination of Dose Correction Factor for Energy and Directional Dependence of the MOSFET Dosimeter in an Anthropomorphic Phantom)

  • 조성구;최상현;나성호;김찬형
    • Journal of Radiation Protection and Research
    • /
    • 제31권2호
    • /
    • pp.97-104
    • /
    • 2006
  • 최근 방사선 치료 및 진단 분야에서 선량 측정을 위하여 다양하게 사용되고 있는 MOSFET 선량계는 검출부위가 실리콘으로 이루어져 있으며 다른 검출기들과 마찬가지로 어느 정도의 에너지 의존도와 방향 의존도를 보인다. 따라서 MOSFET 선량제가 공기 중이 아닌 모의피폭체 내에서 선량 측정에 사용될 경우 낮은 에너지를 갖는 산란 광자 등 이차 광자들로 인하여 선량을 실제보다. 높게 평가하게 된다. 본 연구에서는 MOSFET 선량계의 에너지 의존도와 방향 의존도로 인하여 발생하는 오차를 보정하기 위한 선량보정인자를 몬테카를로 전산모사 기법을 이용하여 계산하였다. 먼저 사용되는 인형 모의 피폭체의 체적소 모의피폭체(Voxel Phanom)를 CT 영상을 이용하여 제작하였으며 제작된 체적소 모의 피폭체를 몬테카를로 전산코드로 구현한 후, 모의피폭체 내 각 선량계 지점에서 입사하는 광자의 에너지 및 방향별 에너지 스펙트럼을 계산하였다. 각각의 선량계 지점에서 0.662 MeV와 1.25 MeV의 광자빔을 고려하였으며 또한 MOSFET 선량계의 방향은 실리콘 베이스 방향과 에폭시 방향을 고려하였다. 주어진 선량제 지점에서의 선량보정인자는 계산된 에너지 의존도들의 중간간을 이용하여 결정하였으며 이렇게 결정된 각 선량계 지점에서 선량보정인자는 0.89-0.97 범위의 값들을 나타내었다. 본 연구결과에 따르면 MOSFET 선량계를 이용하여 인형 모의피폭체 내에 선량을 측정할 때 에너지 의존도와 방향 의존도를 고려하지 않을 경우 측정 위치에 따라 $3{\sim}11%$ 정도의 측정오차가 발생할 수 있다. 그러므로 인형 모의피폭체 내의 선량을 정확하게 측정하기 위해서는 선량보정인자를 각 선량계에 필히 적용해주어야 한다.

Sprague-Dawley 랫드에서 60일간 용접흄 폭로에 의한 폐기능 변화 (Changes of Pulmonary Function!) During 60 days of Welding Fume Exposure Period 1m Sprague-Dawley Rats)

  • 성재혁;최병길;맹승희;김수진;정용현;한정희;현진숙;송경석;조영봉
    • Toxicological Research
    • /
    • 제20권1호
    • /
    • pp.55-61
    • /
    • 2004
  • Respiratory effects in full time welders include bronchitis, airway irritation, lung function changes, and lung fibrosis. Welder's pneumoconiosis has been generally determined to be benign and not associated with respiratory symptoms based on the absence of pulmonary function abnormalities in welders with marked radiographic abnormalities. Accordingly, to investigate pulmonary function changes during 60 days induced by welding-fume exposure, male Sprague-Dawley rats were exposed to manual metal arc-stainless steel (MMA-SS) welding fumes with concentrations of 64.8$\pm$0.9 mg/$m^3$ (low dose) and 107.8 $\pm$ 2.6 mg/$m^3$ (high dose) total suspended particulates for 2 hr/day, 5 days/week in an inhalation chamber for 60 days. Pulmonary function was measured every week with whole body plethysmograph compensated (WBP Comp, SFT38116, Buxco Electronics, Sharon, CT). The rats exposed to the high dose of welding fumes exhibited statistically significant (p<0.05~0.01) body weight decrease as compared to the control whereas cell number increase of the bronchoalveolar lavage fluid (BALF) (total cell, macrophage, polymorphonuclear cell and lymphocyte) during the 60 days exposure period. And only tidal volume was significantly decreased in dosedependantly during 60 days of MMA-SS welding fume exposure. This pulmonary function change with inflammatory cell recruitment confirms the lung injury caused by the MMA-SS welding fume exposure.

소아 심장 CT검사 시 Wide Coverage Volume Axial Mode의 유용성 평가 (Evaluation of the Availability of the Wide Coverage Volume Axial Mode in Pediatric Cardiac CT)

  • 박기석;김동현
    • 한국방사선학회논문지
    • /
    • 제13권5호
    • /
    • pp.683-689
    • /
    • 2019
  • 소아의 선천적 심장질환 진단을 위해 High Pitch Mode를 사용하여 획득한 소아 심장 CT 영상과 Wide Coverage Volume Axial Mode를 사용하여 획득한 소아 심장 CT 영상으로부터 환자의 피폭선량과 각 영상의 화질을 비교 및 분석하여 Wide Coverage Volume Axial Mode의 유용성을 평가해보고자 한다. 소아 심장 CT 검사 시 High Pitch Mode와 Wide Coverage Volume Axial Mode를 각각 50명 총 100명의 환자를 대상으로 시행하였으며, 각 프로토콜로부터 얻은 영상을 이용하여 환자의 피폭선량을 비교하였다. 각 영상에 ROI를 설정해 SNR과 CNR을 산출하여 영상의 화질을 비교하였다. High Pitch Mode에 비해 Wide Coverage Volume Axial Mode를 사용하여 검사하였을 때 환자의 피폭선량이 13.07% 감소하였고, SNR과 CNR이 향상되었다. Wide Coverage Volume Axial Mode는 고속 회전 스캐너를 이용하여 조사시간을 줄이고, 저선량 기술인 ASi R-V를 통해 High Pitch Mode를 사용했을 때보다 환자의 피폭선량이 감소하고 영상의 화질 또한 향상되는 유용한 검사라 할 수 있다.

저선량 흉부전산화단층촬영의 흡기 영상과 폐기능이 정상인 성인에서 호기 말 폐 감쇄도 증가 정도와 연령 및 흡연과의 연관성 (Correlation between Expiratory Increase of Lung Attenuation and Age and Smoking in the Subjects with Normal Inspiratory Low Dose CT and Pulmonary Function Test)

  • 권성연;황용일;윤호일;이재호;이춘택;이경원
    • Tuberculosis and Respiratory Diseases
    • /
    • 제65권6호
    • /
    • pp.457-463
    • /
    • 2008
  • 연구배경: 호기말에 흉부 촬영을 시행하면 폐 내의 공기의 부피가 감소되어 폐 감쇄도가 증가한다. 이런 폐 감쇄도의 변화가 국소적으로 저하되는 공기 가둠 현상에 대해서는 일부 연구들이 있었으나 전체 폐의 전반적인 감쇄도 변화에 대한 연구는 거의 없고, 특히 정상인을 대상으로 한 연구는 거의 없다. 저자들은 호흡기 질환이 없으며 폐기능 및 흡기 전산화단층촬영이 정상 소견이고 호기 영상에서 국소적인 공기 가둠 현상이 없는 100명을 대상으로 연구를 수행하였다. 방 법: 흉부 전산화단층촬영 영상에서 24개의 지점을 정하고, 흡기 및 호기 시 각 지점에서 폐 음영도를 측정한 후 호기말 폐 감쇄도 증가와 흡연량, 연령 사이의 상관 관계를 알아보았다. 결 과: 연구 대상 100명의 연령은 중앙값 49.0세(범위 25~71세)였고, 평균 흡연량은 $22.5{\pm}17.0$갑년이었다. 연령과 폐 감쇄도의 증가 사이에는 유의한 음의 상관관계가 있었으며 이는 흡연의 효과를 보정하였을 때에도 유지되었고, 연령을 기준으로 세 군으로 나누어 폐 감쇄도의 증가 정도를 비교하였을 때에도 유의한 차이가 있었다. 흡연량과 호기말 폐 감쇄도의 증가 사이에는 유의한 음의 상관관계가 관찰되었으나 연령을 보정하였을 때에는 유의성이 감소하였다. 결 론: 흡기-호기 시의 폐의 전반적인 감쇄도 변화 정도는 연령과 상관관계가 있으며, 노화를 반영할 가능성이 있다.

Cone-beam computed tomography: Time to move from ALARA to ALADA

  • Jaju, Prashant P.;Jaju, Sushma P.
    • Imaging Science in Dentistry
    • /
    • 제45권4호
    • /
    • pp.263-265
    • /
    • 2015
  • Cone-beam computed tomography (CBCT) is routinely recommended for dental diagnosis and treatment planning. CBCT exposes patients to less radiation than does conventional CT. Still, lack of proper education among dentists and specialists is resulting in improper referral for CBCT. In addition, aiming to generate high-quality images, operators may increase the radiation dose, which can expose the patient to unnecessary risk. This letter advocates appropriate radiation dosing during CBCT to the benefit of both patients and dentists, and supports moving from the concept of "as low as reasonably achievable" (ALARA) to "as low as diagnostically acceptable" (ALADA).