• Title/Summary/Keyword: low-band type

Search Result 387, Processing Time 0.025 seconds

Design of Low-Pass Type Inverter: UWB Band-Pass Filter with Low Spurious Characteristics

  • Cho, Young-Ho;Choi, Moon-Gyu;Yun, Sang-Won
    • Journal of electromagnetic engineering and science
    • /
    • v.11 no.2
    • /
    • pp.83-90
    • /
    • 2011
  • In this paper, we present the design method for a low-pass type inverter, which can effectively suppress the spurious response associated with band-pass filters. The inverter has a length of ${\lambda}/4$ and employs not only a stepped-impedance configuration but also asymmetrical and bending structures in order to improve frequency selectivity and compactness. The inverter is applied as an impedance/admittance inverter to the ultra-wideband (UWB) band-pass filter. The UWB band-pass filter configuration is based on a stub band-pass filter consisting of quarter-wavelength impedance inverters and shunt short-circuited stubs ${\lambda}/4$ in length. The asymmetrical stepped-impedance low-pass type inverter improves not only the spurious responses, but also the return loss characteristics associated with a UWB band-pass filter, while a compact size is maintained. The UWB band-pass filter using the proposed inverters is fabricated and tested. The measured results show excellent attenuation characteristics at out-band frequencies, which exceed 18 dB up to 39 GHz. The insertion loss within the pass-band (from 3.1 to 10.6 GHz) is below 1.7 dB, the return loss is below 10 dB, and the group delay is below 1 ns.

Development of a Direct-Operated Proportional Pressure Reducing Valve for Low-Band Type Active Suspension Control (Low-Band Type 능동형 현가제어를 위한 직동식 전자비례 감압밸브의 개발)

  • 홍예선;류시복;김영식
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.2 no.3
    • /
    • pp.75-84
    • /
    • 1994
  • In general direct-operated pressure reducing valves have been gardly applied to a dynamic control system such as active suspension control because of their poor control stability. But they are more robust than pilot-operated type and do not need pilot control flow. In this paper development of a new direct-operated proportional pressure reducing valve for low-band type active suspension control is reported. By means of a special damper directly linked to the valve spool, the control stability could be effectively improved without drawback in response time. The linearity error was less than $\pm$3.5%. Applied to an experimental active suspension system the new valve showed the $-90^{\circ}$ phase delay at 4Hz with 20% sinusoidal signal input and could control the suspension system with almost same performance as that with a pilot-operated type valve.

  • PDF

Deduction of a Simplified Model for the Hydraulic Actuator for a Low-band Type Suspension System (능동제어식 현가계의 유압 구동장치에 대한 단순화 모델 유도)

  • 김동윤;홍예선;박영필
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.2 no.4
    • /
    • pp.27-38
    • /
    • 1994
  • In this paper, a simplified model of a hydraulic actuator system for a low-band type active suspension system is derived. To reduce the order of model, time constants of each chamber in hydraulic system are neglected except that of an accumulator. And the dynamics of a spool in the pressure control valve is regarded as a first-order system. The step response and the frequency response of the simplified second-order simulation model exhibit a good agreement with those of the actual system as well as those of the tenth-order simulation model. It is possible to simplify the tenth-order model to the second-order one. The low-band type active suspension model is built up by combining of a quarter car model test rig to testify the validity of the simplified model. The experimental results of suspension characteristics show that the simplified second-order hydraulic actuator model is reasonable to describe the dynamics of the actual hydraulic actuator system for a low-band type active suspension system.

  • PDF

Fabrication of high-temperature superconducting low-pass filter for broad-band harmonic rejection (광대역 고조파 제거를 위한 고온초전도 저역통과필터의 제작)

  • Han, Seok-Gil;Kang, Gwang-Yong;Ahn, Dal;Suh, Jun-Seok;Choi, Chun-Geun;Kim, Sang-Hyeon;Kwak, Min-Hwan
    • 한국초전도학회:학술대회논문집
    • /
    • v.10
    • /
    • pp.193-196
    • /
    • 2000
  • A new type low-pass filter design method based on a coupled line and transmission line theory is proposed to suppress harmonics by attenuation poles in the stop band. The design formula are derived using the equivalent circuit of a coupled transmission line. The new low-pass filter structure is shown to have attractive properties such as compact size, wide stop band range and low insertion loss. The seventh-order low-pass filter designed by present method has a cutoff frequency of 0.9 CHz with a 0.01 dB ripple level. The coupled line type low-pass filter with strip line configuration was fabricated by using a high-temperature superconducting (HTS : YBa$_2$Cu$_3$O$_{7-{\delta}}$ thin film on MgO(100) substrate. Since the HTS coupled tine type low-pass filter was proposed with five attenuation poles in stop band such as 1.8, 2.5, 4, 5.5, 6.2 GHz. The fabricated low-pass filter has improved the attenuation characteristics up to seven times of the cutoff frequency.

  • PDF

A Design of High Temperature Superconducting Low-Pass Filter for Broad-Band Harmonic Rejection (광대역 고조파 제거용 고온초전도 저역통과 필터의 설계)

  • Kwak, Min-Hwan;Kim, Sang-Hyun;Ahn, Dal;Han, Seok-Kil;Kang, Kwang-Yong
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2000.05b
    • /
    • pp.78-81
    • /
    • 2000
  • A new type low-pass filter design method based on a coupled line and transmission line theory is proposed to suppress harmonics by attenuation poles in the stop band The design formula are derived using the equivalent circuit of a coupled transmission line. The new low-pass filter structure is shown to have attractive properties such as compact size, wide stop band range and low insertion loss. The seventh-order low-pass filter designed by present method Ins a cutoff frequency of 0.9 GHz with a 0.01 dB ripple level. The coupled line type low-pass filter with stripline configuration was fabricated by using a high-temperature superconducting (HTS ; $YBa_2Cu_3O_{7-x}$) thin film on MgO(100) substrate. Since the HTS coupled line type low-pass filter was proposed with five attenuation poles in stop band such as 1.8, 2.5, 4, 5.5, 62 GHz. The fabricated low-pass filter has improved the attenuation characteristics up to seven times of the cutoff frequency Bemuse of good rejection of the spurious signals and harmonics, our low-pass filter is applicable to mobile base station systems such as cellular, personal communication systems and international mobile telecommunication(IMT)-2000 systems.

  • PDF

A study on the wsggm-based spectral modeling of radiation properties of water vapor (회체가스중합법에 의한 수증기의 파장별 복사물성치 모델에 관한 연구)

  • Kim, Uk-Jung;Song, Tae-Ho
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.20 no.10
    • /
    • pp.3371-3380
    • /
    • 1996
  • Low resolution spectral modeling of water vapor is carried out by applying the weighted-sum-of-gray-gases model (WSGGM) to a narrow band. For a given narrow band, focus is placed on proper modeling of gray gas absorption coefficients vs. temeprature relation used for any solution methods for the Radiative Transfer Equation(RTE). Comparison between the modeled emissivity and the "true" emissivity obtained from a high temperatue statistical narrow band parameters is made ofr the total spectrum as well as for a few typical narrow bands. Application of the model to nonuniform gas layers is also made. Low resolution spectral intensities at the boundary are obtained for uniform, parabolic and boundary layer type temeprature profiles using the obtained for uniform, parabolic and boundary layer type temperature profiles using the obtained WSGGM's with 9 gray gases. The results are compared with the narrow band spectral intensities as obtained by a narrow band model-based code with the Curtis-Godson approximation. Good agreement is found between them. Local heat source strength and total wall heat flux are also compared for the cases of Kim et al, which again gives promising agreement.

Design of Ka-Band 3 Stage MMIC Low Noise Amplifiers (KaBand 3단 MMIC 저잡음 증폭기 설계)

  • 염인복;정진철;이성팔
    • Proceedings of the Korea Electromagnetic Engineering Society Conference
    • /
    • 2000.11a
    • /
    • pp.216-219
    • /
    • 2000
  • A Ka Band 3-stage MMIC (Monolithic Microwave Integrated Circuits) LNA(Low Noise Amplifiers) has been designed. The MMIC LNA consists of two single-ended type amplication stapes and one balanced type amplication stage to satisfy noise figure characteristics and high gain and amplitude linearity. The 0.15um pHEMT has been used to provide a ultra low noise figure and high gain amplification. Series and Shunt feedback circuits were inserted to ensure high stability over frequency range of DC to 80 GHz. The size of designed MMIC LNA is 3100mm ${\times}$ 2400um(7.44$\textrm{mm}^2$). The on wafer measured noise figure of the MMIC LNA is less than 2.0 dB over frequency range of 22 GHz to 30 GHz.

  • PDF

Design of a Novel low Pass Filler will Low Spurious Response for Satellite Transponder (위성중계기를 위한 낮은 불요 특성을 갖는 새로운 형태의 저역통과 필터 설계)

  • 이문규;류근관;염인복;이성팔
    • Proceedings of the Korea Electromagnetic Engineering Society Conference
    • /
    • 2001.11a
    • /
    • pp.172-175
    • /
    • 2001
  • A novel microstrip type low-pass filter using thin or thick film resistors is proposed to efficiently eliminate harmonic spurious response in stop-band. The proposed low-pass filter shows the spurious suppression enhancement of 20 dB over a conventional one. The designed low-pass filter could be used as a harmonic rejection filter of a local oscillator for Ku-band satellite payload system.

  • PDF

Design and Fabrication of a S-BAND Receiver for Low Orbit Satellite (저궤도 위성용 S-BAND 수신기 설계 및 제작)

  • Choi, Young-Jin
    • Proceedings of the IEEK Conference
    • /
    • 2005.11a
    • /
    • pp.35-38
    • /
    • 2005
  • In this study, S-Band receiver for low orbit satellite is implemented. The developed receiver is double super-heterodyne type and STDN compatible. Input/output frequency of receiver is 2034.747MHz and 18.414MHz used for KOMPSAT 2 satellite. Overall gain(@AGC=0V) and image rejection were 92.4dB and 50.2dB respectively. It was verified that receiver has stable performance to the temperature limit, power supply voltage variation and input signal level range.

  • PDF

The Effects of the Band Type Foot Drop Device (밴드형 첨족예방기구의 효과와 유용성)

  • Kang Hyun-Sook;Kim Won-Ock;Lee Hya-Sook
    • Journal of Korean Academy of Fundamentals of Nursing
    • /
    • v.7 no.3
    • /
    • pp.391-400
    • /
    • 2000
  • A long-term bed rest results in an inevitable foot drop. Yet preventive device such as a foot board and high-neck tennis shoes, are not widely used. This study was conducted to compare the effects of a pillow-type foot board with that of the band-type device. The band-type device of a resonable price is designed for an effective prevention of foot drop, and the convenience for it use. Among the non-equivalent control group design, foot drop preventive effects, usefulness of the device, as well as its cost effectiveness were examined. The study was carried out for four months from December 1999, and its subject had been patients and nurses of two intensive care units at K medical center in Seoul. According to the study purpose, the data collected were analyzed by $x^2-test$ and t-test. The results are as follow : 1. The ROM of ankle joint is promoted in the experimental group with a band-type device comparing the control group with a pillow type one. Dorsiflexion is particularly increased in the experimental group as compared with the control group, while planterflexion hardly shows any change. 2. The usefulness score of the experimental group nurses using the band-type device (23.97) is higher than that of the control group nurses (18.88). 3. In an aspect of the unit production cost, band-type devices are low-priced compare with pillow-type or other foot board (wooden) or high-neck tennis shoes. In summary, the newly developed band-type device is both useful and preventive for a foot drop. It is also desirable regarding to the production cost and the cost effectiveness. This fact proves that the new anti-foot drop device could be practical both for clinical care and home care. Yet the results were obtained by some subjects, it should be used after a further examination. More effective nursing intervention could be observed throughout general studies, including proper positioning and foot and ankle exercises which are the important variables of the foot drop prevention.

  • PDF