Single-Phase Self-Excited Induction Generator with Static VAR Compensator Voltage Regulation for Simple and Low Cost Stand-Alone Renewable Energy Utilizations Part II : Simulation and Experimental Results

  • Ahmed, Tarek;Noro, Osamu;Soshin, Koji;Sato, Shinji;Hiraki, Eiji;Nakaoka, Mutsuo
    • KIEE International Transactions on Power Engineering
    • /
    • 제3A권1호
    • /
    • pp.27-34
    • /
    • 2003
  • In this paper, the power conditioner composed of the stand-alone single-phase squirrel cage rotor type self-excited induction generator (SEIG) driven by prime movers such as a wind turbine and a micro gas turbine (MGT) is presented by using the steady-state circuit analysis based on the two nodal admittance approaches using the per-unit frequency in addition to a new state variable defined by the per-unit slip frequency along with its performance evaluations for the stand-alone energy utilizations. The stande-alone single-phase SEIG operating performances in unregulated voltage control loop are then evaluated on line under the conditions of the speed change transients of the prime mover and the stand-alone electrical passive load power variations with the simple theoretical analysis and the efficient computation processing procedures described in the part I of this paper. In addition, a feasuible PI controlled feedback closed-loop voltage regulation scheme of the stande-alone single-phase SEIG is designed on the basis of the static VAR compensate. (SVC) and discussed in experiment for the promising stand-alone power conditioner. The experimental operating performance results are illustrated and give good agreements with the simulation ones. The simulation and experimental results of the stand-alone single-phase SEIG with the simple SVC controller for its stabilized voltage regulation prove the practical effectiveness of the additional SVC control loop scheme including the PI controller with fast response characteristics and steady-sate performance improvements.

2009년 남해안 전역에 발생된 고니아룩스 적조에 관한 연구 (The Massive Blooms of Gonyaulax polygramma (Gonyaulacales, Dinophyceae) in the Southern Coastal Areas of Korea in Summer, 2009)

  • 조은섭
    • 한국환경과학회지
    • /
    • 제20권12호
    • /
    • pp.1521-1531
    • /
    • 2011
  • This study was carried out to determine the characteristics of the marine environment, including nutritional content, in order to clearly understand the outbreaks of Gonyaulax polygramma in the southern coastal areas in August, 2009. Samples were collected at 13 sites and water temperature and salinity were measured using a CTD. Field surveys were twice: the first between August 5-7, the second between August 22-24. The cell density of G. polygramma was 6,500-10,000 cells $ml^{-1}$ during the $1^{st}$ survey, whereas during the $2^{nd}$ survey the range of the cells was recorded from 8,000 to 12,500 cells $ml^{-1}$. Cochlodinium polykrikoides ranged from 0 to 105 cells $l^{-1}$ during the field survey. In water environments, the majority stations during the $1^{st}$ survey showed a nearly homogeneous water column below $1^{\circ}C$ in temperature, as well as similar profiles of salinity. However, the stratification between the surface and bottom was observed in the $2^{nd}$ survey. Regarding nutrients, Dissolved Inorganic Nitrogen (DIN) in the surface ranged from 0.144 to 0.236 mg $l^{-1}$ during the $1^{st}$ survey, and 0.082-0.228 mg $l^{-1}$ during the $2^{nd}$ survey. DIP (Dissolved Inorganic Phosphorus) did not show any difference in concentration between the $1^{st}$ and $2^{nd}$ survey. During August of 2009, the wind speed in the southern waters remained at around ${\leq}2\;m\;s^{-1}$ for about 60% of time, and there was very little precipitation during the month. Irradiance of ${\geq}10$ hr was shown in the late of August. It is thought that a low level of DIN and salinity play an important role as an essential factor for rapid growth, wide distribution and longer duration of red tide in G. polygramma.

KZ 필터를 이용한 부산지역 PM10의 장기 추세 분석 (Analysis of the Long-term Trend of PM10 Using KZ Filter in Busan, Korea)

  • 도우곤;정우식
    • 한국환경과학회지
    • /
    • 제26권2호
    • /
    • pp.221-230
    • /
    • 2017
  • To determine the effect of air pollution reduction policies, the long-term trend of air pollutants should be analyzed. Kolmogorov-Zurbenko (KZ) filter is a low-pass filter, produced through repeated iterations of a moving average to separate each variable into its temporal components. The moving average for a KZ(m, p) filter is calculated by a filter with window length m and p iterations. The output of the first pass subsequently becomes the input for the next pass. Adjusting the window length and the number of iterations makes it possible to control the filtering of different scales of motion. To break down the daily mean $PM_{10}$ into individual time components, we assume that the original time series comprises of a long-term trend, seasonal variation, and a short-term component. The short-term component is attributable to weather and short-term fluctuations in precursor emissions, while the seasonal component is a result of changes in the solar angle. The long-term trend results from changes in overall emissions, pollutant transport, climate, policy and/or economics. The long-term trend of the daily mean $PM_{10}$ decreased sharply from $59.6ug/m^3$ in 2002 to $44.6ug/m^3$ in 2015. This suggests that there was a long-term downward trend since 2005. The difference between the unadjusted and meteorologically adjusted long-term $PM_{10}$ is small. Therefore, we can conclude that $PM_{10}$ is unaffected by the meteorological variables (total insolation, daily mean temperature, daily mean relative humidity, daily mean wind speed, and daily mean local atmospheric pressure) in Busan.

주간에 두 타워로부터 관측된 에디 공분산 자료의 확률 오차의 추정 (Estimation of the Random Error of Eddy Covariance Data from Two Towers during Daytime)

  • 임희정;이영희;조창범;김규랑;김백조
    • 대기
    • /
    • 제26권3호
    • /
    • pp.483-492
    • /
    • 2016
  • We have examined the random error of eddy covariance (EC) measurements on the basis of two-tower approach during daytime. Two EC towers were placed on the grassland with different vegetation density near Gumi-weir. We calculated the random error using three different methods. The first method (M1) is two-tower method suggested by Hollinger and Richardson (2005) where random error is based on differences between simultaneous flux measurements from two towers in very similar environmental conditions. The second one (M2) is suggested by Kessomkiat et al. (2013), which is extended procedure to estimate random error of EC data for two towers in more heterogeneous environmental conditions. They removed systematic flux difference due to the energy balance deficit and evaporative fraction difference between two sites before determining the random error of fluxes using M1 method. Here, we introduce the third method (M3) where we additionally removed systematic flux difference due to available energy difference between two sites. Compared to M1 and M2 methods, application of M3 method results in more symmetric random error distribution. The magnitude of estimated random error is smallest when using M3 method because application of M3 method results in the least systematic flux difference between two sites among three methods. An empirical formula of random error is developed as a function of flux magnitude, wind speed and measurement height for use in single tower sites near Nakdong River. This study suggests that correcting available energy difference between two sites is also required for calculating the random error of EC data from two towers at heterogeneous site where vegetation density is low.

수막하우스의 유량 및 수온에 따른 열전달 특성 분석 (Analysis of Heat Transfer Characteristics in Response to Water Flow Rate and Temperature in Greenhouses with Water Curtain System)

  • 김형권;김승희;권진경
    • 생물환경조절학회지
    • /
    • 제25권4호
    • /
    • pp.270-276
    • /
    • 2016
  • This study analysed overall heat transfer coefficient, heat transmission, and rate of indoor air heating provided by water curtain in order to determine the heat transfer characteristic of double-layered greenhouse equipped with a water curtain system. The air temperatures between the inner and outer layers were determined by the water flow rate and inlet water temperature. Higher water flow rate and inlet water temperature resulted in the increased overall heat transfer coefficient between indoor greenhouse air and water curtain. However, it was found that with higher levels of water flow rate and inlet water temperature, indoor overall heat transfer coefficient was converged about $10W{\cdot}m^{-2}{\cdot}^oC^{-1}$. The low correlation of overall heat transfer coefficient between water curtain and air within double layers was likely because the combination of greenhouse shape, wind speed and outdoor air temperature as well as water curtain affected the heat transfer characteristics. As water flow rate and inlet water temperature increased, the heat transferred into the greenhouse by water curtain also tend to rise. However it was demonstrated that the rate of heat transmission from water curtain into greenhouse with water curtain system using underground water was accounted for 22% to 28% for total heat lost by water curtain. The results of this study which quantify heat transfer coefficient and net heat transfer from water curtain may be a good reference for economical design of water curtain system.

Exposure and Risk Assessment of Operators to Insecticide Acetamiprid during Treatment on Apple Orchard

  • Kim, Eunhye;Moon, Joon-Kwan;Lee, Hyeri;Kim, Suhee;Hwang, Yon-Jin;Kim, Byung-Joon;Lee, Jinbeum;Lee, Dong-Hyuk;Kim, Jeong-Han
    • 원예과학기술지
    • /
    • 제31권2호
    • /
    • pp.239-245
    • /
    • 2013
  • Occupational exposure and risk assessment were conducted to evaluate the safety of operators when insecticide acetamiprid was applied to apple orchard using a speed sprayer. Dermal patches, cotton gloves, socks, and masks were used to monitor the dermal exposure, and personal air pump with solid sorbent was used to measure the potential inhalation exposure. In validation to analytical methods, the limit of detection and limit of quantitation were 0.25 ng and 1 ng, respectively. Good reproducibility (coefficient variation < 4%), linearity (coefficient determination > 0.999), and recovery (85.3-118.2%) were obtained. Trapping efficiency of solid sorbent was 96.4% while breakthrough did not occur. Only hand exposure was measured on the gloves during mixing/loading to give $33-1,132{\mu}g$. Exposure amount of operator 3 among 4 workers was noticeably high. The total volumes of spray liquid for operators were $535-1,235mL{\cdot}h^{-1}$, corresponding to 0.03-0.08% of the applied spray solution. Highest contaminated parts of body were thighs, chest, and lower legs. The inhalation exposure ratio to the total application amount was significantly low. However, wind seemed to affect the inhalation exposure of operator. For risk assessment, margin of safety was calculated by the application of cloth and dermal penetration rate to obtain values of much larger than 1 in all cases. Therefore, health risk of operators during treatment of acetamiprid in apple orchard could be of least possibility.

한반도 태양에너지 연구를 위한 일사량 자료의 TMY 구축 (The Generation of Typical Meteorological Year for Research of the Solar Energy on the Korean Peninsula)

  • 지준범;이승우;최영진;이규태
    • 신재생에너지
    • /
    • 제8권2호
    • /
    • pp.14-23
    • /
    • 2012
  • The TMY (Typical Meteorological Year) for the solar energy study is generated using observation data with 22 solar sites from KMA (Korea Meteorological Administration) during 11 years (2000-2010). The meteorological data for calculation the TMY are used solar radiation, temperature, dew point temperature, wind speed and humidity data. And the TMY is calculated to apply the FS (Finkelstein and Schafer) statistics and RMSE (Root Mean Squared Error) methods. FS statistics performed with each point and each variable and then selected top five candidate TMM months with statistical analysis and normalization. Finally TMY is generated to select the highest TMM score with evaluation the average errors for the 22 whole points. The TMY data is represented average state and long time variations with 22 sites and meteorological data. When TMY validated with the 11-year daily solar radiation data, the correlation coefficient was about 0.40 and the highest value is 0.57 in April and the lowest value is 0.23 in May. Mean monthly solar radiation of TMY is 411.72 MJ which is 4 MJ higher than original data. Average correlation coefficient is 0.71, the lowest correlation is 0.43 in May and the highest correlation is 0.90 in January. Accumulated annual solar radiation by TMY have higher value in south coast and southwestern region and have relatively low in middle regions. And also, differences between TMY and 11-year mean of is distributed lower 100 MJ in Kyeongbuk, higher 200 MJ in Jeju and higher 125 MJ in Jeonbuk and Jeonnam, respectively.

Recycling of Suspended Particulates by Atmospheric Boundary Depth and Coastal Circulation

  • Choi, Hyo
    • 한국환경과학회:학술대회논문집
    • /
    • 한국환경과학회 2003년도 International Symposium on Clean Environment
    • /
    • pp.19-26
    • /
    • 2003
  • The dispersion of recycled particulates in the complex coastal terrain containing Kangnung city, Korea was investigated using a three-dimensional non-hydrostatic numerical model and lagrangian particle model (or random walk model). The results show that particulates at the surface of the city that float to the top of thermal internal boundary layer (TIBL) are then transported along the eastern slope of the mountains with the passage of sea breeze and nearly reach the top of the mountains. Those particulates then disperse eastward at this upper level over the coastal sea and finally spread out over the open sea. Total suspended particulate (TSP) concentration near the surface of Kangnung city is very low. At night, synoptic scale westerly winds intensify due to the combined effect of the synoptic scale wind and land breeze descending the eastern slope of the mountains toward the coast and further seaward. This increase in speed causes development of internal gravity waves and a hydraulic jump up to a height of about 1km above the surface over the city. Particulate matter near the top of the mountains also descends the eastern slope of the mountains during the day, reaching the central city area and merges near the surface inside the nocturnal surface inversion layer (NSIL) with a maximum ground level concentration of TSP occurring at 0300 LST. Some particulates were dispersed following the propagation area of internal gravity waves and others in the NSIL are transported eastward to the coastal sea surface, aided by the land breeze. The following morning, particulates dispersed over the coastal sea from the previous night, tend to return to the coastal city of Kangnung with the sea breeze, developing a recycling process and combine with emitted surface particulates during the morning. These processes result in much higher TSP concentration. In the late morning, those particulates float to the top of the TIBL by the intrusion of the sea breeze and the ground level TSP concentration in the city subsequently decreases.

  • PDF

베인과 블레이드 사이의 상대위치 변화에 따른 터빈 블레이드 표면에서의 열/물질전달 특성 (Effect of Relative Position of Vane and Blade on Heat/Mass Transfer Characteristics on Stationary Turbine Blade Surface)

  • 이동호;조형희
    • 한국유체기계학회 논문집
    • /
    • 제8권4호
    • /
    • pp.27-38
    • /
    • 2005
  • The present study investigated the effect of relative position of the blade on blade surface heat transfer. The experiments were conducted in a low speed wind tunnel with a stationary annular turbine cascade. The test section has a single turbine stage composed of sixteen guide vanes and blades. The chord length of the blade is 150 mm and the mean tip clearance of the blade is $2.5\%$ of the blade chord. The Reynolds number based on blade inlet velocity and chord length is $1.5{\times}105$ and mean turbulence intensity is about $3\%$. To investigate the effect of relative position of blade, the blade at six different positions in a pitch was examined. For the detailed mass transfer measurements, a naphthalene sublimation technique was used. In general, complex heat transfer characteristics are observed on the blade surface due to various flow characteristics, such as a laminar flow separation, relaminarization, flow acceleration, transition to turbulence and tip leakage vortices. The results show that the blade relative position affects those heat transfer characteristics because the distributions of incoming flow velocity and turbulence intensity are changed. Especially, the heat transfer pattern on the near-tip region is significantly affected by the relative position of the blade because the effect of tip leakage vortex is strongly dependent on the blade position. On the pressure side, the effect of blade position is not so significant as on the suction side surface although the position and the size of the separation bubble are changed.

2008년 광주지역 검댕입자 특성 및 광학적 산란효과 보상 (Characteristics of Black Carbon in PM2.5 Observed in Gwangju for Year 2008 and Examination of Filter Loading Effect)

  • 정정훈;박승식
    • 한국대기환경학회지
    • /
    • 제26권4호
    • /
    • pp.392-402
    • /
    • 2010
  • Black carbon (BC) concentrations were measured with an aethalometer (AE-16, 880 nm) at time interval of 5-min at an urban site of Gwangju over a year 2008. 24-hr filter-based integrated measurements of $PM_{2.5}$ particles were also made at the same site during the winter and summer intensive periods to test any optical loading bias in the raw BC data measured by aethalometer. BC concentration was higher in winter than in summer, possibly due to increase in emissions from energy consumption and poor dispersion with reduction of boundary layer in winter. Also temporal cycles of BC indicate that short-term transient spikes were common, occurring primarily during the rush-hour periods. A similar feature was also observed in diurnal concentration cycle of CO, mainly emitted from motor vehicles. When both low wind speed and weather patterns such as mist, haze and etc were combined, high BC concentrations frequently occurred. The amount of optical loading effect described by the "k" factor showed the seasonal variation, ranging from 0.0003 to 0.0036. This implies that optical loading effect is not seen at all times. From the comparison between the filter-based elemental carbon (EC) and aethalometer BC data, it was found that the loading compensated BC values were more reasonable than the raw BC ones reported from the aethalometer.