• Title/Summary/Keyword: low velocity

Search Result 2,854, Processing Time 0.025 seconds

Archaeometric Characterization of Raw Materials and Tempers of Bricks Used in the Brick Tombs during Ungjin Period of Baekje (백제 웅진기 벽돌무덤에 사용된 벽돌의 재료와 첨가물 특성 분석)

  • Sungyoon Jang;Hong Ju Jin
    • Economic and Environmental Geology
    • /
    • v.55 no.6
    • /
    • pp.571-582
    • /
    • 2022
  • In this study, the raw material and tempers of bricks used in three brick tombs built in Gongju, during the Ungjin period of Baekje were investigated. The royal tomb of King Muryeong, the 6th tomb in the royal tombs, and Kyochonri brick tomb remained in Gongju and the bricks of each site had different shape and physical properties despite their similarity in raw materials. As the results of the mineralogical and microstructural analysis, the bricks of the royal tombs were made of refined raw materials, and were infrequently added crushed bricks(grogs) as a tempering material. On the other hand, thick and elongated pores of bricks from the Kyochonri brick tomb were frequently found, and the remains of plant carbonization are observed in their microstructures. Since the pores are mainly distributed in a thickness of 0.3 to 1 mm, it is estimated that bricks were produced by adding a certain size of the plant to refined soil, and grogs also were added as a tempering material. In particular, it was found that adding plants and grogs in raw materials of bricks caused thick pores or cracks in the internal structure. Since the bricks of the Kyochonri brick tomb have internal cracks and low firing temperature, the ultrasonic velocity of the bricks was lower than that of the royal tomb bricks. It means that the mechanical strength of these bricks were relatively low. Accordingly, it is estimated that the tempering materials, firing temperature, and internal structures of bricks can affect durability of the brick, and it can be thought as a difference in the manufacturing technology of brick making.

Measurements of Void Concentration Parameters in the Drift-Flux Model (상대유량 모델내의 기포분포계수 측정에 관한 연구)

  • Yun, B.J.;Park, G.C.;Chung, C.H.
    • Nuclear Engineering and Technology
    • /
    • v.25 no.1
    • /
    • pp.91-101
    • /
    • 1993
  • To predict accurately the thermal hydraulic behavior of light water reactors during normal or abnormal operation, the accurate estimation of the void distribution is required. Up to date, many techniques for predicting void fraction of two-phase flow systems have been suggested. Among these techniques, the drift-flux model is widely used because of its exact calculation ability and simplicity. However, to get more accurate prediction of void fraction using drift-flux model, slip and flow regime effects must be considered more properly In the drift-flux method, these two effects are accounted for by two drift-flux parameters ; $C_{o}$ and (equation omitted). At earlier stage, $C_{o}$ is measured in a circular tube. In this study, $C_{o}$ is experimentally determined by measuring local void fraction and vapor velocity distribution in a rectangular subchannel having 4 heating rods which simulates nuclear subchannels. The measurements are peformed with two-electrical conductivity probes which are known to be adequate for measuring local parameters. The experiments are performed at low flow rate and the system pressure less than 3 atmo spheric pressure. In this experiment, (equation omitted), is not measured, but quoted from well-known empirical correlation to formulate $C_{o}$. Finally, $C_{o}$ is expressed as a function of channel averaged void fraction. fraction.

  • PDF

Early Aortic Valve Replacement in Symptomatic Normal-Flow, Low-Gradient Severe Aortic Stenosis: A Propensity Score-Matched Retrospective Cohort Study

  • Kyu Kim;Iksung Cho;Kyu-Yong Ko;Seung-Hyun Lee;Sak Lee;Geu-Ru Hong;Jong-Won Ha;Chi Young Shim
    • Korean Circulation Journal
    • /
    • v.53 no.11
    • /
    • pp.744-755
    • /
    • 2023
  • Background and Objectives: Aortic valve replacement (AVR) is considered a class I indication for symptomatic severe aortic stenosis (AS). However, there is little evidence regarding the potential benefits of early AVR in symptomatic patients diagnosed with normal-flow, low-gradient (NFLG) severe AS. Methods: Two-hundred eighty-one patients diagnosed with symptomatic NFLG severe AS (stroke volume index ≥35 mL/m2, mean transaortic pressure gradient <40 mmHg, peak transaortic velocity <4 m/s, and aortic valve area <1.0 cm2) between January 2010 and December 2020 were included in this retrospective study. After performing 1:1 propensity score matching, 121 patients aged 75.1±9.8 years (including 63 women) who underwent early AVR within 3 months after index echocardiography, were compared with 121 patients who received conservative care. The primary outcome was a composite of all-cause death and heart failure (HF) hospitalization. Results: During a median follow-up of 21.9 months, 48 primary outcomes (18 in the early AVR group and 30 in the conservative care group) occurred. The early AVR group demonstrated a significantly lower incidence of primary outcomes (hazard ratio [HR], 0.52; 95% confidence interval [CI], 0.29-0.93; p=0.028); specifically, there was no significant difference in all-cause death (HR, 0.51; 95% CI, 0.23-1.16; p=0.110), although the early AVR group showed a significantly lower incidence of hospitalization for HF (HR, 0.43; 95% CI, 0.19-0.95, p=0.037). Subgroup analyses supported the main findings. Conclusions: An early AVR strategy may be beneficial in reducing the risk of a composite outcome of death or hospitalization for HF in symptomatic patients with NFLG severe AS. Future randomized studies are required to validate and confirm our findings.

Analysis of Joint Characteristics and Rock Mass Classification using Deep Borehole and Geophysical Logging (심부 시추공 회수코어와 물리검층 자료를 활용한 절리 및 암반등급 평가)

  • Dae-Sung Cheon;Seungbeom Choi;Won-Kyong Song;Seong Kon Lee
    • Tunnel and Underground Space
    • /
    • v.34 no.4
    • /
    • pp.330-354
    • /
    • 2024
  • In site characterization of high-level radioactive waste, discontinuity(joint) distribution and rock mass classification, which are key evaluation parameters in the rock engineering field, were evaluated using deep boreholes in the Wonju granite and Chuncheon granite, which belong to Mesozoic Jurassic era. To evaluate joint distribution characteristics, fracture zones and joint surfaces extracted from ATV data were used, and major joint sets were evaluated along with joint frequency according to depth, dip direction, and dip. Both the Wonju and Chuncheon granites that were studied showed a tendency for the frequency of joints to increase linearly with depth, and joints with high angles were relatively widely distributed. In addition, relatively large amounts of weathering tended to occur even in deep depth due to groundwater inflow through high-angle joints. RQD values remained consistently low even at considerable depth. Meanwhile, joint groups with low angles showed different joint characteristics from joint sets with high angles. Rock mass classification was performed based on RMR system, and along with rock mass classification for 50 m intervals where uniaxial compressive strength was performed, continuous rock mass classification according to depth was performed using velocity log data and geostatistical techniques. The Wonju granite exhibited a superior rock mass class compared to the Chuncheon granite. In the 50 m interval and continuous rock mass classification, the shallow part of the Wonju granite showed a higher class than the deep part, and the deep part of the Chuncheon granite showed a higher class than the shallow part.

Optimization of the P+ Region in SiC-Based MPS Diodes: Enhancing BFOM and Alleviating Snap-Back Phenomenon (SiC 기반 MPS 다이오드 P+ 영역 최적화: BFOM 향상과 Snap-Back 현상 완화를 위한 연구)

  • Seung-Hyun Park;Tae-Hee Lee;Se-Rim Park;Ju-Eun Yun;Geon-Hee Lee;Ji-Hwan Jeon;Jong-Min Oh;Weon Ho Shin;Sang-Mo Koo
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.37 no.6
    • /
    • pp.675-679
    • /
    • 2024
  • Wide bandgap (WBG) devices, especially SiC, are gaining traction as materials for high-power EV conversion devices due to their superior efficiency and switching capabilities compared to Si-based power devices. SiC allows for high power, high temperature, and high frequency applications because of its outstanding thermal conductivity, saturation velocity, and dielectric breakdown field. SiC-based MPS diodes combine the advantages of SiC-based SBDs and PiN diodes, allowing high-frequency switching operation with low leakage currents under high voltage conditions. However, MPS diodes exhibit snapback phenomena influenced by the P+ region's size, necessitating optimization. A TCAD simulation studied the impact of the P+ region's depth and width on MPS diode performance. Increasing the P+ width raised the On-specific resistance (Ron,sp) and lowered the maximum voltage during snapback (Vsnap). Increasing the depth decreased both Breakdown voltage (BV) and Vsnap. A trade-off between the semiconductor performance index BFOM and Vsnap was identified, leading to optimized dimensions. The optimized MPS diode shows a low Vsnap of about 3.89 V and a high BFOM of 1.72 GW·cm2, highlighting its potential as a next-generation high-performance power conversion device.

Pulmonary Hypertension Secondary to Bronchopulmonary Dysplasia in Very Low Birth Weight Infants (<1,500 g) (기관지 폐 이형성증을 가진 극소 저체중 출생아에서 폐고혈압증)

  • Yoo, Hye-Soo;Kim, Myo-Jing;Kang, Ji-Man;Lee, Cha-Gon;Kim, Jin-Kyu;Ahn, So-Yoon;Kim, Eun-Sun;Huh, June;Chang, Yun-Sil;Kang, I-Seok;Park, Won-Soon;Lee, Heung-Jae
    • Neonatal Medicine
    • /
    • v.18 no.1
    • /
    • pp.96-103
    • /
    • 2011
  • Purpose: Although infants with bronchopulmonary dysplasia (BPD) are at risk of developing secondary pulmonary hypertension (PH), which is associated with significant morbidity and mortality, little has been reported about the incidence, clinical course and prognosis of PH secondary to BPD in premature infants. This study was done to investigate the incidence, risk factors, clinical course, and the ultimate prognosis of PH developed secondary to BPD in very low birth weight infants (<1,500 g). Methods: Medical records of very low birth weight infant (VLBWI) admitted to Samsung Medical Center NICU from January 2000 to July 2007 were reviewed retrospectively. BPD was defined by Jobe's classification. The diagnosis of pulmonary hypertension was established as velocity of tricuspid valve regurgitation (TR) ${\geq}$3 m/s and a flattening of the intraventricular septum by conducting Doppler echocardiography. Results: The incidence of pulmonary hypertension was 6% in VLBWI with BPD and it developed in moderate to severe BPD. The diagnosis of pulmonary hypertension was made on postnatal 133 days (range 40-224 days) and the risk factors related to developing pulmonary hypertension were severe BPD, small for gestational age and outborn infants. The mortality rate was 57% and especially higher in severe BPD (70%). The time to recovery spent 3 months (range 1-10 months) in survived patients. Conclusion: Based on the results of this research, pulmonary hypertension secondary to BPD in VLBWI related to severity of BPD and had a poor prognosis. We expect that regular long-term echocardiography may be helpful in treating reversible in VLBWI with moderate to severe BPD.

Effects of Early Parenteral Nutrition for Extremely Low Birth Weight Infants (초극소 저출생 체중아(${\leq}$1,000 g)에서 조기에 시작하는 정맥 영양공급의 효과)

  • Ahn, So-Yoon;Shin, Ji-Hun;Shin, Jung-Hee;Sung, Se-In;Jung, Ji-Mi;Kim, Jin-Kyu;Chang, Yun-Sil;Jang, Yun-Sil;Park, Won-Soon
    • Neonatal Medicine
    • /
    • v.18 no.1
    • /
    • pp.76-81
    • /
    • 2011
  • Purpose: The object of this study was to evaluate the efficacy of early total parenteral nutrition with early amino acid in extremely low birth weight infant (ELBWI). Methods: We retrospectively analyzed the medical records of all ELBWIs who were born and admitted to Samsung Medical Center from January 2003 to December 2003 and January 2009 to December 2009 and alive at the time of discharge. Data for nutritional status and morbidities were compared between period 1 (2003, n=22), in which parenteral nutritional support was started gradually over several days and period 2 (2009, n=38), in which parenteral nutrition with amino acid was started as soon as possible after birth. Results: Compared to period 1, birth weight and Apgar score were lower in period 2. The intake amount of glucose, amino acid and total calorie was higher and the level of blood urea nitrogen was increased more from 7th day to 14th day after birth in period 2 when compared than period 1. The weight gain velocity was faster at 7th and 14th postnatal day in period 2. There were no differences in the incidence of necrotizing enterocolitis, moderate to severe bronchopulmonary dysplasia, and severe intraventricular hemorrhage (${\geq}$ Gr III) between two periods but, the incidence of periventricular leukomalacia(PVL) was significantly lower in period 2. Conclusion: Early initiation of total parenteral nutrition with early amino acid in ELBWIs was beneficial at weight gain with lowering catabolism and increasing anabolism. And it could be related with reducing the incidence of PVL.

Evaluation of frictional forces between orthodontic brackets and archwires (교정용 브라켓과 교정선 사이의 마찰력)

  • Jeong, Tae-Jong;Choie, Mok-Kyun
    • The korean journal of orthodontics
    • /
    • v.30 no.5 s.82
    • /
    • pp.613-623
    • /
    • 2000
  • The purpose of this study was to amount of the frictional forces with the brackets and wires, ligation methods, dry/wet, offsets, interbracket distances, velocity and to compare them each other by different conditions. This study tested 0.018'x0.025' slot sized 8 types of orthodontic bracket systems and 0.016', 0.016'x0.022' sized stainless steel, NiTi, Cu-NiTi orthodontic wires. One cuspid bracket were positioned on the slide glass and archwire was engaged into bracket and ligated with elastomeric modules. The values of frictional forces were measured with the instron universal testing machine. The results were as follows; 1. Polycrystalline ceramic bracket had the highest mean frictional forces and followed and by ceramic reinforced plastic bracket, metal bracket, plastic bracket with metal slot, monocrystalline ceramic bracket, single bracket, self-ligating bracket, friction free bracket in descending order. The self-ligating bracket showed low frictional forces in the round wires and high frictional forces in the rectangular wires. 2. Stainless steel wires had the least frictional forces and followed by NiTi, Cu-NiTi wires in descending order. Round wires had lower frictional forces then that of rectangular wires. 3. The stainless steel ligation method had significantly greater mean frictional forces them the elastomeric module ligation method. 4. Artificial saliva statistically increased the frictional forces in stainless steel wire, NiTi wire and Cu-NiTi wire. 5. There was a statistically significant difference with offset change 6. There was no statistically significant difference with interbracket distance in stainless steel wires but a significant difference in NiTi wires as the interbracket was decreased. 7 There was no statistically significant difference with velocity change. From the above findings, self-ligating bracket, stainless steel wires and the elastomeric module ligation method might be effective than any other materials to reduce the frictional forces in the orthodontic treatment and can be correlated to clinical situations seen in orthodontic patient care.

  • PDF

Suggestion of Additional Criteria for Site Categorization in Korea by Quantifying Regional Specific Characteristics on Seismic Response (지역고유 지진응답 특성 정량화를 통한 국내 부지 분류 기준의 추가 반영 제안)

  • Sun, Chang-Guk
    • Geophysics and Geophysical Exploration
    • /
    • v.13 no.3
    • /
    • pp.203-218
    • /
    • 2010
  • The site categorization and corresponding site amplification factors in the current Korean seismic design guideline are based on provisions for the western United States (US), although the site effects resulting in the amplification of earthquake ground motions are directly dependent on the regional and local site characteristic conditions. In these seismic codes, two amplification factors called site coefficients, $F_a$ and $F_v$, for the short-period band and midperiod band, respectively, are listed according to a criterion, mean shear wave velocity ($V_S$) to a depth of 30 m, into five classes composed of A to E. To suggest a site classification system reflecting Korean site conditions, in this study, systematic site characterization was carried out at four regional areas, Gyeongju, Hongsung, Haemi and Sacheon, to obtain the $V_S$ profiles from surface to bedrock in field and the non-linear soil properties in laboratory. The soil deposits in Korea, which were shallower and stiffer than those in the western US, were examined, and thus the site period in Korea was distributed in the low and narrow band comparing with those in western US. Based on the geotechnical characteristic properties obtained in the field and laboratory, various site-specific seismic response analyses were conducted for total 75 sites by adopting both equivalent-linear and non-linear methods. The analysis results showed that the site coefficients specified in the current Korean provision underestimate the ground motion in the short-period range and overestimate in the mid-period range. These differences can be explained by the differences in the local site characteristics including the depth to bedrock between Korea and western US. Based on the analysis results in this study and the prior research results for the Korean peninsula, new site classification system was developed by introducing the site period as representative criterion and the mean $V_S$ to a depth of shallower than 30 m as additional criterion, to reliably determine the ground motions and the corresponding design spectra taking into account the regional site characteristics in Korea.

A Comparative Study on the Electrophysiological Properties of Medial and Lateral Spinoreticular Tract Cells in Cats (고양이의 내측 및 외측 척수망상로 세포의 전기생리학적 비교연구)

  • Lee, Suk-Ho;Jun, Jae-Yeol;Park, Choon-Ok;Goo, Yong-Sook;Kim, Jun;Sung, Ho-Kyung
    • The Korean Journal of Physiology
    • /
    • v.24 no.1
    • /
    • pp.181-194
    • /
    • 1990
  • Antidromically activated spinoreticular tract (SRT) cell units in the lumbosacral enlargement of ${\alpha}-chloralose$ anesthetized cats were classified as medial and lateral SRT units according to the location of their axonal termination. Identified SRT units were tested fer antidromic conduction velocity, laterality of their axonal projection, the location in spinal gray, peripheral receptive field, the response pattern to graded mechanichal stimulation and the responsiveness to $A{\delta}$ and C volley of the peripheral nerve. 1) The 59% of 34 medial SRT units were recorded in ipsilateral side to the antidromic stimulation site, but 60% of the 47 lateral SRT units projected to contralateral side. 2) Most of the medial SRT cells and rostral ventrolateral medulla (RVLM)-projecting lateral SRT cells were recorded in lamina VII & VIII. The LRN (lateral reticular nucleus)-projecting SRT cells, however, distributed through all the laminae except superficial ones (I & II). 3) The identified SRT units were classified as low theshold (LT), deep, high threshold (HT), wide dynamic range (WDR) cells, based on the response patterns to graded mechanical stimuli. The proportion of SRT units which receive noxious input was 37.5%, 25% and 75% in the medial, LRN-projecting and RVLM SRT group, respectively. 4) There was no significant difference in the mean conduction velocities between the 3 groups. But the deep cells had significantly higher velocity than that of the HT cells. The above results show that the peripheral inputs to the SRT units are different in the 3 groups: medial, LRN & RVLM SRT group. Especially in case of the SRT cells projecting to RVLM which is a probable candidate fur the integration center of various pressor reflexes such as somatosympathetic reflex, the noxious informations occupy higher proportion of input to them than in other groups. Therefore the noxious information transmitted through the lateral SRT destined for RVLM is expected to play a role in somatosymapthetic reflex.

  • PDF