• Title/Summary/Keyword: low velocity

Search Result 2,854, Processing Time 0.029 seconds

The Study for Characteristic of Direct Methanol Fuel Cell in Ambient Temperature (상온 상태에서 직접 메탄올 연료전지의 특성 연구)

  • Yun, Hyo-Jin;Kim, Jeong-Ju;Kim, Dong-Jin
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.10 no.5
    • /
    • pp.955-961
    • /
    • 2009
  • Present, a portable battery have problem that the volume increases according to capacity Increase. Direct Methanol Fuel Cell is alternative by solution plan of this problem. In this paper, the characteristics of DMFC are analyzed by change in concentration and discharge of fuel in natural convection and room temperature condition. According to the analysis result, polarization by delay of diffusion velocity of hydrogen ion appeared in methanol of low concentration. And if have a lot of supplies of methanol, generation power declines by electric cell cooling effect.

Vacuum Die Casting Mold Design of Fuel Cell Bipolar Plate using Die Filling Simulation and Experimental Verification (금형 충전 해석을 이용한 연료전지 분리판 진공 다이캐스팅 금형 설계 방안 및 실험 검증)

  • Jin, Chul-Kyu;Jang, Chang-Hyun;Kang, Chung-Gil
    • Journal of Korea Foundry Society
    • /
    • v.32 no.2
    • /
    • pp.65-74
    • /
    • 2012
  • In this paper, we present the results of our studies on optimal die design towards development of a vacuum die casting process to fabricate fuel cell bipolar plate with micro-channel array. Cavity and overflow shape is designed by computational filling analysis of MAGMA soft. Optimal die design consists of seven overflows at the end of cavity and three overflows at each side wall of cavity. The molten metal that passed the gate and reached the side wall flowed into the side overflow, no turbulent flow occurred, and the filling behavior and velocity distribution were uniform. In addition, partially solidified molten metal passing through the channel was perfectly eliminated by overflow without back-flow. When vacuum pressure, injection speed of low and high region was 300 mbar, 0.3 m/s and 2.5 m/s respectively with Silafont 36 die casting alloy, sound sample without casting defects was obtained. The experimental results are nearly consistent with simulation results.

A High Performance Permanent Magnet Synchronous Motor Servo System Using Predictive Functional Control and Kalman Filter

  • Wang, Shuang;Zhu, Wenju;Shi, Jian;Ji, Hua;Huang, Surong
    • Journal of Power Electronics
    • /
    • v.15 no.6
    • /
    • pp.1547-1558
    • /
    • 2015
  • A predictive functional control (PFC) scheme for permanent magnet synchronous motor (PMSM) servo systems is proposed in this paper. The PFC-based method is first introduced in the control design of speed loop. Since the accuracy of the PFC model is influenced by external disturbances and speed detection quantization errors of the low distinguishability optical encoder in servo systems, it is noted that the standard PFC method does not achieve satisfactory results in the presence of strong disturbances. This paper adopted the Kalman filter to observe the load torque, the rotor position and the rotor angular velocity under the condition of a limited precision encoder. The observations are then fed back into PFC model to rebuild it when considering the influence of perturbation. Therefore, an improved PFC method, called the PFC+Kalman filter method, is presented, and a high performance PMSM servo system was achieved. The validity of the proposed controller was tested via experiments. Excellent results were obtained with respect to the speed trajectory tracking, stability, and disturbance rejection.

Numerical analysis of the differential pressure venturi-cone flowmeter (차압식 벤튜리콘 유량계에 대한 유동해석)

  • 윤준용;맹주성;이정원
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.10 no.6
    • /
    • pp.714-720
    • /
    • 1998
  • The differential pressure venturi-cone flowmeter is an advanced flowmeter which has many advantages such as wide range of measurement, high accuracy, excellent flow turn-down ratio, low headless, short installation pipe length requirement, and etc. Like other differential pressure flowmeters, the venturi-cone flowmeter uses the law of energy conservation, but its shape and position make it perform better than others. The cone acts as its own flow conditioner and mixer, fully conditioning and mixing the flow prior to measurement. For the analysis, we used Reynolds-averaged Wavier-Stokes equations and k-$\omega$ turbulence model. The equations were fully transformed into the computational domain, the pressure-velocity coupling was made through SIMPLER algorithm, and the equations were discretized using finite analytic solutions of the liberalized equations(Finite Analytic Method). To control the separation phenomenon on the cone surface, we proposed a new shape of cone, and analyzed the flowfield in the new flowmeter system, and found the improvement on the performance of the new cone flowmeter.

  • PDF

The Characteristics of Tidal Current and Water Mass in the Narrow Channel 1. Tidal Current and Water mass in the Chungmu Channel (협수로의 수리 특성과 수괴구조 1. 충무수로의 조류와 수괴구조)

  • Park, Byung-Soo
    • Journal of Fisheries and Marine Sciences Education
    • /
    • v.13 no.2
    • /
    • pp.168-177
    • /
    • 2001
  • The flow pattern and water mass structure in the Chungmu channel were investigated using the field observations during June and July, 2001. The currents in the channel may be regarded as a hydraulic current decided by difference of tide levels between two sides in the channel. The strongest current in the channel occurs around in high water and low water. The coefficient C to be determined the characteristics of velocity in the channel was obtained from an equation, $u=C{\sqrt{2gh}}$ and ranges from 0.37 to 0.65 in the Chungmu Channel at the spring tide and from 0.23 to 0.37 at the neap tide. Eastward tidal transport is usually larger than that of westward transport in Chungmu the Channel. Sea water exchange rates are 39.2% in spring tide and 20.5% in neap tide respectively. The water mass structure in the channel is changed by the speed of the tidal current. The water mass is well mixed at the high water when the current is strong and is stratified at slack water when the current is weak.

  • PDF

Air-Water Countercurrent Flow Limitation in a Horizontal Pipe Connected to an Inclined Riser

  • Kang, Seong-Kwon;Chu, In-Cheol;No, Hee-Cheon;Chun, Moon-Hyun;Sung, Chang-Kyung
    • Nuclear Engineering and Technology
    • /
    • v.31 no.6
    • /
    • pp.548-560
    • /
    • 1999
  • An experimental investigation has been peformed to examine the effects of various geometrical parameters and an initial operating condition on the air-water countercurrent How limitation (CCFL) in a simulated PWR hot leg. A total of 118 experimental data for the onset of CCFL and zero liquid penetration were obtained for various combinations of test parameters. It was observe that the CCFL can be classified into three different categories: (the onset of CCFL, (the partial liquid delivery, and (r) the zero liquid penetration. The observed mechanisms of the onset of CCFL were different depending on the inlet water flow rate. The parametric effects of pipe diameter, horizontal pipe length, horizontal pipe length-to-diameter (L/D) ratio, and initial water level in the horizontal pipe of the test section on the onset of air-water CCFL were also examined. An empirical correlation for the onset of CCFL in a horizontal pipe connected to an inclined riser was developed in terms of Wallis flooding parameters for the low inlet water flow rate region. Comparisons of the present empirical correlation with the air-water CCFL data of large pipe diameters show that the present correlation agrees more closely with the experimental data than the existing CCFL correlations.

  • PDF

Biomarkers for Evaluation of Prostate Cancer Prognosis

  • Esfahani, Maryam;Ataei, Negar;Panjehpour, Mojtaba
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.16 no.7
    • /
    • pp.2601-2611
    • /
    • 2015
  • Prostate cancer, with a lifetime prevalence of one in six men, is the second cause of malignancy-related death and the most prevalent cancer in men in many countries. Nowadays, prostate cancer diagnosis is often based on the use of biomarkers, especially prostate-specific antigen (PSA) which can result in enhanced detection at earlier stage and decreasing in the number of metastatic patients. However, because of the low specificity of PSA, unnecessary biopsies and mistaken diagnoses frequently occur. Prostate cancer has various features so prognosis following diagnosis is greatly variable. There is a requirement for new prognostic biomarkers, particularly to differentiate between inactive and aggressive forms of disease, to improve clinical management of prostate cancer. Research continues into finding additional markers that may allow this goal to be attained. We here selected a group of candidate biomarkers including PSA, PSA velocity, percentage free PSA, $TGF{\beta}1$, AMACR, chromogranin A, IL-6, IGFBPs, PSCA, biomarkers related to cell cycle regulation, apoptosis, PTEN, androgen receptor, cellular adhesion and angiogenesis, and also prognostic biomarkers with Genomic tests for discussion. This provides an outline of biomarkers that are presently of prognostic interest in prostate cancer investigation.

A Numerical Study on the Propane Combustion Characteristics in a Catalytic Combustor (프로판의 촉매연소 특성에 관한 수치적 연구)

  • Lee, Youn-Hwa;Kim, Chong-Min;Kim, Man-Young;Yu, Myoung-Jong
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2009.05a
    • /
    • pp.247-250
    • /
    • 2009
  • The catalytic combustor has the advantage of stable combustion under very lean conditions with low emissions of $NO_x$, CO and unburned hydrocarbon(UHC). Notwithstanding these advantages, the commercial application of the catalytic combustion has been delayed due to the complicated reaction process. For the stable operation of catalytic combustor, study on the combustion characteristics of the catalytic combustor is needed. So, in this study, numerical study on the propane combustion characteristics of the catalytic combustor with Pd-based catalyst is performed.

  • PDF

A Study on Transition of Flame Extinction at Low Strain Rate Counterflow Flames (저신장율 대향류화염에서 화염소화에 있어서 천이에 대한 연구)

  • Park, Dae-Geun;Park, Jeong;Kim, Jeong-Soo;Bae, Dae-Suk
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2009.11a
    • /
    • pp.197-201
    • /
    • 2009
  • Experiments were conducted to study the transition of shrinking flame disk to flame hole in counterflow diffusion flames. The studies of transition are well described by varying burner diameters, global strain rate and velocity ratio. It is experimentally verified that radial conduction heat loss is affected at even high strain rate flames for appropriately small burner diameters. It is also shown that flame extinction modes are grouped into three and particularly, hole or stripe is observed in sufficiently high strain rate flames. There exists critical radius according to burner diameter which divide flame extinction modes into three parts.

  • PDF

A Study on the Zeta Potential Measurement and the Stability Analysis of Nano Fluids using a Particle Image Processing System (입자 영상 처리 시스템을 이용한 콜로이드 입자의 제타포텐셜 측정 및 나노유체 분산 특성 연구)

  • Lee, J.K.;Kim, S.C.;Kim, H.J.;Lee, C.G.;Ju, C.H.;Lee, L.C.
    • Journal of ILASS-Korea
    • /
    • v.8 no.1
    • /
    • pp.16-22
    • /
    • 2003
  • Zeta potential measurements of colloid particles suspended in a liquid are performed by a Zeta Meter developed. There are many applications of colloid stability in spray technology, paints, wastewater treatment, and pharmaceuticalse. Zeta potentials of charged particles are obtained by measuring the electrophoretic velocities of the particles using video enhanced microscopy and image analysis program. The values of zeta potential of polystyrene latex(PSL), $silica(SiO_2)$M, polyvinylidence difluoride(PVDF), silicon nitride, and alumina particles in deionized (DI) water were measured to be -40.5, -31.9, -25.2, -15.1 and -10.1mV, respectively. The particles having high zeta potential less than -20 mV are stable in DI water, because the double layers of them have strong repulsive forces mutually, and the particles having low zeta potential over -20mV are unstable due to Van Der Waals forces. Silica(>20nm), PSL, aluminum and PVDF particles were found to be stable that would remain separate and well disperse, while silicon nitride and alumina particles were found to be unstable that would gradually agglomerate in DI water.

  • PDF